Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVERTED TEMPERATURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Kinetics and intermediate phases in epitaxial growth of Fe{sub 3}O{sub 4} films from deposition and thermal reduction

We have studied the kinetics of the transitions between the Fe{sub 2}O{sub 3} and Fe{sub 3}O{sub 4} phases as thin epilayers (∼2.5 nm) on Al{sub 2}O{sub 3} (001) substrates using time-resolved reflection high energy electron diffraction. The different iron oxide phases were identified using a combination of in-situ and ex-situ characterizations. The transition from an α-Fe{sub 2}O{sub 3} (001) epilayer to a Fe{sub 3}O{sub 4} (111) epilayer through thermal reduction was found to be determined by the Fe-O bonding energy, resulting in a long time scale. The oxidation at high temperature converts a Fe{sub 3}O{sub 4} (111) epilayer to an α-Fe{sub 2}O{sub 3} (001) epilayer quickly; at low temperature, a γ-Fe{sub 2}O{sub 3} (111) epilayer was slowly generated instead. By repeating the deposition/thermal reduction processes, a thicker Fe{sub 3}O{sub 4} (111) film was obtained, which exhibit high crystallinity and moderate magnetic coercivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Spin‐Crossover Systems to Enhance Thermopower and Thermoelectric Figure‐of‐Merit in Paramagnetic Materials

Thermoelectric materials, capable of converting temperature gradients into electrical power, have been traditionally limited by a trade‐off between thermopower and electrical conductivity. This study introduces a novel, broadly applicable approach that enhances both the spin‐driven thermopower and the thermoelectric figure‐of‐merit (zT) without compromising electrical conductivity, using temperature‐driven spin crossover. Our approach, supported by both theoretical and experimental evidence, is demonstrated through a case study of chromium doped‐manganese telluride, but is not confined to this material and can be extended to other magnetic materials. By introducing dopants to create a high crystal field and exploiting the entropy changes associated with temperature‐driven spin crossover, we achieved a significant increase in thermopower, by approximately 136 μV K −1 , representing more than a 200% enhancement at elevated temperatures within the paramagnetic domain. Our exploration of the bipolar semiconducting nature of these materials reveals that suppressing bipolar magnon/paramagnon‐drag thermopower is key to understanding and utilizing spin crossover‐driven thermopower. These findings, validated by inelastic neutron scattering, X‐ray photoemission spectroscopy, thermal transport, and energy conversion measurements, shed light on crucial material design parameters. We provide a comprehensive framework that analyzes the interplay between spin entropy, hopping transport, and magnon/paramagnon lifetimes, paving the way for the development of high‐performance spin‐driven thermoelectric materials.

magnons↗

Thermodynamic Modeling and Optimization of the Copper Flash Converting Process Using the Equilibrium Constant Method

Based on the principle of multiphase equilibrium, a mathematical model of the copper flash converting process was established by the equilibrium constant method, and a computational system was developed with the use of MetCal software platform. The mathematical model was validated by comparing simulated outputs, industrial data, and published data. To obtain high-quality blister copper, a low copper content in slag, and increased impurity removal rate, the model was then applied to investigate the effects of the operational parameters [oxygen/feed ratio (R{sub OF}), flux rate (R{sub F}), and converting temperature (T)] on the product weights, compositions, and the distribution behaviors of impurity elements. The optimized results showed that R{sub OF}, R{sub F}, and T should be controlled at approximately 156 Nm{sup 3}/t, within 3.0 pct, and at approximately 1523 K (1250 °C), respectively.

36 MATERIALS SCIENCE↗

Integrated three-dimensional characterization of reactive phase formation and coarsening during isothermal annealing of metastable Zn–3Mg–4Al eutectic

