Search NASA⌕ Search

SEARCH · Search NASA

Results for “CTA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT

Objective: To assess the feasibility of creating virtual monoenergetic arterial images from venous phase CTA obtained on a detector-based spectral CT scanner and quantitatively compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios of the major arteries to those on polyenergetic true arterial phase images. Methods: In this retrospective study, 23 patients (15 men and 8 women, median age 68 years) who underwent triple-phase CTA on a spectral CT scanner for aortic endograft surveillance were included. The venous phase CTA of each study was reconstructed to generate virtual monoenergetic images at various keV, which were compared to true arterial phase CTA images. SNR and CNR of the aortoiliac arteries were evaluated by testing the differences in means and non-inferiority of virtual arterial images to true arterial images. Effective radiation dose was calculated for standard triple-phase studies in comparison with dual-phase and single-phase spectral CT examinations. Results: Virtual monoenergetic images demonstrated non-inferior (P < 0.05) arterial SNR and CNR compared to true arterial images at 40 keV for all arteries, at 45–50 keV for the thoracic and suprarenal aorta, and at 45–55 keV for the infrarenal aorta and iliac arteries. Significantly higher (P < 0.05) arterial attenuation was obtained at 40 keV for the aortoiliac arteries. Mean effective dose for conventional triple-phase studies was 32.5 mSv in comparison with 21.3 mSv for dual-phase non-contrast/venous scans and 11.3 mSv for single-phase venous scans. Conclusions: Detector-based spectral CT enables creation of virtual monoenergetic arterial images from venous phase CTA with equivalent and in some cases significantly higher SNR/CNR of major arteries compared to images from true arterial phase polyenergetic CTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extragalactic photon-ALP conversion at CTA energies

Magnetic fields in extragalactic space between galaxy clusters may induce conversions between photons and axion-like particles (ALPs), thereby shielding the photons from absorption on the extragalactic background light. For TeV gamma rays, the oscillation length (l osc ) of the photon-ALP system becomes inevitably of the same order as the coherence length of the magnetic field l and the length over which the field changes significantly (transition length l t ) due to refraction on background photons. We derive exact statistical evolution equations for the mean and variance of the photon and ALP transfer functions in the non-adiabatic regime (l osc ~ l >> l t ). We also make analytical predictions for the transfer functions in the quasi-adiabatic regime (l osc < t ). Our results are important in light of the upcoming Cherenkov Telescope Array (CTA), and may also be applied to models with non-zero ALP masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study

Purpose: Computed tomography angiography (CTA) is increasingly used for the diagnosis of coronary artery disease (CAD). However, CTA is not commonly used for the assessment of ventricular and atrial function, although functional information extracted from CTA data is expected to improve the diagnostic value of the examination. In clinical practice, the extraction of ventricular and atrial functional information, such as stroke volume and ejection fraction, requires accurate delineation of cardiac chambers. In this paper, we investigated the accuracy and robustness of cardiac chamber delineation using a multiatlas based segmentation method on multicenter and multivendor CTA data. Methods: A fully automatic multiatlas based method for segmenting the whole heart (i.e., the outer surface of the pericardium) and cardiac chambers from CTA data is presented and evaluated. In the segmentation approach, eight atlas images are registered to a new patient's CTA scan. The eight corresponding manually labeled images are then propagated and combined using a per voxel majority voting procedure, to obtain a cardiac segmentation. Results: The method was evaluated on a multicenter/multivendor database, consisting of (1) a set of 1380 Siemens scans from 795 patients and (2) a set of 60 multivendor scans (Siemens, Philips, and GE) from different patients, acquired in six different institutions worldwide. A leave-one-out 3D quantitative validation was carried out on the eight atlas images; we obtained a mean surface-to-surface error of 0.94{+-}1.12 mm and an average Dice coefficient of 0.93 was achieved. A 2D quantitative evaluation was performed on the 60 multivendor data sets. Here, we observed a mean surface-to-surface error of 1.26{+-}1.25 mm and an average Dice coefficient of 0.91 was achieved. In addition to this quantitative evaluation, a large-scale 2D and 3D qualitative evaluation was performed on 1380 and 140 images, respectively. Experts evaluated that 49% of the 1380 images were very accurately segmented (below 1 mm error) and that 29% were accurately segmented (error between 1 and 3 mm), which demonstrates the robustness of the presented method. Conclusions: A fully automatic method for whole heart and cardiac chamber segmentation was presented and evaluated using multicenter/multivendor CTA data. The accuracy and robustness of the method were demonstrated by successfully applying the method to 1420 multicenter/multivendor data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment is achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.

