Search NASA⌕ Search

SEARCH · Search NASA

Results for “CYLINDRICAL TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗

Rocking response of liquid-filled cylindrical tanks

The hydrodynamic response of liquid-filled storage tanks subjected to translational earthquake shaking has been the focus of studies for more than 75 years. In service, tanks experience six components of seismic input, with rocking due to support flexibility and/or rotational components of ground motion. Published theory for predicting hydrodynamic responses in rigid cylindrical tanks due to rotational seismic input is examined. Analytical solutions for pressure in the fluid and on the tank wall, and base moment are modified to account for the effects of angular displacements at the base. A finite element model of a water-filled cylindrical tank using the Arbitrary Lagrangian and Eulerian (ALE) solver in LS-DYNA is used to demonstrate the efficacy of the proposed expressions for three base rocking motions. Results from the modified analytical solutions and the finite element model are in excellent agreement.

58 GEOSCIENCES↗

Review of analytical studies on seismic fluid-structure interaction of base-supported cylindrical tanks

Analytical solutions for seismic fluid-structure interaction (FSI) of tanks are used by analysts and engineers for a number of purposes, including preliminary sizing, risk assessment, and verification of numerical models. Analytical solutions for seismic FSI of tanks were first developed in the 1930s and have been extended and/or modified in the following nine decades to accommodate different seismic inputs and boundary conditions. This report reviews published analytical solutions for rigid and flexible, base-supported, cylindrical tanks subjected to unidirectional horizontal motion of a small amplitude. The studies parsed the fluid-structure (FSI) response into an impulsive and a convective component, and addressed frequencies of lateral motions of the tank (i.e., impulsive frequencies), hydrodynamic pressures, frequencies of waves (i.e., convective frequencies), wave heights, and reactions at the base. The solutions were categorized into exact and approximate solutions based on the methodologies used. Herein, FSI responses are calculated and compared for a range of tank dimensions using the analytical solutions from the different studies. The responses presented here are normalized to be unitless, and can be used for tanks with different dimensions and mechanical properties, and subjected to different input motions. A sample steel water tank is analyzed using the normalized solutions for two earthquake ground motions with different frequency contents. Ignoring tank flexibility may significantly underestimate seismic responses of the tank and its contained fluid. The approximate solutions, which have been widely used for decades, may not be sufficiently accurate in the modern era. Calculation errors in the reviewed studies are identified and corrected, and differences are quantified for the sample tank.

42 ENGINEERING↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Numerical and Experimental Results on Mechanical Stirrer and Bubbling in a Cylindrical Tank - 13047

The process of vitrification in a cold crucible heated by direct induction is used in the fusion of oxides. Its feature is the production of high-purity materials. The high-level of purity of the molten is achieved because this melting technique excludes the contamination of the charge by the crucible. The aim of the present paper is to analyze the hydrodynamic of the vitrification process by direct induction, with the focus in the effects associated with the interaction between the mechanical stirrer and bubbling. Considering the complexity of the analyzed system and the goal of the present work, we simplified the system by not taking into account the thermal and electromagnetic phenomena. Based in the concept of hydraulic similitude, we performed an experimental study and a numerical modeling of the simplified model. The results of these two studies were compared and showed a good agreement. The results presented in this paper in conjunction with the previous work contribute to a better understanding of the hydrodynamics effects resulting from the interaction between the mechanical stirrer and air bubbling in the cold crucible heated by direct induction. Further works will take into account thermal and electromagnetic phenomena in the presence of mechanical stirrer and air bubbling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiply Surface-Functionalized Nanoporous Carbon for Vehicular Hydrogen Storage

