Search NASA⌕ Search

SEARCH · Search NASA

Results for “Carbon steel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Polymer-derived SiC/C/Al environmental barrier coatings on carbon steel

Carbon steel is a widely used structural material; however, it lacks corrosion resistance in water environments. An alternative approach to overcome this challenge is to implement the deposition of inherently corrosion-resistant ceramic coatings. SiC/C/Al coatings were developed at 700°C, using polycarbosilane in combination with Al and C, which were included as active and passive fillers, respectively. Here, we show that it is necessary to use Al particle sizes below 10 µm for them to function as an active filler below 900°C. Owing to their laminar microstructure, these coatings showed a cohesive delamination with an adhesion strength of 10 MPa. Results demonstrated that these coatings were able to reduce the corrosion of carbon steel in saline water by 99.7%, with corrosion rates of 38.33 mpy for carbon steel, and 0.099 and 0.155 mpy for SiC/C and SiC/C/Al (10 µm) coatings, respectively.

36 MATERIALS SCIENCE↗

Corrosion Resistance of 309L Stainless Steel Claddings on Carbon Steel Produced with Wire-Fed Directed Energy Deposition

Additive manufacturing (AM) tools are capable of applying overlay austenitic stainless steel (SS) claddings to carbon steel components. The benefits of this approach over arc welding include a smaller heat-affected zone, residual stress reduction, and material savings. In particular, wire-directed energy deposition is a suitable technique because of its low material cost and high rate of production compared to other AM methods. However, metallurgical variations in composition, phase fraction, and microsegregation can potentially influence the corrosion behavior of such claddings. In this work, 309L SS is clad on carbon steel substrates and electrochemical methods are used to measure their general and pitting corrosion resistance in simulated marine environments (3.5 wt% NaCl solutions). Two-layer claddings are fabricated with four laser powers to understand the effects of bulk chemical composition, austenite/δ-ferrite phase fractions, and individual phase compositions on corrosion behavior. The two-layer claddings are compared to a single-layer cladding, wrought 304 SS, and the carbon steel substrate for a comprehensive assessment of corrosion performance. The two-layer claddings are remarkably resistant to general corrosion in the 3.5 wt% NaCl environment because of their high Cr content (21.6 wt% to 23.3 wt% Cr). The single-layer cladding exhibits localized corrosion at unmixed Fe-rich peninsulas that originate at the dissimilar metal boundary and protrude into the first cladding layer. All two-layer claddings possess higher pitting corrosion resistance than wrought 304 SS, demonstrating their effectiveness as a corrosion-resistant barrier. Here, the pitting corrosion resistance is superior for claddings made with lower laser powers, due to low dilution and greater δ-ferrite contents.

36 MATERIALS SCIENCE↗

Time-Dependent 600 °C Post-Weld Heat Treatment Response of Laser-Wire-Directed Energy Deposited Austenitic Stainless Steel Claddings on Carbon Steel

Austenitic stainless steel overlay claddings are often used to protect nuclear reactor pressure vessels from corrosion. Arc welding processes are traditionally employed, which require a high heat input to bond the dissimilar metals, creating a large heat-affected zone and high residual stress that demands a lengthy stress-relieving post-weld heat treatment, up to 48 hours. High energy beam (e.g., laser, electron beam) directed energy deposition-based overlay cladding processes show promise for fabricating claddings with superior performance compared to arc welded ones because of their localized heat input; however, their necessity and time of post-weld heat treatment are currently unclear. In this research, we investigate the time dependence of a 600 C stress-relieving post-weld heat treatment of austenitic stainless steel clad on low carbon steel by laser-wire-directed energy deposition, comparing the microstructure and mechanical properties of the as-fabricated condition to 2-, 10-, and 48-hour heat treatment times. Diffusion simulations and microscopy show a gradual carburization of the stainless steel cladding and decarburization of the heat-affected zone/base metal. Nanoindentation testing shows up to a 1.8–2.69 embrittlement in the cladding and a 0.33 to 0.69 softening in the heat-affected zone after the 48-hour post-weld heat treatment. Tensile testing of the cladding composites reveals that increasing post-weld heat treatment time raises clad cracking susceptibility due to intergranular carbide formation and shows that laser-wire-directed energy deposition claddings may not require post-weld heat treatment.

