Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSIVE EFFECTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of Radiation-Induced Defects on Corrosion

The next generation of nuclear reactors will expose materials to conditions that, in some cases, are even more extreme than those in current fission reactors, inevitably leading to new materials science challenges. Radiation-induced damage and corrosion are two key phenomena that must be understood both independently and synergistically, but their interactions are often convoluted. In the light water reactor community, a tremendous amount of work has been done to illuminate irradiation-corrosion effects, and similar efforts are under way for heavy liquid metal and molten salt environments. While certain effects, such as radiolysis and irradiation-assisted stress corrosion cracking, are reasonably well established, the basic science of how irradiation-induced defects in the base material and the corrosion layer influence the corrosion process still presents many unanswered questions. In this review, we summarize the work that has been done to understand these coupled extremes, highlight the complex nature of this problem, and identify key knowledge gaps.

36 MATERIALS SCIENCE↗

Corrosive Effects of Burning Fuels

Literature synthesized to develop corrosion predictions for unconventional fuels. Report presents studies of probable corrosive effects of such unconventional fuels as liquefied coal. Report prepared by analyzing probable composition of fuels when they come into wide use, identifying important compounds, and searching literature for information about corrosion problems associated with compounds in environments like those in industrial and commercial boilers and furnaces.

Bellan, J.↗

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗

Corrosion Effects of Calcium Chloride Injection for Mercury Control on the Pollution Control Equipment

In response to the Clean Air Mercury Rule (CAMR) of 2005, Black Hills Power (BHP) initiated testing of a calcium chloride (CaCl{sub 2}) injection method in their Wygen 1 (Gillette, WY) coal-fired power plant to help lower mercury emissions. In 2006, Babcock & Wilcox (B&W) was contracted to test their CaCl{sub 2} technology in-situ by adding a CaCl{sub 2} solution onto the raw, pre-pulverized coal during normal operation of Wygen 1. Follow-up tests were conducted by BHP in 2007. Data were collected from these two time periods and analyzed by a collaborative investigation team from Western Research Institute (WRI) and the University of Wyoming (UW) to see if there were any effects on the current air pollution control systems. During a CaCl{sub 2} injection period in 2007, corrosion was monitored in the flue and recycle ash system by placing corrosion coupons in strategic locations to test if corrosion was enhanced by the CaCl{sub 2} injection. While the CaCl{sub 2} produced a reduction in stack mercury levels, there was some evidence of beneficial impacts on the removal of SO{sub 2} from the flue gas during CaCl{sub 2} injection. Data on NOx remained inconclusive. It was also discovered that corrosion was enhanced significantly in the Spray Drier Absorber (SDA) vessel and corresponding outlet ductwork during CaCl{sub 2} injections. Further studies are being carried out in the field and lab to better understand the corrosive effects of CaCl{sub 2} to help formulate operation controls to manage the increased corrosion rates.

01 COAL, LIGNITE, AND PEAT↗

The corrosion effects of neutron activation of 2LiF-BeF 2 (FLiBe)

The redox effect of activation reactions in molten salts has been previously qualitatively defined but never quantified. Here, we quantify the corrosion effects of neutron activation of FLiBe. Rates of change of activation products are computed for FHR and ARC. The impact of activation reactions on salt chemistry is quantitatively compared to other environmental effects of similar consequences on the salt. The results are applied to a redox control case-study and an irradiation-corrosion experiment. The results are presented in a manner useful to the reactor chemist and designer concerned with corrosion and chemistry control and tritium management in irradiated FLiBe, and design of salt-irradiation experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating Corrosion Effects on the Stainless Steel Components of the SAVY-4000/Hagan Nuclear Material Storage Containers

Surveillance of vented, stainless-steel Hagan and SAVY-4000 storage containers with some plutonium materials has revealed evidence of corrosion inside the container. There are ~3000 items stored in Hagan containers and ~600 items currently stored in SAVY-4000 containers at TA -55. The Hagan is made of 304L steel, while the SAVY-4000 is made of 316L and should be less susceptible to corrosion. Given the relatively thin body wall of these containers (nominally 0.762 millimeters), it is essential to understand the effects of corrosion on the lifetime of the containers to ensure worker safety. Studies are being conducted on both container types to determine the relative susceptibility of the two containers to corrosion. This paper describes the potential cause of corrosion, the extent of corrosion, and types of corrosion observed, along with the results of accelerated aging experiments. The combined results of the surveillance and lifetime extension studies establish a technical basis for extending the design life of the stainless steel components of the SAVY-4000 container from 5 years to 15 years.

36 MATERIALS SCIENCE↗

Electrochemical and galvanic corrosion effects in thin-film photovoltaic modules

The electrochemical and galvanic corrosion properties of thin-film photovoltaic (TF-PV) modules and module subcomponents are determined and interpreted in the light of established corrosion science. Results of a detailed study of thin-film aluminum metallization corrosion are presented. Bar-graph corrosion, observed in fielded modules, has been induced experimentally and found to be electrochemical in nature. Corrosion rates and passivation techniques for TF-PV modules are discussed.

