Search NASASearch

SEARCH · Search NASA

Results for “CURING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ensemble cure kinetics network (ECK-Net): A method to derive cure kinetics of thermosetting resin

This paper introduces an Ensemble Cure Kinetics Network (ECK-Net), a neural network (NN)–based framework for modeling the cure kinetics of thermosetting resins within a phenomenological context. ECK-Net replaces traditional analytic models, which require extensive chemical insight and multiple isothermal/non-isothermal experiments, with a data-driven surrogate that maps nonlinear relationships between temperature, degree of cure, and reaction rate from differential scanning calorimetry data. The proposed approach predicts input-dependent kinetic coefficients of a generalized nth-order reaction equation rather than reaction rates directly, enabling a single unified model to represent various epoxy systems without relying on iso-conversional analysis or predefined functional forms. To ensure robustness, multiple independently trained networks under different random initializations are blended through an ensemble strategy, effectively mitigating the stochastic variability inherent to neural networks. The framework is validated using experimental datasets from multiple resin systems, including aerospace-grade materials (Toray 3900-2, Cycom 5320-1, and Hexcel 8552) and a windmill-grade resin (RIMR 035c). The model accurately reproduces the temporal evolution of the degree of cure under manufacturers’ recommended cure cycles across all tested resins systems, yielding Pearson’s correlation coefficients of 0.992, 0.994, 0.993, 0.997, respectively. To demonstrate process-level applicability, the trained network was implemented within the Abaqus environment to simulate out-of-autoclave (OOA) curing process of the CFRP panel composed of Toray T830H-6K/3900-2D prepreg. The simulation results showed excellent agreement with experimental temperature response (maximum peak temperature, simulation: 189.6 °C, experiment: 188.5 °C) and the final degree of cure (simulation: 0.948, experiment: 0.960 ± 0.013), confirming ECK-Net’s capability as a reliable alternative to conventional cure kinetics modeling methods.

Composite curing

Curing agent for polyepoxides and epoxy resins and composites cured therewith

A curing for a polyepoxide is described which contains a divalent aryl radical such as phenylene a tetravalent aryl radical such as a tetravalent benzene radical. An epoxide is cured by admixture with the curing agent. The cured epoxy product retains the usual properties of cured epoxides and, in addition, has a higher char residue after burning, on the order of 45% by weight. The higher char residue is of value in preventing release to the atmosphere of carbon fibers from carbon fiber-epoxy resin composites in the event of burning of the composite.

Serafini, T. T.

Characterization of the relationship of the cure cycle chemistry to cure cycle processing properties

Dynamic Dielectric measurements made over a wide range of frequency provide a sensitive and convenient means for monitoring the cure process in thermosets and thermoplastics. The measurement of dielectric relaxation is one of only a few instrumental techniques available for studying molecular properties in both the liquid and solid states. Furthermore, it is probably the only convenient experimental technique for studying the polymerization process of going from a monomeric liquid of varying viscosity to a crosslinked, insoluble, high temperature solid. The objective of the research is to develop on-line dielectric instrumentation for quantitative nondestructive material evaluation and closed loop smart cure cycle control. The key is to relate the chemistry of the cure cycle process to the dielectric properties of the polymer system by correlating the time, temperature, and frequency dependent dielectric measurements with chemical characterization measurements. Measurement of the wide variation in magnitude of the complex permittivity with both frequency and state of cure, coupled with chemical characterization work, have been shown in the laboratory to have the potential to determine: resin quality, composition and age; cure cycle window boundaries; onset of flow and point of maximum flow; extent of and completion of reaction; evolution of volatiles; T sub g; and, crosslinking and molecular weight buildup.

Kranbuehl, D. E.

