Search NASA⌕ Search

SEARCH · Search NASA

Results for “CUSTOMER DAMAGE FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Understand the Costs of an Energy or Water Outage with the Customer Damage Function Calculator

The Customer Damage Function (CDF) Calculator is a free, publicly available web tool that helps users estimate the costs incurred at their site due to an electric grid or water service outage. Developed by the National Renewable Energy Laboratory (NREL) with support from the Federal Energy Management Program (FEMP), the tool is designed to help federal facility owners, building energy managers, and resilience planners understand and quantify the value of resilience to justify investments that would prevent or lessen the impact of a disruption.

CDF Calculator↗

Advancing Federal Infrastructure Through Innovation: Customer Damage Function Calculator

Provides an overview of the National Renewable Energy Laboratory (NREL) Customer Damage Function (CDF) Calculator web tool, developed with funding and support from the Federal Energy Management Program (FEMP). The CDF Calculator is a screening tool that provides justification to site and/or headquarters leadership for resilience investments. It generates monetary values to justify investments in resilience solutions to prevent or lessen the impact of a grid outage at a facility.

CDF calculator↗

Valuing Energy Security: Customer Damage Function Methodology and Case Studies at DoD Installations

This report describes a methodology to value non-energy savings that can be attributed to energy security projects. The methodology is based on: (1) completing a site survey to collect data on two hypothetical outage scenarios lasting for different durations to compute a customer damage function (CDF), which represents interruption costs as a function of the outage duration; (2) characterizing the reliability of the commercial power supply at the site; and (3) estimating the value of electrical energy security (VEES), which is a metric that characterizes on an annual basis the cost of utility outages. The avoided cost of commercial power outages can be used as ancillary non-energy savings to increase the return on investment of energy security projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A flexible framework for modeling customer damage functions for power outages

This paper develops a flexible method for estimating the customer cost of a power outage. We add to the current body of literature by outlining a framework which properly accounts for the effects of outage duration. We begin by separating costs into categories depending on whether the cost varies with outage duration and whether the cost is due to perishable inventory. We derive useful functional forms for each cost category and discuss how parameters vary by load type and outage characteristics. We derive outage cost estimates for an unexpected loss of power to both an example manufacturing plant and an example fire station. The framework described in this paper can easily be employed to model outage costs for a wide range of specific operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Updated Value of Service Reliability Estimates for Electric Utility Customers in the United States

This report updates the 2009 meta-analysis that provides estimates of the value of service reliability for electricity customers in the United States (U.S.). The meta-dataset now includes 34 different datasets from surveys fielded by 10 different utility companies between 1989 and 2012. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods, it was possible to integrate their results into a single meta-dataset describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the U.S. for industrial, commercial, and residential customers. This report focuses on the backwards stepwise selection process that was used to develop the final revised model for all customer classes. Across customer classes, the revised customer interruption cost model has improved significantly because it incorporates more data and does not include the many extraneous variables that were in the original specification from the 2009 meta-analysis. The backwards stepwise selection process led to a more parsimonious model that only included key variables, while still achieving comparable out-of-sample predictive performance. In turn, users of interruption cost estimation tools such as the Interruption Cost Estimate (ICE) Calculator will have less customer characteristics information to provide and the associated inputs page will be far less cumbersome. The upcoming new version of the ICE Calculator is anticipated to be released in 2015.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimated Value of Service Reliability for Electric Utility Customers in the United States

Information on the value of reliable electricity service can be used to assess the economic efficiency of investments in generation, transmission and distribution systems, to strategically target investments to customer segments that receive the most benefit from system improvements, and to numerically quantify the risk associated with different operating, planning and investment strategies. This paper summarizes research designed to provide estimates of the value of service reliability for electricity customers in the US. These estimates were obtained by analyzing the results from 28 customer value of service reliability studies conducted by 10 major US electric utilities over the 16 year period from 1989 to 2005. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods it was possible to integrate their results into a single meta-database describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the US for industrial, commercial, and residential customers. Estimated interruption costs for different types of customers and of different duration are provided. Finally, additional research and development designed to expand the usefulness of this powerful database and analysis are suggested.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantifying the economic costs of power outages owing to extreme events: A systematic review

