Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRYSTAL CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Liquid crystal calibrator

Calibration apparatus determines the operating temperature range /sensitivity/ of liquid crystals. The calibrator maintains a precisely controlled test surface temperature. It permits a measurement accuracy of plus or minus 0.5 degrees F and a sensitivity of plus or minus 0.15 degrees F.

Cohen, S. E.↗

The color bar phase meter: A simple and economical method for calibrating crystal oscillators

Comparison of crystal oscillators to the rubidium stabilized color burst is made easy and inexpensive by use of the color bar phase meter. Required equipment consists of an unmodified color TV receiver, a color bar synthesizer and a stop watch (a wrist watch or clock with sweep second hand may be used with reduced precision). Measurement precision of 1 x 10 to the minus 10th power can be realized in measurement times of less than two minutes. If the color bar synthesizer were commercially available, user cost should be less than $200.00, exclusive of the TV receiver. Parts cost for the color bar synthesizer which translates the crystal oscillator frequency to 3.579MHz and modulates the received RF signal before it is fed to the receiver antenna terminals is about $25.00. A more sophisticated automated version, with precision of 1 x 10 to the minus 11th power would cost about twice as much.

Davis, D. D.↗

NASA Glenn Propulsion Systems Lab: 2012 Inaugural Ice Crystal Cloud Calibration Procedure and Results

The inaugural calibration of the ice crystal and supercooled liquid water clouds generated in NASA Glenn's engine altitude test facility, the Propulsion Systems Lab (PSL) is reported herein. This calibration was in support of the inaugural engine ice crystal validation test. During the Fall of 2012 calibration effort, cloud uniformity was documented via an icing grid, laser sheet and cloud tomography. Water content was measured via multi-wire and robust probes, and particle sizes were measured with a Cloud Droplet Probe and Cloud Imaging Probe. The environmental conditions ranged from 5,000 to 35,000 ft, Mach 0.15 to 0.55, temperature from +50 to -35 F and relative humidities from less than 1 percent to 75 percent in the plenum.

ice clouds↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Modeling Ti–6Al–4V using crystal plasticity, calibrated with multi-scale experiments, to understand the effect of the orientation and morphology of the α and β phases on time dependent cyclic loading

Classically, crystal plasticity modeling has used a range of constitutive equations, in which the incorporation of additional physics-based relationships typically results in additional model parameters. These additional parameters need to be reliably calibrated, which often necessitates the use of a range of experimental data acquired at multiple length scales. In this work, a crystal plasticity based finite element (CPFE) model for a dual-phase Titanium alloy, Ti–6Al–4V, is developed. The α and β phases of the microstructure are explicitly modeled. The model is calibrated using a systematic optimization routine and experimental data that consist of macroscopic stress-strain curves coupled with lattice strains on different crystallographic planes for the two phases. These experimental data were obtained from in situ high energy X-ray diffraction experiments for multiple material pedigrees, with varying crystallographic orientation distribution and β volume fractions. Depending on the thermomechanical-processing route and the heat treatment used to manufacture the alloy, Ti–6Al–4V can exist in a wide number of microstructural forms, which often results in the α and β phases either having well aligned slip systems (following the Burgers orientation relationship (BOR)) or possessing no alignment of the slip systems across the interphase boundary (not following the BOR). In this study, the fully-calibrated CPFE model is used to gain a comprehensive understanding of the deformation behavior of Ti–6Al–4V, specifically, the effect of microstructures that follow the BOR (or not) on time-dependent cyclic loading (including the effects of dwell hold times).

36 MATERIALS SCIENCE↗

Direct sensitivity analysis on the parameterization of crystal plasticity models

Various methods for calibrating crystal plasticity finite element (CPFE) models lead to non-unique input parameter values, which subsequently introduce uncertainty in the predicted mechanical response. Sensitivity analysis (SA) conducted on crystal plasticity models is used to identify how variability in these parameters contribute to output uncertainty. Traditional SA on CPFE parameters uses simplified surrogate models to save computational time. However, the accuracy of the surrogate models depends on the quantity of training data used, and any modeling error can propagate into the SA results, potentially affecting their reliability. In this work, the elementary effects test (EET) method, a global SA technique using direct CPFE simulations was employed, and the results obtained were compared with the First Order Second Moment (FOSM) method. ExaConstit, an open-source GPU-enabled CPFE code, was used to perform the simulations and direct SA. The EET method was accurately able to capture the non-linear effects of all the input parameters on the output and is a valuable approach for reliably attributing parameter sensitivities in CPFE models. Based on the results, efficient strategies to perform future parameter calibration and SA are discussed. Additionally, the SA trends observed in different single crystal orientations closely mirrored the activity of the slip systems.

Elementary Effects Test↗

Calibrating Curved Crystals Used for Plasma Spectroscopy

The throughput and resolving power of an X-ray spectrometer that uses a curved crystal as the diffraction element is determined primarily by the crystal X-ray reflectivity properties. This poster presents a measurement technique for these crystal parameters using a simple diode source to produce a narrow spectral band. The results from measurements on concave elliptical polyethylene terephthalate (PET) crystals and convex potassium acid phthalate (KAP) crystals show large variations in the key parameters compared to those from the flat crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quartz Crystal Microbalance Operation and In Situ Calibration

Quartz crystal microbalances (QCMs) are commonly used to measure the rate of deposition of molecular species on a surface. The measurement is often used to select materials with a low outgassing rate for applications where the material has a line of sight to a contamination-sensitive surface. A quantitative, in situ calibration of the balance, or balances, using a pure material for which the enthalpy of sublimation is known, is described in this Technical Memorandum. Supporting calculations for surface dwell times of deposited materials and the effusion cell Clausing factor are presented along with examples of multiple QCM measurements of outgassing from a common source.

Albyn, K. C.↗

A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282

Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.

36 MATERIALS SCIENCE↗

An asynchronous parallel high-throughput model calibration framework for crystal plasticity finite element constitutive models

Crystal plasticity finite element model (CPFEM) is a powerful numerical simulation in the integrated computational materials engineering toolboxes that relates microstructures to homogenized materials properties and establishes the structure–property linkages in computational materials science. However, to establish the predictive capability, one needs to calibrate the underlying constitutive model, verify the solution and validate the model prediction against experimental data. Bayesian optimization (BO) has stood out as a gradient-free efficient global optimization algorithm that is capable of calibrating constitutive models for CPFEM. Here in this paper, we apply a recently developed asynchronous parallel constrained BO algorithm to calibrate phenomenological constitutive models for stainless steel 304 L, Tantalum, and Cantor high-entropy alloy.

304L stainless steel↗

Insitu Calibration of Quartz Crystal Microbalances

Computer models that predict the rate at which molecular contamination will deposit on optical surfaces typically use outgassing source terms, measured with quartz crystal microbalances, as a basis for the prediction. The American Society of Testing and Materials, Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials (Method E-1559), is probably the best know technique used by the aerospace community to measure the outgassing rates or source terms of materials. A simple method for the insitu calibration of quartz crystal microbalances, based on the heat of enthalphy of Adipic Acid, has been developed and demonstrated by the Marshall Space Flight Center, Environmental Effects Group. The calibration has been demonstrated over a sample temperature range of 25 to 66 degrees Celsius and deposition rates of 7 x 10 (exp -11) grams/cm(sup 2)-s and greater, for several measurement system configurations. This calibration technique is fully compatible with the American Society for Testing and Materials, Method E-1559, as well as other methodology. The calibration requires no modification of outgassing facilities employing an effusion cell and does not degrade the performance or function of typical vacuum systems.

Albyn, Keith↗