Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cloud Particle Imager (CPI) and 3-View Cloud Particle Imager (3V-CPI) Instrument Handbook

The cloud particle imager (CPI) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring the concentration and size of cloud droplet and ice crystals. Hydrometeors entering the tube will be detected by a system of two continuous wave lasers that are perpendicular to each other, monitoring the sample volume. When a hydrometeor obscures both laser beams it is inside the sample volume and a third laser is triggered to illuminate the hydrometeor and a camera records a two-dimensional image. The CPI records images with a resolution of 2.3 μm. Since the camera has 1024 x 1024 pixels, the maximum detectable size is 2.3 mm x 2.3 mm.

54 ENVIRONMENTAL SCIENCES↗

Further characterization of Closed Pore Insulation (CPI)

The thermophysical and mechanical properties of closed pore insulation (CPI) were measured after exposure to 25 simulated reentry thermal cycles. In addition, mechanical properties were obtained at elevated temperatures before and after cycling. The properties of CPI were not compromised by the cycling. High temperature creep studies were done on three CPI compositions (4, 8, and 12 Wt% CoO additive). CPI-4 had the best creep resistance at temperatures up to 1363 K.

Russak, M.↗

LARC-CPI, a new semi-crystalline polyimide

As part of a program on high performance/high temperature structural resins for aerospace applications, work was performed with a new semi-crystalline polyimide (LARC-CPI) to improve the compression moldability while retaining high mechanical properties and thermooxidative stability. Various molecular weight versions of LARC-CPI polyamide acid were prepared, end-capped with different groups, converted to polyimide and evaluated for film properties, thermooxidative stability and melt flow. One controlled molecular weight, end-capped version of LARC-CPI was evaluated more comprehensively in adhesive and composite work and exhibited good compression moldability, reasonable crystallization rates and high mechanical properties.

Hergenrother, P. M.↗

Adhesive properties of LARC-CPI, a new semi-crystalline polyimide

As part of an effort on high temperature structural resins for aerospace applications, a new family of polyimides containing carbon and ether connecting groups between aromatic rings were prepared. Several of these polyimides were semicrystalline. One polyimide, designated LARC-CPI, with a glass transition temperature of 222 C and a crystalline melt temperature of 350 C, was evaluated in the form of an adhesive, film, and molding. Unoriented films exhibited excellent resistance to solvents and strong bases and high tensile properties. Compact tension specimens gave very high fracture toughness values. Titanium tensile shear specimens provided exceptional strength under a variety of test conditions. The chemistry and the physical and mechanical properties of LARC-CPI are discussed.

Hergenrother, P. M.↗

Chemistry and properties of controlled molecular weight end-capped LaRC-CPI

As part of a program on structural resins for high temperature aerospace applications, a controlled molecular weight end-capped semi-crystalline polyimide, designated LaRC-CPI, was evaluated. Neat resin moldings, adhesive specimens and composites were fabricated at temperatures of 365-375 C under pressures of 200-500 psi. Adhesive and composite specimens provided good mechanical properties at temperatures as high as 232 C.

Hergenrother, Paul M.↗

Development and Characterization of CPI Surface Insulation

A new type of reusable surface material that could find application as a component of the thermal protection system of the space shuttle orbiter is discussed. These materials consist of 20-30% dense closed cell high emittance glass ceramic foams formulated by sintering an intimate mixture of fly ash cenospheres with 4-12 wt % cobalt oxide. These unique ceramic foams exhibit: (1) High mechanical strengths; (2) no need for waterproof coating due to the non-interconnecting cell network; (3) high emissivities; (4) ability to withstand space shuttle thermal environments with no loss of reuse capability; and (5) a machinable ceramic with capability of maintaining the close tolerances required of an integrated heat shield system.

Tobin, A.↗

Hot-Carrier Injection and Millisecond Charge Separation from a Robust Heteroleptic Iron(II) Chromophore Immobilized on TiO 2

