Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Comparison between two Aitken counters and with cloud condensation nuclei counters at the 1980 International CCN Workshop

The Pollak and the TSI 3020 counters agreed to within about 10% at concentrations below 1000 cu cm, whereas above that concentration, substantial systematic differences were observed. When the test aerosol was monodisperse and the CCN counters were operated at supersaturations that should nucleate all the aerosol, the Pollak counter read about 6% to 20% lower than the CCN counter in the concentration range from 250/cu cm to 1800/cu cm. The TSI 3020 read about 20% lower than the CCN counter at concentrations less than 1000/cu cm, and a factor of about two higher at concentrations above 1000/cu cm.

Rogers, C. F.↗

High resolution time interval counter

In recent years, we have developed two types of high resolution, multi-channel time interval counters. In the NIST two-way time transfer MODEM application, the counter is designed for operating primarily in the interrupt-driven mode, with 3 start channels and 3 stop channels. The intended start and stop signals are 1 PPS, although other frequencies can also be applied to start and stop the count. The time interval counters used in the NIST Frequency Measurement and Analysis System are implemented with 7 start channels and 7 stop channels. Four of the 7 start channels are devoted to the frequencies of 1 MHz, 5 MHz or 10 MHz, while triggering signals to all other start and stop channels can range from 1 PPS to 100 kHz. Time interval interpolation plays a key role in achieving the high resolution time interval measurements for both counters. With a 10 MHz time base, both counters demonstrate a single-shot resolution of better than 40 ps, and a stability of better than 5 x 10(exp -12) (sigma(sub chi)(tau)) after self test of 1000 seconds). The maximum rate of time interval measurements (with no dead time) is 1.0 kHz for the counter used in the MODEM application and is 2.0 kHz for the counter used in the Frequency Measurement and Analysis System. The counters are implemented as plug-in units for an AT-compatible personal computer. This configuration provides an efficient way of using a computer not only to control and operate the counters, but also to store and process measured data.

Zhang, Victor S.↗

The response of a scintillation counter below an emulsion chamber to heavy nucleus interactions in the chamber

In 1982 a hybrid electronic counter-emulsion chamber experiment was flown on a balloon to study heavy nucleus interactions in the 20 to approximately 100 GeV/AMU energy range. A gas Cerenkov counter, two solid Cerenkov counters, and a proportional counter hodoscope gave the primary energy, the primary charge and the trajectory of the particles, respectively. Using the trajectory information cosmic ray nuclei of Z 10 were found reliably and efficiently, and interaction characteristics of the Fe group nuclei were measured in the chamber. A plastic scintillator below the emulsion chamber responded to showers resulting from interactions in the chamber and to noninteracting nuclei. Data on the response of the counter have been compared with simulations of hadronic-electromagnetic cascades to derive the average neutral energy fraction released by the heavy interactions, and to predict the performance of this kind of counter at higher energies. For the interacting events of highest produced particles multiplicity comparison between various simulations and the shower counter signal have been made.

Burnett, T. H.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

Real-time garbage collection for list processing using restructured cells for increased reference counter size

In a list processing system, small reference counters are maintained in conjunction with memory cells for the purpose of identifying memory cells that become available for re-use. The counters are updated as references to the cells are created and destroyed, and when a counter of a cell is decremented to logical zero the cell is immediately returned to a list of free cells. In those cases where a counter must be incremented beyond the maximum value that can be represented in a small counter, the cell is restructured so that the additional reference count can be represented. The restructuring involves allocating an additional cell, distributing counter, tag, and pointer information among the two cells, and linking both cells appropriately into the existing list structure.

Shuler, Jr., Robert L.↗

Redundant operation of counter modules

A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

Nagano, S.↗

Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

Giffin, Rollin George↗

UH-60A Airloads Flight Test Program: Data Counter 9505

The data collection portion of the UH-60A Airloads Flight Test Program (ref. 1) was conducted between July 1993 and February 1994. At the time, the UH-60A Airloads Program was the most comprehensive and data-rich rotorcraft flight test program that NASA and the U.S. Army had ever attempted. It was part of the Modern Technology Rotors Program (ref. 2), where several different rotors were tested in small- and full-scale wind tunnels combined with flight testing. The UH-60A portion of this program allowed for comparison between other tests performed and served as a scientific quality database for validating current and new computational and simulation models. The UH-60A flight test data was stored in a comprehensive, easily accessed database known as the Tilt Rotor Engineering Database System, or TRENDS (ref. 3). With over 30 years of rotor testing experience (ref. 4), NASA and the Army’s goal of the Airloads Flight Test Program was to collect data for a wide range of operating conditions, and to provide an extensive amount of data to improve the understanding of rotors and validate and improve prediction codes. This report presents the entire archived data set from Counter 9505 (Run 95, point 5) from the UH-60A Airloads Flight Test Program. There were 1,078 total data set counters acquired and archived during 57 accumulated flight hours and 31 research flights. Over 900 counters were research flight data acquisition data points. Counter 9505 is a low altitude, moderate airspeed, level-flight test condition. Ground acoustic microphone data was acquired for this counter but the acoustic data is not included in this report.