Modeling the curing process of thick-section autoclave cured composites

Temperature gradients are significant during cure of large area, thick-section composites. Such temperature gradients result in nonuniformly cured parts with high void contents, poor ply compaction, and variations in the fiber/resin distribution. A model was developed to determine the temperature distribution in thick-section autoclave cured composites. Using the model, long with temperature measurements obtained from the thick-section composites, the effects of various processing parameters on the thermal response of the composites were examined. A one-dimensional heat transfer model was constructed for the composite-tool assembly. The governing differential equations and associated boundary conditions describing one-dimensional unsteady heat-conduction in the composite, tool plate, and pressure plate are given. Solution of the thermal model was obtained using an implicit finite difference technique.

Loos, A. C.

Photo-Curing: UV Radiation curing of polymers

The Polymers Branch of the Materials Division is dedicated to the development of high-performance for a variety of applications. Areas of significant interest include high- temperature polymers, low density, and high strength insulating materials, conductive polymers, and high density polymer electrolytes. This summer our group is working diligently on a photo-curing project. There is interest in the medical community feel the need for a new and improved balloon that will be used for angioplasty (a form of heart surgery). This product should maintain flexibility but add many other properties. Like possibly further processability and resistance to infection. Our group intends on coming up with this product by using photo-enolization (or simply, photo-curing) by Diels-Alder trapping. The main objective was to synthesize a series of new polymers by Diels-Alder cycloaddition of photoenols with more elastomeric properties. Our group was responsible for performing the proper photo-curing techniques of the polymers with diacrylates and bismaleimides, synthesizing novel monomers, and evaluating experimental results. We attempted to use a diacrylate to synthesize the polymer because of previous research done within the Polymers Branch here at NASA. Most acrylates are commercially available, have more elastometric properties than a typical rigid aromatic structure has and they contain ethylene oxides in the middle of their structure that create extensive flexibility. The problem we encountered with the acrylates is that they photo chemically and thermally self polymerize and create diradicals at low temperatures; these constraints caused a lot of unnecessary side reactions. We want to promote solely, diketone polymerization because this type of polymerization has the ability to cause very elastic polymers. We chose to direct our attention towards the usage of maleimides because they are known for eliminating these unnecessary side reactions.

Inman, Christina A.

Characterization of the relationship of the cure cycle chemistry to cure cycle processing properties

Dynamic dielectric analysis (DDA) is used to study curing polymer systems and thermoplastics. Measurements are made over a frequency range of six decades. This wide range of frequencies increases the amount of information which can be obtained. The data is analyzed in terms of the frequency dependence of the complex permittivity epsilon sup *, specific conductivity sigma (ohm/cm) and the relaxation time tau, parameters which are characteristic of the cure state of the material and independent of the size of the sample.

Kranbuehl, D. E.

Structure-to-property relationships in addition cured polymers. 4: Correlations between thermo-oxidative weight losses of norbornenyl cured polyimide resins and their composites

Relationships are identified between the thermo-oxidative stability (TOS) at 316 C of a wide variety of PMR (polymerization of monomeric reactants) addition cured polyimide resins and their corresponding graphite fiber composites. Weight loss results at 316 C confirmed the expected relationship of increasing aliphatic endcap content with decreasing TOS. Moreover, the resin TOS study also showed an unexpected linear correlation of decreasing weight loss to increasing ratio of benzylic diamine to aliphatic endcap in the range of the stoichiometries studied. Only after long term 316 C aging does the dianhydride used with the benzylic diamines become an additional factor in influencing the amount of PMR resin and composite weight losses. Also, the benzylic systems consistently showed much lower resin and composite weight losses at 316 C than the corresponding nonbenzylic norbornenyl resins and composites, except when the nonbenzylic diamine monomer does not contain a connecting group. Instead, this diamine resulted in a 316 C resin and composite weight loss that was only competitive with benzylic type diamines. Results show excellent correlation between TOS of all graphite fiber PMR composites and resins.

Alston, William B.

