At least 19 records

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSCs Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses on its surface area to create a high vacuum environment of 5*10-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to validate thermal models. High temperature tests could benefit from reduced heater demand with an insulated shroud while still sustaining the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform thermal analyses to assess the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics

Computational Study of a Cryopump Design for Fusion Exhaust Gas Purification Using Direct Simulation Monte Carlo

Cryopump-based direct internal recycling (DIR) of fusion fuel is an attractive prospect because it provides pumping of helium ash from a reactor along with separation of helium and other impurities from the fuel. Previous studies have demonstrated a continuously regenerating cryopump, referred to as the Snail pump, that separates helium ash from fusion fuel for reactor-relevant flow rates. Here, in this study, a conceptual cryopump was designed as a proof-of-principle study to target other impurities, besides helium ash, from the fusion exhaust that would complement the Snail pump. The impurity-removal cryopump consists of four sets of chevron fins, two sets operating at 80 K and the other two at 30 K. A computational study using direct simulation Monte Carlo (DSMC) was performed with a gas mixture of 96.5% D2, 2.0% He, and 0.5% each of CO2, N2, and CH4. In this configuration, 80 K chevron fin sets are capable of capturing CO2 and 30 K sets capable of capturing CO2, N2, and CH4. The computational study showed that the cryopump is capable of reducing the impurity content by more than two orders of magnitude from the flow.

Adhikari, Nirajan [Oak Ridge National Laboratory (

Sticking Coefficients of Fusion Reactor Impurities from Molecular Dynamics Simulations for the Design of Cryopumps

A cryopump can be utilized as an impurity removal component of a direct internal recirculation (DIR) system for the fusion fuel cycle. The DIR facilitates a low fuel inventory by continuously pumping unburnt fuel while removing impurities from the fusion exhaust stream. A cryopump can target multiple impurity species by maintaining a temperature lower than the gas triple-point temperature that promotes desublimation. The desublimation/condensation of gases in cryopumps can be characterized by the sticking coefficient, which is defined as the probability for a gas particle to stick to a (cryo-)surface upon collision. The sticking coefficient is one of the important design/operation parameters for cryopumps, and it depends on a variety of surface and gas properties. Here, in this study, molecular dynamics simulations were utilized to estimate the sticking coefficients of typical fusion gas impurity species N 2 , CO 2 , and CH 4 over a Cu surface for a range of gas temperatures and surface coverages. The molecular dynamics study showed that the sticking coefficients for gases decrease with an increase in gas temperature. The presence of a single full monolayer of condensate on the metallic surface showed an adverse effect on the sticking of gases; however the sticking improved with two full monolayers of condensate on the surface. The sticking of gases over the mixed condensate on a surface was more favorable than the condensate of the same species for N 2 and CH 4 , with an exception for CO 2 , which showed a decrease in sticking over the mixed condensate.

cryopump

Methods for Cryopumping Xenon

Design Characteristics of a cryopump optimized for xenon are presented. The cost and complexity of installing and operating these cryopumps is a fraction of the cost and complexity to install and operate diffusions pumps or cryopumps that deliver similar pump speeds on xenon.

electric

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator

From diffusion pumps to cryopumps: The conversion of GSFC's space environment simulator

The SES (Space Environmental Simulator), largest of the Thermal Vacuum Facilities at The Goddard Space Flight Center, recently was converted from an oil diffusion pumped chamber to a Cryopumped chamber. This modification was driven by requirements of flight projects. The basic requirement was to retain or enhance the operational parameters of the chamber such as pumping speed, ultimate vacuum, pump down time, and thermal system performance. To accomplish this task, seventeen diffusion pumps were removed and replaced with eight 1.2 meter (48 inch) diameter cryopumps and one 0.5 meter (20 inch) turbomolecular pump. The conversion was accomplished with a combination of subcontracting and in-house efforts to maximize the efficiency of implementation.