Kufeld, Robert M.↗

Digital frequency counter permits readout without disturbing counting process

Digital frequency counter system enables readout accurately at one-second intervals without interrupting or disturbing the counting process. The system incorporates a master counter and a slave counter with novel logic interconnections. The counter can be readily adapted to provide frequency readouts at 0.1 second intervals.

Winkelstein, R.↗

The effect of delta ray production on Cerenkov counter response

Light generated by delta rays in Cerenkov counters contributes to the mean counter signal in addition to producing fluctuations in this signal. The dependence of this contribution on the energy of the primary particle deviates significantly from the Cerenkov formula. When using such a counter to measure the index of a typical cosmic ray power law spectrum, neglect of this effect can yield a value for the spectral index which is too high by 0.3. This paper presents calculations of this delta ray contribution as a function of the energy of the primary particle. It points out the need for accurate and independent determination of such experimental parameters as counter resolution (intrinsic and statistical), linearity, and normalization.

Evenson, P.↗

Some characteristics of powder silica counters

Following the original idea of Peters, techniques have been developed to fabricate large area powder silica counters with refractive index between 1.06 to 1.12 in thicknesses of 1 cm and 2 cm respectively. The maximum size counter is 25 cm x 25 cm but the technique can be easily extended to 40 cm x 30 cm counters. Techniques have also been developed to dope this counter with the wavelength shifter p-terphenyl uniformly. The results of test runs at the Brookhaven National Laboratory and of laboratory runs using a superconducting magnet spectrometer on their performance are reported.

Badhwar, G. D.↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

Low-speed wind-tunnel tests of single- and counter-rotation propellers

A low-speed (Mach 0 to 0.3) wind-tunnel investigation was conducted to determine the basic performance, force and moment characteristics, and flow-field velocities of single- and counter-rotation propellers. Compared with the eight-blade single-rotation propeller, a four- by four- (4 x 4) blade counter-rotation propeller with the same blade design produced substantially higher thrust coefficients for the same blade angles and advance ratios. The results further indicated that ingestion of the wake from a supporting pylon for a pusher configuration produced no significant change in the propeller thrust performance for either the single- or counter-rotation propellers. A two-component laser velocimeter (LV) system was used to make detailed measurements of the propeller flow fields. Results show increasing slipstream velocities with increasing blade angle and decreasing advance ratio. Flow-field measurements for the counter-rotation propeller show that the rear propeller turned the flow in the opposite direction from the front propeller and, therefore, could eliminate the swirl component of velocity, as would be expected.

Dunham, D. M.↗

Unsteady forces on counter-rotating propeller blades

Unsteady forces experienced by counter-rotating propeller blades are examined in this paper. A fully coupled vortex lattice model of counter-rotation is used to obtain a quasi-steady solution to the propeller loadings, and an unsteady Sears (1941) analysis provides an estimate of the unsteady loads from the quasi-steady results. The vortex lattice method predicts the overall performance of counter-rotation well, based on comparisons of measured and predicted results. The effects of propeller spacing and blade number on the unsteady loadings are investigated. The peak-to-peak variation about the mean of the unsteady loads on the rear propeller varied from 9 percent for a 2 x 2 counter-rotation system to 2 percent for an 8 x 8 system.

Lesieutre, D. J.↗

Advanced Prop-fan Engine Technology (APET) single- and counter-rotation gearbox/pitch change mechanism

The preliminary design of advanced technology (1992) turboprop engines for single-rotation prop-fans and conceptual designs of pitch change mechanisms for single- and counter-rotation prop-fan application are discussed. The single-rotation gearbox is a split path, in-line configuration. The counter-rotation gearbox is an in-line, differential planetary design. The pitch change mechanisms for both the single- and counter-rotation arrangements are rotary/hydraulic. The advanced technology single-rotation gearbox yields a 2.4 percent improvement in aircraft fuel burn and a one percent improvement in operating cost relative to a current technology gearbox. The 1992 counter-rotation gearbox is 15 percent lighter, 15 percent more reliable, 5 percent lower in cost, and 45 percent lower in maintenance cost than the 1992 single-rotation gearbox. The pitch controls are modular, accessible, and external.

Reynolds, C. N.↗

Apparatus for using a time interval counter to measure frequency stability

An apparatus for measuring the relative stability of two signals is disclosed comprising a means for mixing the two signals down to a beat note sine wave and for producing a beat note square wave whose upcrossings are the same as the sine wave. A source of reference frequency is supplied to a clock divider and interval counter to synchronize them and to generate a picket fence for providing a time reference grid of period shorter than the beat period. An interval counter is employed to make a preliminary measurement between successive upcrossings of the beat note square wave for providing an approximate time interval therebetween as a reference. The beat note square wave and the picket fence are then provided to the interval counter to provide an output consisting of the time difference between the upcrossing of each beat note square wave cycle and the next picket fence pulse such that the counter is ready for each upcrossing and dead time is avoided. A computer containing an algorithm for calculating the exact times of the beat note upcrossings then computes the upcrossing times.

Greenhall, Charles A.↗