Quantifying the economic cost of long-duration power outages is crucial to justifying investments in resiliency and reliability improvements. However, extensive study on the subject complicates the identification of power outage costs and determining the most suitable approach to quantify them for an individual, specific facility, particularly in the context of extreme events. Here, this research provides a systematic review of economic studies estimating the impact of environmental disasters at the microeconomic and macroeconomic levels. Of 326 articles, evaluating the costs of power outages in extreme events, this work identified 22 studies that attempted to quantify the economic costs. These findings indicate that quantifying power outage costs lacks standardization, posing challenges for comparing different studies. Most analyses aiming to quantify these costs for utilities, sectors, and the overall economy rely on outdated survey data, which offer generalized rather than specific cost estimations. The costs of power outages exhibit a significant dependence on factors such as the sector involved, the type of customer affected, and the outage duration. To quantify industry costs, the research in this study suggests that using the National Renewable Energy Laboratory's online, open-access Customer Damage Function Calculator is the best option for individual-level assessments of industries, hospitals, offices, education centers, and similar facilities. However, the Interruption Cost Estimate Calculator can estimate outage costs across industrial, commercial, and residential sectors for macroeconomic outcomes. Finally, this article discusses the relative strengths of these methods and tools and the potential directions for future research.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BuD, a helix–loop–helix DNA-binding domain for genome modification

Crystal structures of BurrH and the BurrH–DNA complex are reported. DNA editing offers new possibilities in synthetic biology and biomedicine for modulation or modification of cellular functions to organisms. However, inaccuracy in this process may lead to genome damage. To address this important problem, a strategy allowing specific gene modification has been achieved through the addition, removal or exchange of DNA sequences using customized proteins and the endogenous DNA-repair machinery. Therefore, the engineering of specific protein–DNA interactions in protein scaffolds is key to providing ‘toolkits’ for precise genome modification or regulation of gene expression. In a search for putative DNA-binding domains, BurrH, a protein that recognizes a 19 bp DNA target, was identified. Here, its apo and DNA-bound crystal structures are reported, revealing a central region containing 19 repeats of a helix–loop–helix modular domain (BurrH domain; BuD), which identifies the DNA target by a single residue-to-nucleotide code, thus facilitating its redesign for gene targeting. New DNA-binding specificities have been engineered in this template, showing that BuD-derived nucleases (BuDNs) induce high levels of gene targeting in a locus of the human haemoglobin β (HBB) gene close to mutations responsible for sickle-cell anaemia. Hence, the unique combination of high efficiency and specificity of the BuD arrays can push forward diverse genome-modification approaches for cell or organism redesign, opening new avenues for gene editing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Polarizing Splitter Optics in Extreme Environments

Development of laser systems capable of surviving extreme conditions experienced in military applications requires mounts and components that are able to survive these conditions. The characterization of mounted and/or bonded optical assemblies in harsh environments is critical for the development of laser and optical systems for functionality in these extreme conditions. Customized mounts, bonding assemblies and packaging strategies are utilized to develop and field reliable and robust optical subassemblies. Thin film polarizers operating at 45o and polarizing beam splitter cubes were chosen for initial testing based on past experiences, advancements in optical coating and construction technologies and material properties. Shock, vibration, shear strength, tensile strength and temperature testing are performed on mounted polarizing beam splitter cubes and thin film polarizers from two manufacturers. Previous testing showed that polarizing beam splitter cubes constructed using epoxy would become damaged in the laser resonator. The cubes being tested in this report are constructed using epoxy- free direct optical contact bonding. Thin film polarizers operating at 45o are chosen opposed to Brewster’s angle thin film polarizers to reduce the size and simplify design and construction since an optical wedge is not required. The components and mounts are each environmentally tested beyond the manufacturers’ specifications for shock, vibration, and temperature. Component functionality is monitored during and after the environmental testing. Experimental results from the testing will be discussed as will the impact on future laser resonator designs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Exponential Increase in Relative Biological Effectiveness Along Distal Edge of a Proton Bragg Peak as Measured by Deoxyribonucleic Acid Double-Strand Breaks

