Bio-inspired self-agitator for convective heat transfer enhancement

Convective heat transfer plays an important role in both the fundamental research and the development of high-performance heat exchangers. Inspired by blades of grass vibrating in the wind, we developed a self-agitator for convective heat transfer enhancement. Because of fluid-structure interactions, the agitator, with self-sustained vibration, can generate strong vortices to significantly break the thermal boundary layer and improve fluid mixing for enhanced convective heat transfer. In particular, we establish a methodology to link the vorticity field at a preferred frequency to the optimal improvement in the convective heat transfer. To identify the self-agitator preferred frequency, mode analysis is performed with simulation results using dynamic mode decomposition. Experimental results are also obtained to further validate the proposed approach. These results show that the proposed self-agitator design can improve the convective heat transfer by 120% in a conventional heat exchanger without additional pumping power requirements and can achieve a Nusselt number of up to 30 within the laminar flow region, which is improved by 200% with the same Reynolds number compared to the clean channel.

Li, Zheng↗

Convective Heat Transfer Coefficients of Automatic Transmission Fluid Jets with Implications for Electric Machine Thermal Management: Preprint

Thermal management for electric machines (motors/ generators) is important as the automotive industry continues to transition to more electrically dominant vehicle propulsion systems. Cooling of the electric machine(s) in some electric vehicle traction drive applications is accomplished by impinging automatic transmission fluid (ATF) jets onto the machine's copper windings. In this study, we provide the results of experiments characterizing the thermal performance of ATF jets on surfaces representative of windings, using Ford's Mercon LV ATF. Experiments were carried out at various ATF temperatures and jet velocities to quantify the influence of these parameters on heat transfer coefficients. Fluid temperatures were varied from 50 degrees C to 90 degrees C to encompass potential operating temperatures within an automotive transaxle environment. The jet nozzle velocities were varied from 0.5 to 10 m/s. The experimental ATF heat transfer coefficient results provided in this report are a useful resource for understanding factors that influence the performance of ATF-based cooling systems for electric machines.

33 ADVANCED PROPULSION SYSTEMS↗

Surface Temperature Effect on Convective Heat Transfer Coefficients for Jet Impingement Cooling of Electric Machines with Automatic Transmission Fluid: Preprint

In this study, the results of NREL's continued work on experimental characterization of the thermal performance of free-surface jets of automatic transmission fluid impinged on a heated target surface are presented. The measured heat transfer coefficients are useful for understanding factors influencing performance of driveline fluid-based cooling systems for electric machines and help designers in developing high-performance, power-dense and reliable machines. Experiments were carried out for different fluid and target surface temperatures (50 degrees C, 70 degrees C, and 90 degrees C for the fluid and 90 degrees C, 100 degrees C, 110 degrees C, and 120 degrees C for the target surface). Impinging jet velocities (0.5 m/s to 7.5 m/s) and the jet position on the target surface (center versus edge) were also varied. The impinging angle was kept at 90 degrees relative to the target surface. It was found that higher target surface temperature increased heat transfer coefficients, namely, increasing surface temperature from 90 degrees C to 120 degrees C enhanced heat transfer coefficient values at higher impinged jet velocities (7.5 m/s) by up to 15%.

33 ADVANCED PROPULSION SYSTEMS↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

Natural convection heat transfer from two horizontal cylinders

Natural convection heat transfer from a single horizontal cylinder and a pair of vertically aligned horizontal cylinders is investigated. Surface heat transfer distributions around the circumference of the cylinders are presented for Rayleigh numbers of 2 x 10{sup 6}, 4 x 10{sup 6} and 6 x 10{sup 6} and a range of cylinder spacings of 1.5, 2 and 3 diameters. With a cylinder pairing the lower cylinder is unaffected by the presence of the second cylinder; the same is true of the upper cylinder if the lower one is not heated. However, when both cylinders are heated it has been found that a plume rising from the heated lower cylinder interacts with the upper cylinder and significantly affects the surface heat transfer distribution. Spectral analysis of surface heat transfer signals has established the influence of the plume oscillations on the heat transfer. Thus, when the plume from the lower cylinder oscillates out of phase with the flow around the upper cylinder it increases the mixing and results in enhanced heat transfer. (author)