Structure-to-property Relationships in Addition Cured Polymers 2: Resin Tg Composite Initial Mechanical Properties of Norbornenyl Cured Polyimide Resins

PRM (polymerization of monomeric reactants) methodology was used to prepare thirty different polyimide oligomeric resins. Monomeric composition as well as chain length between sites of crosslinks were varied to examine their effects on glass transition temperature (Tg) of the cured/postcured resins. An almost linear correlation of Tg versus molecular distance between the crosslinks was observed. An attempt was made to correlate Tg with initial mechanical properties (flexural strength and interlaminar shear strength) of unidirectional graphite fiber composites prepared with these resins. However, the scatter in mechanical strength data prevented obtaining as clear a correlation as was observed for the structural modification/crosslink distance versus Tg. Instead, only a range of composite mechanical properties was obtained at the test temperatures studied (room temperature, 288 and 316 C). Perhaps more importantly, what did become apparent during the attempted correlation study was: (1) that PMR methodology could be used to prepare composites from resins that contain a wide variety of monomer modifications, and (2) that these composites almost invariably provided satisfactory initial mechanical properties as long as the resins selected were melt processable.

Alston, W. B.

Structure-to-property relationships in addition cured polymers. II - Resin Tg and composite initial mechanical properties of norbornenyl cured polyimide resins

PRM (polymerization of monomeric reactants) methodology was used to prepare thirty different polyimide oligomeric resins. Monomeric composition as well as chain length between sites of crosslinks were varied to examine their effects on glass transition temperature (Tg) of the cured/postcured resins. An almost linear correlation of Tg versus molecular distance between the crosslinks was observed. An attempt was made to correlate Tg with initial mechanical properties (flexural strength and interlaminar shear strength) of unidirectional graphite fiber composites prepared with these resins. However, the scatter in mechanical strength data prevented obtaining as clear a correlation as was observed for the structural modification/crosslink distance versus Tg. Instead, only a range of composite mechanical properties was obtained at the test temperatures studied (room temperature, 288 and 316 C). Perhaps more importantly, what did become apparent during the attempted correlation study was: (1) that PMR methodology could be used to prepare composites from resins that contain a wide variety of monomer modifications, and (2) that these composites almost invariably provided satisfactory initial mechanical properties as long as the resins selected were melt processable.

Alston, William B.

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson

Composite Cure Process Modeling and Simulations using COMPRO(Registered Trademark) and Validation of Residual Strains using Fiber Optics Sensors

Composite cure process induced residual strains and warping deformations in composite components present significant challenges in the manufacturing of advanced composite structure. As a part of the Manufacturing Process and Simulation initiative of the NASA Advanced Composite Project (ACP), research is being conducted on the composite cure process by developing an understanding of the fundamental mechanisms by which the process induced factors influence the residual responses. In this regard, analytical studies have been conducted on the cure process modeling of composite structural parts with varied physical, thermal, and resin flow process characteristics. The cure process simulation results were analyzed to interpret the cure response predictions based on the underlying physics incorporated into the modeling tool. In the cure-kinetic analysis, the model predictions on the degree of cure, resin viscosity and modulus were interpreted with reference to the temperature distribution in the composite panel part and tool setup during autoclave or hot-press curing cycles. In the fiber-bed compaction simulation, the pore pressure and resin flow velocity in the porous media models, and the compaction strain responses under applied pressure were studied to interpret the fiber volume fraction distribution predictions. In the structural simulation, the effect of temperature on the resin and ply modulus, and thermal coefficient changes during curing on predicted mechanical strains and chemical cure shrinkage strains were studied to understand the residual strains and stress response predictions. In addition to computational analysis, experimental studies were conducted to measure strains during the curing of laminated panels by means of optical fiber Bragg grating sensors (FBGs) embedded in the resin impregnated panels. The residual strain measurements from laboratory tests were then compared with the analytical model predictions. The paper describes the cure process procedures and residual strain predications, and discusses pertinent experimental results from the validation studies.

