At least 19 records

An Effective Current Balancing Method for Inverters With Paralleled Silicon Carbide Power Modules

Silicon carbide (SiC) MOSFET has many superior characteristics in high power applications. Paralleling the SiC devices is an effective approach to increase the current capacity of the system, which also leads to current sharing issues. In this article, both transient and steady-state current sharing issues are studied for the high-power grid-tied inverters with paralleled SiC modules with an effective current balancing strategy proposed to address both issues simultaneously. The steady-state imbalance current due to the parameter mismatch is suppressed by the self-inductance of power cables used for paralleling connection. With the elimination of steady-state imbalance current, the transient imbalance current sensing is much simplified and can be realized by using low-cost current sensors. With the sensed imbalance current, a closed-loop control approach is proposed to adjust the modulation reference signal for each module to mitigate the remaining transient imbalance current. Furthermore, the proposed method is straightforward to implement with enhanced compatibility and flexibility compared to existing methods. Experimental studies are performed using inverters with 2 and 4 power modules paralleled in each phase to demonstrate the effectiveness of the proposed method.

42 ENGINEERING↗

Magnetic Properties of Cables with Meandering Wires through a Multipole-based Cable Braid Electromagnetic Penetration Model

In this paper, we employ our first principles multipole-based cable braid electromagnetic penetration model to evaluate the transfer inductance of cables exhibiting meandering wires. We concentrate on a cable structure with two wires, and consider the dependence on the transfer inductance as a function of braid angle and amplitude of the meandering. We compare the results from the first principles model to analytical estimations, confirming the accuracy and correctness of our model. In turn, this makes the multipole-based model readily available for the modeling of realistic cable geometries by accounting for the full dependence on the actual cable geometry.

36 MATERIALS SCIENCE↗

Electron and proton conductivity of Fe-N-C cathodes for PEM fuel cells: A model-based electrochemical impedance spectroscopy measurement

Impedance spectra of a PEM fuel cell with three Fe-N-C cathodes have been measured under the H 2 /N 2 testing regime. The spectra have been fitted using a recently developed physics-based impedance model, which takes into account finite proton ($σ_p$) and electron ($σ_e$) conductivity of the oxygen-free cathode catalyst layer. Fitting allowed to extract numerical data for $σ_p$, $σ_e$, the double layer capacitance, and the inductance of cables used for measuring impedance spectra. The values of σp and σe are close to what previously found for standard Pt/C electrodes, which is found for the first time using PGM-free catalysts. The method enables simultaneous measurement of reference proton and electron conductivity of PEMFC cathode.

25 ENERGY STORAGE↗

Evaluation of Damage in Medium Voltage Cable Using Machine Learning

Developments in cable test instrumentation coupled with artificial intelligence and machine learning (ML) to aid in interpretation of cable test signals supports the feasibility for automated analysis of reflectometry tests for low voltage power cables. This work seeks to leverage prior ML work and success for low voltage cables to evaluate potential application to medium voltage (2kV to 10kV) installations. The Accelerated and Real-Time Environmental Nodal Assessment (ARENA) Cable Motor Test Bed at Pacific Northwest National Laboratory (PNNL) was used to test a medium voltage cable with several types of damage including thermal aging and low resistance conductor-to-shield faults. The cable was tested using an inductive clamshell coupler to protect the test instruments from the energized cable voltages that would damage the test instruments if coupled directly to the energized conductor.

42 ENGINEERING↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Width-bending characteristic of REBCO HTS tape and flat-tape Rutherford-type cabling

Abstract The width-bending behaviors for a rare earth barium copper oxide (REBCO) high-temperature superconducting (HTS) tape have been investigated. It has been found experimentally that the width-bending strain of a Yttrium Barium Copper Oxide (YBCO) tape does not degrade the critical current as much as is expected from the axial strain. The critical current is not directly affected by the width-bending strain but by the axial strain, which the width-bending strain generates by the Poisson effect. Since Poisson’s ratio is about 0.3, the axial strain effective on the critical current is about 30% of the width-bending strain. Therefore, the width-bending strain of even 1.5% degrades the critical current by only 15% if the REBCO layer side is bent inward. However, the critical current degraded by more than 70% when the REBCO layer is outward. The width-bending effects on the critical current have been further examined, considering Poisson’s ratio changes and the neutral plane shift of the REBCO tape substrate. Those changes would occur when the material yields due to severe width-bending. Based on the width-bending of REBCO tapes, flat-tape Rutherford-type cabling is discussed. A REBCO Rutherford-type cable can provide various advantages, especially for narrow-tape cabling. The flat-tape Rutherford-type cable has better characteristics against an electromagnetic transverse Lorentz force. Furthermore, the tape length of the cable can be approximately the same as the cable length allowing for excellent tape usage. REBCO Rutherford-type cabling will be a promising high-current, high-field cabling method using thin substrate REBCO tapes. It will be useful for AC ramp-field and pulse-field applications with low AC losses and low shield currents. It notes that the filaments in the cable are symmetrically distributed in parallel. Therefore, each filament’s inductance is uniform, and a uniform current distribution among the filaments can be obtained.

Physics↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

SMART conductor on round core (CORC ® ) wire via integrated optical fibers

Superconducting cables based on high temperature superconductors (HTS) are necessary for applications requiring large currents and low inductance, such as compact fusion reactors. In this paper, we report the proof-of-concept of a SMART Conductor on Round Core (CORC ® ) wire realized via integration of optical fibers into the copper core. A SMART CORC ® wire with integrated optical fibers was manufactured and its capabilities have been experimentally demonstrated. Results show that by interrogating the optical fibers via Rayleigh backscattering, a Spectral Shift signal as a function of time and position along the cable can be used to detect and locate hot-spots that are developed within the wire or its terminations. It has been found that highly localized current injection into the terminations could initiate hot-spots within the cable at locations where current redistribution between tapes occur. This effect is virtually eliminated when adequate current connections are used that inject current evenly along the cable terminations. Normal zone propagation velocities have been calculated as a function of time using Spectral Shift data for a heater-induced quench as well as a quench induced by overcurrent. In both cases the normal zone propagation velocity was about 6 cm s -1 , but in the heater-induced experiment it was preceded by 500 ms of slower propagation at 2.5 cm s -1 .

Physics↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off system, which is the mechanism by which the energy absorbed by the prime mover is transformed into usable electrical energy. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency), and devices will see a sinusoidal varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled power take-offs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the Reference Model Project sponsored by the U.S. Department of Energy. The Reference Model Project was a partnered effort to develop open-source marine energy point designs as reference models to benchmark marine energy technology performance and costs, methods for design and analysis of marine energy technologies, estimations for capital costs, operational costs, and levelized cost of energy. The results from this study show torque is directly related to (1) the physical size of the machine required to increase the air-gap sheer stresses, (2)the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both capital and operational expenditures. This paper aims to be a critical benchmark in helping determine an "optimal" nameplate rating for wave energy devices and their associated power take-offs. With an optimized rating and sizing process, WEC costs can be reduced and overall performance can be improved.

cables↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters: Preprint

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.