Search NASA⌕ Search

SEARCH · Search NASA

Results for “COPPER DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface purity control during XMASS detector refurbishment

The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of an ultra-low-background proportional counter for measuring {sup 37}Ar

An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent production of the K{sup +}π{sup 0} system by K{sup +} mesons on copper nuclei in the OKA detector

In a sample of ∼5 × 10{sup 9} positive kaon collisions with copper nuclei, the events of coherent production of K{sup +}π{sup 0} pairs are selected, the contributions of the Coulomb and strong production mechanisms are discriminated, and the corresponding cross sections are determined. The phase shift difference between the Coulomb and strong amplitudes is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations for Tracking Cosmogenic Activation in Germanium and Copper

High-purity germanium (HPGe) detectors housed in copper cryostats and shielding materials are used in measurements of the extraordinarily rare nuclear decay process, neutrinoless double-beta decay (0νββ), and for dark matter searches. Cosmogenic production of 68Ge and 60Co in the germanium and copper represent an irreducible background to these experiments as the subsequent decays of these isotopes can mimic the signals of interest. These radioactive isotopes can be removed by chemical and/or isotopic separation, but begin to grow-in to the material after separation until the material is moved deep underground. This work is motivated by the need to have a reliable, experimentally benchmarked simulation tool for evaluating shielding materials used during transportation and near-surface manufacturing of experiment components. The resulting simulations tool has been used to enhance the effectiveness of an existing transport shield used to ship enriched germanium from the separations facility to the detector manufacturing facility.

Aguayo, Estanislao↗

Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.

low noise↗

Nuclear activation analysis of zirconium-90 isomeric and ground-state reactions at the OMEGA Laser Facility

Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.

Activation analysis↗

Response of an implantable MOSFET dosimeter to {sup 192}Ir HDR radiation

New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with {sup 192}Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector response. The detectors exhibited a higher sensitivity to {sup 192}Ir energies than {sup 60}Co energies. A nonlinear accumulated dose effect was characterized by three third-order polynomials fit to data from detectors placed at three different distances from the source. The detectors were found to have minimal rotational angular dependence. A strong longitudinal angular dependence was found when the detector's copper coil and electronics assembly were aligned between the MOSFETs and incident radiation. This orientation showed a 16% decrease in response relative to other orientations tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Majorana Project

Working as part of a collaborative team, PNNL is bringing its signature capability in ultra-low-level detection to help search for a rare form of radioactive decay-never before detected-called "neutrinoless double beta decay" in germanium. If observed, it would demonstrate neutrinos are Majorana-type particles. This discovery would show neutrinos are unique among fundamental particles, having a property whereby the matter and anti-matter version of this particle are indistinguishable. Physicist John L. Orrell explains how they rely on the Shallow Underground Laboratory to conduct the research.

74 ATOMIC AND MOLECULAR PHYSICS↗

A preliminary investigation into the electrodeposition and synthesis of radiopure Copper–Chromium alloys for rare-event physics detector systems

Current investigations into neutrinoless double beta decay and the direct detection of dark matter require increasingly sensitive detector systems that demand ultra-low background materials. These requirements have previously been attained using ultra-radiopure electroformed (EF) copper. However, pure copper possesses high ductility and relatively low strength, which necessitates the need for large amounts of material and extra care during fabrication to help minimize galling and mechanical failure. Furthermore, we investigate an alloying alternative to pure EF copper by examining low wt% copper chrome (Cu–Cr) solid solution alloys, with inquiries into alloy hardness, strength, and radiopurity. Alloyed Cu–Cr layered samples are shown to exhibit significantly increased hardness compared to EF copper, for example showing a 50% increase in exhibited hardness using less than 1% Cr by weight, with limited negative impact to the material’s radiopurity.

Background↗

Heavy Nucleus Collector (HNC) project for the NASA Long Duration Exposure Facility (LDEF)

The primary goal of the heavy nucleus collector (HNC) experiment was to obtain high resolution composition measurements for cosmic ray nuclei in the platinum-lead and actinide region of the periodic table. Secondary objectives include studies of selected groups of elements of lower charge. These goals were to be realized by orbiting a large area array of dielectric nuclear track detectors in space for several years. In this time sufficient actinide nuclei would be collected to determine the nucleosynthetic age of the cosmic radiation and the relative mix of r- and s-process elements in the cosmic ray source. The detector consists of approximately 50 trays assembled in pressurized canisters. Each tray would contain 8 half-stacks (4 stacks total) and an event thermometer which would record the temperature of each event at the time of exposure. Each stack would contain 7 layers of Rodyne-P, CR-39 and Cronar plastic track detectors interleaved with copper stripping foils. Upon return to Earth, detectors would be removed for analysis. Ultraheavy nuclei would have left tracks through the detector sheets that would be made visible after etching in a hot sodium hydroxide solution.

Tarle, Gregory↗

Ultraviolet corona detection sensor study

The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

Schmitt, R. J.↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

First result of the experimental search for the 9.4 keV solar axion reactions with {sup 83}Kr in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches of Russian Academy of Science (BNO INR RAS). It is assumed that axions are created in the Sun during M1 transition between the first thermally excited level at 9.4 keV and the ground state in {sup 83}Kr. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m{sub A} ≤ 130 eV at 95% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