Sreekantamurthy, Thammaiah

Dynamic mechanical characterization of cure of a polyimide-graphite fiber composite (PMR 15/Celion 6000)

Dynamic mechanical studies of thermosetting PMR 15 polyimide/Celion 6000 composites were used to characterize cure behavior. Variation in composite shear modulus with cure time for laminates partially cured under 3.45 MPa pressure was compared with that of laminates fully cured under pressure to select a partially cured system whose behavior corresponded with that of the pressure-cured composites. An empirical kinetic model was developed that relates relative composite shear moduli to cure time and temperature. This model, coupled with standard statistical techniques, was used in the determination of an overall activation energy, E = 145 kj/mole (35 kcal/mole) and order of reaction, n, for the cure reaction(s). The empirical relationship defining dynamic modulus as a function of time and temperature remained linear well into the glassy region. Changes in dynamic glass-transition temperature and in the breadth of the transition peaks with cure time are discussed. Shear modulus and damping were found to be more sensitive measures of relative extent of cure than Fourier transform infrared spectroscopy.

Hurwitz, F. I.

Design of an Automated Ultrasonic Scanning System for In-Situ Composite Cure Monitoring and Defect Detection

The preliminary design and development of an automated ultrasonic scanning system for in-situ composite cure monitoring and defect detection in the high temperature environment of an oven was completed. This preliminary design is a stepping stone to deployment in the high temperature and high pressure environment of an autoclave, the primary cure method of aerospace grade thermoset composites. Cure monitoring with real-time defect detection during the process could determine when defects form and how they move. In addition, real-time defect detection during cure could assist validating physics-based process models for predicting defects at all stages of the cure cycle. A physics-based process model for predicting porosity and fiber waviness originating during cure is currently under development by the NASA Advanced Composites Project (ACP). For the design, an ultrasonic contact scanner is enclosed in an insulating box that is placed inside an oven during cure. Throughout the cure cycle, the box is nitrogen-cooled to approximately room temperature to maintain a standard operating environment for the scanner. The composite part is mounted on the outside of the box in a vacuum bag on the build/tool plate. The build plate is attached to the bottom surface of the box. The scanner inspects the composite panel through the build plate, tracking the movement of defects introduced during layup and searching for new defects that may form during cure. The focus of this paper is the evaluation and selection of the build plate material and thickness. The selection was based on the required operating temperature of the scanner, the cure temperature of the composite material, thermal conductivity models of the candidate build plates, and a series of ultrasonic attenuation tests. This analysis led to the determination that a 63.5 mm thick build plate of borosilicate glass would be utilized for the system. The borosilicate glass plate was selected as the build plate material due to the low ultrasonic attenuation it demonstrated, its ability to efficiently insulate the scanner while supporting an elevated temperature on the part side of the plate, and the availability of a 63.5 mm thick plate without the need for lamination.

Hudson, Tyler B.

Structural and Dynamical Insights into the Formation Process of a Cross-Linked Polymer Network in Acrylic Adhesives During Thermal Curing

Many modern adhesives, sealants, and coatings rely on the controlled transition from a liquid to a solid state by forming a three-dimensional cross-linked polymer network, often referred to as curing. The curing process, which is initiated by the mixing of reactive components or an external trigger, defines the structure of a network and further controls the final mechanical properties of cured materials. However, the curing mechanism is not fully understood yet due to the lack of experimental tools capable of directly probing the structure and dynamics of a network over relevant time- and length scales. Here, in this paper, we report the curing process of a commercial two-component methyl methacrylate (MMA) adhesive using in operando X-ray photon correlation spectroscopy (XPCS), a method that closely simulates the target manufacturing environment of the adhesive. The results are then integrated with those obtained by rheology, differential scanning calorimetry (DSC), and transmission electron microscopy to establish the structure–dynamics–process–property relationship. The XPCS results identify four distinct stages in the curing process after the mixing, extrusion, and deposition of the acrylic adhesive: (i) At a cure time (or “aging time”, t age ) of less than 1 min, nanodomains of polymerized MMA are formed within a liquid monomeric MMA matrix. The average size is several nm and remains constant over t age , while the dynamics of the nanodomains are slowed down with t age due to an increase in the viscosity of the MMA matrix. (ii) After t age > 1 min, the size of the nanodomains increases with t age until the gel point (= 6.3 min after mixing as determined by rheology). The dynamics of the nanodomains also increase due to the heat generated by the exothermic reaction. (iii) At the gel point, the nanodomains begin to interconnect each other, resulting in a network structure with a characteristic length of about 100 nm. This characteristic network size does not change for the rest of the curing process up to t age = 500 min. The dynamics of the network structure, however, show a rapid slowing down with t age up to t age ≈ 12 min, corresponding to the onset of vitrification (as determined by rheology). (iv) At t age > 12 min, when the DSC and rheology data can no longer provide meaningful information, the XPCS data show a further slowing down of the network dynamics associated with vitrification. Our results provide rich and complex insights into the physics and material design of thermosets in commercially relevant processes, which are essential for future industrial applications.

