Search NASA⌕ Search

SEARCH · Search NASA

Results for “CSSX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Alternatives to Nitric Acid Stripping in the Caustic-Side Solvent Extraction (CSSX) Process for Cesium Removal from Alkaline High-Level Waste

Effective alternatives to nitric acid stripping in the Caustic-Side Solvent Extraction (CSSX) solvent have been demonstrated in this work. The CSSX solvent employs calix[4]arene-bis(tert-octylbenzo-18-crown-6) (BOBCalixC6) as the cesium extractant in a modified alkane diluent for decontamination of alkaline high-level wastes. Results reported in this paper support the idea that replacement of the nitrate anion by a much more hydrophilic anion like borate can substantially lower cesium distribution ratios on stripping. Without any other change in the CSSX flowsheet, however, the use of a boric acid stripping solution in place of the 1 mM nitric acid solution used in the CSSX process marginally, though perhaps still usefully, improves stripping. The less-than-expected improvement was explained by the carryover of nitrate from scrubbing into stripping. Accordingly, more effective stripping is obtained after a scrub of the solvent with 0.1 M sodium hydroxide. Functional alternatives to boric acid include sodium bicarbonate or cesium hydroxide as strip solutions. Profound stripping improvement is achieved when trioctylamine, one of the components of the CSSX solvent, is replaced with a commercial guanidine reagent (LIX 79). The more basic guanidine affords greater latitude in selection of aqueous conditions in that it protonates even at mildly alkaline pH values. Under process-relevant conditions, cesium distributions on stripping are decreased on the order of 100-fold compared with current CSSX performance. The extraction properties of the solvent were preserved unchanged over three successive extract-scrub-strip cycles. From the point of view of compatibility with downstream processing, boric acid represents an attractive stripping agent, as it is also a potentially ideal feed for borosilicate vitrification of the separated 137Cs product stream. Possibilities for use of these results toward a dramatically better next-generation CSSX process, possibly one employing the more soluble cesium extractant calix[4]arene-bis(2 ethylhexylbenzo-18-crown-6) (BEHBCalixC6) are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROBUSTNESS OF THE CSSX PROCESS TO FEED VARIATION: EFFICIENT CESIUM REMOVAL FROM THE HIGH POTASSIUM WASTES AT HANFORD

This contribution finds the Caustic-Side Solvent Extraction (CSSX) process to be effective for the removal of cesium from the Hanford tank-waste supernatant solutions. The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. By use of a computerized CSSX thermodynamic model, it was calculated that the higher levels of potassium depress the cesium distribution ratio (D{sub Cs}), as validated to within {+-}11% by the measurement of D{sub Cs} values on various Hanford waste-simulant compositions. A simple analog model equation that can be readily applied in a spreadsheet for estimating the D{sub Cs} values for the varying waste compositions was developed and shown to yield nearly identical estimates as the computerized CSSX model. It is concluded from the batch distribution experiments, the physical-property measurements, the equilibrium modeling, the flowsheet calculations, and the contactor sizing that the CSSX process as currently formulated for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds, albeit with more stages. For the most challenging Hanford waste composition tested, 31 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 2. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated based on experimental distribution ratios determined for an improved solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 0.010 M boric acid. The improved solvent and flowsheet can meet minimum requirements (DF = 5000 and CF = 2) with 15 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Thus, a modular CSSX application for the Hanford waste seems readily obtainable with further short-term development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) Process for Cesium Removal from High-Level Tank Waste

This paper describes the chemical performance of the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process in its current state of development for removal of cesium from the alkaline high-level tank wastes at the Savannah River Site (SRS) in the US Department of Energy (USDOE) complex. Overall, motivation for seeking a major enhancement in performance for the currently deployed CSSX process stems from needs for accelerating the cleanup schedule and reducing the cost of salt-waste disposition. The primary target of the NG-CSSX development campaign in the past year has been to formulate a solvent system and to design a corresponding flowsheet that boosts the performance of the SRS Modular CSSX Unit (MCU) from a current minimum decontamination factor of 12 to 40,000. The chemical approach entails use of a more soluble calixarene-crown ether, called MaxCalix, allowing the attainment of much higher cesium distribution ratios (DCs) on extraction. Concurrently decreasing the Cs-7SB modifier concentration is anticipated to promote better hydraulics. A new stripping chemistry has been devised using a vitrification-friendly aqueous boric acid strip solution and a guanidine suppressor in the solvent, resulting in sharply decreased DCs on stripping. Results are reported herein on solvent phase behavior and batch Cs distribution for waste simulants and real waste together with a preliminary flowsheet applicable for implementation in the MCU. The new solvent will enable MCU to process a much wider range of salt feeds and thereby extend its service lifetime beyond its design life of three years. Other potential benefits of NG-CSSX include increased throughput of the SRS Salt Waste Processing Facility (SWPF), currently under construction, and an alternative modular near-tank application at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

