Search NASA⌕ Search

SEARCH · Search NASA

Results for “COPPER 61”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A = 61

The evaluated spectroscopic data are presented for known nuclides of mass 61 (Sc,Ti,V,Cr,Mn,Fe,Co,Ni, Cu,Zn,Ga,Ge). Excited-state data are nonexistent for {sup 61}Sc, {sup 61}Ti, {sup 61}V, and {sup 61}Ge. Significant amounts of new data have been added since the previous NDS evaluation of A=61 nuclides (1999Bh04). {sup 61}Sc nuclide is now experimentally known, but without any knowledge of its half-life. The ground state half-lives of {sup 61}Ti and {sup 61}V are now determined. Excited-state data have become available for {sup 61}Cr, {sup 61}Mn and {sup 61}Ga, while for {sup 61}Ge, five excited states were erroneously assigned in the previous evaluation, these have been omitted here. Improved and extensive high-spin excitations are available for {sup 61}Fe, {sup 61}Cu and {sup 61}Zn, including several new superdeformed structures in {sup 61}Cu and {sup 61}Zn. Thermal neutron capture γ-ray data are available in detail from 2004Ra23. The radioactive decay schemes of {sup 61}Sc and {sup 61}Ti are not known, while those for {sup 61}V, {sup 61}Fe and {sup 61}Ge are poorly known. This work benefited from the earlier full evaluations of A=61 published by 1999Bh04, 1983Ek01 and 1975Au05 and the one published in an ‘update’ mode by 1992Zh31. The data and conclusions presented in the current work supersede those in all the previous evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the experimental level scheme of {sup 61}Cu using computational technique

The high-spin structure in {sup 61}Cu nucleus is studied in terms of effective two body interaction. In order to take into account the deformed BCS basis, the basis states are expanded in terms of the core eigenfunctions. Yrast band with some other bands havew been obtained and back-bending in moment of inertia has also been calculated and compared with the available experimental data for {sup 61}Cu nucleus. On comparing the available experimental as well as other theoretical data, it is found that the treatment with PSM provides a satisfactory explanation of the available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of band structure of {sup 103,105}Rh using microscopic computational technique

The high-spin structure in {sup 61}Cu nucleus is studied in terms of effective two body interaction. In order to take into account the deformed BCS basis, the basis states are expanded in terms of the core eigenfunctions. Yrast band with some other bands havew been obtained and back-bending in moment of inertia has also been calculated and compared with the available experimental data for {sup 61}Cu nucleus. On comparing the available experimental as well as other theoretical data, it is found that the treatment with PSM provides a satisfactory explanation of the available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase 1 Trial of Bevacizumab With Concurrent Chemoradiation Therapy for Squamous Cell Carcinoma of the Head and Neck With Exploratory Functional Imaging of Tumor Hypoxia, Proliferation, and Perfusion

Purpose: A phase 1 trial was completed to examine the safety and feasibility of combining bevacizumab with radiation and cisplatin in patients with locoregionally advanced squamous cell carcinoma of the head and neck (HNSCC) treated with curative intent. Additionally, we assessed the capacity of bevacizumab to induce an early tumor response as measured by a series of biological imaging studies. Methods and Materials: All patients received a single induction dose of bevacizumab (15 mg/kg) delivered 3 weeks (±3 days) before the initiation of chemoradiation therapy. After the initial dose of bevacizumab, comprehensive head and neck chemoradiation therapy was delivered with curative intent to 70 Gy in 33 fractions with concurrent weekly cisplatin at 30 mg/m{sup 2} and bevacizumab every 3 weeks (weeks 1, 4, 7) with dose escalation from 5 to 10 to 15 mg/kg. All patients underwent experimental imaging with [{sup 18}F]fluorothymidine positron emission tomography (FLT-PET) (proliferation), [{sup 61}Cu]Cu-diacetyl-bis(N4-methylthiosemicarbazone) PET (Cu-ATSM-PET) (hypoxia), and dynamic contrast-enhanced computed tomography (DCE-CT) (perfusion) at 3 time points: before bevacizumab monotherapy, after bevacizumab monotherapy, and during the combined therapy course. Results: Ten patients were enrolled. All had stage IV HNSCC, all achieved a complete response to treatment, and 9 of 10 remain alive, with a mean survival time of 61.3 months. All patients experienced grade 3 toxicity, but no dose-limiting toxicities or significant bleeding episodes were observed. Significant reductions were noted in tumor proliferation (FLT-PET), tumor hypoxia (Cu-ATSM-PET), and DCE-CT contrast enhancement after bevacizumab monotherapy, with further decreases in FLT-PET and Cu-ATSM-PET during the combined therapy course. Conclusions: The incorporation of bevacizumab into comprehensive chemoradiation therapy regimens for patients with HNSCC appears safe and feasible. Experimental imaging demonstrates measureable changes in tumor proliferation, hypoxia, and perfusion after bevacizumab monotherapy and during chemoradiation therapy. These findings suggest opportunities to preview the clinical outcomes for individual patients and thereby design personalized therapy approaches in future trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production of GMP-Compliant Clinical Amounts of Copper-61 Radiopharmaceuticals from Liquid Targets