Cary, Ron

Cryopumping in Cryogenic Insulations for a Reusable Launch Vehicle

Testing at cryogenic temperatures was performed to verify the material characteristics and manufacturing processes of reusable propellant tank cryogenic insulations for a Reusable Launch Vehicle (RLV). The unique test apparatus and test methods developed for the investigation of cryopumping in cryogenic insulations are described. Panel level test specimens with various types of cryogenic insulations were subjected to a specific thermal profile where the temperature varied from -262 C to 21 C. Cryopumping occurred if the interior temperature of the specimen exhibited abnormal temperature fluctuations, such as a sudden decrease in temperature during the heating phase.

Johnson, Theodore F.

Particle control via cryopumping and its impact on the edge plasma profiles of Alcator C-Mod

At the high n e proposed for high-field fusion reactors, it is uncertain whether ionization, as opposed to plasma transport, will be most influential in determining n e at the pedestal and separatrix. A database of Alcator C-Mod discharges is analyzed to evaluate the impact of source modification via cryopumping. The database contains similarly-shaped H-modes at fixed I P = 0.8 MA and B t = 5.4 T, spanning a large range in P net and ionization. Measurements from an edge Thomson scattering system are combined with those from a midplane-viewing Ly α camera to evaluate changes to n e and T e in response to changes in ionization rates, S ion ∙ $n^{sep}_e$ and $T^{ped}_e$ are found to be most sensitive to changes to $S^{sep}_{ion}$, as opposed to $n^{ped}_e$ and $T^{sep}_e$. Dimensionless quantities, namely α MHD and v*, are found to regulate attainable pedestal values. Select discharges at different values of P net and in different pumping configurations are analyzed further using SOLPS-ITER. It is determined that changes to plasma transport coefficients are required to self-consistently model both plasma and neutral edge dynamics. Pumping is found to modify the poloidal distribution of atomic neutral density, n 0 , along the separatrix, increasing n 0 at the active X-point. Opaqueness to neutrals from high n e in the divertor is found to play a role in mediating neutral penetration lengths and hence, the poloidal distribution of neutrals along the separatrix. Pumped discharges thus require a larger particle diffusion coefficient than that inferred purely from 1D experimental profiles at the outer midplane.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

A cryopump for cooling objects at a distance

Design and construction of cryopump is reported that feeds from primary source to cool component up to 30 ft from source. Liquid oxygen or nitrogen is gravity fed through loop system to copper fibers enclosing component at room temperature where fluid boils, cools object, vaporizes and recycles through tubing loop.

Batson, P. J.

Use of cryopumps on large space simulation systems

The need for clean, oil free space simulation systems has demanded the development of large, clean pumping systems. The assurance of optically dense liquid nitrogen baffles over diffusion pumps prevents backstreaming to a large extent, but does not preclude contamination from accidents or a control failure. Turbomolecular pumps or ion pumps achieve oil free systems but are only practical for relatively small chambers. Large cryopumps were developed and checked out which do achieve clean pumping of very large chambers. These pumps can be used as the original pumping system or can be retrofitted as a replacement for existing diffusion pumps.

Mccrary, L. E.

Cryopumping Field Joint Can Testing

For long installations, vacuum jacketed piping often comes in 40 foot sections that are butt welded together in the field. A short can is then welded over the bare pipe connection to allow for insulation to be protected from the environment. Traditionally, the field joint is insulated with multilayer insulation and a vacuum is pulled on the can to minimize heat leak through the bare section and prevent frost from forming on the pipe section. The vacuum jacketed lines for the Ares I mobile launch platform were to be a combined 2000 feet long, with 60+ pipe sections and field joint cans. Historically, Kennedy Space Center has drilled a hole in the long sections to create a common vacuum with the field joint can to minimize maintenance on the vacuum jacketed piping. However, this effort looked at ways to use a passive system that didn't require a vacuum, but may cryopump to create its own vacuum. Various forms of aerogel, multilayer insulations, and combinations thereof were tested to determine the best method of insulating the field joint while minimizing maintenance and thermal losses.

Johnson, Wesley L.