Search NASA⌕ Search

SEARCH · Search NASA

Results for “COOLANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SPC-70791 Rev 0 MARVEL Inert Gas Subsystem, Secondary Coolant Management Subsystem, and Secondary Coolant Cover Gas Subsystem Tubing and Valve Specification

This specification covers the requirements and details for the selection, testing, cleaning, marking, shipping, inspection and installation (including welding) of the Inert Gas Subsystem, Secondary Coolant Management Subsystem, and Secondary Cover Gas Management Subsystem from the Valve Panel up to the classification division, the patch panel of the upper confinement. Including NaK, argon, eutectic gallium indium tin (eGaInSn), and helium fill tubing, valves, and hangers. These systems consist of the necessary straight lengths, elbows, reducers, fittings, tube connections, instrument taps, and valves called for by applicable drawings. All components shall be procured as ASME Section III Class 2 unless otherwise modified hereinafter. Pressure relief valves have been sized to prevent overpressure in the event there is full regulator flow. This is documented in ECAR-7365.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

HGP component with effusion cooling element having coolant swirling chamber

An effusion cooling element for the surface of a hot gas path (HGP) component is disclosed. The effusion cooling element includes a coolant swirling chamber embedded within the body of the HGP component. A coolant delivery passage is in the body and configured to deliver a coolant to the coolant swirling chamber. The coolant swirling chamber imparts a centrifugal force to the coolant. An effusion opening is in the HGP surface and in fluid communication with the coolant swirling chamber, the effusion opening having a smaller width than the coolant swirling chamber. The coolant exits the effusion opening over substantially all of 360° about the effusion opening, creating a coolant film on the HGP surface.

Berry, Jonathan Dwight↗

Actively controlled coolant tank to increase thermal storage capacity of hybrid electric vehicles

An engine and cabin thermal management system for use with a vehicle having an engine, a cabin heating system configured to thermally heat a cabin of the vehicle, a coolant system operably coupled to the engine and to the cabin heating system to thermally manage a temperature of the engine and a temperature of the cabin. The coolant system having one or more coolant thermal storage units fluidly coupled with a radiator and heater core of the coolant system forming a coolant loop. The system further having a control system configured to monitor and maintain at least a predetermined coolant temperature at the cabin heating system even during a coolant temperature decrease at the engine stops.

Amini, Mohammad Reza↗

Impact of coolant temperature on the combustion characteristics and emissions of a stratified-charge direct-injection spark-ignition engine fueled with E30

The direct injection spark ignition (DISI) engine has received considerable attention due to its potential to increase the power density of traditional spark ignition engines while significantly improving fuel economy through lean, unthrottled combustion. However, the market introduction of DISI engines operated in a lean combustion mode is inhibited by their unsatisfactory emissions, especially during cold start conditions that make proper mixture formation more challenging. Ethanol-blended gasoline, now a widely used fuel, makes the cold start of a DISI engine more difficult, leading to higher HC and soot emissions because of the high latent heat of vaporization of ethanol relative to gasoline. This work investigated the impact of coolant temperature on the characteristics of combustion and emissions in a stratified-charge DISI engine fueled with an E30 fuel (i.e. 30% ethanol in gasoline), while the coolant temperature was alternated between four levels (45, 60, 75, and 90 °C) to simulate different conditions throughout the warm-up process. The experiments showed that the coolant temperature affected the post-spark inflammation time, as well as the speed, intensity, and stability of the combustion process in the engine. When the coolant temperature rose, the engine produced more NOX and less CO, PM and HC. In addition, high-speed direct photography was used to obtain crank-angle resolved images of fuel sprays and flames in the cylinder. As the coolant temperature rose, the liquid spray lengths became shorter, reducing the possibility of wall wetting, and reduced irradiance from soot particles also indicated less nonpremixed combustion. The in-cylinder imaging results are consistent with the observed combustion and emission characteristics and shed light on the underlying processes. Finally, some potential solutions to the emissions challenges faced here could be either raising in-cylinder temperatures by using trapped residuals or modifying the injection schedule, for example by increasing the number of injections or to inject later in the cycle into a higher-density environment.

42 ENGINEERING↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Applying Infrared Thermography as a Method for Online Monitoring of Turbine Blade Coolant Flow

As gas turbine engine manufacturers strive to implement condition-based operation and maintenance, there is a need for blade monitoring strategies capable of early fault detection and root-cause determination. Given the importance of blade cooling flows to turbine blade health and longevity, there is a distinct lack of methodologies for coolant flowrate monitoring. The present study addresses this identified opportunity by applying an infrared thermography system on an engine-representative research turbine to generate data-driven models for prediction of blade coolant flowrate. Thermal images were used as inputs to a linear regression and regularization algorithm to relate blade surface temperature distribution with blade coolant flowrate. Additionally, this study investigates how coolant flowrate prediction accuracy is influenced by the number and breadth of diagnostic measurements. Here, the results of this study indicate that a source of high-fidelity training data can be used to predict blade coolant flowrate within about six percent error. Furthermore, identification of prioritized sensor placement supports application of this technique across multiple sensor technologies capable of measuring blade surface temperature in operating gas turbine engines, including spatially resolved and point-based measurement techniques.

