Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler↗

CPL Materials Life Cycle Test Facility

The Capillary Pumped Loop (CPL) Materials Life Cycle Test Facility at the Goddard Space Flight Center (GSFC) will identify the operational parameters controlling the performance of a CPL over an extended period of time. The primary purpose of the facility is to investigate the long-term chemical compatibility between the anhydrous ammonia working fluid and the CPL materials of construction. Chemical reactions occurring within the system may produce non-condensable gases or particulate debris that can lead to a degradation in system performance. Small liquid samples will be drawn from the system at specific time intervals and analyzed to check for the presence of non-condensable gases. Periodic maximum and minimum heat load tests will be performed on the CPL to monitor trends in the overall system performance.

Buchko, Matthew T.↗

CPL Applications on the EOS-TERRA Spacecraft

This presentation reviews the use of Capillary Pumped Loops on the EOS-TERRA spacecraft, It starts with a brief review of the status of CPL technology. On the TERRA spacecraft, CPL's will be used for thermal control of 3 instruments. The document reviews the ground testing, and states that life testing will continue to run for three year, even after the launch.The document has schematic diagrams of the EOS-AM spacecraft, the Advanced Spaceborne Thermal Emission and Reflection Radiometer - Thermal-Infrared Radiometer (ASTER-TIR) CPL configuration, the Advanced Spaceborne Thermal Emission and Reflection Radiometer - Short-Wave-Infrared Radiometer (ASTER-SWIR). The use of Measurements of Pollution In The Troposphere (MOPITTS) Capillary Pumped Heat Transport System (CPHTS) is reviewed, and the performance is summarized in several charts. The use of CPHTS in the ASTER-SWIR is reviewed. The loops in the ASTER-TIR module is also reviewed, and the problems with the second loop temperature control is discussed.

Ku, Jentung↗

Capillary Pump Loop (CPL) heat pipe development status report

The capillary pump loop (CPL) was re-introduced as a potential candidate for the management of large heat loads. It is currently being evaluated for application in the thermal management of large space structures. Test efforts were conducted to establish the feasibility of the CPL heat pipe design.

Source record↗

Overview of CPL and LHP Applications on NASA MIssions

Capillary Pumped Loops (CPL's) and Loop Heat Pipes (LHP's) are finding increased acceptance on upcoming NASA spacecraft missions, as well as military and commercial applications, The transition from a research and development tool to an "off the shelf' system is underway. The state of the art of two phase systems (TPS) is reviewed and applications on various NASA missions are discussed, with particular emphasis on new technology developments. Upcoming research areas and flight experiments are also addressed, along with recommendations for future activities.

Butler, C. Dan↗

Overview of CPL and LHP Applications on NASA Missions

Capillary Pumped Loops (CPL's) and Loop Heat Pipes (LHP's) are finding increased acceptance on upcoming NASA spacecraft missions, as well as military and commercial applications. The transition from a research and development tool to an "off the shelf' system is underway. The state of the art of two phase systems (TPS) is reviewed and applications on various NASA missions are discussed, with particular emphasis on new technology developments. Upcoming research areas and flight experiments are also addressed, along with recommendations for future activities.

Butler, Dan↗

Overview of CPL and LHP Applications on NASA Missions

Capillary Pumped Loops (CPL's) and Loop Heat Pipes (LHP's) are finding increased acceptance on upcoming NASA spacecraft missions, as well as military and commercial applications. The transition from a research and development tool to an "off the shelf' system is underway. The state of the art of Two Phase Systems (TPS) is reviewed and applications on various NASA missions are discussed, with particular emphasis on new technology developments.

Butler, Dan↗

SINFAC simulation of a high-power hybrid CPL

The systems improved numerical fluids analysis code (SINFAC) was used to model a high-power hybrid capillary-pumped loop. A comparison was made between the simulation results and actual experimental test data for the mechanical-pump-assist mode of operation. The hybrid capillary-pumped loop consisted of a capillary-pumped loop with a mechanical pump in the liquid return line with a bypass value so that the system could be operated either as a capillary-only loop or a series hybrid loop. Excellent agreement was obtained between numerical and experimental data.

Benner, Steve M.↗

Investigation of thermal-fluid mechanical characteristics of the Capillary Pump Loop

The main purpose is the experimental and analytical study of behavior of the Capillary Pump Loop (CPL) heat pipe system during the transient mode of operating by applying a step heat pulse to one or more evaporators. Prediction of the CPL behavior when subjected to pulse heat loading requires further study before the transient response of CPL system can be fully understood. The following tasks are discussed: (1) exploratory testing of a CPL heat pipe for transient operational conditions which could generate the type of oscillatory inlet temperature behavior observed in an earlier testing of NASA/GSFC CPL-2 heat pipe system; (2) analytical investigation of the CPL inlet section temperature oscillations; (3) design, construction and testing of a bench-top CPL test system for study of the CPL transient operation; and (4) transient analysis of a CPL heat pipe by applying a step power input to the evaporators.

Kiper, Ali M.↗

Cloud Physics Lidar Measurements During the SAFARI-2000 Field Campaign

A new remote sensing instrument, the Cloud Physics Lidar (CPL) has been built for use on the ER-2 aircraft. The first deployment for CPL was the SAFARI-2000 field campaign during August-September 2000. The CPL is a three-wavelength lidar designed for studies of cirrus, subvisual cirrus, and boundary layer aerosols. The CPL utilizes a high repetition rate, low pulse energy laser with photon counting detectors. A brief description of the CPL instrument will be given, followed by examples of CPL data products. In particular, examples of aerosol backscatter, including boundary layer smoke and cirrus clouds will be shown. Resulting optical depth estimates derived from the aerosol measurements will be shown. Comparisons of the CPL optical depth and optical depth derived from microPulse Lidar and the AATS-14 sunphotomer will be shown.

