Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRYOGENIC TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flexible linkages for thermal management at cryogenic temperatures

Cryogenic system design often presents the competing requirements of thermal coupling between components while de-coupling them structurally. Good thermal coupling is necessary for adequate thermal management during cryogenic operation of the system and to reduce the cooldown time from the ambient to cryogenic temperature. Structural de-coupling is essential to reduce thermal stresses during cooldown, mitigate the trasmission of vibration and loads to sensitive and/or fragile components, and compensate for integration misalignments. Flexible thermal links (FTLs) are an essential component of cryogenic systems that provides a balance between thermal coupling and structural isolation.

42 ENGINEERING↗

VERY LOW FREQUENCY BREAKDOWN PROPERTIES OF ELECTRICAL INSULATION MATERIALS AT CRYOGENIC TEMPERATURES

For long cables or equipment with large capacitance it is not always possible to conduct high voltage withstand at tests at 60 Hz due to limitations in charging currents of the power supply. Very low frequency (typically at a frequency of 0.1 Hz) has been used for conventional cables as a way of getting around the charging current limitation. For superconducting grid applications the same issues apply. However there is very little data at cryogenic temperatures on how materials perform at low frequency compared to 60 Hz and whether higher voltages should be applied when performing a high voltage acceptability test. Various materials including G10 (fiberglass reinforced plastic or FRP), Cryoflex™ (a tape insulation used in some high temperature superconducting cables), kapton (commonly used polyimide), polycarbonate, and polyetherimide, and in liquid nitrogen alone have been tested using a step method for frequencies of 60 Hz, 0.1 Hz, and dc. The dwell time at each step was chosen so that the aging factor would be the same in both the 60 Hz and 0.1 Hz tests. The data indicated that, while there is a small frequency dependence for liquid nitrogen, there are significant differences for the solid materials studied. Breakdown data for these materials and for model cables will be shown and discussed.

cryogenic dielectric↗

The effects of ultra-fine-grained structure and cryogenic temperature on adiabatic shear localization in titanium

The deformation at low temperatures (173 K and 77 K) in ultrafine-grained (100 and 500 nm) titanium is investigated and its effect on adiabatic shear localization is established. In comparison with coarse grained titanium, the strength of ultrafine-grained titanium is higher due to the classic Hall-Petch effect while the strain hardening approaches zero. Our results show that shear localization in dynamic deformation is also altered. The width of the shear band of coarse-grained titanium decreases from 30 to 18 mm (by 40%) with decreasing the initial deformation temperature to 77 K. In contrast, for 100 nm titanium, the width of shear band decreases more significantly, from 4 mmat room temperature to 1 mm (a 75% decrease) at 77 K. This difference is attributed to the combined effects of the decrease in the thermal conductivity and specific heat capacity, and the increase in thermal softening rate. These changes in the width are consistent with the predictions of the Grady and Bai-Dodd theories. Ultrafine- and nanorecrystallized grains are observed inside the bands which are dependent on initial grain size and initial deformation temperature. Here, the dislocation evolution is evaluated for the different conditions using a Kocks-Mecking formulation; the rotational dynamic recrystallization mechanism responsible for forming the ultrafine/nanosized grains (40-250 nm) is successfully modeled incorporating the differences in initial temperature and grain size. Our results and analysis are important in enhancing the understanding of the structural evolution processes under high strain-rates and cryogenic temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Twinning-mediated work hardening and texture evolution in CrCoFeMnNi high entropy alloys at cryogenic temperature

The cryogenic plastic deformation of CrCoFeMnNi high entropy alloy is characterized by three distinct stages based on the change of the work hardening rate. Microstructure and bulk texture at different strain levels were studied by electron backscatter diffraction (EBSD) and neutron diffraction. Our findings indicate that the deformation twins led to the constant work hardening rate at Stage II and resulted in the appearance of <115 >//TA texture component, while the dislocation slip was involved all though the entire plastic deformation. As a result, the twinning-mediated tensile plastic deformation at cryogenic temperature finally induced the strong {111}- < 112 > texture component and minor {001} < 110 > texture component accompanied with twinning-induced {115}< 552 > texture component.

