Optimized anion exchange column isolation of zirconium-89 (89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

Zirconium-89 (89Zr), produced by the (p,n) reaction from naturally monoisotopic yttrium (natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capture Zr from a load solution that is high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>105) and has been shown to separate Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the performance of the method was evaluated using cyclotron bombarded Y foil targets. The separation method was shown to achieve >95% recovery of the 89Zr present in the foils. The 89Zr eluent, however, was in a chemical matrix not immediately conducive to labeling onto proteins. The main intent of this study was to develop a tandem column 89Zr purification process, wherein the anion exchange column method described here is the first separation in a dual-column purification process.

Zirconium-89, ImmunoPET, medical isotope, automati↗

Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) at the cyclotron frequency instead of the reduced cyclotron frequency has been experimentally demonstrated using narrow aperture detection electrode (NADEL) ICR cells. Here, based on the results of SIMION simulations, we provide the initial mechanistic insights into the cyclotron frequency regime generation in FT-ICR MS. The reason for cyclotron frequency regime is found to be a new type of a collective motion of ions with a certain dispersion in the initial characteristics, such as pre-excitation ion velocities, in a highly non-quadratic trapping potential as realized in NADEL ICR cells. During ion detection, ions of the same m/z move in phase for cyclotron ion motion but out of phase for magnetron (drift) ion motion destroying signals at the fundamental and high order harmonics that comprise reduced cyclotron frequency components. After an initial magnetron motion period, ion clouds distribute into a novel type of structures – ion slabs, elliptical cylinders, or star-like structures. These structures rotate at the Larmor (half-cyclotron) frequency on a plane orthogonal to the magnetic field, inducing signals at the true cyclotron frequency on each of the narrow aperture detection electrodes. To eliminate the reduced cyclotron frequency peak upon dipolar ion detection, a number of slabs or elliptical cylinders organizing a star-like configuration are formed. In a NADEL ICR cell with quadrupolar ion detection, a single slab or an elliptical cylinder is sufficient to minimize the intensity of the reduced cyclotron frequency components, particularly the second harmonic. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mode structure measurements of ion cyclotron emission and sub-cyclotron modes on DIII-D

We report mode structure measurements of coherent ion cyclotron emission (ICE) and sub-cyclotron modes on DIII-D. Through a dedicated experiment, we aimed to characterize a variety of modes via the upgraded ICE diagnostic in both L- and H-mode plasmas. In the L-mode plasmas, autopower spectrum peaks at harmonics of the ion cyclotron frequency fci were observed and are localized in the core of the plasma. Sub-cyclotron modes (f ~ 0.5f ci ) were also observed in L-mode plasmas when the toroidal magnetic field strength was lowered from B T = 2.17 T. In H-mode plasmas, many ICE harmonics localized to the plasma edge were observed, with some exceeding the nominal ICE diagnostic bandwidth of f ϵ [0, 100] MHz. Polarization estimates made using an orthogonal pair of vertical and horizontal magnetic pickup loops on the outer wall of the machine indicate that ICE and sub-cyclotron modes have compressional polarization at the plasma edge, the latter being consistent with simulation efforts for comparable DIII-D plasmas. For all modes, the same harmonics are observed on both the centerpost and outer wall loops, indicating that ICE is poloidally extended. Finally, toroidal mode numbers were calculated using three outer wall loops for both core ICE and sub-cyclotron modes in L-mode plasmas. Furthermore, the sub-cyclotron case served as a benchmark for our calculation method, with measured numbers of n ϵ [–24, –18] roughly agreeing with heuristic estimates of n ϵ [–20, –13]. Core ICE mode numbers were measured to be n ϵ [–10, 5], which is comparable to measurements made on other machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic hydrogen-cyclotron wave emission below the hydrogen-cyclotron frequency in the auroral acceleration region

