Search NASA⌕ Search

SEARCH · Search NASA

Results for “CTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Correcting STIS CCD Point-Source Spectra for CTE Loss

We review the on-orbit spectroscopic observations that are being used to characterize the Charge Transfer Efficiency (CTE) of the STIS CCD in spectroscopic mode. We parameterize the CTE-related loss for spectrophotometry of point sources in terms of dependencies on the brightness of the source, the background level, the signal in the PSF outside the standard extraction box, and the time of observation. Primary constraints on our correction algorithm are provided by measurements of the CTE loss rates for simulated spectra (images of a tungsten lamp taken through slits oriented along the dispersion axis) combined with estimates of CTE losses for actual spectra of spectrophotometric standard stars in the first order CCD modes. For point-source spectra at the standard reference position at the CCD center, CTE losses as large as 30% are corrected to within approx.1% RMS after application of the algorithm presented here, rendering the Poisson noise associated with the source detection itself to be the dominant contributor to the total flux calibration uncertainty.

Goudfrooij, Paul↗

Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs

Tubes made from biaxially oriented liquid-crystal polymers (LCPs) have been developed for use as penetrations on cryogenic tanks. ( Penetrations in this context denotes feed lines, vent lines, and sensor tubes, all of which contribute to the undesired conduction of heat into the tanks.) In comparison with corresponding prior cryogenic-tank penetrations made from stainless steels and nickel alloys, the LCP penetrations offer advantages of less weight and less thermal conduction. An additional major advantage of LCP components is that one can tailor their coefficients of thermal expansion (CTEs). The estimated cost of continuous production of LCP tubes of typical sizes is about $1.27/ft ($4.17/m) [based on 1998 prices]. LCP tubes that are compatible with liquid oxygen and that feature tailored biaxial molecular orientation and quasi-isotropic properties (including quasi-isotropic CTE) have been fabricated by a combination of proprietary and patented techniques that involve the use of counterrotating dies (CRDs). Tailoring of the angle of molecular orientation is what makes it possible to tailor the CTE over a wide range to match the CTEs of adjacent penetrations of other tank components; this, in turn, makes it possible to minimize differential-thermal expansion stresses that arise during thermal cycling. The fabrication of biaxially oriented LCP tubes by use of CRDs is not new in itself. The novelty of the present development lies in tailoring the orientations and thus the CTEs and other mechanical properties of the LCPs for the intended cryogenic applications and in modifications of the CRDs for this purpose. The LCP tubes and the 304-stainless-steel tubes that the LCP tubes were intended to supplant were tested with respect to burst strength, permeability, thermal conductivity, and CTE.

Rubin, Leslie↗

CTE Measurements of Carbon Fibers in ESEM

The strong appeal of carbon fiber reinforced ceramic matrix and carbon-carbon composites arises from their promising high temperature performance within laboratory-simulated nozzle, leading edge and combustor environments. The main drawback in these systems are two fold; namely oxidation affinity and CTE mismatch. To date the emphasis has been on axial CTE mismatch with the push on estimating (component) laminate level data. However, in heterogeneous and anisotropic systems, all failure mechanisms are at micro or nano scales. This paper will report plans and progress on single carbon fibers efforts in order to develop its temperature dependent, anisotropic thermophysical and thermomechanical properties using combination of x-ray spectroscopy and environmental scanning electron microscopy to capture circumferential expansion from 20-900 C in within the SEM chamber. Surface roughness measurements were also determined. Crystallinity was also determined by the quality of the electron diffraction (ED) patterns.

Effinger, Michael↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant K.↗

Si-based CTE-matched substrate for laser diode packaging

A Cu—Si—Cu substrate having a silicon substrate, copper plating on opposite sides of the silicon substrate, and copper vias extending thru the silicon substrate to electrically and thermally connect the copper platings together. The thicknesses of the silicon substrate and the copper platings are selected so that a coefficient of thermal expansion (CTE) of the Cu—Si—Cu substrate is substantially the same as a CTE of a material to be mounted on the Cu—Si—Cu substrate.

Patra, Susant↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant↗

Composite Technology for Exploration (CTE) Briefing to RUAG

Technology Product Capability: The CTE project will develop and demonstrate critical composites technologies with a focus on weight-saving, performance-enhancing bonded joint technology for Space Launch System (SLS)-scale composite hardware to support future NASA exploration missions. (a) Improve the analytical capabilities required to predict failure modes in composite structures. (b) Support SLS payload adapters and fittings by maturing composite bonded joint technology and analytical tools to enable risk reduction.

manufacturing technology↗

Composite Technology for Exploration (CTE)

Technology Product Capability: The CTE (Composite Technology for Exploration) project will develop and demonstrate critical composites technologies with a focus on weight-saving, performance-enhancing bonded joint technology for Space Launch System (SLS)-scale composite hardware to support future NASA exploration missions - Improve the analytical capabilities required to predict failure modes in composite structures; - and, Support SLS payload adapters and fittings by maturing composite bonded joint technology and analytical tools to enable risk reduction. Exploration & Science Impact: Lighter weight structures; Improved material predictive capabilities; Improved bonded joint failure load and mode predictions to help reduce knockdown factors; and improve predictability and reliability; Increase confidence of all bonded joint composite structures; Reduce reliance on expensive testing.

CTE↗

CTE Measurements for Loading Scenarios

The goals are to 1. understand full field thermal expansion of system parts by using strain gauges, DIC, and possibly ESPI. This is ultimately used to update a Finite Element Model relating to stockpile stewardship. 2. To verify the resolution of digital image correlation methods for thermal expansion measurements (CTE). A few conclusions: To this point, the DIC data shows more noise (less resolution) than we would like and Strain Gauge data is sound but it is more localized than full field.