PET imaging has gained significant momentum in the last few years, especially in the area of oncology, with an increasing focus on metal radioisotopes owing to their versatile chemistry and favourable physical properties. Copper-61 (t1/2 = 3.33 h, 61% β+, Emax = 1.216 MeV) provides unique advantages versus the current clinical standard (i.e., gallium-68) even though, until now, no clinical amounts of 61Cu-based radiopharmaceuticals, other than thiosemicarbazone-based molecules, have been produced. This study aimed to establish a routine production, using a standard medical cyclotron, for a series of widely used somatostatin analogues, currently labelled with gallium-68, that could benefit from the improved characteristics of copper-61. We describe two possible routes to produce the radiopharmaceutical precursor, either from natural zinc or enriched zinc-64 liquid targets and further synthesis of [61Cu]Cu-DOTA-NOC, [61Cu]Cu-DOTA-TOC and [61Cu]Cu-DOTA-TATE with a fully automated GMP-compliant process. The production from enriched targets leads to twice the amount of activity (3.28 ± 0.41 GBq vs. 1.84 ± 0.24 GBq at EOB) and higher radionuclidic purity (99.97% vs. 98.49% at EOB). Our results demonstrate, for the first time, that clinical doses of 61Cu-based radiopharmaceuticals can easily be obtained in centres with a typical biomedical cyclotron optimised to produce 18F-based radiopharmaceuticals.

Fonseca, Alexandra I. (ORCID:000000031924178X)↗

Deep Learning Accelerated Determination of Hydride Locations in Metal Nanoclusters

Abstract Although the coordinates of the metal atoms can be accurately determined by X‐ray crystallography, locations of hydrides in metal nanoclusters are challenging to determine. In principle, neutron crystallography can be employed to pinpoint the hydride positions, but it requires a large crystal and a neutron source, which prevents its routine use. Here, we present a deep‐learning approach that can accelerate determination of hydride locations in single‐crystal X‐ray structure of metal nanoclusters of different sizes. We demonstrate the efficiency of our method in predicting the most probable hydride sites and their combinations to determine the total structure for two recently reported copper nanoclusters, [Cu 25 H 10 (SPhCl 2 ) 18 ] 3− and [Cu 61 (S t Bu) 26 S 6 Cl 6 H 14 ] + whose hydride locations have not been determined by neutron diffraction. Our method can be generalized and applied to other metal systems, thereby eliminating a bottleneck in atomically precise metal hydride nanochemistry.

Wang, Song↗

Deep Learning Accelerated Determination of Hydride Locations in Metal Nanoclusters

Although the coordinates of the metal atoms can be accurately determined by X-ray crystallography, locations of hydrides in metal nanoclusters are challenging to determine. In principle, neutron crystallography can be employed to pinpoint the hydride positions, but it requires a large crystal and a neutron source, which prevents its routine use. Here, we present a deep-learning approach that can accelerate determination of hydride locations in single-crystal X-ray structure of metal nanoclusters of different sizes. We demonstrate the efficiency of our method in predicting the most probable hydride sites and their combinations to determine the total structure for two recently reported copper nanoclusters, [Cu 25 H 10 (SPhCl 2 ) 18 ] 3- and [Cu 61 (S t Bu) 26 S 6 Cl 6 H 14 ] + whose hydride locations have not been determined by neutron diffraction. Our method can be generalized and applied to other metal systems, thereby eliminating a bottleneck in atomically precise metal hydride nanochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-H-CAMPUS-TeP1-04: Novel 3D Printed Plastic Cutouts Filled with Aluminum Oxide for Same Day Electron Radiotherapy