The purpose of the project “Multiply Surface-Functionalized Nanoporous Carbon for Vehicular Hydrogen Storage” is the development of materials that store hydrogen (H 2 ) by adsorption in quantities and at conditions that outperform current compressed-gas H 2 storage systems for electric power generation from hydrogen fuel cells (HFCs). Prominent areas of interest for HFCs are light-duty vehicles (“hydrogen cars”) and replacement of batteries with HFC systems in a wide spectrum of applications, ranging from forklifts to unmanned areal vehicles to portable power sources. State-of-the-art compressed H 2 tanks operate at pressures between 350 and 700 bar at ambient temperature and store 3-4 percent of H 2 by weight (wt%) and less than 25 grams of H 2 per liter (g/L) of tank volume. Thus, the purpose of the project is to engineer adsorbents that achieve storage capacities better than compressed H 2 at pressures less than 350 bar. Adsorption holds H 2 molecules as a high-density film on the surface of a solid at low pressure, by virtue of attractive surface-gas interactions. At a given pressure, the density of the adsorbed film is the higher the stronger the binding of the molecules to the surface is (high binding energies). Thus, critical for high storage capacities are high surface areas, high binding energies, and low void fractions (high void fractions, such as in interstitial space between adsorbent particles, “waste” storage volume by holding hydrogen as non-adsorbed gas). Coexistence of high surface area and low void fraction makes the ideal adsorbent a nanoporous monolith, with pores wide enough to hold high-density hydrogen films, narrow enough to minimize storage as non-adsorbed gas, and thin walls between pores to minimize the volume occupied by solid instead of hydrogen. A monolith can be machined to fit into a rectangular tank (low pressure, conformable tank), cylindrical tank (high pressure), or other tank shape without any waste of volume.

08 HYDROGEN↗

Validation of numerical models for seismic fluid-structure-interaction analysis of nuclear, safety-related equipment

Seismic design, qualification, and risk assessment of nuclear safety-related vessels filled with liquid will have to consider the interaction between the vessel (tank), the contained liquid, and submerged components, if any. Seismic fluid-structure-interaction (FSI) analysis of nuclear vessels will rely on numerical models, which are required to be verified and validated. This study validates previously-verified numerical models using test data generated from earthquake-simulator experiments involving a cylindrical tank. Two solvers in LS-DYNA for FSI simulations are used for the numerical analysis: Arbitrary-Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD). Numerical and test results are compared for responses critical to seismic design of advanced reactor vessels: hydrodynamic pressures on the tank wall, reactions at the support, and wave heights of the contained liquid. Analysis is performed for one-, two-, and three-directional seismic inputs with a range of intensity, and rocking motions. The accuracy of the numerical results and different methods for outputting wave heights are discussed. Recommendations for validation of seismic FSI numerical models of advanced reactors are provided. As a result, the validation exercise presented in this study is broadly applicable to cylindrical tanks, regardless of industry sector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Integrated heat exchanger design for a cryogenic storage tank

Field demonstrations of liquid hydrogen technology will be undertaken for the proliferation of advanced methods and applications in the use of cryofuels. Advancements in the use of cryofuels for transportation on Earth, from Earth, or in space are envisioned for automobiles, aircraft, rockets, and spacecraft. These advancements rely on practical ways of storage, transfer, and handling of liquid hydrogen. Focusing on storage, an integrated heat exchanger system has been designed for incorporation with an existing storage tank and a reverse Brayton cycle helium refrigerator of capacity 850 watts at 20 K. The storage tank is a 125,000-liter capacity horizontal cylindrical tank, with vacuum jacket and multilayer insulation, and a small 0.6-meter diameter manway opening. Addressed are the specific design challenges associated with the small opening, complete modularity, pressure systems re-certification for lower temperature and pressure service associated with hydrogen densification, and a large 8:1 length-to-diameter ratio for distribution of the cryogenic refrigeration. The approach, problem solving, and system design and analysis for integrated heat exchanger are detailed and discussed. Implications for future space launch facilities are also identified. The objective of the field demonstration will be to test various zero-loss and densified cryofuel handling concepts for future transportation applications.

