Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Further characterization of Closed Pore Insulation (CPI)

The thermophysical and mechanical properties of closed pore insulation (CPI) were measured after exposure to 25 simulated reentry thermal cycles. In addition, mechanical properties were obtained at elevated temperatures before and after cycling. The properties of CPI were not compromised by the cycling. High temperature creep studies were done on three CPI compositions (4, 8, and 12 Wt% CoO additive). CPI-4 had the best creep resistance at temperatures up to 1363 K.

Russak, M.↗

LARC-CPI, a new semi-crystalline polyimide

As part of a program on high performance/high temperature structural resins for aerospace applications, work was performed with a new semi-crystalline polyimide (LARC-CPI) to improve the compression moldability while retaining high mechanical properties and thermooxidative stability. Various molecular weight versions of LARC-CPI polyamide acid were prepared, end-capped with different groups, converted to polyimide and evaluated for film properties, thermooxidative stability and melt flow. One controlled molecular weight, end-capped version of LARC-CPI was evaluated more comprehensively in adhesive and composite work and exhibited good compression moldability, reasonable crystallization rates and high mechanical properties.

Hergenrother, P. M.↗

Adhesive properties of LARC-CPI, a new semi-crystalline polyimide

As part of an effort on high temperature structural resins for aerospace applications, a new family of polyimides containing carbon and ether connecting groups between aromatic rings were prepared. Several of these polyimides were semicrystalline. One polyimide, designated LARC-CPI, with a glass transition temperature of 222 C and a crystalline melt temperature of 350 C, was evaluated in the form of an adhesive, film, and molding. Unoriented films exhibited excellent resistance to solvents and strong bases and high tensile properties. Compact tension specimens gave very high fracture toughness values. Titanium tensile shear specimens provided exceptional strength under a variety of test conditions. The chemistry and the physical and mechanical properties of LARC-CPI are discussed.

Hergenrother, P. M.↗

Chemistry and properties of controlled molecular weight end-capped LaRC-CPI

As part of a program on structural resins for high temperature aerospace applications, a controlled molecular weight end-capped semi-crystalline polyimide, designated LaRC-CPI, was evaluated. Neat resin moldings, adhesive specimens and composites were fabricated at temperatures of 365-375 C under pressures of 200-500 psi. Adhesive and composite specimens provided good mechanical properties at temperatures as high as 232 C.

Hergenrother, Paul M.↗

Development and Characterization of CPI Surface Insulation

A new type of reusable surface material that could find application as a component of the thermal protection system of the space shuttle orbiter is discussed. These materials consist of 20-30% dense closed cell high emittance glass ceramic foams formulated by sintering an intimate mixture of fly ash cenospheres with 4-12 wt % cobalt oxide. These unique ceramic foams exhibit: (1) High mechanical strengths; (2) no need for waterproof coating due to the non-interconnecting cell network; (3) high emissivities; (4) ability to withstand space shuttle thermal environments with no loss of reuse capability; and (5) a machinable ceramic with capability of maintaining the close tolerances required of an integrated heat shield system.

Tobin, A.↗

Comprehensive Plasma Instrumentation (CPU) for the Geotail spacecraft

Geotail was launched on 24 July 1992 as the first new spacecraft of the International Solar Terrestrial Physics Program (ISTP). A primary objective of the Geotail mission is the acquisition of particles and fields measurements in the tail region of the magnetosphere. Some of the specific scientific objectives of the Geotail mission are; (1) assessment of the relative importance of solar-wind and ionospheric sources to the plasmas of the magnetotail, (2) a search for plasmoids and flux ropes, (3) direct observation of the effects of plasma acceleration and heating in the current sheet, and (4) measurements of currents and convective flows carried by magnetotail plasmas. The Comprehensive Plasma Instrumentation (CPI) aboard the Geotail spacecraft provides observations of the charged particles that comprise the plasma populations of the magnetosphere and the solar wind. In many cases the physical processes that contribute to the flow of energy and mass through the Solar-Terrestrial plasma system can be understood only through a detailed examination and analysis of the distribution of the particle velocities in the ambient plasmas. The CPI provides detailed measurements of these distributions. It employs three plasma analyzers: (1) the Hot Plasma analyzer (CPI-HP) for hot electrons and ions found in the plasma sheet and the inner magnetosphere; (2) a Solar Wind analyzer (CPI-SW) for cool plasmas with high bulk speeds such as those found in the solar wind and magnetosheath; and (3) an Ion Composition analyzer (CPI-IC) for identification of ion species such as H(+), He(+), He(++), and O(+). Along with measurements from other fields and particles instrumentation on Geotail, the CPI measurements provide a fundamental experimental base for investigations of solar-terrestrial plasmas and fields.

