Search NASA⌕ Search

SEARCH · Search NASA

Results for “CTBTO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Assessment of the CTBTO Noble Gas Network to Detect Nuclear Explosions

Atmospheric radioxenon levels are monitored worldwide by the Comprehensive Nuclear-Test-Ban Treaty Organisation (CTBTO) to detect emissions from nuclear explo-sions. Our paper examines the global network that has been set up to take routine air samples and to determine the atmospheric radioxenon concentrations. It is hypothesised that the monitoring system aims at the detection and localisation of radioxenon relea-ses. Both capabilities are dependent on background levels, explosive yields, leakage rates, transport time, choice of xenon isotope and number and locations of monitoring stations. And for each parameter, the global capabilities to detect and localise emissions from nuclear explosions are analysed. Recommendations for the future of the background sources and the development of the monitoring system are derived.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of CEA SMAD Digitizer for CTBTO-IMS Application (2012)

Sandia National Laboratories has tested and evaluated the new SMAD digitizer (revision A) design by CEA, France. The digitizer was tested at the acquisition rate of 50 Hz and gain factors of 1x, 2x, 4x, and 8x. The purpose of this digitizer evaluation was to perform seismic system noise analysis with estimates of system band-width dynamic range for an STS2 application and to determine the following device specifications: bit-weight, input terminated noise with a 2x50 Ohms load, bandwidth limited dynamic range, power consumption, common-mode rejection, cross-talk, analog bandwidth, relative transfer function, total harmonic distortion, time-tag accuracy, time-tag statistics, and time-tag drift. The test results included in this report were in response to static and to tonal-dynamic input signals. Wherever possible test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters.

42 ENGINEERING↗

The 2014 Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty revisited: The case for data fusion

The International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) uses a global network of radionuclide monitoring stations to detect evidence of a nuclear explosion. The two radionuclide technologies employed—particulate and noble gas (radioxenon) detection—have applications for data fusion to improve detection of a nuclear explosion. Using the hypothetical 0.5 kT nuclear explosive test scenario of the CTBTO 2014 Integrated Field Exercise, the intrinsic relationship between particulate and noble gas signatures has been examined. Here this study shows that, depending upon the time of the radioxenon release, the particulate progeny can produce the more detectable signature. Thus, as both particulate and noble gas signatures are inherently coupled, the authors recommend that the sample categorization schemes should be linked.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A stilbene - CdZnTe based radioxenon detection system

Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Technical Issues in the Comprehensive Nuclear Test Ban Treaty (CTBT) Ratification Debate: A 20 Year Retrospective

Two decades after the U.S. Senate declined in 1999 to give its consent to ratification of the Comprehensive Nuclear Test Ban Treaty (CTBT), the treaty remains in legal and political limbo. Legally, the treaty cannot enter into force without U.S. ratification. However, the Senate’s rejection does not strip the treaty of its force as an element of customary international law or alter the will of other signatories to see it enter into force. Politically, the debate over the virtues and flaws of the treaty remains as strong as ever, with some CTBT advocates pushing energetically for U.S. re-review while some opponents seek ways to “un-sign” the treaty. Meanwhile, despite the Senate’s rejection of the treaty, the United States acts in a manner consistent with its main obligations by maintaining a moratorium on explosive nuclear testing and providing financial support (as well as technical expertise) to the CTBT Organization (CTBTO)—in particular the CTBTO’s International Monitoring System (IMS). The CTBT may well remain in such limbo for a long time to come, unless some catalytic event comes along to re-shape national perceptions and priorities, one way or the other. The treaty’s future, whatever it might be, will be determined in part by how much perspectives might have changed in light of interim developments. Our purpose is to shed light on some of those developments and to assess their relevance. The 1999 ratification debate addressed a large number of issues. Rejection was driven by various policy and technical judgments. The purpose of this paper is to re-examine those technical judgments in light of what has been learned over the following two decades. On some technical matters, there was explicit recognition of extant uncertainties, as well as a conviction and hope that time would dispel them. To be doubly clear, our purpose is not to recommend a way forward on CTBT ratification. The policy judgments of 1999 and 2020 are beyond the scope of this paper. This technical re-examination proceeds as follows. It begins with a short background section to introduce the key technical matters in discussion in the U.S. ratification process. Then it moves systematically through each of those topics with a review of relevant background information, a discussion of key points in debate, an analysis of subsequent experience, and a current assessment. The historical analysis draws on many sources including the primary documents of the Congressional debate, the official article-by-article interpretation by the Department of State, and the statements of key players in the process. We also relied on key technical reports and publications by subject matter experts that have addressed in more detail many of the issues in our focus. These sources include the 2002 and 2012 reports of the National Academy of Sciences as well as publications by senior technical staff of Lawrence Livermore National Laboratory (LLNL) who were actively involved in the ratification debate, including then-Laboratory Director Bruce Tarter. We also conducted several interviews with government officials from the 1990s, past laboratory directors, and other members of the scientific community. But, except where individuals are specifically cited by name, the judgments offered here are our own and should not be attributed to any other individual or to LLNL as such.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Summary of NDC Capacity Building Workshop and Regional Seismic Travel Time (RSTT) in combination with Data Sharing and Integration Training

