Search NASA⌕ Search

SEARCH · Search NASA

Results for “CTFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Quantifying CTFE content in FK-800 using ATR-FTIR and time to peak crystallization

The chlorotrifluoroethylene (CTFE) content in vinylidene fluoride (VDF)-CTFE copolymers greatly influences the chemical and physical properties and ultimately determines the application. The copolymer known as FK-800 has a VDF:CTFE ratio of ~1:3 and is used almost exclusively as the binder in the insensitive high explosive (HE) formulation PBX 9502. Due to the dangerous nature of HE work and the effect CTFE content variations have, the ability to quickly and easily quantify CTFE content is of interest. Two techniques, attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and time to peak crystallization measured by heat flow calorimetry, were evaluated here as potential means for quantifying CTFE content. Based on the certificate of analyses (COAs), FK-800 lots with varied CTFE content encompassing the range historically used in HE applications were used as standards for both methodologies. For FTIR, a linear regression was performed on the peak area of the C-Cl IR stretch and the CTFE content; the methodology was then demonstrated on four samples, two lots of unadulterated material and material recovered from two HE samples. The calculated CTFE content and COAs were in good agreement for all four samples. Heat flow calorimetry revealed the relationship between time to peak crystallization and CTFE content was best fit by a power regression; the methodology was then tested on two different FK-800 lots. Only one sample showed good agreement between the calculated CTFE content and the COA. This discrepancy indicates the method developed is not suitable for quantifying CTFE, but provides valuable insight regarding the crystallization behavior of VDF-CTFE copolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of The Dimensional Stability of Kel-F 81 and Neoflon CTFE M400H Polychlorotrifluoroethylenes Used in Valve Seat Application

The dimensional stability of polychlorotrifluoroethylene (PCTFE) valve seats used in oxygen regulator applications was determined by thermomechanical analysis (TMA). Two traceable grades of PCTFE were tested; Kel-F 81 and Neoflon CTFE M400H. For these particular resins, the effect of percent crystallinity, zero strength time (ZST) molecular weight, resin grade, process history (compression-molded versus extruded) on the dimensional stability and annealing behavior was determined. In addition to the traceable Kel-F 81 and Neoflon CTFE M400H grades, actual PCI'PH valve seats of differing geometry and design were tested by TMA. The PCTFE valve seats were of unspecified resin grade, although certain inferences about the grade could be drawn based on knowledge of the valve seat fabrication date. Results consistently revealed dimensional instability of varying magnitude at temperatures ranging from 40 to 70 degrees Celsius. Furthermore, some of the pre- 1 995 seats appeared to be more dimensionally stable than those fabricated after 1995. The TMA results are discussed in the context of several proposed ignition mechanisms; namely, particle impact, presence of contaminant oils and fibers, and localized heating by flow friction and/or resonance. The effect of metal constraint on the dimensional stability of PCTFE is also discussed. Finally, the effect of percent crystallinity, ZST molecular weight, resin grade, process history (compression-molded versus extruded) on the AIT, delta Hc and impact sensitivity of various types of Neoflon CTFE M400H was determined using Kel-F 81 as a control. Results show that the AIT, delta Hc and impact sensitivity were essentially independent of Neoflon CTFE process history and structure.

Waller, Jess M.↗

Preparation Process and Dielectric Properties of Ba(0.5)Sr(0.5)TiO3-P(VDF-CTFE) Nanocomposites

Ceramic-polymer 0-3 nanocomposites, in which nanosized Ba(0.5)Sr(0.5)TiO3 (BST) powders were used as ceramic filler and P(VDF-CTFE) 88/12 mol% [poly(vinylidene fluoridechlorotrifluoroethylene)] copolymer was used as matrix, were studied over a concentration range from 0 to 50 vol.% of BST powders. It is found that the solution cast composites are porous and a hot-press process can eliminate the porosity, which results in a dense composite film. Two different configurations used in the hot-press process are studied. Although there is no clear difference in the uniformity and microstructure of the composites prepared using these two configurations, the composite prepared using one configuration exhibit a higher dielectric constant with a lower loss. For the composite with 40 vol. BST, a dielectric constant of 70 with a loss of 0.07 at 1 kHz is obtained at room temperature. The composites exhibit a lower dielectric loss than the polymer matrix at high frequency. However, at low frequency, the composites exhibit a higher loss than the polymer matrix due to a low frequency relaxation process that appears in the composites. It is believed that this relaxation process is related to the interfacial layer formed between BST particle and the polymer matrix. The temperature dependence of the dielectric property of the composites was studied. It is found that the dielectric constant of these composites is almost independent of the temperature over a temperature range from 20 to 120 C. Key words: A. Polymer-matrix composites (PMCs); B. Electrical Properties; E. Casting; E. Heat treatment; Dielectric properties.