Purpose: Clinics that outsource electron cutout manufacturing may be unable to simulate and treat patients on the same day. To enable same day treatment, we investigate the use of 3D printed hollow cutouts filled with 30 grit Al{sub 2}O{sub 3} powder. We verified the dosimetric equivalence of such a cutout relative to an outsourced Copper cutout. Methods: Printing was performed using a Ultibots Kossel 250 V-Slot 3D printer and polylactic acid filament. Printing files were derived from an in-house 3D model designed to mate with a Varian 6 cm electron cone. Relative to conventional cutouts (Copper or Cerrobend), the height of the hollow plastic cutout was extended by 1.0 cm to increase attenuation. Measurements were performed for 6 MeV in solid water at dmax (1.4 cm) with Gafchromic™ EBT3 film; the cutout was kidney-shaped with a long and short axis of approximately 5 and 2 cm, respectively. The Copper cutout was based on an outline of the 3D printed cutout.A calibration film was exposed immediately after the electron irradiations. All films, including an un-irradiated one, were from the same batch. Films were scanned on an Epson 10000XL flatbed scanner. Film analysis was performed in DoseLab (MOBIUS Medical Systems, Houston, Tx). Results: Visual comparison of the physical cutouts revealed that the Copper cutout had a slightly smaller opening than the printed cutout. Line profiles through the registered films indicated agreement within 5% in the open section. 99.9% of pixels passed gamma analysis with 2% local percent difference, 2 mm DTA, and a 25% threshold. Conclusion: Same day simulation and treatment with electrons is feasible with 3D printing of a hollow cutout filled with Al{sub 2}O{sub 3}. Future work will include evaluations of additional cutout shapes at different depths for higher energies. Other printing materials, such as bismuth, are being tested.

60 APPLIED LIFE SCIENCES↗

TL-OSL study of Li{sub 3}PO{sub 4}: Mg, Cu phosphor

In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li{sub 3}PO{sub 4} phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li{sub 3}PO{sub 4} shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

36 MATERIALS SCIENCE↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-412: Evaluation of Tungsten-Based Functional Paper for Attenuation Device in Intraoperative Radiotherapy for Breast Cancer

Purpose: Intraoperative radiotherapy (IORT) with an electron beam is one of the accelerated partial breast irradiation methods that have recently been used in early-stage breast cancer. A protective acrylic resin-copper disk is inserted between the breast tissue and the pectoralis muscle to minimize the dose received by the posterior structures. However, a problem with this protective disk is that the surgical incision must be larger than the field size because the disk is manufactured from stiff and unyielding materials. The purpose of this study was to assess the applicability of a new tungsten-based functional paper (TFP) as an alternative to the existing protective disk in IORT. Methods: The newly introduced TFP (Toppan Printing Co., Ltd., Tokyo, JP) is anticipated to become a useful device that is lead-free, light, flexible, and easily processed. The radiation shielding performance of TFP was verified by experimental measurements and Monte Carlo (MC) simulations using PHITS code. The doses transmitted through the protective disk or TFP were measured on a Mobetron mobile accelerator. The same geometries were then reproduced, and the dose distributions were simulated by the MC method. Results: The percentages of transmitted dose relative to the absence of the existing protective disk were lower than 2% in both the measurements and MC simulations. In the experimental measurements, the percentages of transmitted dose for a 9 MeV electron beam were 48.1, 2.3, and 0.6% with TFP thicknesses of 1.9, 3.7, and 7.4 mm, respectively. The percentages for a 12 MeV were 76.0, 49.3, 20.0, and 5.5% with TFP thicknesses of 1.9, 3.7, 7.4, and 14.8 mm, respectively. The results of the MC simulation showed a slight dose increase at the incident surface of the TFP caused by backscattered radiation. Conclusion: The results indicate that a small-incision procedure may be possible by the use of TFP.

