Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING↗

An Iterative Bidirectional Gradient Boosting Algorithm for CVR Baseline Estimation

This paper presents a novel iterative, bidirectional, gradient boosting (bidirectional-GB) algorithm for estimating the baseline of the Conservation Voltage Reduction (CVR) program. We define the CVR baseline as the load profile during the CVR period if the substation voltage is not lowered. The proposed algorithm consists of two key steps: selection of similar days and iterative bidirectional-GB training. In the first step, preand post-event temperature profiles of the targeted CVR day are used to select similar days from historical non-CVR days. In the second step, the pre-event and post-event similar days are used to train two GBMs iteratively: a forward-GBM and a backwardGBM. After each iteration, the two generated CVR baselines are reconciled and only the first and the last points on the reconciled baseline are kept. The iteration repeats until all CVR baseline points are generated. We tested two gradient boosting methods (i.e., GBM and LighGBM) with two data resolutions (i.e., 15and 30-minute). The results demonstrate that both the accuracy and performance of the algorithm are satisfactory.

Lee, Han Pyo↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Smart Grid-Enabled CVR: An Advanced Application for Distribution Management Systems

A multilevel, multitasking smart grid-enabled conservation of voltage reduction (CVR) control and optimization methodology is proposed for advanced distribution management system (ADMS) platforms. The first level deals with the centralized optimization of volt/VAR optimization (VVO) devices; the second-level is for voltage control in the local domain or decentralized control; and the third level assesses the energy savings and CVR factor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Event-Driven Predictive Approach for Real-Time Volt/VAR control with CVR in solar PV rich Active Distribution Network

The focus of this paper is on analyzing the impact of conservation voltage reduction in the presence of active devices such as solar photovoltaic (PV) and developing controls that leverage these distributed energy resources. An event-driven predictive approach for real-time volt/volt-ampere reactive (VAR) optimization, along with local two-level adaptive volt/VAR droop-based control algorithm for advanced distribution management systems, is introduced. The methodology covers aggregated and autonomous controls under different timescale operations, including the impact and effect of unpredicted events such as cloud transients on PV power production. In addition, the control schemes include the uncertainties in PV power generation and load power demand. The proposed methodology is validated in a real-time framework using the real-time digital simulator platform through co-simulation with models based on Python and OpenDSS (Open Distribution System Simulator). The developed methodology is tested on the modified IEEE 123-feeder test system. The results reveal that the proposed methodology works well in the presence of high penetrations of PV power, produces significant energy savings, and mitigates over-/undervoltage problems.

14 SOLAR ENERGY↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Maximizing the Benefits of Volt/VAR Optimization in the Presence of Community Energy Storage

This paper reports on the need for coordinating smart grid volt/volt-ampere reactive (VAR) control (VVC) and community energy storage (CES) to maximize the benefits of both approaches. It addresses a key application of volt/VAR optimization (VVO): the conservation of voltage reduction (CVR). The lack of coordination among network controls, such as VVO, and asset controls at the community battery storage system can lead to detrimental effects on grid operation. A smart grid-enabled VVC uses the VVO to perform the CVR operation. VVO can perform numerous tasks for advanced distribution management systems with coordination of the system operator. To achieve the optimal VVC solution, we use a particle swarm optimization driven VVO method. The test system has been simulated for two scenarios-during light loading and high loading condition-with and without the CES system. In both scenarios, the operation of CVR and CES have been performed considering different case studies. The outcomes of the simulated results demonstrate that significant improvement in peak load-demand reduction is achieved by the proposed VVC and CES system with reduced system losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bi-Level Volt-VAR Optimization to Coordinate Smart Inverters with Voltage Control Devices

Conservation voltage reduction (CVR) uses voltage control to reduce customer power demand and help improve the operational efficiency of the electric power distribution system. With the advent of advanced distribution management systems (ADMS), the underlying data and control-rich platform can be utilized to enable a centralized Volt-VAR optimization (VVO) scheme that includes smart inverter controls along with legacy voltage control devices such as voltage regulators and capacitor banks to ensure a maximum CVR benefit. The objective of this paper to present a VVO approach that controls system’s legacy voltage control devices and coordinates their operation with smart inverter control. An optimal power flow (OPF) formulation is proposed by developing linear and nonlinear power flow approximations for a three-phase unbalanced electric power distribution system. A bi-level VVO approach is proposed where, Level-1 optimizes the control of legacy devices and smart inverters using a linear approximate three-phase power flow. In Level-2, the control parameters for smart inverters are adjusted to obtain an optimal and feasible solution by solving the approximate nonlinear OPF model. Level-1 is modeled as a Mixed Integer Linear Program (MILP) while Level-2 as a Quadratically Constrained Quadratic Program (QCQP). The proposed approach is validated using IEEE test cases and the results demonstrate the applicability of the framework in achieving the CVR objective.