Microstructural instabilities associated with a metastable lamellar eutectic when exposed to an elevated temperature were analyzed in a Zn-3Mg-4Al alloy as a model system. X-ray diffraction and scanning electron microscopy showed that annealing at a temperature 43 K below the equilibrium eutectic temperature converted the metastable ternary MgZn 2 /η-Zn/β-ZnAl eutectic to a stable mixture of Mg 2 Zn 11 /η-Zn/α-Al. 3D EBSD suggested that supersaturation of η-Zn with Mg and Al eased difficulties in nucleation of Mg 2 Zn 11 and α-Al at the MgZn 2 /η-Zn phase interfaces. Quasi-in-situ X-ray nanotomography revealed that a reactive diffusion process prevailed in an early stage of annealing leading to rapid consumption of MgZn 2 for growth of Mg 2 Zn 11 and concomitant thinning and pinch-off of η-Zn lamellae. The reactive diffusion process also brought about significant and quantifiable changes in the topological characteristics of the η-Zn phase at remarkably shorter time scales compared to Rayleigh instability and Ostwald ripening mechanisms. Overall, the present results provide fresh insights on the short-term annealing effects on metastable eutectics, with relevance to structural evolution in additive manufacturing.

36 MATERIALS SCIENCE↗

Plasma-jet printing of colloidal thermoelectric Bi 2 Te 3 nanoflakes for flexible energy harvesting

Thermoelectric generators (TEGs) convert temperature differences into electrical power and are attractive among energy harvesting devices due to their autonomous and silent operation. While thermoelectric materials have undergone substantial improvements in material properties, a reliable and cost-effective fabrication method suitable for microgravity and space applications remains a challenge, particularly as commercial space flight and extended crewed space missions increase in frequency. This paper demonstrates the use of plasma-jet printing (PJP), a gravity-independent, electromagnetic field-assisted printing technology, to deposit colloidal thermoelectric nanoflakes with engineered nanopores onto flexible substrates at room temperature. We observe substantial improvements in material adhesion and flexibility with less than 2% and 11% variation in performance after 10 000 bending cycles over 25 mm and 8 mm radii of curvature, respectively, as compared to previously reported TE films. Our printed films demonstrate electrical conductivity of 2.5 × 10 3 S m -1 and a power factor of 70 μW m -1 K -2 at room temperature. To our knowledge, these are the first reported values of plasma-jet printed thermoelectric nanomaterial films. This advancement in plasma jet printing significantly promotes the development of nanoengineered 2D and layered materials not only for energy harvesting but also for the development of large-scale flexible electronics and sensors for both space and commercial applications.

99 GENERAL AND MISCELLANEOUS↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operando Temperature Measurements of Photovoltaic Laser Power Converter Devices Under Continuous High-Intensity Illumination

Photovoltaic devices that operate under extremely high irradiances, such as laser power converters (LPCs), may also operate at elevated temperatures, even under active cooling, as the result of large temperature gradients. We demonstrate the operation of GaAs LPC devices under orders of magnitude of irradiances up to 150 W/cm 2 in a monochromatic laser simulator with an active cooling stage. The steady-state open-circuit voltage (V OC ) as a function of irradiance is known to droop at high irradiance as the result of junction heating, but the junction temperature can be difficult to measure by conventional methods. Fast, transient V OC measurements under these extreme operating conditions are used here to determine the junction temperature. Empirical V OC temperature coefficients of the devices at each irradiance of interest are determined and used as an integral part of this technique. We show that the thermal design of different LPC devices strongly affects the operating temperature of the junctions. Knowledge of the operating temperature can be a strong tool for understanding the nature of loss mechanisms and improving the design for the operation of photovoltaic LPCs at high irradiances. Furthermore, this technique can be used for laboratory devices during initial design as well as to characterize mass-produced and packaged devices for quality control.

14 SOLAR ENERGY↗

Hybrid Temperature-Reactivity PID Controllers for Nuclear Thermal Propulsion Startup

In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.

33 ADVANCED PROPULSION SYSTEMS↗

Hybrid Temperature-Reactivity PID Controllers for Nuclear Thermal Propulsion Startup

In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

Upcycling Polyethylene Waste to Advanced Carbon Materials for Energy Storage Applications

Polyethylene is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into high-value carbon materials, such as graphene or graphite. We address this challenge by using an air-based, thermo-oxidation process, which heats polyethylene (PE) just below the decomposition point to initiate oxidation and cross-linking of PE alkyl chains. These molecular transformations allow PE to be further graphenized or graphitized at higher temperatures without decomposing. The PE-derived graphene has a specific surface area up to 1,800 m 2/g and Raman ID/IG ratio of 0.85, which enables it to be used as an electrode material for a symmetric supercapacitor with the 1 M H2SO4 electrolyte. The PE-derived graphene material has a comparable electrochemical capacitive performance, such as power density, specific capacitance, and long cycle stability, to the commercial state of art porous carbon electrode. The stabilized PE could also be converted into highly crystalline flake graphite via low-temperature catalytic graphitization. The PE-derived graphite is used for the lithium-ion battery anode, which showed comparable electrochemical battery performance, such as reversible rate performance and long-term cyclic stability, to the current use battery-grade graphite, thus providing a scalable method to upcycle PE plastic waste into high-value carbon material.