Coating↗

Stainless and carbon steel corrosion in aqueous piperazine at absorber and water wash conditions

Corrosion of carbon steel (C1010) and stainless steels (304, 316L, 430) was measured at absorber and water wash conditions at the bench scale. Corrosion rate decreases with increasing concentration of piperazine (PZ). With more than 0.003 m PZ in solution, carbon steel has acceptable corrosion performance. Corrosion of carbon steel increases with increasing partial pressure of CO2, suggesting loading is another dominant parameter. The effect is more significant for dilute PZ; therefore, untreated flue gas with high CO2 content should be avoided in the water wash. Temperature has a less significant effect than PZ concentration and loading. Carbon steel corrosion increases with increasing flow velocity at both absorber and water wash conditions

Liu, Ching-Ting↗

Outgassing measurements of bare and magnetite-coated low-carbon steel vacuum chambers

The outgassing properties of bare and magnetite-coated AISI 1020 low-carbon steel vacuum chambers were evaluated to establish material selection criteria for extreme high vacuum applications, namely, to explore the possibility of using these materials to build next-generation spin-polarized photoelectron guns. Water outgassing measurements using the throughput method revealed that the magnetite-coated chamber exhibited five times lower outgassing at room temperature prior to baking, but this advantage disappears after 80 °C baking. Hydrogen outgassing measurements demonstrated significant differences after intensive heat treatment: the bare low-carbon steel vacuum chamber achieved a specific outgassing rate of 9.6 × 10 −16 Torr L s −1 cm −2 after 400 °C/50 h bake plus additional heat treatment at lower temperatures, 25 times lower than the magnetite-coated low-carbon steel chamber. Residual gas analysis showed >99% hydrogen composition after heat treatment for both materials, with carbon species below detection limits for bare low-carbon steel versus 0.8% for magnetite-coated surfaces. These measurements indicate that properly conditioned bare low-carbon steel can achieve the <10 −12 Torr pressures required for next-generation spin-polarized photogun applications. In conclusion, the paper includes various analysis techniques intended to explain observed behaviors: isotherm analysis of pump-down plots, Arrhenius analysis of hydrogen outgassing rate data, and residual gas composition tracking.

Adsorption isotherm↗

Effect of impurities on phase transformation and precipitation in a low-carbon steel

Impurity elements have been added to a commercial low carbon steel grade to simulate the levels that could arise as a result of increased scrap recycling during steel production. In this study, continuous cooling transformation (CCT) diagrams were constructed for the steels with varying levels of impurities, and it is shown that impurities suppress the phase transformation across a wide range of cooling rates. It was found that a step was formed in the start temperature curve, separating the reconstructive and displacive transformations. The influence of impurities on both the reconstructive transformation and displacive transformation are discussed. Additionally, Cu precipitates were observed using scanning transmission electron microscopy (STEM) in the highest impurity-containing steel after slow cooling (0.05°C/s), fast cooling (5°C/s) and interrupted cooling. It was found that the precipitation kinetics is in the following order: cementite within the secondary phase and cementite at secondary phase-ferrite interface> ferrite grain boundaries> ferrite grain matrix. Atom-probe tomography (APT) revealed Cu precipitates formed on the surface of cementite lamellae, but not within it. This work offers insights for the phase transformation control and precipitation regulation during the thermomechanical processing of low carbon steels containing impurity elements due to scrap recycling.

36 MATERIALS SCIENCE↗

A Laboratory Corrosion Inhibition Study of Carbon Steel Using 2-Mercaptobenzothiazole (MBT) Under Post-Combustion CO2 Capture Conditions

Corrosion mitigation is an important aspect of amine-based post-combustion carbon dioxide (CO2) capture operations due to the desire to use less expensive but corrosion-vulnerable materials such as low carbon steels in the construction of a capture system. In this study, the corrosion behavior of A106 (grade B) carbon steel with an in-house proprietary amine-based solvent was investigated in a laboratory environment at 80°C using an organic corrosion inhibitor, 2-mercaptobenzothiazole (MBT). The corrosion inhibition mechanism was interpreted by electrochemical methods and surface analyses. The results revealed that the corrosion rates of carbon steel were significantly retarded using MBT. The critical inhibitor concentration was determined to be lie between 10 ppm and 50 ppm under the tested conditions.

