Search NASA⌕ Search

SEARCH · Search NASA

Results for “CTC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of substrates and phosphate on INT (2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl tetrazolium chloride) and CTC (5-cyano-2,3-ditolyl tetrazolium chloride) reduction in Escherichia coli

The effects of substrates of primary aerobic dehydrogenases, and inorganic phosphate on aerobic INT and CTC reduction in Escherichia coli were examined. In general, INT produced less formazan than CTC, but INT (+) cell counts remained near values of CTC (+) cells. INT and CTC (+) cell numbers were higher than plate counts on R2A medium using succinate, formate, lactate, casamino acids, glucose, glycerol (INT only) and no substrate. Formate resulted in the greatest amount of INT and CTC formazan. Reduction of both INT and CTC was inhibited above 10 mmol l-1 phosphate, and this appeared to be related to decreased rates of O2 consumption. Formation of fluorescent CTC (+), but not INT (+) cells was also inhibited in a concentration dependent manner by phosphate above 10 mmol l-1. From light microscopic observations it appeared CTC formed increasing amounts of poorly or non-fluorescent formazan with increasing phosphate. Therefore, use of phosphate buffer in excess of 10 mmol l-1 may not be appropriate in CTC and INT reduction assays.

NASA Program Environmental Health↗

A Historical Perspective on Primary and Possible Secondary Sources of Atmospheric Carbon Tetrachloride

Atmospheric sources of Carbon Tetrachloride (CTC) have been controversial since its detection in the early 1970. Initial proposals were that it is globally uniformly distributed and its lack of current emissions and inferred lifetime indicated that it was likely of natural origin. Historical analysis of CTC use and emissions showed that atmospheric CTC was long-lived and mainly of man-made origin although small natural sources and sinks (e. g. oceans) could not be ruled out. This deduction was hard because a majority of emissions had occurred in early part of the 20th century when CTC was commonly used as a fumigant, a solvent, and a raw material for the manufacture of many chemicals. In the 1940's adverse health effects of exposure to CTC became evident and its emissions were greatly curtailed and substituted with C2Cl4 which was thought to be much safer. There were smog chamber studies that showed that C2Cl4, a widely used solvent during the late 20th century, could produce CTC with up to a 7% yield. Subsequently it was discovered that this chemistry probably required Cl atoms and since Cl atoms were not abundant in the atmosphere actual yields based on OH oxidation were probably closer to 0.1%. CTC was subsequently banned by the Montreal Protocol to prevent stratospheric ozone depletion and its preferred substitute C2Cl4 was also banned by EPA for reasons of potential carcinogenicity and toxicity. CTC since has been measured in many airborne NASA campaigns in which plumes have been sampled from a variety of regions which may still be emitting CTC. I will briefly discuss this historical perspective of CTC and show some recent data that may shed light on its current sources or lack there off.

atmosphere↗

NASA Northeast Regional Technology Transfer Center

This report is a summary of the primary activities and metrics for the NASA Northeast Regional Technology Transfer Center, operated by the Center for Technology Commercialization, Inc. (CTC). This report covers the contract period January 1, 2000 - March 31, 2001. This report includes a summary of the overall CTC Metrics, a summary of the Major Outreach Events, an overview of the NASA Business Outreach Program, a summary of the Activities and Results of the Technology into the Zone program, and a Summary of the Major Activities and Initiatives performed by CTC in supporting this contract. Between January 1, 2000 and March 31, 2001, CTC has facilitated 10 license agreements, established 35 partnerships, provided assistance 517 times to companies, and performed 593 outreach activities including participation in 57 outreach events. CTC also assisted Goddard in executing a successful 'Technology into the Zone' program.' CTC is pleased to have performed this contract, and looks forward to continue providing their specialized services in support of the new 5 year RTTC Contract for the Northeast region.

Dunn, James P.↗

Sensitive detection of Escherichia coli O157:H7 in food and water by immunomagnetic separation and solid-phase laser cytometry

Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.

Non-NASA Center↗

Improving Rain/No-Rain Detection Skill by Merging Precipitation Estimates from Different Sources

Rain/no-rain detection error is a key source of uncertainty in regional and global precipitation products that propagates into offline hydrological and land surface modeling simulations. Such detection error is difficult to evaluate and/or filter without access to high-quality reference precipitation datasets. For cases where such access is not available, this study proposes a novel approach for improved rain/no-rain detection. Based on categorical triple collocation (CTC) and a probabilistic framework, a weighted merging algorithm (CTC-M) is developed to combine noisy, but independent, precipitation products into an optimal binary rain/no-rain time series. Compared with commonly used approaches that directly apply the best parent product for rain/no-rain detection, the superiority of CTC-M is demonstrated analytically and numerically using spatially dense precipitation measurements over Europe. Our analysis also suggests that CTC-M is tolerant to a range of cross-correlated rain/no-rain detection errors and detection biases of the parent products. As a result, CTC-M will benefit global precipitation estimation by improving the representation of precipitation occurrence in gauge-based and multisource merged precipitation products.