42 ENGINEERING↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A process to verify numerical models for seismic fluid-structure interaction in advanced reactor vessels

Seismic design and qualification of a liquid-filled advanced nuclear reactor will have to account for fluid-structure interaction (FSI). Interaction between the tank, internal components, and contained liquid will rely on analysis of numerical models that must be verified and validated. Here this study demonstrates a verification process for models of a base-supported cylindrical tank by comparing numerical predictions and analytical solutions. The numerical models are consistent with the assumptions made to derive analytical solutions, namely, either a rigid or a linear elastic tank, ideal fluid, and small-amplitude, unidirectional, horizontal inputs. One software platform is used to illustrate the process. Seismic FSI analysis is performed using the Arbitrary Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD) solvers in LS-DYNA. Reported responses are those used for design, including hydrodynamic pressures on the tank wall, shear forces and moments at the tank base, and wave heights of the contained liquid. The accuracy of the numerical results is discussed. The numerical models are verified for calculating the pressures on the tank wall and reactions at its base. Accurate simulation of wave action is challenging for both solvers. Recommendations for modeling, code development, and steps for verification are provided. Although focused on reactor vessels and one software platform, the verification process described herein is broadly applicable to liquid-filled vessels and other finite element codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Water Ingress Effects on the Reactivity Change of the Conceptual Designed Reactor at NIST

The conceptual research reactor design with a split core for a replacement reactor project at the NIST (National Institute of Standards and Technology) Center for Neutron Research is underway. The reactor core is cooled and moderated by light water and reflected by heavy water in a reflector tank. The reactor core is immersed in light water, which is isolated from heavy water with a slightly pressurized boundary box made of zirconium alloy. The heavy water is contained in a large size cylindrical tank which also provides ample space to accommodate neutron beam tubes, cold sources and other irradiation equipment. The reflector tank is placed in the center of a large light water pool, which provides thermal and biological shielding to the reactor. Light water and heavy water have distinct physical properties in regard to neutron moderation. Light water is generally known to have greater moderating power and absorption cross-sections, while heavy water has a higher moderating ratio. Due to these differences in properties, the accidental mixing of light water and heavy water in either direction will inevitably affect the reactivity of the reactor. Moreover, since the neutron flux spectrum at different locations of the reactor will have significantly different characteristics (for example, the spectrum at the heavy tank should be much softer than that at the core center region), the effect of reactivity changes becomes complicated and will depend on the water mixing locations. From the reactor safety analysis perspective, the water ingress reactivity change is one of the required design base reactivity accidents that must be evaluated in the final safety analysis report. Given these concerns, neutronics calculations have been performed to determine the effect and trend of the reactivity changes due to water ingress in different scenarios by purposely mixing the waters at three representative places in the reactor: the reflector area, the center coolant area and the peripheral coolant area. These three places were selected for the study because of their uniqueness in the flux spectrum (as shown in the results section). Simple static neutronics calculations were performed using MCNP6 to examine the reactivity effects due to water ingress. It should be noted that all calculations performed in this study assume homogeneous water mixing in the area of interest; therefore, the local effect of the mixing situation would possibly be missed by this study. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-294: Simulations to Investigate the Feasibility of ‘dry’ Optical-CT Imaging for 3D Dosimetry

Purpose: To perform simulations investigating the feasibility of “dry” optical-CT, and determine optimal design and scanning parameters for a novel dry tank telecentric optical-CT 3D dosimetry system. Such a system would have important advantages in terms of practical convenience and reduced cost. Methods: A Matlab based ray-tracing simulation platform, ScanSim, was used to model a telecentric system with a polyurethane dry tank, cylindrical dosimeter, and surrounding fluid. This program's capabilities were expanded for the geometry and physics of dry scanning. To categorize the effects of refractive index (RI) mismatches, simulations were run for several dosimeter (RI = 1.5−1.48) and fluid (RI = 1.55−1.33) combinations. Additional simulations examined the effect of increasing gap size (1–5mm) between the dosimeter and tank wall, and of changing the telecentric lens tolerance (0.5°−5°). The evaluation metric is the usable radius; the distance from the dosimeter center where the measured and true doses differ by less than 2%. Results: As the tank/dosimeter RI mismatch increases from 0–0.02, the usable radius decreases from 97.6% to 50.2%. The fluid RI for matching is lower than either the tank or dosimeter RI. Changing gap sizes has drastic effects on the usable radius, requiring more closely matched fluid at large gap sizes. Increasing the telecentric tolerance through a range from 0.5°–5.0° improved the usable radius for every combination of media. Conclusion: Dry optical-CT with telecentric lenses is feasible when the dosimeter and tank RIs are closely matched (<0.01 difference), or when data in the periphery is not required. The ScanSim tool proved very useful in situations when the tank and dosimeter have slight differences in RI by enabling estimation of the optimal choice of RI of the small amount of fluid still required. Some spoiling of the telecentric beam and increasing the tolerance helps recover the usable radius.