60 APPLIED LIFE SCIENCES↗

Sensitivity of CTA to dark matter signals from the Galactic Center

The Galactic Center is one of the most promising targets for indirect detection of dark matter with gamma rays. We investigate the sensitivity of the upcoming Cherenkov Telescope Array (CTA) to dark matter annihilation and decay in the Galactic Center. As the inner density profile of the Milky Way's dark matter halo is uncertain, we study the impact of the slope of the Galactic density profile, inwards of the Sun, on the prospects for detecting a dark matter signal with CTA. Adopting the Ring Method to define the signal and background regions in an ON-OFF analysis approach, we find that the sensitivity achieved by CTA to annihilation signals is strongly dependent on the inner profile slope, whereas the dependence is more mild in the case of dark matter decay. Surprisingly, we find that the optimal choice of signal and background regions is virtually independent of the assumed density profile. For the fiducial case of a Navarro-Frenk-White profile, we find that CTA will be able to probe annihilation cross-sections well below the canonical thermal relic value for dark matter masses from a few tens of GeV up to ∼ 5 TeV for annihilation to τ{sup +}τ{sup −}, and will achieve only a slightly weaker sensitivity for annihilation to b b-bar or μ{sup +}μ{sup −}. CTA will improve significantly on current sensitivity to annihilation signals for dark matter masses above ∼ 100 GeV, covering parameter space that is complementary to that probed by searches with the Fermi Large Area Telescope. The interpretation of apparent excesses in the measured cosmic-ray electron and positron spectra as signals of dark matter decay will also be testable with CTA observations of the Galactic Center. We demonstrate that both for annihilation and for decay, including spectral information for hard channels (such as μ{sup +}μ{sup −} and τ{sup +}τ{sup −}) leads to enhanced sensitivity for dark matter masses above m{sub DM} ∼ 200 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Model generation of coronary artery bifurcations from CTA and single plane angiography

Purpose: To generate accurate and realistic models of coronary artery bifurcations before and after percutaneous coronary intervention (PCI), using information from two image modalities. Because bifurcations are regions where atherosclerotic plaque appears frequently and intervention is more challenging, generation of such realistic models could be of high value to predict the risk of restenosis or thrombosis after stent implantation, and to study geometrical and hemodynamical changes. Methods: Two image modalities have been employed to generate the bifurcation models: computer tomography angiography (CTA) to obtain the 3D trajectory of vessels, and 2D conventional coronary angiography (CCA) to obtain radius information of the vessel lumen, due to its better contrast and image resolution. In addition, CCA can be acquired right before and after the intervention in the operation room; therefore, the combination of CTA and CCA allows the generation of realistic preprocedure and postprocedure models of coronary bifurcations. The method proposed is semiautomatic, based on landmarks manually placed on both image modalities. Results: A comparative study of the models obtained with the proposed method with models manually obtained using only CTA, shows more reliable results when both modalities are used together. The authors show that using preprocedure CTA and postprocedure CCA, realistic postprocedure models can be obtained. Analysis carried out of the Murray's law in all patient bifurcations shows the geometric improvement of PCI in our models, better than using manual models from CTA alone. An experiment using a cardiac phantom also shows the feasibility of the proposed method. Conclusions: The authors have shown that fusion of CTA and CCA is feasible for realistic generation of coronary bifurcation models before and after PCI. The method proposed is efficient, and relies on minimal user interaction, and therefore is of high value to study geometric and hemodynamic changes of treated patients.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

60 APPLIED LIFE SCIENCES↗

Relation between quantitative coronary CTA and myocardial ischemia by adenosine stress myocardial CT perfusion