A mechanism is suggested for the excitation of electrostatic ion-cyclotron waves at frequencies below the ion-cyclotron frequency in the midst of the auroral acceleration region, which is assumed to consist of downward moving double layers. The mechanism involves upward flowing ions interacting with a downward flowing background plasma. The upward flowing ions are the ion beams accelerated by the double layer. The downward motion of the background plasma corresponds to a plasma expansion into the density cavity that develops in connection with double layer formation in the acceleration region. The ion-cyclotron waves excited by the counterstreaming flows are doppler shifted to frequencies below the harmonics of the ion cyclotron frequency. It is suggested that such wave emissions could account for some very narrow-banded waves at frequencies below the hydrogen cyclotron frequency that were observed by the S3-3 satellite.

Singh, N.↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: III. Novel sub-cyclotron modes

Dedicated DIII-D experiments studied instabilities above and below the ion cyclotron frequency by injecting thirteen different neutral beam populations into L-mode plasmas with different thermal compositions of H, D, and 3 He at five different values of toroidal field. Two companion papers describe the results of these experiments in detail. This paper focuses on data and analysis of two instabilities that occur at ${\sim}0.6$ of the deuterium and hydrogen cyclotron frequencies $f_\mathrm {cD}$ and $f_\mathrm {cH}$ in mixed hydrogen and deuterium plasmas. The modes below $f_\mathrm {cD}$ are often driven unstable by deuterium beams but are rarely destabilized by hydrogen beams. The modes below $f_\mathrm {CD}$ are reported here for the first time in a fusion plasma. These $\mathrm{sub-}f_\mathrm {cH}$ modes are only driven by deuterium beams but, unlike the $\mathrm{sub-}f_\mathrm {cD}$ modes, they are only unstable in plasmas with deuterium concentrations that are ${\lesssim}20\%$; they also have a smaller amplitude than the sub-deuterium modes. Addition of fully-ionized 3 He to the plasma has little effect on the sub-cyclotron deuterium modes but is stabilizing for the sub-cyclotron hydrogen modes. The modes are excited in the core and have toroidal mode numbers around 20. These trends are compared with calculations of the growth rate in a simplified model. The theory successfully predicts global Alfvén eigenmode instability with frequencies and mode numbers close to experimental values, the stronger amplitude of the sub-deuterium modes, and the species-mix dependence of the sub-hydrogen modes. Increased damping associated with the ion-ion hybrid, cutoff, and crossover frequencies plausibly accounts for the stabilization of the $\mathrm{sub-}f_\mathrm {cH}$ modes when 3 He is puffed. However, the relative stability of $\mathrm{sub-}f_\mathrm {cH}$ modes during hydrogen injection remains unexplained.

electromagnetic ion cyclotron instability↗

Low-noise heterodyne receiver for electron cyclotron emission imaging and microwave imaging reflectometry

The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50–150 GHz) to an intermediate frequency (IF) band (e.g. 0.1–18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads to 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron radiated power in cyclotron radiation emission spectroscopy experiments

The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio-frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclotron breaking: a mechanism for parallel ion cyclotron waves to heat the fast solar wind

The Parker Solar Probe mission has observed near-continuous power in parallel ion cyclotron waves (PICWs) in the young, fast solar wind. These waves are unlikely to be directly produced by the turbulent cascade and are likely born of a local instability; yet, they are observed to both cool – and heat – the plasma. We propose that these observations can be self-consistently explained as the natural consequence of PICWs propagating in the inhomogeneous solar wind after they have been driven unstable. In this work, we argue that strong proton heating by a turbulent cascade of oblique ICWs will result in PICWs being driven unstable in a process known as quasi-linear focusing. Because the power in the turbulent cascade is concentrated at scales above the turbulent transition region, PICWs will be driven unstable within a range of wavenumbers parallel to the background magnetic field, 𝑘 ∥ , that is bounded from above by 𝑘$^{∗}_{∥P}$, corresponding to the start of the transition region. As unstable PICWs propagate away from the Sun to regions of lower proton density, their 𝑘 ∥ , multiplied by the proton inertial length 𝑑 p , increases. Eventually, 𝑘$^{∗}_{∥P}$ of the PICWs becomes larger than 𝑘$^{∗}_{∥P}$⁢𝑑 p and the waves damp, heating the solar wind. We call this effect ‘cyclotron breaking’, in analogy with ocean waves breaking on the shore. We then discuss the testable predictions of the theory, including a distinct heating signature in which PICWs cool fast protons and heat slow protons at any given heliocentric distance 𝑟. Finally, we conjecture that cyclotron breaking can lead to net heating by PICWs if the power emitted as PICWs decreases sufficiently rapidly with 𝑟 that local emission of PICWs is overwhelmed by the local damping of PICWs generated closer to the Sun.

