Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Comparison of CCM- and CRM-Based Boost Parallel Active Power Decoupler for PV Microinverter

Single-phase inverter or rectifier systems often make use of an active power decoupler (APD) to balance the mismatch between constant dc power and fluctuating ac power. This article deals with the comparison of continuous conduction mode (CCM) and critical conduction mode (CRM) operation-based design of a parallel boost-type APD for photovoltaic microinverter applications. From a design perspective, multiobjective analysis of efficiency, volume, and cost is explored within a decision space including planar inductors, gallium nitride based devices, film capacitors, switching frequency, and modulation (CCM vs. CRM). The theoretical study analyzes all possible design configurations within CCM and CRM and identifies Pareto-optimal designs, from which the selected CRM design can achieve reduced system volume and lower cost with the use of smaller inductor core, while operating with similar California Energy Commission efficiency drop as the selected CCM design. From a control perspective, a pulsewidth modulation based control strategy is proposed to implement closed-loop CRM modulation that does not rely on zero-crossing detection. Furthermore, closed-loop systems are designed for the optimal CCM and CRM realizations, and the final system characteristics are compared. Experimental results, obtained using two separate 40-V, 400-W hardware prototypes for CCM and CRM, are presented to verify the analyses.

42 ENGINEERING↗

Monomeric crystal structure of the vaccine carrier protein CRM 197 and implications for vaccine development

CRM 197 is a genetically detoxified mutant of diphtheria toxin (DT) that is widely used as a carrier protein in conjugate vaccines. Protective immune responses to several bacterial diseases are obtained by coupling CRM 197 to glycans from these pathogens. Wild-type DT has been described in two oligomeric forms: a monomer and a domain-swapped dimer. Their proportions depend on the chemical conditions and especially the pH, with a large kinetic barrier to interconversion. A similar situation occurs in CRM 197 , where the monomer is preferred for vaccine synthesis. Despite 30 years of research and the increasing application of CRM 197 in conjugate vaccines, until now all of its available crystal structures have been dimeric. Here, CRM 197 was expressed as a soluble, intracellular protein in an Escherichia coli strain engineered to have an oxidative cytoplasm. The purified product, called EcoCRM, remained monomeric throughout crystallization. The structure of monomeric EcoCRM is reported at 2.0 Å resolution with the domain-swapping hinge loop (residues 379–387) in an extended, exposed conformation, similar to monomeric wild-type DT. The structure enables comparisons across expression systems and across oligomeric states, with implications for monomer–dimer interconversion and for the optimization of conjugation.

60 APPLIED LIFE SCIENCES↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

NBL Pu CRM (Phase 1 Progress Report)

Several 100 μg aliquots of NBL CRM 137 Pu sulfate tetrahydrate were prepared in 20 mL glass vials at some time in the past and are expected to have similar chemical composition and similar concentrations of contaminants as the bulk 250 mg CRM 137 Pu sulfate tetrahydrate units. Thus, these units were characterized and used to test Pu purification chemistry to be employed on the larger unit. For preliminary characterization, the residue of bottle 6 was dissolved in 4 M HNO3/0.01 M HF and transferred quantitatively to a pre-weighed 30 mL Savillex Teflon vial with a total solution mass of approximately 18 g. A gravimetric aliquot was removed from this solution for characterization and the remaining solution was dried down and reconstituted in 8 M HNO 3 to test the anion exchange purification column.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O↗

Compensatory reserve detects subclinical shock with more expeditious prediction for need of life‐saving interventions compared to systolic blood pressure and blood lactate