Background: Coronary-computed tomography angiography (CTA) has limited accuracy to predict myocardial ischemia. Besides luminal area stenosis, other coronary plaque morphology and composition parameters may help to assess ischemia. With the integration of coronary CTA and adenosine stress CT myocardial perfusion (CTP), reliable information regarding coronary anatomy and function can be derived in one procedure. This analysis aimed to investigate the association between coronary stenosis severity, plaque composition and morphology and the presence of ischemia measured with adenosine stress myocardial CTP. Methods and Results: 84 patients (age, 62 ± 10 years; 48% men) who underwent sequential coronary CTA and adenosine stress myocardial CT perfusion were analyzed. Automated quantification was performed in all coronary lesions (quantitative CTA). Downstream myocardial ischemia was assessed by visual analysis of the rest and stress CTP images and defined as a summed difference score of ≥1. One or more coronary plaques were present in 146 coronary arteries of which 31 (21%) were ischemia-related. Of the lesions with a stenosis percentage <50%, 50%-70%, and >70%, respectively, 9% (6/67), 18% (9/51), and 57% (16/28) demonstrated downstream ischemia. Furthermore, mean plaque burden, plaque volume, lesion length, maximal plaque thickness, and dense calcium volume were significantly higher in ischemia-related lesions, but only stenosis severity (%) (OR 1.06; 95% CI 1.02-1.10; P = .006) and lesion length (mm) (OR 1.26; 95% CI 1.02-1.55; P = .029) were independent correlates. Conclusions: Increasing stenosis percentage by quantitative CTA is positively correlated to myocardial ischemia measured with adenosine stress myocardial CTP. However, stenosis percentage remains a moderate determinant. Lumen area stenosis and lesion length were independently associated with ischemia, adjusted for coronary plaque volume, mean plaque burden, maximal lesion thickness, and dense calcium volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE DISCOVERY OF HOST GALAXY H I ABSORPTION IN CTA 21

We report the discovery of H I 21 cm absorption toward the well-studied Gigahertz peaked spectrum source CTA 21 (4C 16.09) using the Arecibo telescope on 2009 September 20 and 21. Recently, the frequency band between 700 and 800 MHz was temporarily opened up to radio astronomy when US TV stations were mandated to switch from analog to digital transmissions, with new frequency allocations. The redshifted H I frequency for CTA 21 falls within this band. CTA 21 has a complex radio structure on a range of scales. The innermost prominent components are separated by {approx}12 mas while weak diffuse emission extends for up to {approx}300 mas. The H I absorption profile that we find has two main components, one narrow and the other wider and blueshifted. The total H I column density is 7.9 x 10{sup 20} cm{sup -2}, assuming a covering factor of unity and a spin temperature of 100 K. This H I absorption confirms the recently determined optical redshift of this faint galaxy of z {approx} 0.907. We discuss this new detection in light of H I absorption studies toward compact radio sources, and also the possibility that CTA 21 may be exhibiting multiple cycles of nuclear activity. This new detection in CTA 21 is consistent with a strong trend for detection of H I absorption in radio galaxies with evidence of episodic nuclear/jet activity.

79 ASTRONOMY AND ASTROPHYSICS↗

The CTA aims at the Inert Doublet Model

We show that the Cherenkov Telescope Array (CTA) can realistically challenge the Inert Doublet Model, one of the simplest and best known models of dark matter. Specifically, the CTA may exclude its heavy regime up to dark matter masses of 800 GeV and probe a large fraction of the remaining viable parameter space at even higher masses. Two features of the Inert Doublet Model make it particularly suitable for CTA searches. First, the dark matter mass (in the heavy regime) must be larger than 500 GeV. Second, the dark matter annihilation cross section, σ v, is always larger than the thermal one, reaching values as high as 10{sup −25} cm{sup 3}s{sup −1}. This higher value of σv is the result of the unavoidable coannihilation effects that determine the relic density via thermal freeze-out in the early Universe. We find that with 100 hours of Galactic Center exposure, CTA's expected limit widely surpasses, even after the inclusion of systematic errors, current and projected bounds from Fermi-LAT and HESS on this model.