plasma heating↗

Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic

Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns

The development of a tandem column purification method for the production of high-purity 89Zr is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of ~27 µL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1±1.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29±0.06 mL (representing 86±5% of the 89Zr activity in the target). This product volume represents a significant increase in isotope product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 TBq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. These ESA and [MB] values infer that the 89Zr product resulting from this tandem column isolation method has the highest purity reported to date.

immunoPET, zirconium-89, laboratory automation, de↗

Simultaneous detection of neoclassical tearing mode and electron cyclotron current drive locations using electron cyclotron emission in DIII-D

Accurate real-time measurements of magnetic island and electron cyclotron current drive (ECCD) locations are essential for efficient suppression of the neoclassical tearing mode (NTM). To identify these locations, many control systems rely on motional Stark effect constrained equilibria reconstruction and real-time Thomson scattering with TORBEAM current drive evaluation and therefore require time-intensive cross-calibration of at least two different diagnostics. Here we present a simpler, proof-of-concept analysis that uses only a single diagnostic (a radial array electron cyclotron emission radiometer) for the simultaneous determination of both the radial position of a magnetic island and the deposition location of ECCD. Measurements are compared with the modified Rutherford equation to demonstrate the effect of ECCD alignment on NTM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface-Induced Dissociation of Protein Complexes in a Hybrid Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Mass spectrometry continues to develop as a valuable tool in the analysis of proteins and protein complexes. In protein complex mass spectrometry studies, surface-induced dissociation (SID) has been successfully applied in quadrupole time-of-flight (Q-TOF) instruments. SID provides structural information on non-covalent protein complexes that is complementary to other techniques. However, the mass resolution of Q-TOF instruments can limit the information that can be obtained for protein complexes by SID. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provides ultrahigh resolution and ultrahigh mass accuracy measurements. In this study, an SID device was designed and successfully installed in a hybrid FT-ICR instrument in place of the standard gas collision cell. The SID-FT-ICR platform has been tested with several protein complex systems (homooligomers, a heterooligomer, and a protein-ligand complex, ranging from 53 kDa to 85 kDa), and the results are consistent with data previously acquired on Q-TOF platforms, matching predictions from known protein interface information. SID fragments with the same m/z but different charge states are well-resolved based on distinct spacing between adjacent isotope peaks, and the addition of metal cations and ligands can also be isotopically resolved with the ultrahigh mass resolution available in FT-ICR.

Environmental Molecular Sciences Laboratory↗

Electromagnetic ion cyclotron waves observed near the oxygen cyclotron frequency by ISEE 1 and 2

The first results of observations of ion cyclotron waves by the elliptically orbiting ISEE 1 and 2 pair of spacecraft are reported. The most intense waves (8 nT) were observed in the outer plasmasphere where convection drift velocities were largest and the Alfven velocity was a minimum. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by cold plasma propagation theory are identified in the wave data. Computations of the experimental wave spectra during the passage through the plasmapause show that the spectral slots relate to the local plasma parameters, possibly suggesting an ion cyclotron wave growth source near the spacecraft. A regular wave packet structure seen over the first 30 min of the event is attributed to the modulation of this energy source by the Pc 5 waves seen at the same time.

Fraser, B. J.↗