The NNSA Seismic Cooperation Program (SCP) sponsored Stephen Myers (LLNL), Michael Begnaud (LANL), Brian Young (SNL) and Istvan Bondar (Research Center for Astronomy and Earth Sciences, Hungary) to serve as a presenters/trainers at the “NDC Capacity Building Workshop and Regional Seismic Travel Time (RSTT) in combination with Data Sharing and Integration Training” September 4-8 2022 in Muscat, Oman (See Appendix A for the agenda). The workshop and training (workshop from here forward) was organized by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS). The first half of the week was devoted to NDC workshop activities, and the second half was devoted to RSTT training. Fifty-five participants from 27 countries and the CTBTO-PTS attended the 5-day workshop (See Appendix B for list of participants and countries of origin). Presentations from the PTS described the International Monitoring System (IMS), International Data Centre (IDC) products, and metrics of regional data utilization. Contributed presentations from each country’s scientists included descriptions of regional and national networks, methods of data analysis, and needs for material and technical assistance. Training included an overview of the RSTT method and instruction on how to locate seismic events with the iLoc program, which utilizes RSTT travel times to reduce bias in event location estimates. Methods of seismic tomography and the need for a high-quality tomographic set, including seismological “ground truth”, were emphasized. Seismological “ground truth” or “GT” is a term that has come to mean both events with known location and events with well-characterized locations that are estimated using seismological data, typically with epicenter accuracy of 5 km or better. Notably, the instructional platform has migrated from UNIX shell scripts to Jupyter Notebooks. Jupyter Notebooks have the advantage being more visually intuitive, including display of graphics within the notebook. Each notebook includes every processing step that participants need to reproduce the entire exercise.

58 GEOSCIENCES↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDC Re-Engineering Phase 2 System Specification Document Version 1.5

This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Re-Engineering Phase 2 project. This System Specification Document (SSD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but does include requirements for the dissemination of radionuclide data and products.

97 MATHEMATICS AND COMPUTING↗

IDC Re-Engineering Phase 2 System Requirements Document Version 1.4

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data, but includes requirements for the dissemination of radionuclide data and products.

97 MATHEMATICS AND COMPUTING↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining the potential for detecting simultaneous noble gas and aerosol samples in the international monitoring system radionuclide network