V5 and V10 Contactor Testing with the Next Generation (CSSX) Solvent for the Savannah River Site Integrated Salt Disposition Process

A solvent extraction system for removal of cesium (Cs) from alkaline solutions was developed utilizing a novel solvent invented at the Oak Ridge National Laboratory (ORNL). This solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix. A Modifier is added to the solvent to enhance the extraction power of the calixarene and to prevent the formation of a third phase. An additional additive, called a suppressor, is used to improve stripping performance. The process that deploys this solvent system is known as Caustic Side Solvent Extraction (CSSX). The solvent system has been deployed at the Savannah River Site (SRS) in the Modular CSSX Unit (MCU) since 2008.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PERFORMANCE TESTING OF THE NEXT-GENERATION CSSX SOLVENT WITH ACTUAL SRS TANK WASTE

Efforts are underway to qualify the Next-Generation Solvent for the Caustic Side Solvent Extraction (CSSX) process. Researchers at multiple national laboratories have been involved in this effort. As part of the effort to qualify the solvent extraction system at the Savannah River Site (SRS), SRNL performed a number of tests at various scales. First, SRNL completed a series of batch equilibrium, or Extraction-Scrub-Strip (ESS), tests. These tests used {approx}30 mL of Next-Generation Solvent and either actual SRS tank waste, or waste simulant solutions. The results from these cesium mass transfer tests were used to predict solvent behavior under a number of conditions. At a larger scale, SRNL assembled 12 stages of 2-cm (diameter) centrifugal contactors. This rack of contactors is structurally similar to one tested in 2001 during the demonstration of the baseline CSSX process. Assembly and mechanical testing found no issues. SRNL performed a nonradiological test using 35 L of cesium-spiked caustic waste simulant and 39 L of actual tank waste. Test results are discussed; particularly those related to the effectiveness of extraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CSSX Radiolytic H2 Generation ("Thermolysis") -- Final Report

The purpose of this work was to determine the radiolytic hydrogen gas yield of irradiated CSSX solvent at several temperatures. The active ingredient of this solvent is calix[4]arene-bis-(t-octylbenzo) crown-6, a calixarene crown ether used for cesium complexation. The solvent also contains 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, a fluorinated alcoholic solvent modifer used to improve the solubility of the calixarene and its cesium complex in the Isopar L diluent. Isopar L is a branch-chain alkane and comprises most of the mixture. Samples of this solution were irradiated to various absorbed ?-ray doses in gas-tight sample containers, which were then sampled for hydrogen gas content. The methods are described below.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

N,N'-DICYCLOHEXYL-N"-ISOTRIDECYLGUANIDINE AS SUPPRESSOR FOR THE NEXT GENERATION CAUSTIC SIDE SOLVENT EXTRACTION (NG-CSSX) PROCESS

ABSTRACT The purity, concentration, and source of the N,N'-dicyclohexyl-N"-isotridecylguanidine (DCiTG) suppressor (guanidine) used in the NG-CSSX process were found to influence solvent performance. As the starting isotridecanol used in the preparation of DCiTG is comprised of a mixture of branched-chain aliphatic alcohols, varying in composition with manufacturer, the resulting DCiTG itself is a mixture. Thus, it is necessary to address how the solvent performance will be affected by the different preparations of the DCiTG solvent component. In this study, four preparations of DCiTG from three sources were analyzed and evaluated for purity and performance, both in the absence and presence of an anionic surfactant impurity.