Materials Science↗

Achieving clean production with nanostructured coated milling tools dry machining low carbon steel

The advancement of clean production using nanostructured materials in subtractive manufacturing processes has focused on replacing the use of liquid lubrication with solid lubricants coated to conventional cutting tools machining low carbon steel (~ 0.2 wt. % carbon). However, little is known about the wear mechanisms that dominate such tools when coated with functional graded nanostructured coatings. The present study follows an international standard for characterizing such wear (ISO 8688) but uses advanced measurement techniques such as x-ray fluorescence technology to measure the diffusion of chemical species from tool to workpiece and vice versa, that contributes to tool wear with the view to enhance the principles of cleaner production. The results show that when commercially-available tools coated with the appropriate functionally graded industrial coating, diffusion does not take place and creates an effective chemical barrier during machining. The experimental methods used in the study include machining workpieces using a CNC milling machine, tachometer for measuring spindle speed, dynamometer for measuring cutting forces, infra-red camera for measuring cutting temperatures, chemical species diffusion wear using x-ray florescence detector, and an optical microscope for measuring tool wear. Coupled with the physical measurement of wear, it is concluded that mechanical wear dominates the milling of a low carbon steel and that thermal properties of the coatings do not correlate with such wear. It is also concluded that flank wear as a function of volume of workpiece removed and machining duration (machining index) is a sound method for assessing the transition of the stages of wear during clean machining operations. The present study not only has implication for the design of better cutting tools, but also advances dry machining processes that eliminate the use of liquid lubricants making subtractive production processes cleaner. The main conclusions drawn from this study show that coated tools have a longer life under dry conditions compared to uncoated tools and that there is no correlation between coating properties and tool wear. In conclusion, diffusion of chemical species into the cut chips did not occur because of the lack of thermally induced chemical wear of the cutting tool and that wear is caused by the gradual erosion of the flank face due to the chip abrading the cutting tool.

36 MATERIALS SCIENCE↗

Failure Strain and Related Triaxiality of Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 Metals, Part I: Experimental Investigation

The objective of this study is to develop failure-limit material models for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals, based on parameters of plastic equivalent strain (failure strain) and stress triaxiality. The research is conducted in two parts. This paper presents Part One of the study. In Part One, custom-designed test specimens undergo controlled uniaxial tension and compression testing at ambient temperature. These tests are performed at quasi-static speeds using Universal Testing Machines (UTMs) in accordance with ASTM E8 and ASTM E9 standards. Experimental data, specifically engineering stress–strain and force–displacement curves, are recorded from the onset of loading until specimen fracture, or in the case of compression tests, until the capacity of the testing machine is reached. In Part Two, the emphasis shifts to the calibration of Finite Element Analysis (FEA) models of the custom-designed test specimens. Plastic equivalent strain and the corresponding stress triaxiality values at failure are extracted from each test specimen for the given metal. These values are then systematically plotted onto a single graph to construct the failure-limit curve, which delineates the boundary conditions for material failure. This approach will facilitate the development of a comprehensive material property definition that correlates plastic equivalent strain with stress triaxiality at failure for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals.

Harwell, Ron↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Galvanic Corrosion of Carbon Steel and Stainless Steel Couples: Effects of γ-Radiation and Solution Environment - 20348

Galvanic corrosion between carbon steel (CS) and stainless steel (SS) in different aqueous environments was investigated using a combination of electrochemical measurements and surface characterizations. In a basic environment (pH 10.6), the galvanic effect is negligible due to the high corrosion resistance of both alloys. In an acidic to near neutral environment (pH 6.0), the galvanic effect is more significant. Coupling to SS, increasing temperature, and irradiation at this pH have a synergistic effect on the corrosion progression of CS, and their effects vary with time. Initially, the oxidation rate of CS increases after galvanic coupling to SS. Increasing temperature or applying γ-radiation accelerates this oxidation process. However, at a longer time when the saturation limits of metal cations are reached, they also lead to the formation and growth of oxides on CS at a much faster rate, resulting in the suppression of the subsequent Fe dissolution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion of Stainless and Carbon Steel in Aqueous Piperazine for CO2 Capture