Jianzhi Dong↗

Evaluation of Instability Phenomena in Sands: Plane Strain Versus Triaxial Conditions

Extensive research was carried out in the 1950s on theories of plasticity to extend the concepts developed for metals to materials that failed according to the Mohr-Coulomb criterion. The new ideas made it possible to merge the two distinct concepts (strength and deformation techniques) into one that relies on better understanding of plasticity and resulted in a rapid growth in the field of constitutive modeling of soil behavior. At the same time advanced experimental apparatuses and laboratory procedures were developed to calibrate the models. However, most laboratory experiments on granular materials are performed under Conventional Triaxial Conditions (CTC) for the purposes of evaluating constitutive behavior and stability properties, whereas most geotechnical field problems are closer to the Plane Strain (PS) condition. The triaxial tests performed in most laboratories comprise a simplification over in situ states and allow easier and robust experimentation. Most landslide problems, failure of soils beneath shallow and deep foundations, and failure of retaining structures, are cases that can generally be considered as plane strain. Strength and deformation characteristics of granular materials loaded in plane strain may be considerably different from those observed in CTC. Most studies on sands were limited to evaluating the constitutive behavior and in some cases extended to briefly describing the associated instability phenomena. This paper presents the results of a series of PS and CTC experiments performed on fine uniform silica sand known as F-75 Ottawa sand. Advanced analysis techniques were used to study the instability phenomena, which yielded very accurate measurements of shear bands occurrences and patterns. Destructive thin-sectioning technique along with monitoring the specimen surface deformation was used in the PS experiments and Computed Tomography (CT) was used to investigate the progress of primary and secondary shear bands in specimens subjected to CTC. Comparison between the two cases will be presented and discussed.

Alshibli, Khalid A.↗

Rapid in situ assessment of physiological activities in bacterial biofilms using fluorescent probes

Two rapid in situ enumeration methods using fluorescent probes were used to assess the physiological activities of Klebsiella pneumoniae biofilms on stainless steel. Fluorescent dyes, 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and rhodamine 123 (Rh 123), were chosen to perform this study. CTC is a soluble redox indicator which can be reduced by respiring bacteria to fluorescent CTC-formazan crystals. Rh 123 is incorporated into bacteria with respect to cellular proton motive force. The intracellular accumulation of these fluorescent dyes can be determined using epifluorescence microscopy. The results obtained with these two fluorescent probes in situ were compared to the plate count (PC) and in situ direct viable count (DVC) methods. Viable cell densities within biofilms determined by the three in situ methods were comparable and always showed approximately 2-fold higher values than those obtained with the PC method. As an additional advantage, the results were observed after 2 h, which was shorter than the 4 h incubation time required for the DVC method and 24 h for colony formation. The results indicate that staining with CTC and Rh 123 provides rapid information regarding cell numbers and physiological activities of bacteria within biofilms.

NASA Discipline Number 04-10↗

Experimental Observations of Localization Phenomena in Sands: Plane Strain Versus Triaxial Compression Conditions

A comprehensive experimental investigation was conducted to investigate the effects of loading condition and confining pressure on strength properties and instability phenomena in sands. A uniform sub-rounded to rounded natural silica sand known as F-75 Ottawa sand was used in the investigation. The results of a series on Conventional Triaxial Compression (CTC) experiments tested under very low confining pressures (0.05 - 1.30) kPa tested in a Microgravity environment abroad the NASA Space Shuttle are presented in addition to the results similar specimens tested in terrestrial laboratory to investigate the effect of confining pressure on the constitutive behavior of sands. The behavior of the CTC experiments is compared with the results of Plane Strain (PS) experiments. Computed tomography and other digital imaging techniques were used to study the development and evolution of shear bands.

Alshibli, Khalid A.↗

Soil moisture detection by Skylab's microwave sensors

The author has identified the following significant results. Terrain microwave backscatter and emission response to soil moisture variations were investigated using Skylab's 13.9 GHz RADSCAT (radiometer/scatterometer) system. Data acquired on June 5, 1973, over a test site in west-central Texas indicated a fair degree of correlation with composite rainfall. The scan made was cross-track contiguous (CTC) with a pitch of 29.4 deg and no roll effect. Vertical polarization was employed with both radiometer and scatterometer. The composite rainfall was computed according to the flood prediction technique using rainfall data supplied by weather reporting stations.

Moore, R. K.↗

Soil moisture detection by Skylab's microwave sensors

Terrain microwave backscatter and emission response to soil moisture variations are investigated using Skylab's 13.9 GHz RADSCAT (Radiometer-Scatterometer) system. Data acquired on June 5, 1973 over a test site in west-central Texas indicates a fair degree of correlation with composite rainfall. The scan mode was cross-track contiguous (CTC) with a pitch of 29.4 deg and no roll offset. Vertical polarization was employed with both radiometer and scatterometer. The composite rainfall was computed according to the flood prediction technique using rainfall data supplied by weather reporting stations.