McGill, Matthew↗

Surface-Treated Composite Polymer as a Stable Artificial Solid Electrolyte Interphase Layer for Lithium Metal Anodes

Lithium (Li) metal batteries (LMBs) are one of the most promising high energy density batteries to meet the demands of electric transportation. However, the practical applications of LMBs are hindered by short cycle life and safety concern, mainly associated with side reactions between Li metal anode and liquid electrolyte and the growth of Li dendrites during cycling. In this study, we develop a stable artificial solid electrolyte interphase (aSEI), which consists of a surface-treated (S T ) PEO–Li 6.4 Ga 0.2 La 3 Zr 2 O 12 composite polymer coating layer (CPL) on Li metal anode. The developed aSEI is stable against selected electrolyte and enables a uniform electrodeposition of Li. Therefore, S T CPL@Li||LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cells exhibit improved cycling stability compared with bare Li||NMC811 cells at moderate to high current densities. Notably, using a 50 µm thick Li and a practical NMC811 cathode (~4.8 mAh cm -2 ), a capacity retention of 85% is obtained for S T CPL@Li||NMC811 cells at a current density of 2.4 mAcm -2 after 300 cycles compared with 24% for bare Li||NMC811 cells. Furthermore, S T CPL@Li||NMC811 cells demonstrate higher capacities at charge current densities of 2.4, 4.8 and 7.2 mAcm -2 compared with bare Li||NMC811 cells. Further, these findings suggest that S T CPL is promising for high current density practical LMBs.

25 ENERGY STORAGE↗

Self-Powered Circularly Polarized Light Detection Enabled by Chiral Two-Dimensional Perovskites with Mixed Chiral–Achiral Organic Cations

Direct detection of circularly polarized light (CPL) holds great promise for the development of various optical technologies. Chiral 2D organic–inorganic halide perovskites make it possible to fabricate CPL-sensitive photodetectors. However, selectively detecting left-handed circularly polarized (LCP) and right-handed circularly polarized (RCP) light remains a significant challenge. Herein, we demonstrate a greatly enhanced distinguishability of photodiode-type CPL photodetectors based on chiral 2D perovskites with mixed chiral aryl (R)-(+),(S)-(–)-α-methylbenzylammonium (R,S-MBA) and achiral alkyl n-butylammonium (nBA) cations. The (R,S-MBA 0.5 nBA 0.5 ) 2 PbI 4 perovskites exhibit a 10-fold increase in circular dichroism signals compared to (R,S-MBA) 2 PbI 4 perovskites. Here, the CPL photodetectors based on the mixed-cation perovskites exhibit self-powered capabilities with a specific detectivity of 2.45 × 10 12 Jones at a o V bias. Notably, these devices show high distinguishability (gres) factors of –0.58 and +0.54 based on (R,S-MBA 0.5 nBA 0.5 ) 2 PbI 4 perovskites, respectively, surpassing the performance of (R-MBA) 2 PbI 4 -based devices by over 3-fold and setting a record for CPL detectors based on chiral 2D n = 1 perovskites.

36 MATERIALS SCIENCE↗

Enantioselective Se lattices for stable chiroptoelectronic processing media

Chiroptoelectronic devices are crucial for applications in quantum computing, spin optical communications, and magnetic recording. However, the limited efficiency and low stability of conventional circularly polarized light (CPL)-sensing materials have restricted their broader use. Here, we introduce atomic chiral Se nanorod (NRs) films as broadband CPL detectors, leveraging the intrinsic chirality and stability of Se nanocrystals. We also perform incident circular polarization (ICP)-Raman optical activity (ROA) to explore the chiroptical activity of the large-area films. The Se NRs thin films detected CPL across a broad range from ultraviolet (UV) to short-wavelength infrared (SWIR), with a responsivity dissymmetry factor of up to 0.4, maintaining high stability under ambient conditions for longer than 13 months. CPL-sensitive Se NRs with intrinsic chirality have potential applications in chiral photonic synapses, chiral spin devices, and CPL-sensitive photocatalysts. ICP-ROA mapping also advances the analysis of 2D chiral materials.

Nanophotonics and plasmonics↗

Verification of an analytic modeler for capillary pump loop thermal control systems

A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.

Schweickart, R. B.↗

Capillary Pumped Heat Transfer (CHT) Experiment

The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

Hallinan, Kevin P.↗

Comments on the Operation of Capillary Pumped Loop Devices in Low Gravity

The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

Hallinan, K. P.↗

The Cloud Physics Lidar: Instrument Description and Initial Measurement Results

The new Cloud Physics Lidar (CPL) has been built for use on the NASA ER-2 high altitude aircraft. The purpose of the CPL is to provide multi-wavelength measurements of cirrus, subvisual cirrus, and aerosols with high temporal and spatial resolution. The CPL utilizes state-of-the-art technology with a high repetition rate, a low pulse energy laser, and photon-counting detection. The first deployment for the CPL was the SAFARI-2000 field campaign during August-September 2000. We provide here an overview of the instrument and initial data results to illustrate the measurement capability of the CPL.

McGill, Matthew↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