42 ENGINEERING↗

ASTP video tape recorder ground support equipment, addendum 1 (CTE splitter/buffer). Operations manual

A descriptive handbook for the CTE splitter (RCA part No. 8673734-503) was presented. This unit is designed to extract time data from an interleaved video audio signal. It is a rack mounting unit 7 inches high, 19 inches wide, 20 inches deep, mounted on slides for retracting from the rack, and weighs approximately 40 pounds. The following information is provided: installation, operation, principles of operation, maintenance, schematics and parts lists.

Source record↗

ASTP video tape recorder ground support equipment, addendum 2 (CTE splitter/buffer). Operations manual

A descriptive handbook for the CTE splitter (RCA part No. 8673734-50A) was presented. This unit is designed to extract time data from an interleaved video/audio signal. It is a rack mounting unit 7 inches high, 19 inches wide, 20 inches deep, mounted on slides for retracting from the rack, and weighs approximately 40 pounds. The following information is provided: installation, operation, principles of operation, maintenance, schematics and parts lists.

Source record↗

Structural design and analysis for an ultra low CTE optical bench for the Hubble Space Telescope corrective optics

The stringent stability requirements of the Corrective Optics Space Telescope Axial Replacement (COSTAR) necessitates a Deployable Optical Bench (DOB) with both a low CTE and high resonant frequency. The DOB design consists of a monocoque thin shell structure which marries metallic machined parts with graphite epoxy formed structure. Structural analysis of the DOB has been integrated into the laminate design and optimization process. Also, the structural analytical results are compared with vibration and thermal test data to assess the reliability of the analysis.

Neam, Douglas C.↗

Strain Gauges Indicate Differential-CTE-Induced Failures

A method of detecting mechanical failure induced by variation in temperature at an adhesive bond between two materials that have different coefficients of thermal expansion (CTEs) involves monitoring of strain-gauge readings. This method can be regarded as an exploitation of the prior observation that the readings of strain gauges commonly used in tensile and compressive testing of material specimens include features indicative of incremental failures in the specimens. In this method, one or more strain gauges are bonded to either or both of the two materials near the bond between the materials. (The adhesive used to bond the strain gauges would not ordinarily be the same as the one used to bond the two materials). Then strain-gauge readings are recorded as the temperature of the materials is varied through a range of interest. Any significant discontinuity in the slope of the resulting strain-versus-temperature curve(s) is taken to be a qualitative indication of a failure of the bond between the two materials and/or a failure within one of the materials in the vicinity of the bond. The method has been demonstrated in experiments on specimens consisting of polyacrylonitrile-fiber/epoxy-matrix laminated composite plates bonded by epoxy to smaller plates made, variously, of aluminum, titanium, and a low-CTE nickel/iron alloy. In preparation for each experiment, strain gauges were bonded, by use of cryogenic-rated adhesives, to the composite plate near the corners of the metal plate (see Figure 1). In each experiment, strain-gauge and temperature readings were taken as the specimen was cooled from room temperature to 20 K. The specimens were then returned to room temperature and ultrasonically inspected for damage in the bond region. No failure events were detectable in the strain-gauge readings from the composite/ titanium and composite/low-thermalexpansion- alloy specimens, and ultrasonic inspection of these specimens revealed no damage. However, failure events were seen in the strain-gauge readings from the composite/aluminum specimens (see Figure 2), and ultrasonic inspection confirmed that there was damage in the bond regions of these specimens.

Harris, Brian↗

Composite Technology for Exploration (CTE)

The CTE project is developing and demonstrating weight-saving, performance-enhancing composite bonded joint technology by incorporating materials characterization studies into the design, manufacturing, and testing of lightweight composite bonded joint concepts for SLS-scale applications. The project is advancing current high-fidelity analysis tools and standards for improvements in the prediction of failure and residual strength of bonded joints.

Composite Technology↗

Instrument for Measuring Cryo CTE

Coefficient of thermal expansion is an integral part of the performance of optical systems, especially for those, which operate at cryogenic temperatures. The measurement of the coefficient of relevant materials has been of continuous interest. Besides commercial measurement sources, development of one-of-a-kind tools have always been of interest due to local needs. This paper describes one such development at the University of Alabama in Huntsville (UAH). The approach involves two vertical rods (one sample and one reference) on a flat platform. A probe bar is held horizontally atop the two samples. A temperature change will generally cause rotation of the probe bar. A mirrored surface on one end of the probe bar is used to measure the rotation using the reflection of an incident laser beam upon it. A position-sensing detector measures the change of the reflected beam spot position. Using other known quantities, the change determines the coefficient of thermal expansion of the sample material as a function of temperature. A parallel measurement of the rotation of the sample support platform is also performed to account for any unwanted background effects. This system has been demonstrated in a cryogenic chamber at the NASA Marshall Space Flight Center X-ray Calibration Facility (XRCF). We present the system details, achievable sensitivity, and up-to-date experimental performance.

Vikram, Chandra S.↗

Thermophysical ESEM and TEM Characterization of Carbon Fibers CTE, Spectroscopy and Roughness Studies at High Temperatures

Accurate determination of the transverse properties of carbon fibers is important for assessment and prediction of local material as well as global structural response of composite components. However the measurements are extremely difficult due to the very small diameters of the fibers (few microns only) and must be conducted within a microscope. In this work, environmental scanning electron microscope (ESEM) and transmission electron microscope (TEM) are used to determine the transverse coefficient of thermal expansion of different carbon fibers as a function of temperature.

Ochoa, Ozden O.↗