60 APPLIED LIFE SCIENCES↗

SU-E-T-474: Improvements to Intra-Oral Shield Design for Electron Beam Treatments: Use of Multi-Layered Metal Foils

Purpose: Intraoral electron shields used in radiotherapy are designed to minimize radiation exposure to non-treatment tissue. Sites where shields are used include but are not limited to, the treatment of lips, cheeks and ears whilst shielding the underlying oral cavity, tongue, gingival or temporal region. However their use produces an enhancement in dose on the beam side caused by an increase in electron backscatter radiation. This work designs a new shield incorporating copper, aluminium and wax in a step down filter arrangement to minimise backscatter whilst minimizing overall shield thickness. Methods: For electron beams ranging from 6 MeV to 10 MeV, shields of varying designs and thicknesses were assessed to determine the thinnest shield design that could be produced whilst minimising backscattered radiation to a clinically acceptable level. This was performed with conventional lead and wax shields as well as varying quantities of aluminium and copper foils. Results: From tested shield designs, a new shield design of 4 mm lead, 0.6 mm copper, 1.0 mm aluminium and 1.5 mm wax (3.1 mm added filtration, 7.1 mm total thickness) provided a clinically acceptable (no greater than 110% dose) backscatter and transmission reduction and matched a standard 4.5 mm lead and 10 mm wax (total thickness 14.5 mm) electron shield. Dose enhancement values of no more than 10 % were measured utilising this shield design with a 50 % reduction in shield thickness. Conclusion: The thinner layered shield reduced backscattered radiation dose to less than 10% enhancement for beam energies on 10 MeV and less and will allow easier patient set up. The thinner shields are tolerated better by patients when mucosal reactions occur as they place less physical pressure on these sites during treatment due to their smaller size and thickness.

60 APPLIED LIFE SCIENCES↗

Effect of biquadratic coupling on current induced magnetization switching in Co/Cu/Ni-Fe nanopillar

The effect of biquadratic coupling on spin current induced magnetization switching in a Co/Cu/Ni-Fe nanopillar device is investigated by solving the free layer magnetization switching dynamics governed by the Landau-Lifshitz-Gilbert-Slonczewski (LLGS) equation. The LLGS equation is numerically solved by using Runge-Kutta fourth order procedure for an applied current density of 5 × 10{sup 12} Am{sup -2}. Presence of biquadratic coupling in the ferromagnetic layers reduces the magnetization switching time of the nanopillar device from 61 ps to 49 ps.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

TU-H-206-02: Novel Linearly-Filled Derenzo PET Phantom Design

Purpose: To design a linearly-filled Derenzo positron emission tomography (PET) phantom, eliminating the extraneous radioisotope volumes in a conventional reservoir-type design. This activity reduction combined with the elimination of bubbles in smaller phantom channels would significantly reduce personnel dose, radioisotope cost, and would improve image quality by reducing out-of-slice activity scatter. Methods: A computer-aided design (CAD) was created of a modular Derenzo phantom consisting of three phantom layers with gaskets between the layers. The central piece contains the active pattern volume and channels connecting adjacent rods in a serpentine pattern. The two end-pieces contained an inlet and an outlet for filling purposes. Phantom prototypes were 3D printed on a Viper Si2 stereolithography machine. The two gaskets were fabricated from silicon sheets using a PLS 6.75 laser cutter. Phantoms were held together by pass-through glass-filled nylon bolts and nuts. Phantoms were filled with {sup 52}Mn, {sup 64}Cu, {sup 74}Br, and {sup 124}I for testing, and were imaged on a Siemens Inveon MicroPET scanner. Results: Four phantom prototypes were constructed using male Leur Lock fittings for inlet/outlet ports. 3D printed layers were sanded to ensure proper coupling to the silicon gaskets. The filling volume for each prototype was approximately 2.4 mL. The filling process was found to be rapid, leak-tight, and with minimal back-pressure. PET images were reconstructed by OSEM3D, and axial slices along the phantom pattern length were averaged to provide final images. Image distortion was isotope dependent with {sup 52}Mn and {sup 64}Cu having the least distortion and {sup 124}I having the most distortion. Conclusion: These results indicate that the linearlyfilled Derenzo design improves on conventional reservoir-type designs by eliminating potential bubbles in small channels and by reducing activity level, radioisotope volume, radioisotope cost, personnel dose, filling time, and out-of-slice activity scatter The method described in this abstract has been filed as a patent application to the US Patent and Trade Office by the Wisconsin Alumni Research Foundation (WARF).