36 MATERIALS SCIENCE↗

Cryogenic temperature measurement

Cryogenic temperature measurement including metallic and semiconductor resistance thermometers, thermocouples and bibliography

Malone, J. H.↗

Effects of Coating and Diametric Load on Fiber Bragg Gratings as Cryogenic Temperature Sensors

Cryogenic temperature sensing was demonstrated using pressurized fiber Bragg gratings (PFBGs) with polymer coating of various thicknesses. The PFBG was obtained by applying a small diametric load to a regular fiber Bragg grating (FBG). The Bragg wavelengths of FBGs and PFBG were measured at temperatures from 295 K to 4.2 K. The temperature sensitivities of the FBGs were increased by the polymer coating. A physical model was developed to relate the Bragg wavelength shifts to the thermal expansion coefficients, Young's moduli, and thicknesses of the coating polymers. When a diametric load of no more than 15 N was applied to a FBG, a pressure-induced transition occurred at 200 K during the cooling cycle. The pressure induced transition yielded PFBG temperature sensitivities three times greater than conventional FBGs for temperatures ranging from 80 to 200 K, and ten times greater than conventional fibers for temperatures below 80 K. PFBGs were found to produce an increased Bragg wavelength shift of 2.2 nm compared to conventional FBGs over the temperature range of 4.2 to 300 K. This effect was independent of coating thickness and attributed to the change of the fiber thermo-optic coefficient.

Wu, meng-Chou↗

Effects of electrostatic discharge on three cryogenic temperature sensor models

Cryogenic temperature sensors are not usually thought of as electrostatic discharge (ESD) sensitive devices. However, the most common cryogenic thermometers in use today are thermally sensitive diodes or resistors - both electronic devices in their base form. As such, they are sensitive to ESD at some level above which either catastrophic or latent damage can occur. Instituting an ESD program for safe handling and installation of the sensor is costly and it is desirable to balance the risk of ESD damage against this cost. However, this risk cannot be evaluated without specific knowledge of the ESD vulnerability of the devices in question. This work examines three types of cryogenic temperature sensors for ESD sensitivity - silicon diodes, Cernox(trade mark, serif) resistors, and wire wound platinum resistors, all manufactured by Lake Shore Cryotronics, Inc. Testing was performed per TIA/EIA FOTP129 (Human Body Model). Damage was found to occur in the silicon diode sensors at discharge levels of 1,500 V. For Cernox(trade mark, serif) temperature sensors, damage was observed at 3,500 V. The platinum temperature sensors were not damaged by ESD exposure levels of 9,900 V. At the lower damage limit, both the silicon diode and the Cernox(trade mark, serif) temperature sensors showed relatively small calibration shifts of 1 to 3 K at room temperature. The diode sensors were stable with time and thermal cycling, but the long term stability of the Cernox(trade mark, serif) sensors was degraded. Catastrophic failure occurred at higher levels of ESD exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Dual-wavelength Fiber Bragg Gratings for Temperature and Strain Sensing at Cryogenic Temperature

By using dual-wavelength fiber-optic Bragg gratings, a new technique has been developed for sensing both temperature and strain simultaneously in cryogenic temperature range. Two Bragg gratings with different wavelengths were inscribed at the same location in an optical fiber to form a dual-wavelength sensor. By measuring the wavelength shifts that resulted from the fiber being subjected to different temperatures and strains, the wavelength-dependent thermo-optic coefficients and photoelastic coefficients of the fiber were determined. These coefficients were used to construct the elements of the K matrix, which enables to determine inversely the strain and temperature changes by measuring the wavelength shifts of the dual-wavelength Bragg grating. In this study, measurements were made over the temperature range from room temperature down to about 10 K, addressing much of the low temperature range of cryogenic tanks. A structure transition of the optical fiber during the temperature change was found from about 70 K to 140 K. This transition caused splitting of the waveforms characterizing the Bragg gratings, and the determination of wavelength shifts was consequently complicated. Several alternatives are proposed to resolve this problem. The effectiveness and sensitivities of these measurements in different temperature ranges are discussed. The separation of two wavelengths for the dual-wavelength Bragg grating has been widened to increase the sensitivities of measurement; however, this separation can still be covered in the scanning range from single scanning laser.

Wu, Meng-Chou↗