79 ASTRONOMY AND ASTROPHYSICS↗

Design Concepts for the Cherenkov Telescope Array CTA: An Advanced Facility for Ground-Based High-Energy Gamma-Ray Astronomy

Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Fusion of Preprocedural CTA with Real-time Fluoroscopy to Guide Proper Hepatic Artery Catheterization During Transarterial Chemoembolization of Hepatocellular Carcinoma: A Feasibility Study

To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-time X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CTA simulations with CORSIKA/sim lowbar telarray

While current atmospheric Cherenkov installations consist of only a few telescopes each, future installations will be far more complex. Monte Carlo simulations have become an essential tool for the design and optimisation of such installations. The CORSIKA air-shower simulation code and the sim lowbar telarray code for simulation of arrays of Cherenkov telescopes have been used to simulate several candidate configurations of the future Cherenkov Telescope Array (CTA) in detail. Together with other detailed and simplified simulations the resulting data provide the basis for the ongoing optimisation of CTA over a wide energy range. In this paper, the simulation methods are outlined and preliminary results on a number of configurations are presented. It is demonstrated that the initial goals of the CTA project can be achieved with available technology, at least in the medium and high energy range (about 100 GeV to 100 TeV)

79 ASTRONOMY AND ASTROPHYSICS↗

SIMULTANEOUS MULTIWAVELENGTH AND OPTICAL MICROVARIABILITY OBSERVATIONS OF CTA 102 (PKS J2232+1143)

We present analysis of both the short-term optical and long-term multiwavelength variability of CTA 102. In 2004, this object was observed in an intense optical flaring state. Extensive R-band microvariability observations were carried out during this high state. In 2005, we obtained several weeks of contemporaneous radio, optical, and X-ray observations of CTA 102. These observations recorded distinct flaring activity in all three wavebands. Subsequent analysis revealed that this object may appear redder when in a brighter optical state, and that the X-ray, optical, and radio activity do not appear to be correlated. The shape of the observed spectral energy distributions suggests that both synchrotron-related and external inverse Compton processes may contribute to the X-ray emission. Our results are also compared to other results on this object and archival microvariability observations. It appears that more rapid, dramatic microvariability events occur when CTA 102 is in an elevated optical flux state.

07 ISOTOPE AND RADIATION SOURCES↗

A realistic assessment of the CTA sensitivity to dark matter annihilation

We estimate the sensitivity of the upcoming CTA gamma-ray observatory to DM annihilation at the Galactic centre, improving on previous analyses in a number of significant ways. First, we perform a detailed analyses of all backgrounds, including diffuse astrophysical emission for the first time in a study of this type. Second, we present a statistical framework for including systematic errors and estimate the consequent degradation in sensitivity. These errors may come from e.g. event reconstruction, Monte Carlo determination of the effective area or uncertainty in atmospheric conditions. Third, we show that performing the analysis on a set of suitably optimised regions of interest makes it possible to partially compensate for the degradation in sensitivity caused by systematics and diffuse emission. To probe dark matter with the canonical thermal annihilation cross-section, CTA systematics like non-uniform variations in acceptance over a single field of view must be kept below the 0.3% level, unless the dark matter density rises more steeply in the centre of the Galaxy than predicted by a typical Navarro-Frenk-White or Einasto profile. For a contracted r{sup −1.3} profile, and systematics at the 1% level, CTA can probe annihilation to b b-bar at the canonical thermal level for dark matter masses between 100 GeV and 10 TeV.

79 ASTRONOMY AND ASTROPHYSICS↗

On the sensitivity of CTA to gamma-ray boxes from multi-TeV dark matter

Collider, direct and indirect searches for dark matter have typically little or no sensitivity to weakly interacting massive particles (WIMPs) with masses above a few TeV. This rather unexplored regime can however be probed through the search for distinctive gamma-ray spectral features produced by the annihilation of WIMPs at very high energies. Here we present a dedicated search for gamma-ray boxes—sharp spectral features that cannot be mimicked by astrophysical sources—with the upcoming Cherenkov Telescope Array (CTA). Using realistic projections for the instrument performance and detailed background modelling, a profile likelihood analysis is implemented to derive the expected upper limits and sensitivity reach after 100 h of observations towards a 2°×2° region around the Galactic centre. Our results show that CTA will be able to probe gamma-ray boxes down to annihilation cross sections of 10{sup −27}−10{sup −26} cm{sup 3}/s up to tens of TeV. We also identify a number of concrete particle physics models providing thermal dark matter candidates that can be used as target benchmarks in future search campaigns. This constitutes a golden opportunity for CTA to either discover or rule out multi-TeV thermal dark matter in a corner of parameter space where all other experimental efforts are basically insensitive.

79 ASTRONOMY AND ASTROPHYSICS↗