DCITG↗

Dynamic Surface Tension and Diffusivity Measurements of NG-CSSX Next Generation Solvent

Since 2008, the Savannah River Site has processed more than four million gallons of radioactive supernatant. To continue compliance with downstream processes, MCU is switching to the improved solvent called Next Generation Solvent (NG-CSSX). The new solvent formulation promises higher cesium removal efficiency and laboratory testing suggests the potential of higher processing rates. Similarly, laboratory testing demonstrated improvements in separation of the solvent from the effluent aqueous streams. To complete implementation at MCU, additional work was needed to develop methods that can measure physical properties relevant to the performance of the new solvent. This work measures two relevant physical properties: static interfacial tension and diffusvity. Both properties play a relevant role in mixing and separating immiscible liquids. This work evaluated the impact of changes in composition or aqueous phase on these physical properties to gauge the sensitivity of the system to the losses of chemical components.

Fondeur, F. F.↗

Impacts of Guanidine Degradation Products on Next Generation Solvent (NGS) Caustic Side Solvent Extraction (CSSX) Processing

Savannah River National Laboratory researchers have been requested to perform testing to assess the potential for build-up of guanidine degradation compounds in the Next Generation Solvent Caustic Side Solvent Extraction process. Testing was also requested to determine the impact of guanidine degradation compounds [3,7-dimethyloctylamine (iDA) and Bis-N,N’-(3,7-dimethyloctyl)urea (DiDU)] on cesium behavior in the flowsheet. Twelve partitioning experiments were performed to quantify the partitioning coefficient of identified guanidine degradation compounds in various organic-aqueous mixtures. Six Extraction, Scrub, and Strip (ESS) experiments were performed to quantify the impact of degradation products on cesium behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Modular CSSX Unit (MCU) Operations

Tiina Laupa and Mark Geeting of SRS: Savannah River Remediation group discuss the use of Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU) at the site, how it has performed, improvements made, and future work. One of these improvements, the use of next-generation solvents (NGS), is further discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Density of Next-Generation Caustic-Side Solvent Extraction Solvent

This report recommends the appropriate modifier concentration to employ in the Next Generation Solvent (NGS) to be used in the Salt Waste Processing Facility (SWPF) at the Savannah River Site for removal of cesium from legacy tank waste. The Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing the NGS is a marked improvement over the original Caustic-Side Solvent Extraction (CSSX) process, as it provides more effective removal of cesium from highly alkaline radioactive wastes and concentrates this removed cesium into an aqueous solution that is easy to vitrify for final disposal. Considerable effort has been devoted to optimizing the chemistry and process conditions of both systems, and their effectiveness has been demonstrated at the pilot scale at the Modular CSSX Unit (MCU). Due to the success of the demonstration and pilot-scale tests, the Salt Waste Processing Facility (SWPF) has been built to process larger volumes of waste with the CSSX process. To accelerate the waste-processing rate of the SWPF beyond its design throughput, plans call for the replacement of the CSSX process by the NG-CSSX process. To implement the NG-CSSX process in equipment optimized for CSSX, adjusting the density of the NGS to match the CSSX solvent density of 0.851 ± 0.0008 g/mL is considered advisable to obtain comparable hydraulic performance. Toward this objective, the density of the NGS has been measured at different temperatures and modifier concentrations to determine that a concentration of 0.650 M Cs-7SB modifier provides the best match for the desired density.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Flowsheet for the Next Generation GSSX Process in the MCU: Report for FY2010