Frank, Louis A.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Organic matter in eolian dusts over the Atlantic Ocean

The elemental and mineralogical composition and the microfossil and detritus content of particulate fallout from the lower troposphere over the Atlantic Ocean have been extensively documented in earlier work, and it was possible to ascribe terrigenous source areas to such fallout. A brief review of the organic geochemistry of eolian dusts is also presented here. The lipids of eolian dusts sampled from the air mass over the eastern Atlantic from about 35 deg N to 30 deg S were analyzed here. These lipids consisted mainly of normal alkanes, carboxylic acids and alcohols. The n-alkanes were found to range from n-C23 to n-C35 with high CPI values and maximizing at n-C27 in the North Atlantic, at n-C29 in the equatorial Atlantic and at n-C31 in the South Atlantic. The n-fatty acids had mostly bimodal distributions, ranging from n-C12 to n-C30 (high CPI), with maxima at n-C16 and in the northern samples at n-C24 and in the southern samples at n-C26. The n-alcohols ranged from n-C12 to n-C32, with high CPI values and maxima mainly at n-C28. The compositions of these lipids indicated that their terrigenous sources were comprised mainly of higher plant vegetation and desiccated lacustrine mud flats on the African continent.

Simoneit, B. R. T.↗

A generic interface between COSMIC/NASTRAN and PATRAN (R)

Despite its powerful analytical capabilities, COSMIC/NASTRAN lacks adequate post-processing adroitness. PATRAN, on the other hand is widely accepted for its graphical capabilities. A nonproprietary, public domain code mnemonically titled CPI (for COSMIC/NASTRAN-PATRAN Interface) is designed to manipulate a large number of files rapidly and efficiently between the two parent codes. In addition to PATRAN's results file preparation, CPI also prepares PATRAN's P/PLOT data files for xy plotting. The user is prompted for necessary information during an interactive session. Current implementation supports NASTRAN's displacement approach including the following rigid formats: (1) static analysis, (2) normal modal analysis, (3) direct transient response, and (4) modal transient response. A wide variety of data blocks are also supported. Error trapping is given special consideration. A sample session with CPI illustrates its simplicity and ease of use.

Roschke, Paul N.↗

Novel Diffusivity Measurement Technique

A common-path interferometer (CPI) system was developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. This system uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. Hence, the molecular diffusion coefficient of liquids can be determined using the physical relations between changes in the optical path length and the liquid phase properties. The data obtained with this interferometer were compared with similar results from other techniques and demonstrated that the instrument is superior in measuring the diffusivity of miscible liquids while keeping the system very compact and robust. CPI can also be used for studies in interface dynamics and other diffusion-dominated-process applications.

Rashidnia, Nasser↗

Classification of Particle Shapes from Lidar Depolarization Ratios in Convective Ice Clouds Compared to in situ Observations During CRYSTAL-FACE

This manuscript describes a method to class@ cirrus cloud ice particle shape using lidar depolarization measurements as a basis for segregating different particle shape regimes. Measurements from the ER-2 Cloud Physics Lidar (CPL) system during CRYSTAL-FACE provide the basis for this work. While the CPL onboard the ER-2 aircraft was providing remote sensing measurements of cirrus clouds, the Cloud Particle Imager (CPI) onboard the WB-57 aircraft was flying inside those same clouds to sample particle sizes. The results of classifying particle shapes using the CPL data are compared to the in situ measurements made using the CPI , and there is found to be good agreement between the particle shape inferred from the CPL data and that actually measured by the CPI. If proven practical, application of this technique to spaceborne observations could lead to large-scale classification of cirrus cloud particle shapes.