Ulaby, F. T.↗

Diurnal effect in cosmic rays at middle latitudes according to stratospheric measurements

Results of measurements of the diurnal wave of the cosmic ray (CR) intensity in stratosphere at the latitude with the geomagnetic cutoff rigidity R sub c = 7.6 GV are presented. Measurements of diurnal variation of the CR intensity were carried by means of radiosondes: by a detector composed of a gas discharge counter CTC-6 and a telescope containing two counters with a 7 mm aluminum filter between them.

Asatryan, G. A.↗

Theoretical studies on the mechanical behavior of granular materials under very low intergranular stresses

The salient aspects of the theoretical modeling of a conventional triaxial test (CTC) of a cohesionless granular medium with stress and strain rate loading are described. Included are a controllable gravitational body force and provision for low confining pressure and/or very low intergranular stress. The modeling includes rational, analytic, and numerical phases, all in various stages of development. The numerical evolutions of theoretical models will be used in final design stages and in the analysis of the experimental data. In this the experimental design stage, it is of special interest to include in the candidate considerations every anomaly found in preliminary terrestrial experimentation. Most of the anomalies will be eliminated by design or enhanced for measurement as the project progresses. The main aspect of design being not the physical apparatus but the type and trajectories of loading elected. The major considerations that have been treated are: appearance and growth of local surface aberrations, stress-power coefficients, strain types, optical strain, radial bead migration, and measures of rotation for the proper stress flux.

French, Kenneth W., Jr.↗

An Earth Orbiting Satellite Service and Repair Facility

A conceptual design was produced for the Geosynchronous Satellite Servicing Platform (GSSP), an orbital facility capable of repairing and servicing satellites in geosynchronous orbit. The GSSP is a man-tended platform, which consists of a habitation module, operations module, service bay and truss assembly. This design review includes an analysis of life support systems, thermal and power requirements, robotic and automated systems, control methods and navigation, and communications systems. The GSSP will utilize existing technology available at the time of construction, focusing mainly on modifying and integrating existing systems. The entire facility, along with two satellite retrieval vehicles (SRV), will be placed in geosynchronous orbit by the Advanced Launch System. The SRV will be used to ferry satellites to and from the GSSP. Technicians will be transferred from Earth to the GSSP and back in an Apollo-derived Crew Transfer Capsule (CTC). These missions will use advanced telerobotic equipment to inspect and service satellites. Four of these missions are tentatively scheduled per year. At this rate, the GSSP will service over 650 satelites during the projected 25 year lifespan.

Berndt, Andrew↗

Rapid Bacterial Testing for Spacecraft Water

Evaluations of the fluorogenic stains and probes will continue. E. coli 0157:H7 will be used as the reference strain for optimizing protocols. We anticipate the continued use of the fluorescent antibodies (TRITC and FITC labeled) in conjunction with CTC, Rhl23, DiBAC4(3), DAPI and acridine orange. Chemunex, the manufacturer of the ChemScan analyzer system, also makes a fluorogenic probe, Chemchrome B, which will be incorporated into the suite of probes to evaluate once their system is on site. Regardless of the combination of stains and probes all will be evaluated on membrane filters. Development of a FISH protocol that will be applicable to our conditions will be continued. Complimentary 16s rRNA probes to Ps. aeruginosa and currently in our laboratory will be evaluated first. Once this protocol has been adequately optimized other probes will be ordered for u a select number of other species. Currently, protocols to evaluate the effects of disinfection and the resulting lethality, injury on stain and/or probe specificity and reliability are being developed. E. coli 0157:H7 is the reference strain and chlorine the disinfectant the reference protocol is being developed around. Upon completion of this work, the resulting protocol will be extended to other species and disinfectants (e.g., iodine). Similar disinfectant experiments will then be conducted on the same species after starvation to evaluate the effects of starvation on disinfection resistance and the applicability of the stains and probes. Development of the immunomagnetic separation system will continue. Combined with the rapid methods described above, with enumeration by the ChemScan, we anticipate that this will provide a highly sensitive technique for the detection of specific, active bacteria.

Lisle, John T.↗

Fluid/Solid Boundary Conditions in Non-Isothermal Systems

The existing theoretical research concerned with thermal creep at fluid/solid interfaces is briefly reviewed, and the importance of microgravity-based experimental data is then discussed. It is noted that the ultimate goal of this research is a rational molecular level theory that predicts the dependence of a dimensionless thermal creep coefficient, Ctc, on relevant dimensionless parameters describing the way fluid molecules interact with the solid surface and how they interact among themselves. The discussion covers thermophoresis of isolated solid spheres and aggregates in gases; solid sphere thermophoresis in liquids and dense vapors; thermophoresis of small immiscible liquid droplets; and applications of the direct simulation Monte Carlo method.

Rosner, Daniel E.↗

Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.

Review, Tutorial↗

The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7

A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.

NASA Discipline Environmental Health↗

Core Technical Capability Laboratory Management System

The Core Technical Capability Lab - oratory Management System (CTCLMS) consists of dynamically generated Web pages used to access a database containing detailed CTC lab data with the software hosted on a server that allows users to have remote access.

Shaykhian, Linda↗