Gao, Yuan↗

Upcycling Polyethylene Waste Into Advanced Carbon Materials Used for Energy Storage Applications

Upcycling plastic into advanced carbons, such as graphite and graphene, offers attractive options to manage waste streams by converting the plastic into carbon electrode materials for energy storage devices. However, polyethylene (PE) is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into advanced carbons. This work addresses this challenge by oxidatively functionalizing PE between 300-330 C which stabilizes it for higher temperature processing into graphite & graphene. In addition, the graphite & graphene are tested as lithium-ion battery or supercapacitor electrodes where their electrochemical performances outperform commercial materials.

graphene↗

Upcycling Polyethylene Waste Into Advanced Carbon Materials Used for Energy Storage Applications

Upcycling plastic into advanced carbons, such as graphite and graphene, offers attractive options to manage waste streams by converting the plastic into carbon electrode materials for energy storage devices. However, polyethylene (PE) is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into advanced carbons. This work addresses this challenge by oxidatively functionalizing PE between 300-330 C which stabilizes it for higher temperature processing into graphite & graphene. In addition, the graphite & graphene are tested as lithium-ion battery or supercapacitor electrodes where their electrochemical performances outperform commercial materials.

graphene↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

The Kinetics of the Coherent Stage of Hydroxide Corrosion on Li 2 O-Covered LiH

The capability to model LiOH growth on vacuum-baked LiH is a necessary precursor to making kinetic predictions of undesirable hydrogen outgassing from corroded LiH materials when placed in sealed-system applications. Here, in this work, LiH samples with initial LiOH surface corrosion layers less than 1.1 μm were outgassed by vacuum baking at high temperature to convert LiOH to Li 2 O. Diffuse-reflectance infrared Fourier transform (DRIFT) spectroscopy was used to measure the subsequent LiOH regrowth during exposure to 25–375 ppm of H 2 O vapor at room temperature. Logarithmic kinetics best model the growth of this coherent hydroxide corrosion layer (up to 1.5 μm) on previously vacuum-baked LiH samples. The logarithmic kinetics are attributed to the dissociation of H 2 O on the corrosion layer and the establishment of a H + /OH – electric field across the thickening LiOH corrosion layer. A time-dependent model of LiOH corrosion growth as a function of both initial LiOH thickness before vacuum baking and moisture partial pressures during re-exposure was developed to help researchers better assess the unwanted hydrogen outgassing potential from LiH/LiD materials.

Matt, Sarah M. [Lawrence Livermore National Labora↗

Fluid–Solid Coupling Simulation on the Temperature Distribution of Tuyere Used for Oxygen Bottom Blowing Converter

For an oxygen bottom blowing converter, a high-temperature fire spot zone forms above the tuyere owing to oxygen reaction. The bottom blowing tuyere and surrounding brick are simultaneously heated by high-temperature fire spot and flowing molten steel. High-speed fluids flowing in the inner tube and the annular gap of the tuyere can remove part of the heat transferred from the fire spot zone and molten steel, playing a vital role in cooling the tuyere. To determine the temperature distributions of the tuyere and surrounding brick under the condition of oxygen bottom blowing, a fluid–solid coupling heat transfer numerical model that considers both the radiation of the fire spot and convection of the molten steel was established in this study. The simulation results agree well with previous experimental results; thus, the numerical model was validated. Utilizing the validated model, the influences of the tuyere inner tube material and fire spot zone temperature on the tuyere temperature distribution were studied in detail. Along with an increase in the material thermal conductivity, the maximum temperature of the inner tube at the hot face decreased, verifying the superiority of copper as the inner tube. More importantly, it was found that reducing the fire spot zone temperature by mixing CO{sub 2} in the bottom blowing oxygen fundamentally alleviated the burning loss of the tuyere and the surrounding brick.

36 MATERIALS SCIENCE↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