42 ENGINEERING↗

A Critical Review of High Burnup Fuel Fragmentation, Relocation, and Dispersal under Loss-Of-Coolant Accident Conditions

High burnup fuel in excess of ~6268 GWd/MTU has been observed to severely fragment when subjected to temperature transient conditions as in a loss-of-coolant accident. In the event of cladding failure, the severely fragmented fuel can relocate into the balloon region and potentially disperse through the burst opening into the reactor’s primary system. This observation has led to implementation of several independent test programs designed to focus on various aspects of fuel fragmentation, relocation, and dispersal. The purpose of this review is to perform a critical, holistic assessment of fuel fragmentation, relocation, and dispersal under loss-of-coolant conditions to identify data gaps in the experimental data base. Phenomena have been identified and well defined through the various testing programs, and general agreement regarding the governing parameters (temperature, burnup, heating rate, cladding deformation, etc.) has been established. However, there is a significant data gap connecting research to commercial application. Furthermore, previous research attempted to evaluate the problem holistically, but has yet to provide a comprehensive understanding of the problem. Major identified data gaps consist of (1) a comprehensive understanding of pretransient fuel rod conditions (fuel temperature, fuel stress, rod internal pressures, microstructure, etc.), (2) definition of prototypic loss-of-coolant accident conditions (heating rate, fuel temperatures, fuel stress), (3) identification of the differences between nuclear and electrical integral loss-of-coolant accident tests, and connection of fuel rod performance (cladding ballooning, burst opening, potential relocation, fragmentation susceptibility, etc.) to fuel fragmentation, relocation, and dispersal severity. Finally, the content of this manuscript provides a clear path for connecting testing and data acquisition to commercial application by providing concrete means for filling data gaps and prioritized testing regimes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Comparison of Helium and sCO 2 as Coolants for Modular Finger-Type Divertors

Several studies at the Georgia Institute of Technology have evaluated the thermal and fluids performance of the helium-cooled modular divertor with multiple jets (HEMJ) over the past decade. This finger-type divertor was studied both experimentally at nearly prototypical conditions and numerically at fully prototypical operating conditions using experimentally validated simulations. Recently, supercritical carbon dioxide (sCO 2 ) has been studied as the primary coolant in power cycles and other applications in various systems, in part because CO 2 achieves the high densities typical of supercritical fluids at relatively low temperatures and pressures, with a critical point of (7.38 MPa, 31°C). This density makes it possible to realize very compact and efficient sCO 2 power cycles. The feasibility of sCO 2 as a coolant for plasma-facing components, specifically the divertor, was therefore evaluated as part of the Fusion Energy System Studies design study activities. This work compares the thermal-fluid performance of helium and sCO 2 in the HEMJ divertor geometry using numerical simulations at prototypical conditions: inlet temperatures T i = 600°C to 700°C, pressures p ≈ 10 MPa, and steady-state incident heat fluxes on the tile q″ < 17 MW/m 2 . The performance is quantified here as the maximum heat flux that can be accommodated by the plasma-facing tile, the pumping power fraction, defined as the ratio of the coolant pumping power to the incident thermal power, and the operating stress limits based on ASME pressure vessel criteria. As expected, helium requires lower mass flow rates and pumping power fractions within imposed maximum temperature limits for the HEMJ pressure boundary. However, it also appears that neither helium nor sCO 2 can remove 10 MW/m 2 of incident heat flux while meeting ASME pressure vessel criteria. Finally, the numerical modeling reveals that sCO 2 may remove slightly higher incident heat fluxes than helium due to the imposed stress limits due to the sCO 2 coolant resulting in smaller local temperature gradients, albeit at a considerably higher pumping power fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Consideration of alternative coolants in AGR-like FHR designs

Replacing carbon-dioxide coolant in AGR-like reactor with molten salt significantly affects the reactor performance characteristics. Hence, a new core design is needed. In this work, a Multi-Objective Particle Swarm Optimisation is used to identify the most favourable configurations for a new system layout. The performed analysis examines each configuration with respect to its thermal-hydraulic performance to assess the power uprate potential which is limited by multiple temperature constraints (e.g. fuel centreline and cladding temperatures as well as the coolant freezing/boiling). The estimated maximum power was then used in the fuel burnup calculations, from which a discharge burnup and cycle average Coolant Temperature Coefficients (CTC) were obtained. As a result of the optimisation process, several families of possible solutions were identified, which form an optimal Pareto Front. The most attractive configurations in terms of achievable power density, however, were not necessarily on the Pareto front. Several coolant options are examined and compared in this paper. The newly identified design options have the potential to achieve power density that is higher than that of a typical AGR by up to a factor of five while maintaining negative CTC through the burnup cycle. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of Fuel-to-Coolant Heat Transfer During Reactivity-Initiated Accidents Using Tightly Coupled Thermal Hydraulics and Fuel Thermomechanics

