Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cardiac flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Time-periodic steady-state solution of fluid-structure interaction and cardiac flow problems through multigrid-reduction-in-time

In this study, a time-periodic MGRIT algorithm is proposed as a means to reduce the time-to-solution of numerical algorithms by exploiting the time periodicity inherent to many applications in science and engineering. The time-periodic MGRIT algorithm is applied to a variety of linear and nonlinear single- and multiphysics problems that are periodic-in-time. It is demonstrated that the proposed parallel-in-time algorithm can obtain the same time-periodic steady-state solution as sequential time-stepping. It is shown that the required number of MGRIT iterations can be estimated a priori and that the new MGRIT variant can significantly and consistently reduce the time-to-solution compared to sequential time-stepping, irrespective of the number of dimensions, linear or nonlinear PDE models, single-physics or coupled problems and the employed computing resources. The numerical experiments demonstrate that the time-periodic MGRIT algorithm enables a greater level of parallelism yielding faster turnaround, and thus, facilitating more complex and more realistic problems to be solved.

97 MATHEMATICS AND COMPUTING↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Determining the impacts of venoarterial extracorporeal membrane oxygenation on cerebral oxygenation using a one-dimensional blood flow simulator

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a mechanical system that provides rapid and short-term support for patients with cardiac failure. In many patients, pulmonary function is also impaired, resulting in poorly-oxygenated cardiac outflow competing against well-oxygenated VA-ECMO outflow, a condition known as North-South syndrome. North-South syndrome is a primary concern because of its potential to cause cerebral hypoxia, which has a critical influence on neurological complications often seen in this patient population. In order to reduce ischemic neurological complications, it is important to understand how clinical decisions regarding VA-ECMO parameters influence blood oxygenation. In our work, we studied the impacts of flow rate and cannulation site on oxygenation using a one-dimensional (1D) model to simulate blood flow. Our model was initially tested by comparing blood flow results to those observed from experimental work in VA-ECMO patients. The 1D model was combined with a two-phase flow model to simulate oxygenation. Additionally, the influence of various other clinician-tunable parameters on oxygenation in the common carotid arteries (CCAs) were tested, including, blood viscosity, cannula position within the insertion artery, heart rate, and systemic vascular resistance (SVR), as well as geometrical changes such as arterial radius and length. Our results indicated that blood oxygenation to the brain strongly depended on the cannula insertion site and the VA-ECMO flow rate with a weaker but potentially significant dependence on arterial radius. During femoral cannulation, VA-ECMO flow rates greater than ~4.9 L/min were needed to perfuse the CCAs. However, axillary and central cannulation began to perfuse the CCAs at significantly lower flow (~1 L/min). These results may help explain the incidence of cerebral hypoxia in this patient population and the common need to change cannulation strategies during treatment to address this clinical problem. While this work describes patient-averaged results, determining these relationships between VA-ECMO parameters and cerebral hypoxia is an important step towards future work to develop patient-specific models that clinicians can use to improve outcomes.

1D blood flow↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