60 APPLIED LIFE SCIENCES↗

980-nm, 15-W cw laser diodes on F-mount-type heat sinks

We have studied the key optical emission parameters of laser diodes (emission wavelength, 980 nm; stripe contact width, 95 μm) mounted directly on F- and C-mount-type copper heat sinks, without intermediate elements (submounts). When effectively cooled by a thermoelectric microcooler, the lasers on the F-mount operated stably at output powers up to 20 W. The lasers were tested for reliable operation at an output power of 15 W for 100 h, and no decrease in output power was detected to within measurement accuracy. The experimentally determined maximum total efficiency is 71.7% and the efficiency at a nominal output power of 15 W is 61%. We compare parameters of the laser diodes mounted on C- and F-mounts and discuss the advantages of the F-mounts. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Copper and zinc levels in soil, water, wheat, and hair of inhabitants of three areas of the Orenburg region, Russia

Highlights: • Soil, water, wheat and hair levels of Zn and Cu in Orenburg region were studied. • Both Zn and Cu levels in the samples were higher in the eastern area. • Higher levels of Zn and Cu in the eastern area may occur due to industrial activities. • Water Zn levels were associated with hair Zn levels. The objective of the present study was to assess the level of zinc and copper in soil, water, wheat and hair of inhabitants of the western, central, and eastern areas of the Orenburg region. A total of 525 water, soil, and wheat samples, as well as 420 hair samples were assessed using atomic absorption spectrometry (water, soil, wheat) and inductively-coupled plasma mass spectrometry (hair). The highest levels of Zn and Cu in water (4.9(4.2–5.1) and 1.0(0.9–1.1) mg/l), soil (23.8(20.7–27.0) and 2.6(1.9–3.1) mg/kg), and wheat (24.7(20.5–31.0) and 4.8(4.2–5.5) mg/kg) were observed in the eastern area (p < 0.001). Hair zinc levels in inhabitants of the western (184(165–198) µg/g) and eastern (224(211–253) µg/g) areas of the region exceeded the respective values from the central area by 32% and 61% (p < 0.001). In turn, hair Cu levels in the central (16.4(14.3–17.8) µg/g) and eastern (17.9(16.4–19.0) µg/g) areas exceeded the values from the western area by 10% and 20%, respectively. Correlation analysis demonstrated that hair Zn levels were positively correlated with water and soil content, whereas wheat Zn levels were associated with soil and water content. For copper significant direct correlation was observed only between soil and water Cu content. In multiple regression models, only water zinc level was significantly associated with hair Zn content, although the general model accounted for 55% of variability of hair Zn content. Higher zinc and copper exposure in the eastern area is presumably associated with higher activity of metal-processing industry.

54 ENVIRONMENTAL SCIENCES↗

Competing conduction mechanisms in high performance carbon nanotube fibers

The performance of carbon nanotube (CNT) cables, a contender for copper-wire replacement, is tied to its metallic and semi-conducting-like conductivity responses with temperature; the origin of the semi-conducting-like response however is an underappreciated incongruity in literature. With controlled aspect-ratio and doping-degree, over 61 unique cryogenic experiments including anisotropy and Hall measurements, CNT cable performance is explored at extreme temperatures (65 mK) and magnetic-fields (60 T). A semi-conducting-like conductivity response with temperature becomes temperature-independent approaching absolute-zero, uniquely demonstrating for the first time the necessity of heterogeneous fluctuation induced tunneling; complete de-doping leads to localized hopping, contrasting graphite's pure metallic-like response. High-field magneto-resistance (including novel +22 % longitudinal magneto-resistance near room-temperature) is analyzed with hopping and classical two-band models, both yielding a similar parameter useful for conductor development. Varying field-orientation angle uncovers significant two- and four-fold symmetries that are shown to be from Aharonov-Bohm-like corrections to the curvature-induced bandgap, a first for macroscale CNT fibers. Tight-binding calculations using Green's Function formalism model the largest, coherent transport to-date in commensurate CNT bundles in magnetic-field, revealing non-uniform transmission across bundle cross-sections with doping restoring uniformity; independent of doping, transport in bundle-junction-bundle systems are predominantly from CNTs adjacent to the other bundle—demonstrating that smaller bundles are more efficient for electronic transport. The final impact is predicting the ultimate conductivity of heterogeneous CNT cables using temperature and field-dependent transport, surpassing conductivity of traditional metals.

36 MATERIALS SCIENCE↗

SU-F-I-76: Fluoroscopic X-Ray Beam Profiles for Spectra Incorporating Copper Filtration

Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.

60 APPLIED LIFE SCIENCES↗