Zhang, Lin↗

Effect of Molding and Machining on Neoflon CTFE M400H Polychlorotrifluoroethylene Rod Stock and Valve Seat Properties

Since 1997 numerous fires have been reported to the Food and Drug Administration involving cylinder valves installed on medical use oxygen cylinders sold and operated within the United States. All of the cylinder valves in question had polychlorotrifluoroethylene (PCTFE) valve seats. Subsequent failure analysis showed that the main seat was the primary source of ignition. A review of the incidents involving cylinder valve fires indicated three possible ignition mechanisms: contaminant promotion, flow friction, and resonance. However, gas purity analysis showed that uncombusted, residual oxygen was within specification. Infrared and energy dispersive spectroscopy further showed that no contaminants or organic compounds were present in the remaining, uncombusted valve seat material or on seat plug surfaces. Therefore, contaminant-promoted ignition did not appear to be responsible for the failures. Observations of extruded material along the outer edge of the coined or loaded seat area produced by cylinder overuse or poppet overload led to concerns that accelerated gas flow across a deformed seat surface could generate enough localized heating to ignite the polymeric seat. Low molecular weight or highly amorphous quick-quenched PCTFE grades might be expected to be especially prone to this type of deformation. Such a failure mechanism has been described as flow friction; however, the corresponding mechanistic parameters are poorly understood. Subsequent revelation of low-temperature dimensional instability by thermomechanical analysis (TMA) in a variety of PCTFE sheet and rod stock samples led to new concerns that PCTFE valve seats could undergo excessive expansion or contraction during service. During expansion, additional extrusion and accompanying flow friction could occur. During contraction, a gap between the seal and adjacent metal surfaces could form. Gas flowing past the gap could, in turn, lead to resonance heating and subsequent ignition as described in ASTM Guide for Evaluation Nonmetallic Materials for Oxygen Service (G 63). Attempts to uncover the origins of the observed dimensional instability were hindered by uncertainties about resin grade, process history, and post-process heat history introduced by machining, annealing, and sample preparation. An approach was therefore taken to monitor property changes before and after processing and machining using a single, well-characterized lot of Neoflon CTFE.1 M400H resin. A task group consisting of the current PCTFE resin supplier, two molders, and four valve seat manufacturers was formed, and phased testing on raw resin, intermediate rod stock, and finished valve seats initiated. The effect of processing and machining on the properties of PCTFE rod stock and oxygen gas cylinder valve seats was then determined. Testing focused on two types of extruded rod stock and one type of compression-molded rod stock. To accommodate valve seat manufacturer preferences for certain rod stock diameters, two representative diameters were used (4.8 mm (0.1875 in.) and 19.1 mm (0.75 in.)). To encompass a variety of possible sealing configurations, seven different valve seat types with unique geometries or machining histories were tested. The properties investigated were dimensional stability as determined by TMA, specific gravity, differential scanning calorimetry (DSC), compressive strength, zero strength time, and intrinsic viscosity. Findings are discussed in the context of polymer structure-process-property relationships whenever possible.

Waller, Jess M.↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not presented for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens' sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not present for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens’ sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Giant Electrostriction via Nanodomain Engineering in Relaxor Ferroelectric Polymers