07 ISOTOPE AND RADIATION SOURCES↗

ADVANCED MIXING MODELS

The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank with one to four dual-nozzle jet mixers located within the tank. The typical criteria to establish a mixed condition in a tank are based on the number of pumps in operation and the time duration of operation. To ensure that a mixed condition is achieved, operating times are set conservatively long. This approach results in high operational costs because of the long mixing times and high maintenance and repair costs for the same reason. A significant reduction in both of these costs might be realized by reducing the required mixing time based on calculating a reliable indicator of mixing with a suitably validated computer code. The work described in this report establishes the basis for further development of the theory leading to the identified mixing indicators, the benchmark analyses demonstrating their consistency with widely accepted correlations, and the application of those indicators to SRS waste tanks to provide a better, physically based estimate of the required mixing time. Waste storage tanks at SRS contain settled sludge which varies in height from zero to 10 ft. The sludge has been characterized and modeled as micron-sized solids, typically 1 to 5 microns, at weight fractions as high as 20 to 30 wt%, specific gravities to 1.4, and viscosities up to 64 cp during motion. The sludge is suspended and mixed through the use of submersible slurry jet pumps. To suspend settled sludge, water is added to the tank as a slurry medium and stirred with the jet pump. Although there is considerable technical literature on mixing and solid suspension in agitated tanks, very little literature has been published on jet mixing in a large-scale tank. If shorter mixing times can be shown to support Defense Waste Processing Facility (DWPF) or other feed requirements, longer pump lifetimes can be achieved with associated operational cost and schedule savings. The focus of the present work is to establish mixing criteria associated with the waste processing at SRS and to quantify the mixing time required to suspend sludge particles with the submersible jet pump. Literature results for a turbulent jet flow are reviewed briefly, since the decay of the axial jet velocity and the evolution of the jet flow patterns are important phenomena affecting sludge suspension and mixing operations. One of the main objectives in the waste processing is to provide the DWPF a uniform slurry composition at a certain weight percentage (typically {approx}13 wt%) over an extended period of time. In preparation of the sludge for slurrying to DWPF, several important questions have been raised with regard to sludge suspension and mixing of the solid suspension in the bulk of the tank: (1) How much time is required to prepare a slurry with a uniform solid composition for DWPF? (2) How long will it take to suspend and mix the sludge for uniform composition in any particular waste tank? (3) What are good mixing indicators to answer the questions concerning sludge mixing stated above in a general fashion applicable to any waste tank/slurry pump geometry and fluid/sludge combination? Grenville and Tilton (1996) investigated the mixing process by giving a pulse of tracer (electrolyte) through the submersible jet nozzle and by monitoring the conductivity at three locations within the cylindrical tank. They proposed that the mixing process was controlled by the turbulent kinetic energy dissipation rate in the region far away from the jet entrance. They took the energy dissipation rates in the regions remote from the nozzle to be proportional to jet velocity and jet diameter at that location. The reduction in the jet velocity was taken to be proportional to the nozzle velocity and distance from the nozzle. Based on their analysis, a correlation was proposed. The proposed correlation was shown to be valid over a wide range of Reynolds numbers (50,000 to 300,000) with a relative standard deviation of {+-} 11.83%. An improved correlation including the effect of circulation time was proposed by Grenville and Tilton [11] via a better fit of mixing time data for turbulent jet mixing under a wider range of jet Reynolds numbers (50,000 to 300,000). The circulation time was defined as the liquid volume divided by the entrained flow rate. They assumed that the mixing rate at the end of the jet length controls the mixing time for the entire tank by estimating the kinetic energy dissipation rate as discussed earlier. They predicted that for a given volume, an optimum geometry exists for a mixing vessel, allowing a desired mixing time to be achieved for a minimum power input. The current work will compare their correlation of the jet mixing time with CFD modeling results for their experimental tanks in an attempt to achieve a fundamental understanding of the turbulent jet mixing and to establish mixing indicators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploration of multi-fold symmetry element-loaded superconducting radio frequency structure for reliable acceleration of low- & medium-beta ion species