Abstract Introduction We conducted a prospective observational study on 205 trauma patients at a level I trauma facility to test the hypothesis that a compensatory reserve measurement (CRM) would identify higher risk for progression to shock and/or need a life‐saving interventions (LSIs) earlier than systolic blood pressure (SBP) and blood lactate (LAC). Methods A composite outcome metric included blood transfusion, procedural LSI, and mortality. Discrete measures assessed as abnormal (ab) were SBP <90 mmHg, CRM <60%, and LAC >2.0. A graded categorization of shock was defined as: no shock (normal [n] SBP [n‐SBP], n‐CRM, n‐LAC); sub‐clinical shock (ab‐CRM, n‐SBP, n‐LAC); occult shock (n‐SBP, ab‐CRM, ab‐LAC); or overt shock (ab‐SBP, ab‐CRM, ab‐LAC). Results Three patients displayed overt shock, 53 displayed sub‐clinical shock, and 149 displayed no shock. After incorporating lactate into the analysis, 86 patients demonstrated no shock, 25 were classified as sub‐clinical shock, 91 were classified as occult shock, and 3 were characterized as overt shock. Each shock subcategory revealed a graded increase requiring LSI and transfusion. Initial CRM was associated with progression to shock (odds ratio = 0.97; p < .001) at an earlier time than SBP or LAC. Conclusions Initial CRM uncovers a clinically relevant subset of patients who are not detected by SBP and LAC. Our results suggest CRM could be used to more expeditiously identify injured patients likely to deteriorate to shock, with requirements for blood transfusion or procedural LSI.

Convertino, Victor A.↗

Representation of atmosphere-induced heterogeneity in land–atmosphere interactions in E3SM–MMFv2

In the Energy Exascale Earth System Model (E3SM) Multi-scale Modeling Framework (MMF), where parameterizations of convection and turbulence are replaced by a 2-D cloud-resolving model (CRM), there are multiple options to represent land–atmosphere interactions. Here, we propose three different coupling strategies, namely the (1) coupling of a single land surface model to the global grid (MMF), (2) coupling a single land copy directly to the embedded CRM (SFLX2CRM), and (3) coupling a single copy of land model to each column of the CRM grid (MAML). In the MAML (Multi-Atmosphere Multi-Land) framework, a land model is coupled to CRM at the CRM-grid scale by coupling an individual copy of a land model to each CRM grid. Therefore, we can represent intra-CRM heterogeneity in the land–atmosphere interaction processes. There are 5-year global simulations run using these three coupling strategies, and we find some regional differences but overall small changes with respect to whether a land model is coupled to CRM or a global atmosphere. In MAML, the spatial heterogeneity within CRM induces stronger turbulence, which leads to the changes in soil moisture, surface heat fluxes, and precipitation. However, the differences in the MAML from the other two cases are rather weak, suggesting that the impact of using MAML does not justify the increase in cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Effects of non-equilibrium ionization and excitation on radiation absorption in plasma plumes induced by ablation of metal targets with nanosecond laser pulses

Ionization and radiation absorption in nanosecond laser-induced plasma plumes are routinely modeled using the Saha–Boltzmann equilibrium ionization model (EQM). However, the equilibrium assumption can be inaccurate during the laser pulse when non-equilibrium effects significantly impact radiation absorption. In the present work, the EQM and non-equilibrium collisional-radiative model (CRM) are compared to reveal the effect of plasma non-equilibrium on radiation absorption in non-homogeneous plumes and degree of plasma shielding. Simulations of plume expansion induced by irradiation of a copper target in 1 atm argon background gas with a 10 ns Gaussian pulse at a fluence from 8 Jcm −2 to 14 Jcm −2 are performed with a hybrid computational model that couples a lumped particle direct simulation Monte Carlo method with either CRM or EQM. The simulations show that the EQM strongly underestimates the effects of ionization and radiation absorption compared to CRM and, contrary to the CRM, predict strong ionization of the background gas. The differences between the models are explained by the qualitatively different coupling between plume expansion and dynamics of ionization and exitation processes in the CRM and EQM under conditions when the characteristic times for most radiation- and electron-induced processes are longer than the pulse duration. The CRM-based predictions are also found to agree much better with available experimental data. In conclusion, these results indicate that the model of Saha–Boltzmann equilibrium cannot be used for reliable prediction of the degree of plasma shielding in plumes induced by nanosecond laser pulses or for processing results of spectroscopic measurements at early stages of expansion of such plumes.