Relaxor ferroelectric (RFE) polymers hold great promise for artificial muscles due to their high actuation strain, high loading stress, and fast response. However, the structural origin underlying their large electrostrictive deformation remains elusive. In this study, we investigate poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)]-based RFE terpolymers, incorporating 1,1-chlorofluoroethylene (CFE) or chlorotrifluoroethylene (CTFE) (the terpolymers are denoted as terP-CFE and terP-CTFE, respectively) as termonomers. Although both terpolymers show similar semicrystalline morphology, drastically different electrostrictive properties are observed. Specifically, the terP-CFE annealed at 100 °C achieves a record-high transverse strain of ∼10.6%, whereas 100 °C-annealed terP-CTFE only shows a much lower actuation strain of ∼4.2% at the same poling field of 190 MV/m. To elucidate the origin of this difference, time-resolved wide-angle X-ray diffraction, small-angle X-ray scattering, and Fourier transform infrared experiments are performed during in situ electric poling. An RFE-to-ferroelectric (FE) crystal phase transition is observed for terP-CFE but is absent for terP-CTFE. Beyond the contribution of the crystalline phase, the oriented amorphous fraction and crystalline defects (e.g., taut-tie molecules) also play significant roles in enhancing electrostriction. In conclusion, this mechanistic insight provides a valuable foundation for the rational design of next-generation RFE polymers with tunable properties through defect engineering of their semicrystalline structures.

36 MATERIALS SCIENCE↗

Polymer-Oxygen Compatibility Testing: Effect of Oxygen Aging on Ignition and Combustion Properties

The oxygen compatibility of six polymers used in oxygen service was evaluated after exposure for 48 hours to oxygen pressures ranging from 350 to 6200 kPa (50 to 900 psia), and temperatures ranging from 50 to 250 C (122 to 302 F). Three elastomers were tested: CR rubber (C873-70), FKM fluorocarbon rubber (Viton A), and MPQ silicone rubber (MIL-ZZ-765, Class 2); and three thermoplastics were tested: polyhexamethylene adipamide (Zytel 42), polytetrafluoroethylene (Teflon TFE), and polychlorotrifluoroethylene (Neoflon CTFE M400H). Post-aging changes in mass, dimensions, tensile strength, elongation at break, and durometer hardness were determined. Also, the compression set was determined for the three elastomers. Results show that the properties under investigation were more sensitive to oxygen pressure at low to moderate temperatures, and more sensitive to temperature at low to moderate oxygen pressures. Inspection of the results also suggested that both chain scissioning and cross-linking processes were operative, consistent with heterogeneous oxidation. Attempts are underway to verify conclusively the occurrence of heterogeneous oxidation using a simple modulus profiling technique. Finally, the effect of aging at 620 kpa (90 psia) and 121 C (250 F) on ignition and combustion resistance was determined. As expected, aged polymers were less ignitable and combustible (had higher AlTs and lower heats of combustion). Special attention was given to Neoflon CTFE. More specifically, the effect of process history (compression versus extrusion molding) and percent crystallinity (quick- versus slow-quenched) on the AIT, heat of combustion, and impact sensitivity of Neoflon CTFE was investigated. Results show the AIT, heat of combustion, and impact sensitivity to be essentially independent of Neoflon CTFE process history and structure.

Waller, Jess M.↗

HALAR fluoropolymer: A versatile insulation material

Research directed toward developing materials for the wire and cable industry has resulted in a new product, E-CTFE copolymer, which has an outstanding combination of electrical, thermal, and mechanical properties. The properties of E-CTFE are discussed and compared with those of other commercial fluoropolymers. Particular attention is given to the utility of E-CTFE as a wire and cable insulation.

Robertson, A. B.↗

Origins of Electrostriction in Poly(vinylidene fluoride)-Based Ferroelectric Polymers