The reactivity-initiated accident (RIA) is a complex scenario with several tightly interacting physical phenomena. Accurately predicting fuel behavior during these transients is difficult due to limitations in the modeling of fuel-to-coolant heat transfer. Common approaches to simulate RIAs involve standalone calculations using either a fuel performance code or a thermal-hydraulic code. The complex interdependencies of thermal-hydraulic and fuel mechanical behavior suggest that a tight coupling between these codes may provide more accurate predictions of fuel-to-coolant heat transfer and cladding mechanical response. Here, RELAP5-3D and BISON are coupled in this paper to simulate RIAs, and a sensitivity analysis is performed to rank key thermal properties and two-phase heat transfer parameters relevant for fuel-to-coolant heat transfer and cladding failure mechanisms in UO 2 –Zircaloy-4 systems. Gas gap conductance, film boiling heat transfer uncertainty, pulse width, fuel-specific heat capacity, and cladding-specific heat capacity were identified as important parameters. Variations in figures of merit resulting from changes to pulse width and the material thermal properties indicate that time-dependent heat transfer rates are significant for safety-relevant mechanical parameters due to the time dependence of cladding ductility and pellet-cladding mechanical interaction loading. The results suggest that the thermal-hydraulic factors have a nonnegligible influence on the thermomechanical solution and vice versa. Tight coupling of both sets of physics is recommended to improve prediction of fuel behavior during RIAs. Highlights include the following: 1. The RELAP5-3D thermal-hydraulic code and the BISON fuel performance code are tightly coupled for simulation of RIA transients with energy depositions at the Zircaloy-4 cladding failure threshold. 2. Departure from nucleate boiling occurred for all simulated cases. Due to the ductility of fresh fuel, substantial ballooning occurred in most cases. 3. Gas gap conductance, fuel-specific heat capacity, cladding-specific heat capacity, transient pulse width, and film boiling heat transfer were the dominant thermal factors impacting the safety figures of merit at energy depositions.

Critical Heat Flux (CHF)↗

HIGH BURNUP FUEL-COOLANT INTERACTION ANALYSIS SUPPORTING FUEL SAFETY TESTING AT IDAHO NATIONAL LABORATORY

In the near future, experiments on HBu fuel under loss-of-coolant accident (LOCA) and reactivity-initiated accident (RIA) conditions will be performed within the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL). These experiments will be performed using the Transient Water Irradiation System for TREAT (TWIST) experiment vehicle. To support these experiments, analysis of fuel-coolant interaction (FCI) energetics is underway. This paper discusses FCIs in the context of light water reactor (LWR) safety, differentiating between the severe accident focus of commercial reactors and experimental RIA test programs where FCIs have occurred. However, it is highlighted that as the nuclear industry aims for increased burnup limits, the FCI events observed in RIA test programs may become relevant to commercial LWR safety analysis. The paper then presents developments to the UW-FCI computer program to enable simulation of FCIs initiated by solid fuel particles dispersing into the coolant during RIAs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coolant Pump Predictive Data Analytics from Signatures Generated by the Recursive Short Time Fast Fourier Transform

Although a nuclear reactor is a hostile environment for sensors and signal transmissions, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure installed at the Advanced Test Reactor (ATR) nozzle trench area records acoustic signals that can capture reactor operating states. The distinct states produce unique signatures that can be identified and tracked using data processing and data analytics. The infrastructure relies on acoustic transmission through ATR in-pile structural components, piping, and coolant that transmit acoustically modified signals generated by the coolant pumps. This paper will discuss results from using the Recursive Short Time Fast Fourier Transform (RSTFFT) technique used to process acoustic signals and provide signatures that are identified and monitored by analytics. The RSTFFT is applied to ATR data to understand the vibration levels and signatures for different operating regimes as displayed by the spectrogram. The combination of coolant pumps for normal and high-power operation generate unique signatures. These acoustic signatures are used to develop machine learning approaches to automatically classify operating regimes. Two machine-learning models, Support Vector Machines and Linear Discriminant Analysis, were developed to classify two event classes. Class 1 is a normal steady-state operation, and Class 2 is any event that is due to start up, shut down, or other actions. Both types of machine learning models had over a 96% prediction accuracy for the two classes. These results lay the foundation for predictive analytic frameworks that can be leveraged by ATR to optimize operations and maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Analysis of Coolant Stream Impurity Gamma Emissions in Gas-Cooled Fast Reactors