Mon, G.↗

Evaluating Corrosion Effects on the Stainless Steel Components of the SAVY-4000/Hagan Nuclear Material Storage Containers: FY19 Update

This report provides an update of the FY19 corrosion observations, laboratory studies, and mitigation efforts for the nuclear material storage program at Los Alamos National Laboratory. Nuclear material packages outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging.1 The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology as a manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating Corrosion Effects on the Stainless Steel Components of the SAVY-4000/Hagan Nuclear Material Storage Containers: FY2022 Update

This report summarizes the work completed and underway for the Corrosion Working Group (CWG) for FY2022 in support of evaluating a greater than a 15 year design life for the SAVY4000. The CWG meets on an as needed basis to review new work, results or information regarding the corrosion of SAVY-4000 and Hagan nuclear material storage containers. The goal when analyzing corrosion is to develop a design life appropriate for the containers and to identify when a container should be removed from service. There are many parallel efforts associated with identifying and extending the service life of nuclear material storage containers. This report includes information from research and development efforts to address the lifetime. The CWG is closely related to surveillance activities and continues to play a role in identification of issues and paths forward for analysis of surveillance containers. This work summarizes the completed tasks for FY22 of the CWG while keeping in mind that some efforts continue into future years. Brief summaries of identified new avenues of work have been identified for FY23.

36 MATERIALS SCIENCE↗

Probing the initial stages of iron surface corrosion: Effect of O 2 and H 2 O on surface carbonation

Iron plays a vital role in natural processes such as water, mineral, iron, and nutrient cycles. Iron undergoes reduction-oxidation and catalytic reactions to produce various corrosion films depending on its chemical environment. Near ambient pressure X-ray photoelectron spectroscopy, polarized modulated infrared reflection absorption spectroscopy, and Auger electron spectroscopy were used to study the key reactants, from O 2 (g), H 2 O vapor, Na + and Cl – on the initial stages of iron surface corrosion. Here, with increasing the ratio of O 2 and H 2 O, surface hydrocarbons were shown to oxidize into carbonates, while the Cl – was found to migrate into the interface. The effect of each individual reactant was measured separately and water was shown to have a first order rate dependence on the carbonate growth at low pressures, with little dependence for O 2 . Near ambient pressures, both H 2 O and O 2 were found to increase the carbonate growth, which was estimated using the Langmuir isotherm model, yielding Gibbs energies between –9.8 to –8.5 kJ/mol. A mechanism is suggested to explain the oxidation is catalyzed by NaCl on iron surfaces and the adventitious hydrocarbons served as the source for surface carbonation. These findings have implications for understanding other surface catalytic and redox interface chemistry in complex environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DEPOSITION TANK CORROSION TESTING FOR ENHANCED CHEMICAL CLEANING POST OXALIC ACID DESTRUCTION

An Enhanced Chemical Cleaning (ECC) process is being developed to aid in the high level waste tank closure at the Savannah River Site. The ECC process uses an advanced oxidation process (AOP) to destroy the oxalic acid that is used to remove residual sludge from a waste tank prior to closure. The AOP process treats the dissolved sludge with ozone to decompose the oxalic acid through reactions with hydroxyl radicals. The effluent from this oxalic acid decomposition is to be sent to a Type III waste tank and may be corrosive to these tanks. As part of the hazardous simulant testing that was conducted at the ECC vendor location, corrosion testing was conducted to determine the general corrosion rate for the deposition tank and to assess the susceptibility to localized corrosion, especially pitting. Both of these factors impact the calculation of hydrogen gas generation and the structural integrity of the tanks, which are considered safety class functions. The testing consisted of immersion and electrochemical testing of A537 carbon steel, the material of construction of Type III tanks, and 304L stainless steel, the material of construction for transfer piping. Tests were conducted in solutions removed from the destruction loop of the prototype ECC set up. Hazardous simulants, which were manufactured at SRNL, were used as representative sludges for F-area and H-area waste tanks. Oxalic acid concentrations of 1 and 2.5% were used to dissolve the sludge as a feed to the ECC process. Test solutions included the uninhibited effluent, as well as the effluent treated for corrosion control. The corrosion control options included mixing with an inhibited supernate and the addition of hydroxide. Evaporation of the uninhibited effluent was also tested since it may have a positive impact on reducing corrosion. All corrosion testing was conducted at 50 C. The uninhibited effluent was found to increase the corrosion rate by an order of magnitude from less than 1 mil per year (mpy) for an inhibited waste to a range of 5 to 23.4 mpy, depending on sludge chemistry. F-area-based effluents were, in general, more corrosive. Effective corrosion control measures included evaporation, hydroxide additions and mixing with supernates containing a representative supernate chemistry (5 M hydroxide and 1.5 M nitrite). Corrosion rates with these measures were generally 0.2 mpy. The A537 carbon steel was found to be susceptible to pitting when the corrosion control measure involved mixing the ECC effluent with a supernate chemistry having minimal inhibitor concentrations (0.5 M hydroxide and 0.3 M nitrite). Corrosion rates in this case were near 1 mpy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Embrittlement of Duralumin VI The Effect of Corrosion Accompanied by Stress on the Tensile Properties of Sheet Duralumin

The effect of corrosion on the tensile properties of duralumin while stressed is shown in graphical form. According to the test results, duralumin sheet, coated with aluminum, maintains its initial properties unimpaired for corrosion periods as long as 60 days with an applied tensile stress as high as 20,000 lb/sq.in., which is approximately one-half the stress corresponding to the yield point as defined here. In these tests, that material which had been heat-treated by being quenched in cold water, though far inferior to similar material having the aluminum coating, was superior to the sheet material which was heat treated by being quenched in hot water. These results are in excellent agreement with the results of previous laboratory and exposure tests.

Rawdon, Henry S↗