Noel, Vincent↗

Long-chain carboxylic acids in pyrolysates of Green River kerogen

Long-chain fatty acids (C10-C32), as well as C14-C21 isoprenoid acids (except for C18), have been identified in anhydrous and hydrous pyrolyses products of Green River kerogen (200-400 degrees C, 2-1000 hr). These kerogen-released fatty acids are characterized by a strong even/odd predominance (CPI: 4.8-10.2) with a maximum at C16 followed by lesser amounts of C18 and C22 acids. This distribution is different from that of unbound and bound geolipids extracted from Green River shale. The unbound fatty acids show a weak even/odd predominance (CPI: 1.64) with a maximum at C14, and bound fatty acids display an even/odd predominance (CPI: 2.8) with maxima at C18 and C30. These results suggest that fatty acids were incorporated into kerogen during sedimentation and early diagenesis and were protected from microbial and chemical changes over geological periods of time. Total quantities of fatty acids produced during heating of the kerogen ranged from 0.71 to 3.2 mg/g kerogen. Highest concentrations were obtained when kerogen was heated with water for 100 hr at 300 degrees C. Generally, their amounts did not decrease under hydrous conditions with increase in temperature or heating time, suggesting that significant decarboxylation did not occur under the pyrolysis conditions used, although hydrocarbons were extensively generated.

Non-NASA Center↗

Measuring Diffusion of Liquids by Common-Path Interferometry

A method of observing the interdiffusion of a pair of miscible liquids is based on the use of a common-path interferometer (CPI) to measure the spatially varying gradient of the index refraction in the interfacial region in which the interdiffusion takes place. Assuming that the indices of refraction of the two liquids are different and that the gradient of the index of refraction of the liquid is proportional to the gradient in the relative concentrations of either liquid, the diffusivity of the pair of liquids can be calculated from the temporal variation of the spatial variation of the index of refraction. This method yields robust measurements and does not require precise knowledge of the indices of refraction of the pure liquids. Moreover, the CPI instrumentation is compact and is optomechanically robust by virtue of its common- path design. The two liquids are placed in a transparent rectangular parallelepiped test cell. Initially, the interface between the liquids is a horizontal plane, above which lies pure liquid 2 (the less-dense liquid) and below which lies pure liquid 1 (the denser liquid). The subsequent interdiffusion of the liquids gives rise to a gradient of concentration and a corresponding gradient of the index of refraction in a mixing layer. For the purpose of observing the interdiffusion, the test cell is placed in the test section of the CPI, in which a collimated, polarized beam of light from a low-power laser is projected horizontally through a region that contains the mixing layer.

Rashidnia, Nasser↗

Mission Operations and Command Assurance: Automating an Operations TQM Task

Mission Operations and Command Assurance (MO&CA) is a Total Quality Management (TQM) task on JPL projects to instill quality into mission operations. The mission operations environment is inherently risky because each decision made is potentially mission critical. The flight operations environment generally requires operators to make rapid critical decisions and solve problems based on limited information, while closely following standard procedures. MO&CA's primary goal is to help improve the operational reliability and reduce risk of projects during flight. To achieve this goal, automation of the MO&CA task is required. MO&CA specifically embodies the TQM principle of continuous process improvement (CPI) in which processes are continually examined and analyzed for opportunities for improvement. The second way in which MO&CA implements CPI on JPL projects is on new projects or upgrades to existing projects.

mission↗

Mission Operations and Command Assurance: Automating an Operations TQM Task

A long-term program is in progress at JPL to reduce cost and risk of mission operations through defect prevention and error management. A major element of this program, Mission Operations and Command Assurance (MO&QA), provides a system level function on flight projects to instill quality in mission operations. MO&CA embodies the Total Quality Management (TQM) principle of Continuous Process Inprovement (CPI) and uses CPI in applying automation to mission operations to reduce risk and costs. MO&CA has led efforts to apply and has implemented automation in areas that impact the daily flight project environment including Incident Surprise Anomoly tracking and reporting; command data verification, tracking, and reporting; and command support data usage. MO&CA's future work in automation will take into account that future missions systems must be designed to avoid increasing error through the introduction of automation, while adapting to the demands of smaller flight teams.

automation↗

Development of a closed pore insulation material

A closed pore ceramic foam insulation material (CPI) has been developed that offers possibilities for use as a reusable external heat shield for the NASA manned space shuttle. The outstanding characteristics of CPI are: (1) negligible water absorption due to a noninterconnecting network of cells; (2) high emittance at room and elevated temperature; (3) ability to survive at least 10 simulated reentry cycles to 1500 K using radiant heat lamps to simulate the reentry heat fluxes; (4) ability to survive, with no change in properties or appearance, at least 10 simulated plasma arc jet cycles to 1500 K (with the exception of some stress cracks induced either by the unduly severe nature of the initial arc splash heating pulse or by improper mechanical holding of the specimen in the test fixture); (5) strength (flexure); and (6) a low thermal conductivity throughout the temperature range of interest for the space shuttle.

Tobin, A.↗