It is well established that a rapid increase in the concentration of fission products in the reactor coolant stream can serve as an early indication of fuel failure. We use Monte Carlo simulations to investigate the feasibility of using several gamma detectors as diagnostic equipment to monitor the presence of major fission product isotopes in high-temperature gas-cooled reactor (HTGR) coolant streams for early detection of fuel failure and therefore the prevention of fuel failure conditions. Herein we model the response of high-purity germanium (HPGe), CdZnTe, NaI(Tl), and LaBr 3 (Ce) detectors of typical commercial sizes to the gamma emissions from nuclides expected to be found within the coolant stream of the Versatile Test Reactor (VTR) under development by the U.S. Department of Energy. The results indicate that for the 233- and 250-keV gamma rays from 133 Xe and 135 Xe, respectively, the 3σ detection criterion is met in under 1 min using a single HPGe detector. Changes in other spectral lines associated with Xe nuclides are detected within 1 h regardless of the choice of detector.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multiphysics Analysis of Li Cooled Divertor Substrate During Loss of Coolant Accident (LOCA)

In the ongoing study of potential designs for liquid metal (LM) plasma-facing components (PFCs), so-called “slow” and “fast” Li flow divertor concepts are under investigation. In the previous studies on design and analysis of the slow Li flow divertor and comparison with the fast Li flow divertor, the magnetohydrodynamics (MHD)/heat transfer effects of the Li flowing inside the substrate as a second coolant were comprehensively investigated under the normal steady-state operation conditions. Here, in the present study, the multiphysics analysis is extended to the unsteady abnormal divertor scenario where the Li layer on top of the substrate does not provide full coverage or even totally disappears for a certain period of time, so that the substrate becomes directly exposed to the incident high plasma heat flux. Such an unwanted event may happen regardless of the concept of the divertor and is worth detailed investigations, typically referred to as a loss of coolant accident (LOCA). To address this situation, a simplified scoping analysis is conducted first in 2-D, and then an integrated 3-D modeling is performed using a time-dependent multiphysics model in COMSOL Multiphysics that integrates LM MHD, heat transfer, and solid mechanics. The main goal is to evaluate conditions under which the major material limits, such as the maximum allowable temperature, stress, and displacement of the substrate, can still be met. It was shown that the maximum time over which the substrate of RAFM steel can retain structural integrity during the LOCA is around 0.2 ∼ 0.3 s. Any divertor concept that utilizes RAFM steel as a substrate material and liquid Li as a second coolant should take such a permitted time into consideration.

divertor↗

Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Water Coolant Pool

Mechanistic assessments of radionuclide release during postulated accidents are expected to be included in advanced reactor license applications. The mechanistic source term (MST) provides an opportunity for vendors to realistically evaluate the radiological consequences of an incident, and may aid in justifying reduced emergency planning zones and plant sites. However, the development of MSTs for advanced nuclear reactors is challenging because there are numerous phenomena that can affect the transport and retention of radionuclides. As part of a trial MST assessment for a metal-fueled, pool-type sodium cooled fast reactor (SFR), led by Argonne National Laboratory, a simplified radionuclide transport code (SRT code) was developed, which includes models to estimate the quantity of fission product aerosols scrubbed in the sodium pool during postulated accident scenarios. In a pool-type SFR, when fission products are released into the coolant pool due to failure of fuel pins, most of the radionuclides are scrubbed by the coolant pool, but some have the potential to migrate to the cover gas region through entrainment within gas bubbles. The SRT code contains a model that evaluates this scrubbing behavior and calculates the fraction of fission product aerosols that reach the cover gas. Due to a lack of available validation data for sodium pool scrubbing, the U.S. Department of Energy funded an experiment at the University of Wisconsin-Madison to measure aerosol scrubbing by injecting air bubbles containing aerosol into a coolant pool. Prior to performing an experiment with liquid sodium, a water loop experiment was performed. Their experiment evaluated the effect of changing the aerosol size, aerosol density, aerosol concentration, bubble size, and pool depth on the aerosol scrubbing efficiency of the pool. In this benchmark experiment, the base tests were conducted by repeated tests of isolated bubbles. Afterwards, more prototypic tests with bubble swarms were performed to evaluate the interactions between the bubbles. The bubble swarm test was able to confirm that a larger amount of aerosol scrubbing occurred than the single bubble test. It was also confirmed that as the bubble size, aerosol density, and pool height increase, the extent of pool scrubbing also increases and does not change with the aerosol concentration. In addition, since the degree of scrubbing is the lowest at aerosol sizes between 0.01 and 1 μm, that is, the largest amount of aerosol is emitted, it was confirmed that the analysis of this size in MST is the most important. This benchmark experiment informs the direction of future sodium experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