Current obstacles that prevent commercial implementation of amine-scrubbing CO2 capture are the high costs. Reducing capital costs by appropriate selection of construction materials, which requires knowledge of material corrosion performance for the process, will improve the economic feasibility of this technology. Corrosion was evaluated in three pilot plant campaigns using aqueous piperazine with the Advanced Stripper (PZAS). 316L stainless steel (SS) experienced higher corrosion than 304 SS and 2205 duplex SS, and the corrosion rate showed strong dependence on the temperature. 304 and 2205 performed well at all locations and should be good construction materials for PZAS. Degraded PZ exacerbated 316L corrosion, and removal of PZ degradation products using a carbon adsorption bed significantly reduced corrosion. Carbon steel (CS) corrosion showed a weak temperature effect because the corrosion was more dependent on the protective siderite film. The protectiveness of the films was related to fluid velocity. Ni-based alloys corroded in PZ, and the rate increased with temperature. Corrosion of C1010 CS and SS (304, 316L, 430) was measured at absorber and water wash conditions on the bench-scale. Corrosion rate decreases with increasing PZ. 8 With more than 0.003 m PZ in solution, CS has acceptable corrosion performance. Corrosion of CS increases with increasing partial pressure of CO2, suggesting loading is another dominant parameter for carbon steel corrosion. Temperature has a less significant effect than PZ concentration and loading. CS corrosion increases with increasing flow velocity at both absorber and water wash conditions. SS had little corrosion at this lower temperature. Performance of siderite (FeCO3) protective films on CS was studied at representative stripper conditions on the bench-scale. Siderite films can deposit on the surface of CS in CO2-loaded PZ solution at temperatures >100 °C and protect CS from corrosion. The protection may fail in degraded PZ. Ethylenediamine (EDA) is one of the major contributors for the loss of film protectiveness or can be the surrogate for the effect of PZ degradation on siderite film protection. A link between protectiveness and the apparent density of siderite films was discovered. The apparent density of siderite films decreases with increasing flow velocity and decreasing CO2 loading, resulting in higher corrosion of CS.

Liu, Ching-Ting↗

Self-re-adhering alkali-activated cement composite and its ability to mitigate corrosion of carbon steel in 300 °C hydrothermal environment

Cement-steel interface is a weak point of cement sheath integrity under the environments of high-temperature geothermal wells. This paper presents carbon steel (CS) adherence behaviors of 300 °C-autoclaved alkali-activated Calcium-Aluminate-Cement (CAC)/fly ash F (FAF) (Thermal Shock Resistant Cement, TSRC), granulated blast furnace slag (GBFS)/SiO 2 , and Ordinary Portland Cement (OPC)/SiO 2 blends. The composites’ ability to preserve the bond under the conditions of thermal shock (TS) and strong acid attack (pH 0.6 H 2 SO 4 /brine at 90 °C) as well as their ability to recover the damaged bond and provide steel corrosion protection after additional short-time 5-day curing at 300 °C were evaluated. GBFS/SiO 2 sheath underwent catastrophic failure in the first TS cycle; OPC/SiO 2 lost 78 % and TSRC 51 % of the bond strength in 6 cycles. Only TSRC-CS bond survived 30 days of strong acid exposure; OPC/SiO 2 bond failed after 18 days and GBFS/SiO 2 after 20 days. Addition of micro-glass fibers (MGF) to TSRC further improved its bond strength and CS corrosion protection. Samples of TSRC-CS cured for 30 days at 300 °C before the bond damage recovered 49 % of the damaged bond strength after additional short-time curing. The CS protected by the re-adhered TSRC showed low corrosion rate of 0.13 mm/year (TSRC-MGF), 0.2 mm/year (TSRC) vs. 0.64 mm/year for OPC/SiO 2 protected CS.

15 GEOTHERMAL ENERGY↗

The Evaluation of Chemical Decontamination for Contaminated Carbon Steel Scrap by Multiphase Treatment Process - 20249

There is a significant growth in the field of decommissioning of nuclear facilities due the fact that for a lot of them their end of life is nearing. In Taiwan, the government plans to steadily reduce the dependence on nuclear power and moves gradually towards a nuclear-free homeland. Therefore, the development of decommissioning technology becomes the significant issue for the next coming years. The decommissioning of a nuclear power plant is a long process and practical work including radiological surveys, decontamination, dismantling, and the subsequent waste management. Chemical decontamination is an important task in the decommissioning of nuclear power plants and is usually performed by circulating the chemical solution in selected systems or full systems in order to reduce dose levels. However, the decontamination of segmented metal parts is also considered to reduce the contamination to such levels that they may be disposed of at a lower classification or be unconditionally released, and it helps to achieve the goal of waste minimization and provide a more economical cost for disposal management. Chemical decontamination technology is used to remove the contaminated oxides deposited on the surface of metals by dissolving them with chemical mechanisms, such as chelation, acidic or alkaline dissolution, redox reaction and so on. Carbon steel is the major material used in systems and pipelines in the nuclear power plant, thus it is also commonly selected as the target to be decontaminated in the decommissioning process. In this study, the effectiveness of chemical decontamination is evaluated by using multiphase treatment process including the reduction and the oxidation steps. In the step of redox reaction, the oxidation state of the substance is very important. Especially metals of some oxidation states show solubility in water, which has a decisive influence on the chemical decontamination. The experiment of decontamination of metal scraps is carried out by the immersion method within a chemical solution. The relative operation parameters such as temperature, pH, and concentration of the chemical solution are recorded to demonstrate the effect of the decontamination process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