Physics - Plasma physics↗

Investigating Mechanisms Driving Differences in the Characteristics of Precipitation in the E3SM Multiscale Modeling Framework With 2D Versus 3D Cloud Resolving Model Configurations

Abstract In this study, we compare the Energy Exascale Earth Systems Model (E3SM) multiscale modeling framework (MMF) with the cloud resolving model (CRM) configured in two (2dMMF) and three (3dMMF) dimensions. We explore how CRM dimensionality impacts the representation of mean and extreme precipitation characteristics. Our results show that tropical mean precipitation patterns are better represented in 3dMMF compared to observations (Integrated Multi‐satellitE Retrivals for GPM and Global Precipitation Climatology Project One Degree Daily products), while 2dMMF better captures extreme precipitation intensity, with systematic land‐ocean differences in precipitation and cloud‐associated variables. These differences are attributed to the co‐occurrence of CRM throttling (i.e., suppressed convection in due to smaller numbers of CRM columns and domain size) and dilution (i.e., 3‐D cloud circulations with increased entrainment and lower precipitation efficiency) effects. Overall, throttling results in more low‐level humidity in 2dMMF and dilution contributes to more high clouds with less precipitation efficiency in 3dMMF. Since throttling occurs more strongly over the ocean than land, the 3dMMF tends to have less cloud liquid and precipitation over the ocean and more cloud ice and precipitation over land. These results may serve as a guide for choosing the CRM structure to reduce precipitation and cloud‐related biases.

54 ENVIRONMENTAL SCIENCES↗

Utility and Industry Perceptions of Control Room Modernization Over the Last 10 Years

Within the current United States (U.S.) nuclear power fleet, main control room modernization (CRM) is an important step towards cost savings. In recent decades, plants have been engaged in upgrades to varying degrees. This process requires a nuanced, balanced, and timely approach that ensures continued safety and long-term sustainability. In 2012 a survey was issued to individuals from the nuclear industry to learn their perspectives on a range of CRM issues. The survey targeted the benefits and challenges for utilities undertaking this process, including the main drivers and barriers to technology upgrades, regulatory compliance, and the effects these factors have on concepts of operations, strategic approaches, and staffing. In 2022, the survey was issued again to understand whether CRM perceptions had changed in the last 10 years. Our findings identify changes in industry thinking from a decade ago. Here we reveal perspective shifts that represent increased optimism and, in some instances, increased doubt regarding the opportunities and challenges inherent in CRM and implementation. We also report nuanced differences in CRM perspectives between utility and surrounding nuclear industry respondents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Explainable Machine-Learning Model for Compensatory Reserve Measurement: Methods for Feature Selection and the Effects of Subject Variability

Tracking vital signs accurately is critical for triaging a patient and ensuring timely therapeutic intervention. The patient’s status is often clouded by compensatory mechanisms that can mask injury severity. The compensatory reserve measurement (CRM) is a triaging tool derived from an arterial waveform that has been shown to allow for earlier detection of hemorrhagic shock. However, the deep-learning artificial neural networks developed for its estimation do not explain how specific arterial waveform elements lead to predicting CRM due to the large number of parameters needed to tune these models. Alternatively, we investigate how classical machine-learning models driven by specific features extracted from the arterial waveform can be used to estimate CRM. More than 50 features were extracted from human arterial blood pressure data sets collected during simulated hypovolemic shock resulting from exposure to progressive levels of lower body negative pressure. A bagged decision tree design using the ten most significant features was selected as optimal for CRM estimation. This resulted in an average root mean squared error in all test data of 0.171, similar to the error for a deep-learning CRM algorithm at 0.159. By separating the dataset into sub-groups based on the severity of simulated hypovolemic shock withstood, large subject variability was observed, and the key features identified for these sub-groups differed. This methodology could allow for the identification of unique features and machine-learning models to differentiate individuals with good compensatory mechanisms against hypovolemia from those that might be poor compensators, leading to improved triage of trauma patients and ultimately enhancing military and emergency medicine.

60 APPLIED LIFE SCIENCES↗