Purpose: To quantify the relative biological effectiveness (RBE) of the distal edge of the proton Bragg peak, using an in vitro assay of DNA double-strand breaks (DSBs). Methods and Materials: U2OS cells were irradiated within the plateau of a spread-out Bragg peak and at each millimeter position along the distal edge using a custom slide holder, allowing for simultaneous measurement of physical dose. A reference radiation signal was generated using photons. The DNA DSBs at 3 hours (to assess for early damage) and at 24 hours (to assess for residual damage and repair) after irradiation were measured using the γH2AX assay and quantified via flow cytometry. Results were confirmed with clonogenic survival assays. A detailed map of the RBE as a function of depth along the Bragg peak was generated using γH2AX measurements as a biological endpoint. Results: At 3 hours after irradiation, DNA DSBs were higher with protons at every point along the distal edge compared with samples irradiated with photons to similar doses. This effect was even more pronounced after 24 hours, indicating that the impact of DNA repair is less after proton irradiation relative to photons. The RBE demonstrated an exponential increase as a function of depth and was measured to be as high as 4.0 after 3 hours and as high as 6.0 after 24 hours. When the RBE-corrected dose was plotted as a function of depth, the peak effective dose was extended 2-3 mm beyond what would be expected with physical measurement. Conclusions: We generated a highly comprehensive map of the RBE of the distal edge of the Bragg peak, using a direct assay of DNA DSBs in vitro. Our data show that the RBE of the distal edge increases with depth and is significantly higher than previously reported estimates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 2-Stage Genome-Wide Association Study to Identify Single Nucleotide Polymorphisms Associated With Development of Erectile Dysfunction Following Radiation Therapy for Prostate Cancer

Purpose: To identify single nucleotide polymorphisms (SNPs) associated with development of erectile dysfunction (ED) among prostate cancer patients treated with radiation therapy. Methods and Materials: A 2-stage genome-wide association study was performed. Patients were split randomly into a stage I discovery cohort (132 cases, 103 controls) and a stage II replication cohort (128 cases, 102 controls). The discovery cohort was genotyped using Affymetrix 6.0 genome-wide arrays. The 940 top ranking SNPs selected from the discovery cohort were genotyped in the replication cohort using Illumina iSelect custom SNP arrays. Results: Twelve SNPs identified in the discovery cohort and validated in the replication cohort were associated with development of ED following radiation therapy (Fisher combined P values 2.1 Multiplication-Sign 10{sup -5} to 6.2 Multiplication-Sign 10{sup -4}). Notably, these 12 SNPs lie in or near genes involved in erectile function or other normal cellular functions (adhesion and signaling) rather than DNA damage repair. In a multivariable model including nongenetic risk factors, the odds ratios for these SNPs ranged from 1.6 to 5.6 in the pooled cohort. There was a striking relationship between the cumulative number of SNP risk alleles an individual possessed and ED status (Sommers' D P value = 1.7 Multiplication-Sign 10{sup -29}). A 1-allele increase in cumulative SNP score increased the odds for developing ED by a factor of 2.2 (P value = 2.1 Multiplication-Sign 10{sup -19}). The cumulative SNP score model had a sensitivity of 84% and specificity of 75% for prediction of developing ED at the radiation therapy planning stage. Conclusions: This genome-wide association study identified a set of SNPs that are associated with development of ED following radiation therapy. These candidate genetic predictors warrant more definitive validation in an independent cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale design of nonlinear materials using a Eulerian shape optimization scheme

Motivated by recent advances in manufacturing, the design of materials is the focal point of interest in the material research community. One of the critical challenges in this field is finding optimal material microstructure for a desired macroscopic response. This work presents a computational method for the mesoscale-level design of particulate composites for an optimal macroscale-level response. The method relies on a custom shape optimization scheme to find the extrema of a nonlinear cost function subject to a set of constraints. Three key “modules” constitute the method: multiscale modeling, sensitivity analysis, and optimization. Multiscale modeling relies on a classical homogenization method and a nonlinear NURBS-based generalized finite element scheme to efficiently and accurately compute the structural response of particulate composites using a nonconformal discretization. A three-parameter isotropic damage law is used to model microstructure-level failure. An analytical sensitivity method is developed to compute the derivatives of the cost/constraint functions with respect to the design variables that control the microstructure's geometry. The derivation uncovers subtle but essential new terms contributing to the sensitivity of finite element shape functions and their spatial derivatives. Several structural problems are solved to demonstrate the applicability, performance, and accuracy of the method for the design of particulate composites with a desired macroscopic nonlinear stress-strain response.