The Next Generation Caustic Side Solvent Extraction (NG-CSSX) flowsheet is being developed in a collaboration among Oak Ridge National Laboratory (ORNL), Argonne National Laboratory (ANL), and Savannah River National Laboratory (SRNL) for the Modular CSSX Unit (MCU) facility at the Savannah River Site (SRS). This work is being done in cooperation with two groups at SRS (my principal contacts there are Mark Geeting, SRR, and Sam Fink, SRNL) and with one group at Oak Ridge National Laboratory (my principal contact there is Bruce Moyer). The evaluation of the various NG-CSSX solvent candidates was done using the SASSE (Spreadsheet Algorithm for Stagewise Solvent Extraction) program with cesium distribution coefficient (D Cs ) values supplied by ORNL. The final optimized solvent composition has 50 mM MaxCalix as the extractant. Using the SASSE spreadsheet to calculate the Cs decontamination factor (D.F.) as well as ROTOR program to evaluate contactor rotor throughputs, an initial flowsheet was developed for the optimized NG-CSSX solvent. The current CSSX flowsheet for the MCU at its maximum salt feed flow rate is shown in Fig. 1. The initial NG-CSSX flowsheet for the MCU at its targeted maximum salt feed flow rate is shown in Fig. 2. Comparing these two flowsheets, one can see that, for the NG-CSSX flowsheet, the maximum flow rate of the salt feed (DF) is increased 41%, from 8.5 gpm to 12.0 gpm. At the same time, because of the high concentration of the MaxCalix extractant in the NG-CSSX solvent, the Cs decontamination factor (D.F.) for the aqueous effluent from the extraction section (DW, the aqueous raffinate) is increased from 12 to 40,000. As required, the Cs concentration factor (C.F.) for the aqueous effluent from the strip section (EW) is maintained at 15.

Leonard, Ralph↗

Literature Review on Next Generation Solvent Isopar ® L Vapor Pressure Curve and the Partitioning of its Modifier and Extractant

The Next Generation Solvent (NGS) is set to replace the Original Caustic Side Solvent Extractant (CSSX) at the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC), formerly Savannah River Remediation (SRR), to perform a literature review on the following topics to address flammability concerns with the current solvent: Isopar ® L vapor pressure curve for NGS, partitioning ratio for the extractant MaxCalix and the modifier Cs-7SB, and high cesium concentration impacts on NGS radiolysis and potential solvent degradation rates in high cesium concentrations. The following conclusions and recommendations are made based on previous experimental work and literature: (1) Current SWPF flammable gas generation calculations use an Isopar ® L vapor pressure curve based on experimental testing with the Original CSSX solvent. No such testing to date has been performed with NGS. It is suggested that the decrease in Cs-7SB concentration for NGS compared to the Original CSSX solvent would lead to a slightly higher vapor pressure at all temperatures in SWPF vessels. A bounding NGS vapor pressure curve has been provided; it is recommended to see if these values would challenge current flammability controls and to perform testing if needed.(2) The partitioning ratio for Cs-7SB is known in the Original CSSX solvent with dilute nitric acid and caustic solutions. No tests could be found for the partitioning of Cs-7SB to dilute boric acid solutions; however, a similar partitioning ratio is expected. Due to the lipophilic alkyl chains on MaxCalix, it is expected to be even less soluble than BOBCalixC6 in the aqueous phase and should not be considered a significant contributor to the f organic term. Additionally, the reaction rate of N,N’,N’’-Tris(3,7-dimethyloctyl)guanidine (TiDG) or its degradation products with a hydrogen radical should be estimated/determined if they are found to be significant contributors to the f organic term. (3) NGS is expected to see much higher Cs concentrations at SWPF in comparison to its use at the Modular CSSX Unit (MCU). These higher Cs concentrations could influence radiolytic degradation rates of the solvent. NGS appears to be fairly stable to radiolytic degradation based on previous testing and its use at MCU. However, there has not been radiolytic flammable gas generation testing with NGS to date. There is a risk that the continued use of G-values obtained for flammable gases produced from the irradiation of the Original CSSX solvent is not bounding for NGS, but this is considered a very low risk due to the similarities in the composition of the solvents, as well as the conservatisms in the experimental design of the Original CSSX testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disulfonamide Ligands as f-Element Extractants from Alkaline High-Level Waste

