Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacitor placement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Convex quadratic relaxations for mixed-integer nonlinear programs in power systems

Here, this paper presents a set of new convex quadratic relaxations for nonlinear and mixed-integer nonlinear programs arising in power systems. The considered models are motivated by hybrid discrete/continuous applications where existing approximations do not provide optimality guarantees. The new relaxations offer computational efficiency along with minimal optimality gaps, providing an interesting alternative to state-of-the-art semidefinite programming relaxations. Finally, three case studies in optimal power flow, optimal transmission switching and capacitor placement demonstrate the benefits of the new relaxations.

42 ENGINEERING↗

Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter

The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active neutral point clamped (ANPC) converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic canceling effect, and DC-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. The results match with each other, and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.

Gui, Handong↗

Methodology of Low Inductance Busbar Design for Three-Level Converters

Three-level (3L) converters are more susceptible to parasitics compared with two-level converters because of their complicated structure with multiple switching loops. In this article, the methodology of busbar layout design for 3L converters based on the magnetic cancellation effect is presented. The methodology can fit for 3L converters with symmetric and asymmetric configurations. A detailed design example is provided for a high-power 3L-active neutral point clamped (ANPC) converter, which includes the module selection, busbar layout, and dc-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. Furthermore, the results match with each other, and the inductances of short and long loops are 6.5 and 17.5 nH, respectively, which are significantly lower than the busbars of NPC-type converters in other references.

42 ENGINEERING↗

Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter

The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active natural clamped converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic cancelling effect, and DC-link capacitor placement. The loop inductance of the designed busbar is verified with simulation, impedance measurements and converter experiment. The results can match with each other and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.

SiC MOSFET↗

Optimal Capacitor Bank Capacity and Placement in Distribution Systems with High Distributed Solar Power Penetration

Capacitor banks have been generally installed and utilized to support distribution voltage during period of higher load or on longer, higher impedance, feeders. Installations of distributed energy resources in distribution systems are rapidly increasing, and many of these generation resources have variable and uncertain power output. These generators can significantly change the voltage profile across a feeder, and therefore when a new capacitor bank is needed analysis of optimal capacity and location of the capacitor bank is required. In this paper, we model a particular distribution system including essential equipment. An optimization method is adopted to determine the best capacity and location sets of the newly installed capacitor banks, in the presence of distributed solar power generation. Finally we analyze the optimal capacitor banks configuration through the optimization and simulation results.

14 SOLAR ENERGY↗

Estimation, Minimization, and Validation of Commutation Loop Inductance for a 135-kW SiC EV Traction Inverter

With growing interests in low inductance SiC based power module packaging, it is vital to focus on system level design aspects to facilitate easy integration of the modules and reap system level benefits. To effectively utilize the low inductance modules, busbar and interconnects should also be designed with low stray inductances. A wholistic investigation of the flux path and flux cancellations in the module-busbar assembly which as differentially coupled series inductors is thus mandatory for a system level design. This work presents a busbar design which can be adopted to effectively integrate the CREE’s low inductance 1.2 kV/1.7 kV SiC power modules. The paper also proposes a novel measurement technique to measure the inductance of the modulebusbar assembly as a whole rather than deducing it from individual components. The inductance of the overall commutation loop of the inverter which encompasses the SiC power module, interconnects and PCB busbar have been estimated using finite element analysis (FEA). Furthermore, insights gained from FEA provided the guidelines to decide on the placement of the decoupling capacitors in the busbar to minimize the overall commutation loop inductance from 12.8 nH to 7.4 nH which resulted in significant reduction in the device voltage overshoot. The simulation results have been validated through measurements using an impedance analyzer with less than 5% difference between extracted loop inductance from FEA and measurements. The bus bar design study and the measurement technique discussed in this paper, can be easily extended to other power module packages. Finally, the 135 kW inverter has been compared to a similar highpower inverter utilizing a laminated busbar to highlight the performance of the former.

42 ENGINEERING↗

A Data-Driven Approach to Dynamic Var Compensator Placement for Local Voltage Stabilization on Feeders with High PV Penetration

Distribution feeders with a high penetration of distributed photovoltaic (PV) systems can experience voltage variability caused by the changing load flow injections corresponding to the availability of the solar resource. The rapid, uncontrolled voltage range fluctuations can affect the system. Tap-changing voltage regulators, switched capacitors, and smart inverter functions have been used to stabilize voltage. However, in some cases, when these options are insufficient or unavailable, dedicated reactive power control devices such as dynamic var compensators (DVCs) can be used for local voltage stabilization. This paper introduces a statistical framework to characterize voltage variability and stabilization, proposes a data-driven approach to DVC placement, and presents the results of a planning study on a real feeder using real data.

Reiman, Andrew P.↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stacked-Die SiC Half-Bridge Module with Minimum Loop Inductance

Minimizing parasitic inductance of power modules is needed to advance their electrical performance. Innovation in the past decade has driven down the inductance of SiC half-bridge power modules to around 1–2 nH by using multilayer, embedded, and hybrid structures. Further reduction becomes difficult, mainly limited by the excessive interconnects required for the planar placement of vertical conducting chips. To address this, a vertically stacked-die approach is proposed in this paper, taking advantage of the vertical conducting nature of the SiC chips. With ceramic decoupling capacitors integrated, 0.48 nH overall loop inductance is achieved and validated by experimental measurement. This paper also discusses potential approaches to further reduce the inductance.

Ribeiro, Pedro↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal sensor network design for multi-scale, time-varying differential algebraic equation systems: Application to an entrained-flow gasifier refractory brick

An algorithm for optimal sensor network design for multi-scale, time-varying differential algebraic equation systems with non-separable dynamics is presented. As the process is time-varying, an integral normalized posterior error covariance of a multi-scale filter is minimized to obtain the optimal sensor locations. For reducing the computational cost, an adaptive sampling rate approach is considered for the slowly-varying variables. The algorithm is applied to a smart refractory brick with embedded sensors as part of an entrained-flow gasifier. Thermistors and interdigital capacitors are considered as candidate measurement technologies for estimating temperature and slag penetration profile along the gasifier wall. Finally, when the optimal set of sensors obtained from the algorithm is used for estimating temperature and slag penetration profiles in a multi-scale Kalman filter framework, satisfactory estimates are obtained despite high measurement noise and model mismatch.

42 ENGINEERING↗