36 MATERIALS SCIENCE

Study of catalyst cured LaRC-160/Celion 6000 composites

LaRC 160 polyimide was modified with a high temperature peroxide catalyst, USP-138, in an attempt to reduce the final cure temperature to below 316 C. This effort was directed at obtaining a material for 177 C use that would cure at similar temperatures to a high performance epoxy while still maintaining the good moisture resistance of a polymide material. Attempts to prepare a laminate made from Celion 6000 fiber and 5% catalyzed LaRC 160 resin gave a material with minimal properties after curing at 193 C. Acceptable properties were not obtained until a final cure temperature of 260 C was used. A control laminate containing no catalyst and cured under the same conditions had only half the level of shear strength. The catalyzed LaRC 160 prepreg was also used to examine the possibility of shortening the conventional LaRC 160 cure at 316 C. Maximum properties were obtained using a 2.5% catalyzed product with a final cure temperature of 316 C held for fifteen minutes. Differences in properties between catalyzed and uncatalyzed product disappeared, however, when the cure time at 316 C was extended to 45 minutes.

Edelman, R.

Ultrasonic mixing of epoxy curing agents

A new technique for mixing solid curing agents into liquid epoxy resins using ultrasonic energy was developed. This procedure allows standard curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminobenzophenone (4,4 prime-DABP) (242 C) to be mixed without premature curing. Four aromatic diamines were ultrasonically blended into MY-720 epoxy resin. These were 4,4 prime-DDS; 3,3 prime-DDA; 4,4 prime-DABP and 3,3 prime-DABP. Unfilled moldings were cast and cured for each system and their physical and mechanical properties compared.

Hodges, W. T.

Ultrasonic mixing of epoxy curing agents

A new technique for mixing solid curing agents into liquid epoxy resins using ultrasonic energy was developed. This procedure allows standard curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminobenzophenone (4,4 prime-DABP) (242 C) to be mixed without premature curing. Four aromatic diamines were ultrasonically blended into MY-720 epoxy resin. These were 4, 4 prime-DDS; 3,3 prime-DDA; 4, 4 prime-DABP and 3,3 prime-DABP. Unfilled moldings were cast and cured for each system and their physical and mechanical properties compared. Previously announced in STAR as N83-27018

Hodges, W. T.

A Study of Upgraded Phenolic Curing for RSRM Nozzle Rings

A thermochemical cure model for predicting temperature and degree of cure profiles in curing phenolic parts was developed, validated and refined over several years. The model supports optimization of cure cycles and allows input of properties based upon the types of material and the process by which these materials are used to make nozzle components. The model has been refined to use sophisticated computer graphics to demonstrate the changes in temperature and degree of cure during the curing process. The effort discussed in the paper will be the conversion from an outdated solid modeling input program and SINDA analysis code to an integrated solid modeling and analysis package (I-DEAS solid model and TMG). Also discussed will be the incorporation of updated material properties obtained during full scale curing tests into the cure models and the results for all the Reusable Solid Rocket Motor (RSRM) nozzle rings.

Smartt, Ziba