Almost 100 million gallons of high level waste (HLW) has been generated from defense reprocessing programs to support nuclear weapons production. HLW is currently stored at the Hanford and Savannah River Sites (SRS) [1]. It contains radioactive components, such as {sup 137}Cs, {sup 99}Tc and {sup 90}Sr, as well as large amounts of non-radioactive species, including solvated cations and insoluble metal hydroxides. HLW has high concentration of soluble hydroxides ([OH{sup -}] = 2 M at SRS [2]), complexing inorganic anions ([NO{sub 3}{sup -}] ∼ 0.65 - 3.7 M at SRS [2]) and a high ionic strength. Even though the majority of actinide component in alkaline HLW is precipitated, studies of An(III) and Ln(III) complexation in highly alkaline solutions in the presence of high nitrate concentrations have showed that soluble nitrate complexes can be formed [3]. The current treatment of HLW at SRS currently consists of two processes: The Actinide Removal Process (ARP) and the Next-Generation Caustic-Side Solvent Extraction process (NG-CSSX). Strontium and actinides are removed by sorption on monosodium titanate through the Actinide Removal Process (ARP) commonly referred to as the alpha-strike step [4]. Then, cesium is selectively extracted from the alkaline media via the Caustic-Side Solvent Extraction (CSSX) process [5]. The CSSX solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix containing i) a solvent modifier (alkylphenoxy alcohol) which increases extractant solubility and prevents third phase formation, and ii) a suppressor (trioctylamine or guanidine) - that mitigates surfactant effects. The CSSX process removes {sup 137}Cs selectively and rapidly, yet the post- CSSX aqueous stream may still contain high amounts of An, thus requiring a second ARP treatment (referred to as 'alpha-finishing') for some tanks. Despite the success of the ARP process in removing Sr and An, it often represents the kinetic bottleneck of integrated processing, as it is slower than solvent extraction. Understanding the complexation of actinides by organic ligands that are compatible with the CSSX process could eventually lead to a combined caustic-side Cs/Sr/actinide extraction process with better economics due to a reduced amount of monosodium titanate and/or a shorter required contact time with titanate during ARP. This would ensure a low-activity waste (LAW) stream with no actinides without additional ARP processing post-CSSX. Disulfonamides were studied for extraction of Sm(III) from alkaline aqueous media of pH 10-14 into dichloromethane. Up to 82% of Sm(III) was extracted from solutions of pH 12.5 -13.5 and up to 84% from solutions of pH 10.5 - 11.5. These results show some resemblance with Am extraction results by calixarene ligands previously reported [10]. Kinetic studies demonstrated that even 5 min is enough to complete stripping, whereas extraction is time-limiting process and requires up to 20 h for efficient removal of Sm(III) from alkaline aqueous media. Determination of composition of complexes in solution after extraction by the equilibrium shift method showed a 1:1 Sm(III):dsa-2 complexation ratio for the extracted species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Caustic-Side Solvent Extraction Full-Scale Test

A Full-Scale Test (FST) program was performed by Parsons and its team members General Atomics and Energy Solutions to assess the performance of full-scale centrifugal contactors specified for the Department of Energy Salt Waste Processing Facility (SWPF). The SWPF, to be located at the Savannah River Site (SRS) in Aiken, South Carolina, will remove highly radioactive waste constituents, principally actinides, strontium (Sr), and cesium (Cs) radionuclides, from salt waste solutions currently stored in SRS high-level waste tanks. Caustic-side Solvent Extraction (CSSX) removes Cs from waste feed that has been treated upstream to remove actinides and Sr. CSSX uses a custom solvent to extract Cs from the salt solution in a series of single stage centrifugal contactors. The test system comprised (a) eleven 25.4 cm (10'') full-scale contactors (versus 36 in SWPF) for the extraction, scrub, strip, and wash stages; (b) two solvent recovery coalescers; and (c) the associated hardware and control system, packaged in four skid mounted modules. This paper describes the results of tests performed to define both hydraulic performance parameters (maximum hydraulic capacity and phase carryover) and solvent extraction performance parameters (Cs mass transfer efficiencies) using simulated SWPF waste and actual CSSX solvent. The test results confirmed key design features of the CSSX process and, as a consequence, the use of CSSX in the SWPF. In conclusion: Total throughput was initially limited to 85% of maximum flow during FST. Minor system modifications performed prior to mass transfer testing series resulted in the realization of 100% throughput. The 100% flow equates to slightly more than 35.6 x 10{sup 6} L/yr (9.4 Mgal/yr) of waste processed in SWPF which is anticipated to be the peak plant throughput. To achieve the best hydraulic performance in extraction, it is recommended that the extraction contactors be operated at the highest reasonable speed possible (>2100 rpm). Vibration, hardware limitations, bearing life, and other factors should be considered prior to final selection of extraction contactor speeds in SWPF. In strip (also scrub and wash) aqueous carryover decreased and organic carryover increased as the rotor speeds increased. It is recommended that the strip, scrub, and wash contactors be operated at intermediate speeds (between 1500 and 2100 rpm) to achieve a performance compromise between aqueous and organic carryover. Curved-vane bottom plates showed a significant hydraulic performance (aqueous and organic carryover) advantage over straight-vane bottom plates in extraction. There was no significant mass transfer performance advantage for either plate type in extraction. Thus, curved-vane bottom plates in extraction may be the better option for use in SWPF. There was no significant hydraulic performance difference between the plate types in strip. Straight-vanes provided significantly better mass transfer performance in strip compared to curved-vanes. Based solely on mass transfer performance, straight-vane bottom plates in the strip, scrub, and wash contactors are recommended for use in SWPF. Utilizing straight-vanes in the stripping section, the overall SWPF CSSX performance is expected to meet or exceed the target DF of 40,000 with minimum extraction D{sub Cs} of 10. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent Vapor Pressure Testing