42 ENGINEERING↗

Use of Unmanned Aerial Systems for Post-closure Waste Site Maintenance and Surveillance - 20143

The P- and R-Area Reactor buildings, located at SRS near Aiken, SC, were in-situ decommissioned by grouting below-grade portions of the buildings and demolishing some above-grade structures to grade level. Other reactor building structures were left above-grade and sealed to prevent human or animal access. Because the above grade-structures are expected to continue in their present state for hundreds of years, the condition of the building roofs is critical to mitigate rainwater intrusion. For this reason, building roof areas were strengthened with high strength concrete to ensure the long-term integrity of the roof structure. Periodic inspections of the roof structures are required to ensure that the roofs are functioning properly and to identify damage areas. The traditional method of inspecting closed reactor buildings requires the use of a helicopter and photographer to generate photographs and videos for review. This method proved sufficient but lacked the resolution and clarity that is required for a thorough inspection of the building structure. Fortunately, the Savannah River National Laboratory (SRNL) has established a Small Unmanned Aircraft System (sUAS) program using commercially available and custom-built remote-controlled aircraft. EC and ACP contacted the SRNL program to evaluate whether the sUAS technology could be employed for periodic reactor building inspections. The sUAS can fly within a few meters of the reactor buildings and hover, allowing for a more thorough aerial inspection. The initial sUAS inspection of the P-Area Reactor building was completed in February 2018 and at the R-Area Reactor building in August 2018 and were successful in providing higher resolution photos and videos. The sUAS inspections also revealed that vegetation had begun to grow on the roofs that could potentially damage the structure integrity. SRNL partnered with Virginia Polytechnic Institute and State University to build a custom heavy lift sUAS that could be equipped with herbicides to remotely treat the vegetative growth. Herbicides were successfully applied to the R-Area Reactor building roof using the custom sUAS in September 2018. The use of unmanned aircraft systems at SRS to perform aerial inspections and herbicide treatment in otherwise inaccessible areas has proven to be an efficient and cost-effective technology that provides high value, increases knowledge of facility conditions, and provides for early detection of damage. Periodic inspections of the reactor building roofs using sUAS technology are performed safely, efficiently, and at a significant cost and schedule savings while reducing emissions, noise, and fossil fuel use. The use of sUAS equipment for building inspections and herbicide application at SRS is unique within the DOE complex. The goal of SRS is to apply this remote technology to other waste unit operations and maintenance activities in the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Meshfree Methods

Meshfree methods have undergone substantial development and have received much attention in the last two decades. This new family of numerical methods is designed to inherit the main advantages of the finite element method such as compact supports of shape functions and good approximation properties while, at the same time, overcome the main disadvantages of the finite element method caused by the mesh dependence. The meshfree methods share a common feature that no mesh is needed and shape functions are constructed from sets of points, thus eliminating the need for time consuming mesh generation. The most significant advantage of meshfree methods is the flexibility in customizing approximation functions for desired regularity and for capturing essential physics and features of the particular problems of interest. Adaptivity formulation and multiple-scale solution strategies also can be implemented with relative ease. It has become clear that the meshfree methods provide considerable advantages over the conventional finite element methods in solving problems involving moving discontinuities, evolving material interfaces, multiple-scale phenomena, large material distortion and structural deformation, and fracture and damage processes. This Chapter gives an overview of many classes of meshfree methods, with more detailed discussions on Smoothed Particle Hydrodynamics (SPH), the Reproducing Kernel Particle Method (RKPM), Peridynamics (PD), the Material Point Method (MPM), as well as their applications in various challenging engineering problems.2

Chen, Jiun-Shyan↗

WE-EF-BRA-09: Microbeam Radiation Therapy Enhances Tumor Drug Uptake of PEGylated Liposomal Doxorubicin (PLD) in a Triple Negative Breast Cancer GEM Model

Purpose: Overcoming low anti-cancer drug uptake in tumors is a key challenge limiting its clinical use. We propose to enhance the drug delivery using upfront Microbeam Radiation Therapy (MRT). MRT is a preclinical cancer therapy that utilizes microplanar beams to deliver spatially oscillating planes of high and low doses. Animal studies have demonstrated that ultrahigh dose (100s Gy) MRT eradicates tumors without damaging the function of normal tissue exposed to the same radiation. Our previous study indicated that MRT induces intense angiogenesis in tumor rim and surrounding normal tissue 1–2 days post radiation. We hypothesize that the tumor microenvironment modulation induced by MRT may enhance carrier-mediated agent drug delivery to tumors with inherent poor drug uptake. We thus investigated MRT-induced pharmacokinetics (PK) of PEGylated liposomal doxorubicin (PLD), a nano-scale doxorubicin, in T11 genetically engineered mouse model of triple negative breast cancer. Methods: A research irradiator (160kVp, RadSource Technologies) with a customized collimator was used to produce the MRT microbeam of in average 390µm width and 1190µm peak-to-peak distance. The peak dose rate of 1–2Gy/min. Dosimetry is by EBT3 film cross-calibrated with ion chamber at large fields. All mice were administered PLD at 6mg/kg IV x1 at 16h post MRT and sacrificed at 5min, 6h, 24h, and 96h post PLD administration (n=3 or 4 per group). Results: The MRT(28Gy)+PLD group mice had a total doxorubicin tumor concentration (area-under-the concentration-curve, AUC) of 206,040ng/mL•h, 3.71 times the concentration of the PLD-alone group. The MRT(34Gy)+PLD group had a higher mean total doxorubicin concentration in tumor (20,779ng/ml) than the MRT(28Gy)+PLD group (10,665ng/ml). Conclusion: Our preliminary results indicate that microbeam radiation therapy (MRT) can enhance nano-scale anti-cancer drug delivery to tumors approximately 4-fold. The exact working mechanism, the comparison with broad beam irradiation, and optimization of MRT for drug delivery enhancement are under investigation.