Although electrostriction is ubiquitous for dielectric polymers, giant electrostriction has not been observed until relaxor ferroelectric (RFE) poly(vinylidene fluoride) (PVDF)-based polymers are achieved. However, the exact origin for giant electrostriction in these polymers has not been fully understood. By studying the electrostriction in the uniaxially stretched films of a ferroelectric poly(VDF-co-trifluoroethylene) [P(VDF-TrFE)] random copolymer and an RFE poly(VDF-co-TrFE-co-chlorotrifluoroethylene) [P(VDF-TrFE-CTFE)] random terpolymer in this work, we confirmed that ferroelectric switching with large hysteresis, such as in the case of P(VDF-TrFE), was not genuine electrostriction. By decreasing large ferroelectric domains to the nanometer scale (i.e., 2–3 nm), such as in the case of the P(VDF-TrFE-CTFE) terpolymer, electrostriction with low hysteresis could be achieved. Here, two origins of the large electrostriction in these polymers were identified. The first was the mechano-electrostriction due to the poling field-induced conformation transformation of oriented polymer chains. The second was the electric repulsion of electrically aligned nanodomains. These effects could occur in both crystals and the oriented amorphous fraction, which links between the nanocrystals and the isotropic amorphous fraction. When the poling field was relatively low (e.g., <40 MV/m), the mechano-electrostriction was the major contribution and the electric repulsion effect was a minor contribution to electrostriction. Meanwhile, a strong temperature dependence of the low-field electrostriction coefficient was observed. Finally, we found an empirical inverse relationship between the electrostriction coefficient and the product of Young’s modulus and dielectric constant. The knowledge obtained from this study provides an insightful understanding of the electrostriction mechanism in PVDF-based electroactive polymers, which will find potential applications in sensors and actuators for wearable electronics and soft robotics.

36 MATERIALS SCIENCE↗

Crystallization Mechanisms of Poly(vinylidene Fluoride- co -chlorotrifluoroethylene): Nucleation Transitions, Growth Kinetics, and Microstructure Evolution

The crystallization kinetics of FK-800, a commercial semicrystalline copolymer of chlorotrifluoroethylene and vinylidene fluoride (poly(CTFE-co-VDF)), dictate its microstructure and functional performance. Crystallization occurs between the glass transition (T g ≈ 31 °C) and melting point (T m ≈ 110 °C), with grain boundaries playing a key role in applications such as memristors, where they regulate filament growth. This study integrates in situ atomic force microscopy (AFM), grazing-incidence wide-angle X-ray scattering (GIWAXS), and differential scanning calorimetry (DSC) to characterize nucleation, growth, and morphology across the full crystallization window. Hot-stage AFM reveals a transition from homogeneous to heterogeneous nucleation near 45 °C and a shift from reaction-limited to diffusion-limited growth above 60 °C. Kinetics are analyzed using Lauritzen–Hoffman, Turnbull–Fisher, and Avrami models to extract surface free energies and activation barriers. A multiscale modeling framework is developed in which nucleation densities and growth rates measured by AFM are used to reconstruct Avrami kinetics, which are then validated against coverage data, and extrapolated to predict bulk crystallization behavior observed by DSC. GIWAXS confirms a primarily flat-on chain orientation at all temperatures, linking orientation to domain morphology. This integrative approach quantitatively connects nanoscale crystallization dynamics with macroscopic phase evolution, establishing a quantitative framework for modeling crystallization across time, temperature, and length scales.

Crystallization↗

Shock Initiation of PBX 9502: Material Lots 006 and 007 heated to 76 Celsius

Two shock initiation experiments have been carried out on PBX 9502 material Lots 006 and 007 heated to 76 Celsius. The purpose of these shots is to assess the reactant equation of state and shock-todetonation transition behavior relative to previously characterized lots of heated PBX 9502. PBX 9502 consists of 95% tri-amino-tri-nitro-benzene (TATB) and 5% Kel-F 800 (a copolymer derived from the monomers chlorotrifluorethylene (CTFE) and vinylidine fluoride) by weight. The experiments carried out at the TA-40 Chamber 9 gas gun facility were subject to shock pressures of 12.01 and 11.44 GPa for shots 2s-1129 and 2s-1130 respectively. These pressures resulted in run-to-detonation transitions of 7.91 and 8.73 mm from the impact plane. Unfortunately, due to a series of problems with the heating system the Lot 007 shot was subject to temperature cycling twice before the experiment was fired. The results do not indicate that this had any effect on the sensitivity of the explosive. In terms of shock sensitivity the Lot 006 and 007 PBX 9502 was found to be much less sensitive than the recycled lot 004 when heated to 76 Celsius. The data actually lies closer to the suit of ambient data on the Pop Plot.

36 MATERIALS SCIENCE↗

Evaluation of textiles proposed for spacecraft crew apparel

Textiles proposed for spacecraft wearing apparel were tested for possible primary irritancy and allergenicity using guinea pigs and human subjects. The materials submitted for testing were: (1) blue, loosely knit fabric of a copolymer of chlorotrifluoroethylene and ethylene (CTFE), (2) a white fabric, 100% cotton double knit, treated with fire retardant Tetrakis (hydroxymethyl) phosphonium hydroxide/ammonia, and (3) a gold colored polyimide fabric. There were no adverse reactions to any of the fabrics.