The synthesis, spectroscopic characterization, computational analysis, and photoelectrochemical behavior of a new iron-based chromophore, [(Cpy) 2 Fe- (deeb)](PF 6 ) 2 (Fe(Cpy) 2 (deeb)), where Cpy is 1-methyl-3-(2-pyridyl)imidazole and deeb is 4,4’-(CO 2 CH 2 CH 3 ) 2 -2,2’-bipyridine, is reported. Electrochemically reversible waves assigned to a metal-centered E o (Fe III/II ) = +0.48 and a ligand-centered E o (Fe 2+/+ ) = −1.47 V vs Fc +/0 reduction were evident in cyclic voltammetry measurements. The combination of a strong σ-donor and a π-acceptor lowered the energy of the metal-toligand charge-transfer (MLCT) excited state relative to the metal-centered state. Two MLCT transitions appear in the visible region at 424 and 580 nm. TDDFT calculations revealed that the lower-energy band was well formulated as Fe(II)→deeb, and the higher-energy transition was charge transfer to both the deeb and Cpy ligands. Resonance Raman spectroscopy supports these findings showing enhanced deeb vibrational modes with 532 nm excitation, both deeb and Cpy modes with 473 nm excitation, and exclusively Cpy with 405 nm excitation. Ultrafast spectroscopy reveals a short-lived (∼2 ps) MLCT excited state and a longer-lived (∼20 ps) metal-centered state. Efficient methods to deprotect the ester groups and anchor the complex to mesoporous TiO 2 (anatase) thin films in high surface coverages, Fe(Cpy) 2 (dcb)|TiO 2 σ = 3 × 10 −8 mol/cm 2 , were established. Pulsed light excitation of Fe(Cpy) 2 (dcb)|TiO 2 resulted in rapid excited state injection (k inj > 10 8 s −1 ) and formation of a charge-separated state, Fe III (Cpy) 2 (dcb)|TiO 2 (e), which persists on the millisecond time scale before returning cleanly to the ground state with secondorder kinetics. Injection yields measured 50 ns after light excitation were found to double from Φ = 0.15 with green (532 nm) light to 0.30 with blue (457 nm) light excitation. Incident photon-to-current efficiency (% IPCE) measurements as a function of excitation wavelength in a 0.5 M LiI/I 2 /CH 3 CN electrolyte provide clear evidence for band-selective “hot carrier” injection from the remote Cpy-localized excited state. Collectively, the spectroscopic and photoelectrochemical data indicate that a semiconductor can intercept hot electrons from iron chromophores even when the excited-state dipole is oriented away from the surface-anchoring ligand.

Charge transfer↗

Effects of 9.5 Years of Whole-Soil Warming on the Fatty Acid and n-Alkanes Composition in Bulk Soil and Density Fractions at Blodgett Experimental Forest, California, USA

Original data of molecular data (fatty acids and n-alkanes) including concentrations and calculated molecular proxies in a whole-soil warming experiment at the Blodgett Forest Research Station after 9.5 years of warming. The study site has a Mediterranean climate with annual average temperature of 12.5 ℃ and annual average precipitation of 1774 mm. The study site is characterized by a mesic Ultic Alfisol formed from granitic parent material, corresponding to a Dystric Cambisol under the World Reference Base for Soil Resources (WRB) classification system. Experimental warming is applied throughout the soil profile to a depth of 1 m using vertically embedded heating cables that raise soil temperature by 4 °C relative to ambient conditions. Soil samples were collected on 1 May 2023, after the experiment had been operating continuously for about 9.5 years since its initiation in January 2014.The data has been processed from raw data and cross-validated by other peers. The dataset includes: - Bulk_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including Carbon Preference Index (CPI) and Average Chain Length (ACL) of bulk soil organic carbon; - Fractions_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including CPI and ACL of free particulate organic matter (fPOM) and mineral-associated organic matter (MAOM); - Bulk_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of bulk soil organic carbon; - Fractions_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of fPOM and MAOM; - n-Alkanes_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the n-alkane monomers identified and integrated for bulk soil, fPOM and MAOM; - Fattyacid_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the fatty acid monomers including diacids identified and integrated for bulk soil, fPOM, and MAOM. All data are provided in CSV format and can be viewed using Microsoft Excel. We specifically look at fatty acids (FA) and n-alkanes in bulk soil, fPOM and MAOM and calculated molecular proxies such as CPI and ACL to understand the source of oragnic carbon (with ACL) and degree of decomposition (CPI) of each soil fraction. Due to lack of long-chain fatty acids (carbon number ⩾ 20), microorganism-derived organic carbon is characterized by shorter ACL in comparison to plant-derived organic carbon. Fresh SOC is characterized by even-over-odd dominance for fatty acids and odd-over-even dominance for n-alkanes. Therefore, CPI indicates whether soil organic carbon (SOC) represents fresh input (CPI > 10) or is strongly decomposed (close to 1). The research questions should be then, after 9.5-year warming: 1. whether the relative contribution between microorganism-derived and plant-derived SOC in each soil fraction? 2. whether fPOM became more decomposed whereas MAOM remained relatively persistent in each soil fraction across the soil depth?