The purpose of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) is to establish a legally binding ban on nuclear weapon test explosions or any other nuclear explosions. The Preparatory Commission for the CTBT Organization (CTBTO PrepCom) is developing the International Monitoring System (IMS) that includes a global network of 80 stations to monitor for airborne radionuclides upon entry into force of the CTBT. All 80 radionuclide stations will monitor for particulate radionuclides and at least half of the stations will monitor for radioxenon. The airborne radionuclide monitoring is an important verification technology both for the detection of a radionuclide release and in the determination of whether the release event originates from a nuclear explosion as opposed to an industrial use of nuclear materials. Nuclear power plants and many medical isotope production facilities release radioxenon into the atmosphere. Low levels of a few particulate isotopes, such as iodine, may also be released. Detections of multiple isotopes are useful for screening the radionuclide samples for relevance to the Treaty. This paper examines the anticipated joint detections in the IMS of noble gas and particulate isotopes from underground nuclear explosions where breaches in the underground containment vents from low levels to up to 1% of the radionuclide inventory of the resulting fission products to the atmosphere. Detection probabilities are based on 844 simulated release events spaced out at 17 release locations and one year in time. Six different release (venting) scenarios, including two fractionated scenarios, were analyzed. When ranked by detection probability, 11 particulate isotopes and one noble gas isotope ( 133 Xe) appear in the top 20 isotopes for all six release scenarios. Using the 11 particulate isotopes and the one noble gas isotope, the IMS has nearly the same detection probability as when 45 particulate and 4 noble gas isotopes are used. Thus, a limited list of relevant radionuclides may be sufficient for treaty verification purposes. The probability that at least one particulate and at least one radioxenon isotope would be detected in the IMS from the release events ranged from 0.15 to 0.86 depending on the release scenario.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A prototype detection system for atmospheric monitoring of xenon radioisotopes

The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.

36 MATERIALS SCIENCE↗

Applying Waveform Correlation to Reduce Seismic Analyst Workload Due to Repeating Mining Blasts

Agencies that monitor for underground nuclear tests are interested in techniques that automatically characterize mining blasts to reduce the human analyst effort required to produce high–quality event bulletins. Waveform correlation is effective in finding similar waveforms from repeating seismic events, including mining blasts. We report the results of an experiment to detect and identify mining blasts for two regions, Wyoming (U.S.A.) and Scandinavia, using waveform templates recorded by multiple International Monitoring System stations of the Preparatory Commission for the Comprehensive Nuclear–Test–Ban Treaty Organization (CTBTO PrepCom) for up to 10 yr prior to the time of interest. We discuss approaches for template selection, threshold setting, and event detection that are specialized for characterizing mining blasts using a sparse, global network. We apply the approaches to one week of data for each of the two regions to evaluate the potential for establishing a set of standards for waveform correlation processing of mining blasts that can be generally applied to operational monitoring systems with a sparse network. Here, we compare candidate events detected with our processing methods to the Reviewed Event Bulletin of the International Data Centre to assess potential reduction in analyst workload.

58 GEOSCIENCES↗

Preface to the Focus Section on North Korea’s September 2017 Nuclear Test and Its Aftermath

On September 3, 2017 a large seismic event was detected near the Punggye-ri nuclear test site in North Korea (officially known as the Democratic People Republic of Korea or DPRK) by several geophysical monitoring institutions (for example, the USGS announced it as mb 6.3 event, the CTBTO announced it as a mb 6.1 event). Within a few hours North Korea declared it had carried out its sixth underground nuclear explosion, a test of a hydrogen bomb.

58 GEOSCIENCES↗

CEA SMAD 2016 Digitizer Evaluation.

Sandia National Laboratories has tested and evaluated an updated SMAD digitizer, developed by the French Alternative Energies and Atomic Energy Commission (CEA). The SMAD digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMAD digitizers have been updated since their last evaluation by Sandia to improve their performance when recording at a sample rate of 20 Hz for infrasound applications and 100 Hz for hydro-acoustic seismic stations. This evaluation focuses primarily on the 20 Hz and 100 Hz sample rates. The SMAD digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Two Guralp Preamplifiers for GS13 Seismometer Application.

Sandia National Laboratories has tested and evaluated a new preamplifier, the Guralp Preamplifier for GS13, manufactured by Guralp. These preamplifiers are used to interface between Guralp digitizers and Geotech GS13 Seismometers. The purpose of the preamplifier evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Guralp GS13 Preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