Search NASASearch

SEARCH · Search NASA

Results for “CURRENT DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Uniform secondary current distribution at disk electrodes under Tafel kinetics enabled by concentric current-shielding rings

Non-uniform secondary current distribution at rotating disk electrodes (RDE) is a common problem when using resistive electrolyte media or large applied currents. In a recent publication, we have shown that auxiliary electrodes such as the ring of a rotating ring disk electrode (RRDE) can help suppress current non-uniformities at the disk enabling reliable electroanalytical measurements. However, this previous work considered linear kinetics where current distribution non-uniformities were moderate. In the present contribution, we consider current distribution non-uniformities encountered under Tafel kinetics. We show, for the case of 2,5-dihydroxy-1,4-benzoquinone (DHBQ) reduction, that optimally chosen ring conditions serve to provide effective shielding at the disk edge rendering the overall disk current distribution to be uniform. Numerical modeling and scaling analysis (using the Wagner number) are presented to aid a user in determining the optimal ring current density for achieving uniform disk current distribution under Tafel kinetics. This approach is especially useful when studying soluble-soluble redox transitions for which, unlike deposit distribution in electrodeposition, the current distribution non-uniformity is not visually apparent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Kinetics Measurements in Resistive Electrolytes Using Ring-Disk Electrode: Ring as Current “Shield” Enables Uniform Disk Current Distribution

Rotating disk electrodes are commonly used for electrochemical kinetics measurements. A major disadvantage of these types of electrodes is their nonuniform secondary current distribution, especially when performing electroanalytical measurements in resistive electrolytes. Such nonuniform current distribution can render the values of kinetics constants extracted from the disk electrode to be highly inaccurate. Furthermore, one emerging class of electrolytes that suffer from low ionic conductivities is deep eutectic solvents (DES). DES are a promising class of electrolytes for various emerging applications; however, due to their resistive nature, the secondary current distribution when using them is typically highly nonuniform. For example, the Wagner number when measuring Cu²⁺/Cu⁺ kinetics in choline chloride–ethylene glycol DES (1:4 molar ratio of ChCl:EG) is very low (<0.1), indicating highly nonuniform current distribution over the disk electrode. We show here that the Cu²⁺/Cu⁺ exchange current density measured using disk electrodes is very inaccurate due to the aforementioned nonuniform current distribution. To obtain uniform disk current distribution, we employ here a coplanar concentric rotating ring-disk electrode (RRDE), where the ring serves the function of a current “shield.” Specifically, we show using modeling that the ring minimizes the current distribution nonuniformity at the disk by effectively shielding the disk against current spikes near the disk edge. This enables improved precision in electrode kinetics measurements for the Cu²⁺/Cu⁺ couple in resistive DES. To enable broad applicability of this technique, an analytical expression based on the Wagner number is integrated into an iterative algorithm to help users identify ring conditions to achieve uniform current distribution and thus improved electroanalytics at the disk.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Impact of uniform electrode current distribution on ETF

A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

Bents, D. J.

Impact of uniform electrode current distribution on ETF

The design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution are examined and the alternate consolidation design which occur are presented compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is given for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

Bents, D. J.

Comparison of Measured Leakage Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distribution were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [I]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Car10 code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. The nuclear elastic component (also calculated using the MCNPX) has a negligible effect on the shape of the damage distribution. The Coulombic contribution was calculated using MRED [3,4], a Geant4 [4,5] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.