Carbon↗

Comprehensive Plasma Instrumentation (CPU) for the Geotail spacecraft

Geotail was launched on 24 July 1992 as the first new spacecraft of the International Solar Terrestrial Physics Program (ISTP). A primary objective of the Geotail mission is the acquisition of particles and fields measurements in the tail region of the magnetosphere. Some of the specific scientific objectives of the Geotail mission are; (1) assessment of the relative importance of solar-wind and ionospheric sources to the plasmas of the magnetotail, (2) a search for plasmoids and flux ropes, (3) direct observation of the effects of plasma acceleration and heating in the current sheet, and (4) measurements of currents and convective flows carried by magnetotail plasmas. The Comprehensive Plasma Instrumentation (CPI) aboard the Geotail spacecraft provides observations of the charged particles that comprise the plasma populations of the magnetosphere and the solar wind. In many cases the physical processes that contribute to the flow of energy and mass through the Solar-Terrestrial plasma system can be understood only through a detailed examination and analysis of the distribution of the particle velocities in the ambient plasmas. The CPI provides detailed measurements of these distributions. It employs three plasma analyzers: (1) the Hot Plasma analyzer (CPI-HP) for hot electrons and ions found in the plasma sheet and the inner magnetosphere; (2) a Solar Wind analyzer (CPI-SW) for cool plasmas with high bulk speeds such as those found in the solar wind and magnetosheath; and (3) an Ion Composition analyzer (CPI-IC) for identification of ion species such as H(+), He(+), He(++), and O(+). Along with measurements from other fields and particles instrumentation on Geotail, the CPI measurements provide a fundamental experimental base for investigations of solar-terrestrial plasmas and fields.

Frank, Louis A.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

On the use of charged particles to characterize precipitation in irradiated reactor pressure vessel steels with a wide range of compositions

Nuclear reactor lifetimes may be limited by nano-scale Cu-Mn-Ni-Si precipitates (CRPs and MNSPs) that form under neutron irradiation (NI) of pressure vessel (RPV) steels, resulting in hardening and ductile to brittle transition temperature increases (embrittlement). Physical models of embrittlement must be based on characterization of precipitation as a function of the combination of metallurgical and irradiation variables. Here we focus on rapid and convenient charged particle irradiations (CPI) to both: a) compare to precipitates formed in NI; and, b) use CPI to efficiently explore precipitation in steels with a very wide range of compositions. Atom probe tomography (APT) comparisons show NI and CPI for similar bulk steel solute contents yield nearly the same precipitate compositions, albeit with some differences in their number density, size and volume fraction (f) dose (dpa) dependence. Yet, the overall precipitate evolutions are very similar. Advanced high Ni (>3 wt%) RPV steels, with superior unirradiated properties, were also investigated at high CPI dpa. For typical Mn contents, MNSPs have Ni 16 Mn 6 Si 7 or Ni 3 Mn 2 Si phase type compositions, with f values that are close to the equilibrium phase separated values. In contrast, in steels with very low Mn and high Ni, Ni 2-3 Si silicide phase type precipitate compositions are observed; and when Ni is low, the precipitate compositions are close to the MnSi phase field. Low Mn significantly reduces, but does not eliminate, precipitation in high Ni steels. A comparison of dispersed barrier model predictions with measured hardening data suggests that the Ni-Si dominated precipitates are weaker dislocation obstacles than the G phase type MNSPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Techno-economic Analysis and Life Cycle Assessment of Producing High-Value Chemicals and Fuels from Waste Plastic via Conventional Pyrolysis and Thermal Oxo-degradation

The rapid rise in global plastic production in recent decades has resulted in the massive generation of plastic waste. Over 75% of the plastic waste generated in the United States was sent to landfills, with a meager 8.7% recycled. Plastics are valuable feedstocks for platform chemicals and fuels. Chemical upcycling of waste high-density polyethylene (HDPE) is gaining more attention as a potentially feasible and environmentally friendly plastic waste management technology. Conventional pyrolysis (CPY) and thermal oxo-degradation (TOD) are two chemical upcycling technologies actively researched for decomposing waste HDPE into valuable chemicals and fuels. However, there are few studies on the techno-economic analysis (TEA) and life cycle assessment (LCA) of these technologies for converting waste HDPE to valuable products. This study conducts a comparative TEA and LCA study of the thermochemical decomposition of waste HDPE to produce gaseous (ethylene and propylene) and liquid (naphtha, diesel, and wax) products by CPY and TOD. The study elucidates and compares the impact of hydrocracking longer chain hydrocarbons to produce more valuable products on the TEA and LCA. The TEA showed that the fixed capital investment could range from $\$32.5$ million for TOD without hydrocracking to $\$244$ million for CPY with hydrocracking scenarios. Annual revenues range from $\$28.1$ million to $\$71.5$ million in favor of scenarios with hydrocracking. However, the net present value ranges from $\$1.4$ million to $\$265.8$ million in favor of scenarios without hydrocracking. Sensitivity analysis showed that fixed capital cost, facility capacity, and product prices have the biggest impact on the process economics of the facilities, while utilities and waste transportation to refineries have the biggest impact on environmental impacts. Here, the LCA showed that primary products from scenarios without hydrocracking can be more environmentally friendly than virgin products from petroleum processes. However, TOD and CPY with hydrocracking primary products have more emissions than those of virgin products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