14 SOLAR ENERGY↗

Microwave Heating of a Liquid Stably Flowing in a Circular Channel Under the Conditions of Nonstationary Radiative-Convective Heat Transfer

A class of nonlinear problems of nonstationary radiative-convective heat transfer under the microwave action with a small penetration depth is considered in a stabilized coolant flow in a circular channel. The solutions to these problems are obtained, using asymptotic procedures at the stages of nonstationary and stationary convective heat transfer on the heat-radiating channel surface. The nonstationary and stationary stages of the solution are matched, using the 'longitudinal coordinate–time' characteristic. The approximate solutions constructed on such principles correlate reliably with the exact ones at the limiting values of the operation parameters, as well as with numerical and experimental data of other researchers. An important advantage of these solutions is that they allow the determination of the main regularities of the microwave and thermal radiation influence on convective heat transfer in a channel even before performing cumbersome calculations. It is shown that, irrespective of the heat exchange regime (nonstationary or stationary), the Nusselt number decreases and the rate of the surface temperature change increases with increase in the intensity of thermal action.

42 ENGINEERING↗

EXPERIMENTAL INVESTIGATION OF NATURAL CONVECTION HEAT TRANSFER OF IONIC LIQUID IN A RECTANGULAR ENCLOSURE HEATED FROM BELOW

This paper presents an experimental study of natural convection heat transfer for an Ionic Liquid. The experiments were performed for 1-butyl-2, 3-dimethylimidazolium bis(trifluoromethylsulfonyl)imide, ([C{sub 4}mmim][NTf{sub 2}]) at a Raleigh number range of 1.26 x 10{sup 7} to 8.3 x 10{sup 7}. In addition to determining the convective heat transfer coefficients, this study also included experimental determination of thermophysical properties of [C{sub 4}mmim][NTf{sub 2}] such as, density, viscosity, heat capacity, and thermal conductivity. The results show that the density of [C{sub 4}mmim][NTf{sub 2}] varies from 1.437-1.396 g/cm{sup 3} within the temperature range of 10-50 C, the thermal conductivity varies from 0.105-0.116 W/m.K between a temperature of 10 to 60 C, the heat capacity varies from 1.015 J/g.K - 1.760 J/g.K within temperature range of 25-340 C and the viscosity varies from 18cp-243cp within temperature range 10-75 C. The results for density, thermal conductivity, heat capacity, and viscosity were in close agreement with the values in the literature. Measured dimensionless Nusselt number was observed to be higher for the ionic liquid than that of DI water. This is expected as Nusselt number is the ratio of heat transfer by convection to conduction and the ionic liquid has lower thermal conductivity (approximately 18%) than DI water.

42 ENGINEERING↗

Experimental study of natural convective heat transfer in a vertical hexagonal sub channel

The development of new practices in nuclear reactor safety aspects and optimization of recent nuclear reactors, including the APWR and the PHWR reactors, needs a knowledge on natural convective heat transfer within sub-channels formed among several nuclear fuel rods or heat exchanger tubes. Unfortunately, the currently available empirical correlation equations for such heat transfer modes are limited and researches on convective heat transfer within a bundle of vertical cylinders (especially within the natural convection modes) are scarcely done. Although boundary layers around the heat exchanger cylinders or fuel rods may be dominated by their entry regions, most of available convection correlation equations are for fully developed boundary layers. Recently, an experimental study on natural convective heat transfer in a subchannel formed by several heated parallel cylinders that arranged in a hexagonal configuration has been being done. The study seeks for a new convection correlation for the natural convective heat transfer in the sub-channel formed among the hexagonal vertical cylinders. A new convective heat transfer correlation equation has been obtained from the study and compared to several similar equations in literatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convective heat transfer in the laminar-turbulent transition region with molten salt in a circular tube