Duncan, W. C.↗

Ion beam sputtering of fluoropolymers

Ion beam sputter processing rates as well as pertinent characteristics of etched targets and films are described. An argon ion beam source was used to sputter etch and deposit the fluoropolymers PTFE, FEP, and CTFE. Ion beam energy, current density, and target temperature were varied to examine effects on etch and deposition rates. The ion etched fluoropolymers yield cone or spire-like surface structures which vary depending upon the type of polymer, ion beam power density, etch time, and target temperature. Sputter target and film characteristics documented by spectral transmittance measurements, X-ray diffraction, ESCA, and SEM photomicrographs are included.

Sovey, J. S.↗

Ion beam sputtering of fluoropolymers

Etching and deposition of fluoropolymers are of considerable industrial interest for applications dealing with adhesion, chemical inertness, hydrophobicity, and dielectric properties. This paper describes ion beam sputter processing rates as well as pertinent characteristics of etched targets and films. An argon ion beam source was used to sputter etch and deposit the fluoropolymers PTFE, FEP, and CTFE. Ion beam energy, current density, and target temperature were varied to examine effects on etch and deposition rates. The ion etched fluoropolymers yield cone or spire-like surface structures which vary depending upon the type of polymer, ion beam power density, etch time, and target temperature. Also presented are sputter target and film characteristics which were documented by spectral transmittance measurements, X-ray diffraction, ESCA, and SEM photomicrographs.

Sovey, J. S.↗

Ignition Resistance of Polymeric Materials to Particle Impact in High-Pressure Oxygen

Particle impact ignition has been the primary cause of numerous fires in oxygen systems. This ignition phenomenon is known to occur where particles are present in high-velocity gas, and where impact occurs on a flammable material. The particle impact ignition behavior of many metals has been widely studied, but the particle impact ignition behavior of polymeric materials is relatively unknown. Particle impact ignition in polymeric materials is a concern as these materials are commonly used in component seat and seal applications, where high-velocity particle impacts can occur. This study evaluates several polymeric materials and compares the minimum temperature required for ignition (threshold temperature) of these materials: Kel-F 81 (CTFE), Teflon (PTFE), PEEK, Vespel SP-21, and Nylon 6/6. The materials were configured as targets in the White Sands Test Facility high-velocity particle impact test system. Gaseous oxygen was flowed at 4000 psi and sonic velocity, and the targets were impacted with 2000-micron aluminum 2017 particles. This paper discusses the results of these tests and ranks the materials according to their threshold temperatures at these conditions.

Forsyth, Elliot T.↗

A Preliminary Study on the Toxic Combustion Products Testing of Polymers Used in High-Pressure Oxygen Systems

One likely cause of polymer ignition in a high-pressure oxygen system is adiabatic-compression heating of polymers caused by pneumatic impact. Oxidative _ pyrolysis or combustion of polymers in a high-pressure oxygen system could generate toxic gases. This paper reports the preliminary results of toxic combustion product testing of selected polymers in a pneumatic-impact test system. Five polymers commonly used in high-pressure oxygen systems, Nylon 6/6, polychlorotrifluoroethylene (CTFE), polytetrafluoroethylene (PTFE), fluoroelastomer (Viton(TradeMark) A), and nitrile rubber (Buna N), were tested in a pneumatic-impact test system at 2500- or 3500-psia oxygen pressure. The polymers were ignited and burned, then combustion products were collected in a stainless-steel sample bottle and analyzed by GC/MS/IRD, GC/FID, and GC/Methanizer/FID. The results of adiabatic-compression tests show that combustion of hydrocarbon polymers, nitrogen-containing polymers, and halogenated polymers in high-pressure oxygen systems are relatively complete. Toxicity of the combustion product gas is presumably much lower than the combustion product gas generated from ambient-pressure oxygen (or air) environments. The NASA-Lewis equilibrium code was used to determine the composition of combustion product gas generated from a simulated, adiabatic-compression test of nine polymers. The results are presented and discussed.

Hshieh, Fu-Yu↗