60 APPLIED LIFE SCIENCES↗

Long-term monitoring experiences at the HADES underground lab and its relevance for radwaste repository monitoring

In the frame of its radwaste disposal research programme, SCK-CEN started the construction of the HADES underground research facility in 1980. Including several extensions and a comprehensive experimental programme, it has provided a lot of experience on monitoring. Monitoring is performed for many reasons: construction follow-up, field characterisation, investigation of phenomena, and model validations - in which the underground lab offers the opportunity for up-scaling conventional laboratory set-ups. Construction monitoring has allowed to develop and optimise the underground construction techniques in a previously poorly known environment, resulting in a well-mastered application of mechanised methods for gallery construction with minimal damage to the host formation. Access to this formation also allows its characterisation, both geotechnical, geological and geochemical, and the detailed investigation of phenomena such as fracturing and oxidation. Finally, instrumented set-ups allow to test various numerical models by comparing the observations with the predicted behaviour. The specific conditions of the underground laboratory put particular requirements to the sensors. These conditions include the long-term nature of many set-ups - typically several years to decades, the inaccessibility of many sensors after installation, high mechanical and water pressures, and corrosion. Combined with the fact that many sensors are custom made, obtaining and maintaining a fully functional instrumented set-up can be challenging. A lot of experience has therefore been gained which is very valuable when designing the monitoring of radwaste repositories - and it has allowed us to determine the critical success factors for monitoring. Engineers tend to look at this first from a technical viewpoint - and there are many technical aspects indeed that determine the reliability of monitoring. A first one is the combination of different observations ('redundancy') which can be implemented by the use of several sensors, different sensor principles, different (coupled) parameters, and the combination of point measurements with geophysical techniques. Cabling is also a critical issue as it is often considered as the primary enemy of barrier integrity. Minimal cabling techniques, such as distributed fibre optic monitoring and wireless signal transmission, therefore get increasing attention. Also the interpretation of the monitoring data - in particular those that are perceived as 'wrong' or 'unexpected', needs sufficient attention. The long-term experience has however also shown that the design of a monitoring programme must look beyond the technical part. In particular for long-term applications, issues such as data management and record keeping are vital to guarantee success in this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation Inc. that is designed to operate on live cables up to 1000 volts. One of the main conclusions of a previous effort was that cable reflectometry plots can be difficult for humans to analyze due to baseline noise, low or noisy anomaly response peaks, or large responses from cable ends. Detection of cable anomalies for many of these frequencies and test conditions was challenging for manual analysis. This presented an ideal opportunity for ML analysis to distinguish undamaged cable indications from anomalous cable indications. This research discusses application of machine learning (ML) to reflectometry cable test methods. The goal was to assess feasibility to distinguish undamaged cable reflectometry responses from damaged or anomalous cable reflectometry responses. The assessment considered the 3 instruments, multiple frequency bandwidths from each instrument, multiple cable anomalies and test conditions, and both supervised and unsupervised ML approaches. Although approaches and analysis methods were not identical or directly comparable, both outputs were encouraging. The unsupervised prediction weighted accuracy was assessed by instrument and by frequency. It performed better at high frequencies with the highest prediction accuracy of 0.84 for the higher frequency FDR, 0.79 for the 48-MHz LiveWire SSTDR, and 0.77 for 300-MHz PNNL SSTDR. The initial weighted accuracy average across all frequencies for using supervised ML was 0.56 to 0.68. The supervised analysis was repeated with noisier training data removed resulting in weighted accuracies of 0.69 to 0.87. These weighted accuracies are not directly comparable due to differences in the supervised and unsupervised analysis details but do indicate an encouraging trend. Even with limited and unbalanced data, strong prediction accuracies seem encouraging for further work including more data under a wider range of conditions.

42 ENGINEERING↗