Jha, Rahul Ranjan↗

Analysis of Crew Fatigue in AIA Guantanamo Bay Aviation Accident

Flight operations can engender fatigue, which can affect flight crew performance, vigilance, and mood. The National Transportation Safety Board (NTSB) requested the NASA Fatigue Countermeasures Program to analyze crew fatigue factors in an aviation accident that occurred at Guantanamo Bay, Cuba. There are specific fatigue factors that can be considered in such investigations: cumulative sleep loss, continuous hours of wakefulness prior to the incident or accident, and the time of day at which the accident occurred. Data from the NTSB Human Performance Investigator's Factual Report, the Operations Group Chairman's Factual Report, and the Flight 808 Crew Statements were analyzed, using conservative estimates and averages to reconcile discrepancies among the sources. Analysis of these data determined the following: the entire crew displayed cumulative sleep loss, operated during an extended period of continuous wakefulness, and obtained sleep at times in opposition to the circadian disposition for sleep, and that the accident occurred in the afternoon window of physiological sleepiness. In addition to these findings, evidence that fatigue affected performance was suggested by the cockpit voice recorder (CVR) transcript as well as in the captain's testimony. Examples from the CVR showed degraded decision-making skills, fixation, and slowed responses, all of which can be affected by fatigue; also, the captain testified to feeling "lethargic and indifferent" just prior to the accident. Therefore, the sleep/wake history data supports the hypothesis that fatigue was a factor that affected crewmembers' performance. Furthermore, the examples from the CVR and the captain's testimony support the hypothesis that the fatigue had an impact on specific actions involved in the occurrence of the accident.

Rosekind, Mark R.↗

Distributed Algorithm for Volt-VAr Optimization in Unbalanced Distribution System

Conservation voltage reduction (CVR) is implemented in the distribution system to reduce the voltage along the feeder with the objective to reduce the power consumption. Due to the increased penetration of distributed generators in the distribution system the centralized control is cumbersome. Hence, in this paper, a distributed algorithm is proposed for volt-var optimization (VVO) with CVR objective in a three-phase unbalanced distribution network. The proposed method is based on alternating direction method of multipliers (ADMM) algorithm. Mathematically the problem is formulated as a convex optimization problem with reactive power support from smart inverters. The convexity guarantees the solution obtained using the proposed method is a converged solution. The proposed method is validated on IEEE 4-bus and 13-bus three-phase unbalanced systems.

ADMM↗

Performance Evaluation of Next-Generation Grid Automation and Controls with High PV Penetration

This paper presents a hardware-in-the-loop (BIL) simulation to evaluate the performance of an advanced grid automation architecture, referred to as data-enhanced hierarchical control (DEHC), in achieving voltage regulation and conservation voltage reduction (CVR) in distribution networks with very high photovoltaic (PV) generation. This architecture comprises an advanced distribution management system (ADMS), a distributed energy resource management system (DERMS), and grid-edge devices working synergistically to provide the grid benefits. The HIL setup used for the evaluation includes ADMS, DERMS, and grid-edge devices. The DEHC performance is evaluated in two representative scenarios considering loose and tight constraints of the power factor at the substation. The results show that the DEHC architecture is effective in achieving voltage regulation and CVR and thus enables the grid integration of high levels of PV generation.

ADMS↗

Deposition of tantalum carbide coatings on graphite by laser interactions

Graphite surfaces can be hardened and protected from erosion by hydrogen at high temperatures by refractory metal carbide coatings, which are usually prepared by chemical vapor deposition (CVD) or chemical vapor reaction (CVR) methods. These techniques rely on heating the substrate to a temperature where a volatile metal halide decomposes and reacts with either a hydrocarbon gas or with carbon from the substrate. For CVR techniques, deposition temperatures must be in excess of 2000 C in order to achieve favorable deposition kinetics. In an effort to lower the bulk substrate deposition temperature, the use of laser interactions with both the substrate and the metal halide deposition gas has been employed. Initial testing involved the use of a CO2 laser to heat the surface of a graphite substrate and a KrF excimer laser to accomplish a photodecomposition of TaCl5 gas near the substrate. The results of preliminary experiments using these techniques are described.

Veligdan, James↗

Effect of acute exposure to hypergravity (GX vs. GZ) on dynamic cerebral autoregulation

We examined the effects of 30 min of exposure to either +3GX (front-to-back) or +GZ (head-to-foot) centrifugation on cerebrovascular responses to 80 degrees head-up tilt (HUT) in 14 healthy individuals. Both before and after +3 GX or +3 GZ centrifugation, eye-level blood pressure (BP(eye)), end tidal PCO2 (PET(CO2)), mean cerebral flow velocity (CFV) in the middle cerebral artery (transcranial Doppler ultrasound), cerebral vascular resistance (CVR), and dynamic cerebral autoregulatory gain (GAIN) were measured with subjects in the supine position and during subsequent 80 degrees HUT for 30 min. Mean BP(eye) decreased with HUT in both the GX (n = 7) and GZ (n = 7) groups (P < 0.001), with the decrease being greater after centrifugation only in the GZ group (P < 0.05). PET(CO2) also decreased with HUT in both groups (P < 0.01), but the absolute level of decrease was unaffected by centrifugation. CFV decreased during HUT more significantly after centrifugation than before centrifugation in both groups (P < 0.02). However, these greater decreases were not associated with greater increases in CVR. In the supine position after centrifugation compared with before centrifugation, GAIN increased in both groups (P < 0.05, suggesting an autoregulatory deficit), with the change being correlated to a measure of otolith function (the linear vestibulo-ocular reflex) in the GX group (r = 0.76, P < 0.05) but not in the GZ group (r = 0.24, P = 0.60). However, GAIN was subsequently restored to precentrifugation levels during postcentrifugation HUT (i.e., as BP(eye) decreased), suggesting that both types of centrifugation resulted in a leftward shift of the cerebral autoregulation curve. We speculate that this leftward shift may have been due to vestibular activation (especially during +GX) or potentially to an adaptation to reduced cerebral perfusion pressure during +GZ.

NASA Discipline Neuroscience↗