In order to understand the heat transfer characteristics of molten salt and testify the validity of the well-known empirical convective heat transfer correlations, experimental study on transition convective heat transfer with molten salt in a circular tube was conducted. Molten salt circulations were realized and operated in a specially designed system over 1000 h. The average forced convective heat transfer coefficients of molten salt were determined by least-squares method based on the measured data of flow rates and temperatures. Finally, a heat transfer correlation of transition flow with molten salt in a circular tube was obtained and good agreement was observed between the experimental data of molten salt and the well-known correlations presented by Hausen and Gnielinski, respectively. (author)

36 MATERIALS SCIENCE↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗

Experimental study of forced convection heat transfer during upward and downward flow of helium at high pressure and high temperature

Fundamental high pressure/high temperature forced convection experiments have been conducted in support of the development of a Very High Temperature Reactor (VHTR) with a prismatic core. The experiments utilize a high temperature/high pressure gas flow test facility constructed for forced convection and natural circulation experiments. The test section has a single 16.8 mm ID flow channel in a 2.7 m long, 108 mm OD graphite column with four 2.3kW electric heater rods placed symmetrically around the flow channel. This experimental study presents the role of buoyancy forces in enhancing or reducing convection heat transfer for helium at high pressures up to 70 bar and high temperatures up to 873 degrees K. Wall temperatures have been compared among 10 cases covering the inlet Re numbers ranging from 500 to 3,000. Downward flows display higher and lower wall temperatures in the upstream and downstream regions, respectively, than the upward flow cases due to the influence of buoyancy forces. In the entrance region, convection heat transfer is reduced due to buoyancy leading to higher wall temperatures, while in the downstream region, buoyancyinduced mixing causes higher convection heat transfer and lower wall temperatures. However, their influences are reduced as the Reynolds number increases. This experimental study is of specific interest to VHTR design and validation of safety analysis codes.

Buoyancy↗

Experimental investigation of convection heat transfer of CO{sub 2} at supercritical pressures in a vertical circular tube

The convection heat transfer characteristics of supercritical CO{sub 2} in a vertical circular tube of 2 mm inner diameter were investigated experimentally for pressures ranging from 78 to 95 bar, inlet temperatures from 25 to 40 C, and inlet Reynolds numbers from 3800 to 20,000. The effects of the heat flux, thermo-physical properties, buoyancy and thermal acceleration on the convection heat transfer were analyzed. The experimental results show that for high inlet Reynolds numbers (e.g. Re = 9000) and high heat fluxes, a significant local deterioration and recovery of the heat transfer was found for upward flows but not for downward flows. Comparison of the experimental data for inlet Reynolds numbers from 3800 to 20,000 with some well-known empirical correlations showed large differences especially when the heat transfer deteriorates and then recovers when the effect of buoyancy is significant. The experimental data was used to develop modified local turbulent Nusselt number correlations for supercritical CO{sub 2} flowing in vertical small circular tubes. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of convection heat transfer on multiscale rough superhydrophobic and liquid infused surfaces

Multiscale rough superhydrophobic or slippery liquid infused porous surfaces have gained much interest in recent years for their improved transport phenomena properties. While there have been several studies on drag reduction and condensation on non-wetting surfaces, convection heat transfer that is important in many thermal and thermochemical applications has not been addressed systematically. Here, this article utilizes a fractal description of rough surface topographies to develop analytical models for the Nusselt number and the thermal hydraulic factor for fluid flow and heat transfer inside a cylinder with non-wetting surfaces. For air-infused superhydrophobic surfaces, the model considers the dynamic stability of the air/fluid interface in the asperities. Using the analytical formulations and the stability criteria, systematic studies are presented on the effects of the fractal surface parameters, cylinder radius and Reynolds number on the convective heat transfer characteristics, from which surface texture design maps are developed for maximizing the convection heat transfer. It is shown that multiscale non-wetting surfaces are most effective in the range of lower Reynolds number and small cylinder radius for achieving the best convective heat transfer and thermal hydraulic performance. Applying the models to actual non-wetting surface topographies fabricated using electrodeposition and chemical etching, it is shown that contrary to prevailing notion, superhydrophobicity, characterized by the highest contact angles, does not always lead to the maximum convective heat transfer performance, and that under certain fluid flow conditions, hydrophobic surfaces may offer a greater thermal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