Reliable acceleration of low- to medium-beta proton or heavy ion species is needed for future high-current superconducting radio frequency (SRF) accelerators. Due to the high-Q nature of an SRF resonator, it is sensitive to many factors such as electron loading (from either the accelerated beam or from parasitic field emitted electrons), mechanical vibration, and liquid helium bath pressure fluctuation etc. To increase the stability against those factors, a mechanically strong and stable RF structure is desirable. Guided by this consideration, multi-fold symmetry element-loaded SRF structures (MFSEL), cylindrical tanks with multiple (n>=3) rod-shaped radial elements, are being explored. The top goal of its optimization is to improve mechanical stability. A natural consequence of this structure is a lowered ratio of the peak surface electromagnetic field to the acceleration gradient as compared to the traditional spoke cavity. A disadvantage of this new structure is an increased size for a fixed resonant frequency and optimal beta. This paper describes the optimization of the electro-magnetic (EM) design and preliminary mechanical analysis for such structures.

43 PARTICLE ACCELERATORS↗

Transition from wall modes to multimodality in liquid gallium magnetoconvection

Coupled laboratory-numerical experiments of Rayleigh-Bénard convection in liquid gallium subject to a vertical magnetic field are presented. The experiments are carried out in two cylindrical containers with diameter-to-height aspect ratio Γ = 1.0 and 2.0 at varying thermal forcing (Rayleigh numbers 10 5 ≲ Ra ≲ 10 8 ) and magnetic field strength (Chandrasekhar numbers 0 ≲ Ch ≲ 3 × 10 5 ). Laboratory measurements and numerical simulations confirm that magnetoconvection in our finite cylindrical tanks onsets via nondrifting wall-attached modes, in good agreement with asymptotic predictions for a semi-infinite domain. With increasing supercriticality, the experimental and numerical thermal measurements and the numerical velocity data reveal transitions between wall mode states with different azimuthal mode numbers and between wall-dominated convection to wall and interior multimodality. These transitions are also reflected in the heat transfer data, which combined with previous studies connect onset to supercritical turbulent behaviors in liquid metal magnetoconvection over a large parameter space. The gross heat transfer behaviors between magnetoconvection and rotating convection in liquid metals are compared and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physical Attributes of Pulse Jet Mixer Operation

Vessels mixed using pulse jet mixers that produce a periodic, rather than steady, flow present challenges with respect to modeling slurry mixing. A PJM is a cylindrical tank within the mixed tank that has a conical bottom with an orifice through which process fluid cyclically enters and is expelled forcefully by pressurizing the air space above the liquid in the PJM. Between pulses, some of the solids settle from the slurry, which nominally is a failure in mixing, but during the pulses (if operated to attain bottom clearing conditions), all of the solids are resuspended and made available for processing or transfer. Overall, mixing is successful if the solids are processed and removed from the vessel as needed when averaged over repeated PJM cycles. This paper describes the physics of pulse jet mixing process based on physical observation during experiments and analysis of experimental concentration profile data obtained during the mixing cycle.

Newtonian↗