Previous work by Savannah River National Laboratory (SRNL) indicated that the actual Next Generation Solvent vapor pressure would be higher than the Original Caustic Side Solvent Extraction (CSSX) solvent vapor pressure, but below a bounding vapor pressure using Raoult’s Law. Since solvent vapor pressure has a significant impact on Composite Lower Flammability Limits (CLFL) and attendant accident analyses, obtaining an additional margin from the bounding NGS vapor pressure would be valuable. In order to quantify how much margin might be gained from the NGS bounding solvent, SRNL researchers were requested to perform vapor pressure testing with the Next Generation Solvent (NGS) by Savannah River Mission Completion (SRMC). The vapor pressure curve for the NGS formulation set to be deployed at the Salt Waste Processing Facility (SWPF) has been determined by SRNL up to 55°C (131°F) using headspace Gas Chromatography (GC). It was expected that NGS would have a higher vapor pressure than the Original CSSX solvent; however, experimental results indicate a lower vapor pressure. At this time, it is uncertain if this difference is due to the 7x increase in concentration of the large calixarene in the solvent (0.007M BOBCalix in Original CSSX solvent vs. 0.05M MaxCalix in NGS) or to minor batch-to-batch variations in Isopar-L constituents. The NGS and the Original CSSX solvent vapor pressure data were fitted to the Antoine Equation. The Antoine equation gives a more accurate representation of the expected vapor pressure of the solvents outside of the temperature range tested. The Antoine equation fitting for NGS is given below: $P=10^{6.364⁻\frac{1788.4}{T+219.3}}$. Where, p is the vapor pressure (partial pressure) of NGS in mmHg and T is the temperature in °C. It is recommended that SRMC either continue using the more conservative Isopar-L vapor pressure calculations at SWPF with the equation developed for the Original CSSX solvent, or the equation presented above for the NGS solvent. Additionally, it is recommended to study the variability in Isopar-L vapor pressure between lots.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Caustic-Side Solvent-Extraction Modeling for Hanford Interim Pretreatment System

The purpose of this work is to examine the applicability of the Caustic-Side Solvent Extraction (CSSX) process for the removal of cesium from Hanford tank-waste supernatant solutions in support of the Hanford Interim Pretreatment System (IPS). The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. It was confirmed by use of the CSSX model that the higher levels of potassium depress the cesium distribution ratio (DCs), as validated by measurement of DCs values for four of eight specified Hanford waste-simulant compositions. The model predictions were good to an apparent standard error of ±11%. It is concluded from batch distribution experiments, physical-property measurements, equilibrium modeling, flowsheet calculations, and contactor sizing that the CSSX process as currently employed for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds. For the most challenging waste composition, 41 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 5. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated for a new solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 10 mM boric acid. The improved system can meet minimum requirements (DF = 5000 and CF = 5) with 17 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Potential benefits of further research and development are identified that would lead to reduced costs, greater adaptability of the process to DOE alkaline salt wastes, and greater readiness for implementation. Such benefits accrue from optimal sizing of centrifugal contactors for application of the CSSX process for the IPS; more accurate modeling of cesium extraction with greater flexibility and applicability to a variety of feeds and flowsheet conditions; and further improving and optimizing the alternative CSSX solvent and scrub/strip system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