High Efficiency, Low Cost RF Sources for Accelerators and Colliders

Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency, low cost RF sources. Phase and Amplitude Controlled Magnetrons: CCR, Fermilab, and Communications & Power Industries, LLC (CPI) recently developed a 100 kW, 1.3 GHz magnetron system with amplitude and phase control. The system operated at more than 80% efficiency and demonstrated rapid control of amplitude and phase. Multiple Beam Triodes: CCR, in collaboration with CPI and JP Accelerator Works, Inc., is developing 200 kW, pulsed and CW RF sources from 350 to 700 MHz with projected efficiencies exceeding 80% and cost of $0.50/Watt. Prototype tubes are scheduled for tests in spring 2021. High Efficiency Klystrons:CCR, CPI, and Leidos, Inc. are building a 1.3 GHz, 100 kW klystron operating at 80% efficiency. High power testing is scheduled for summer 2021. Multiple Beam IOTs: CCR and Georgia Tech Research Institute are developing MBIOTs with simplified input coupling and high efficiency. Simulations indicate that 3rd harmonic drive power can increase the efficiency 8-10 %. The program is developing a prototype tube to produce 200 kW peak, 100 kW average power at 704 MHz.

43 PARTICLE ACCELERATORS↗

Organic matter in eolian dusts over the Atlantic Ocean

The elemental and mineralogical composition and the microfossil and detritus content of particulate fallout from the lower troposphere over the Atlantic Ocean have been extensively documented in earlier work, and it was possible to ascribe terrigenous source areas to such fallout. A brief review of the organic geochemistry of eolian dusts is also presented here. The lipids of eolian dusts sampled from the air mass over the eastern Atlantic from about 35 deg N to 30 deg S were analyzed here. These lipids consisted mainly of normal alkanes, carboxylic acids and alcohols. The n-alkanes were found to range from n-C23 to n-C35 with high CPI values and maximizing at n-C27 in the North Atlantic, at n-C29 in the equatorial Atlantic and at n-C31 in the South Atlantic. The n-fatty acids had mostly bimodal distributions, ranging from n-C12 to n-C30 (high CPI), with maxima at n-C16 and in the northern samples at n-C24 and in the southern samples at n-C26. The n-alcohols ranged from n-C12 to n-C32, with high CPI values and maxima mainly at n-C28. The compositions of these lipids indicated that their terrigenous sources were comprised mainly of higher plant vegetation and desiccated lacustrine mud flats on the African continent.

Simoneit, B. R. T.↗

A generic interface between COSMIC/NASTRAN and PATRAN (R)

Despite its powerful analytical capabilities, COSMIC/NASTRAN lacks adequate post-processing adroitness. PATRAN, on the other hand is widely accepted for its graphical capabilities. A nonproprietary, public domain code mnemonically titled CPI (for COSMIC/NASTRAN-PATRAN Interface) is designed to manipulate a large number of files rapidly and efficiently between the two parent codes. In addition to PATRAN's results file preparation, CPI also prepares PATRAN's P/PLOT data files for xy plotting. The user is prompted for necessary information during an interactive session. Current implementation supports NASTRAN's displacement approach including the following rigid formats: (1) static analysis, (2) normal modal analysis, (3) direct transient response, and (4) modal transient response. A wide variety of data blocks are also supported. Error trapping is given special consideration. A sample session with CPI illustrates its simplicity and ease of use.

Roschke, Paul N.↗

Novel Diffusivity Measurement Technique

A common-path interferometer (CPI) system was developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. This system uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. Hence, the molecular diffusion coefficient of liquids can be determined using the physical relations between changes in the optical path length and the liquid phase properties. The data obtained with this interferometer were compared with similar results from other techniques and demonstrated that the instrument is superior in measuring the diffusivity of miscible liquids while keeping the system very compact and robust. CPI can also be used for studies in interface dynamics and other diffusion-dominated-process applications.

Rashidnia, Nasser↗