Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cascading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Kinetic Monte Carlo Approach for Simulating Cascading Transmission Line Failure

In this work, cascading transmission line failures are studied through a dynamical model of the power system operating under fixed conditions. The power grid is modeled as a stochastic dynamical system where first-principles electromechanical dynamics are excited by small Gaussian disturbances in demand and generation around a specified operating point. In this context, a single line failure is interpreted in a large deviation context as a first escape event across a surface in phase space defined by line security constraints. The resulting system of stochastic differential equations admits a transverse decomposition of the drift, which leads to considerable simplification in evaluating the quasipotential (rate function) and, consequently, computation of exit rates. Tractable expressions for the rate of transmission line failure in a restricted network are derived from large deviation theory arguments and validated against numerical simulations. Extensions to realistic settings are considered, and individual line failure models are aggregated into a Markov model of cascading failure inspired by chemical kinetics. Cascades are generated by traversing a graph composed of weighted edges representing transitions to degraded network topologies. Numerical results indicate that the Markov model can produce cascades with qualitative power-law properties similar to those observed in empirical cascades.

Kinetic Monte Carlo, rare events, Cascading Failur↗

Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Highly cascaded first-order sapphire optical fiber Bragg gratings fabricated by a femtosecond laser

This Letter reports an innovative technique for fabricating large-scale, highly cascaded first-order sapphire optical fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method. For the first time, to the best of our knowledge, this study successfully demonstrates a distributed array of 10 FBGs within highly multimode sapphire crystal fiber, made possible by employing a high-power laser technique to generate larger reflectors with a Gaussian intensity profile. These first-order FBGs offer advantages such as enhanced reflectivity, shorter fabrication time, and simplified spectral characteristics, making them easier to interpret compared with high-order FBGs. The FBGs’ resilience and effectiveness are analyzed by subjecting them to temperature tests, proving their capacity for accurate temperature monitoring up to 1500°C—a testament to their suitability for harsh environments. This novel approach broadens the scope for sensing and communication applications in sapphire fibers, particularly under challenging conditions. The novelty of our work lies in successfully overcoming the limitations of previous designs by integrating a cascade of 10 FBGs in sapphire fibers, thereby enhancing multiplexing capabilities, minimizing overlapping of FBG peaks, and ensuring reliable temperature monitoring in industries and applications with thermal gradients.

47 OTHER INSTRUMENTATION↗

Experimental determination of unsteady blade element aerodynamics in cascades. Volume 1: Torsion mode cascade

A two dimensional cascade of harmonically oscillating airfoils was designed to model a near tip section from a rotor which was known to have experienced supersonic torsional flutter. This five bladed cascade had a solidity of 1.17 and a setting angle of 1.07 rad. Graphite epoxy airfoils were fabricated to achieve the realistically high reduced frequency level of 0.44. The cascade was tested over a range of static pressure ratios approximating the blade element operating conditions of the rotor along a constant speed line which penetrated the flutter boundary. The time-steady and time-unsteady flow field surrounding the center cascade airfoil were investigated. The effects of reduced solidity and decreased setting angle on the flow field were also evaluated.

Riffel, R. E.↗

Experimental determination of unsteady blade element aerodynamics in cascades. Volume 2: Translation mode cascade

A two dimensional cascade of harmonically oscillating airfoils was designed to model a near tip section from a rotor which was known to have experienced supersonic translational model flutter. This five bladed cascade had a solidity of 1.52 and a setting angle of 0.90 rad. Unique graphite epoxy airfoils were fabricated to achieve the realistic high reduced frequency level of 0.15. The cascade was tested over a range of static pressure ratios approximating the blade element operating conditions of the rotor along a constant speed line which penetrated the flutter boundary. The time steady and time unsteady flow field surrounding the center cascade airfoil were investigated.

Riffel, R. E.↗

Numerical prediction of wakes in cascades and compressor rotors including the effects of mixing. I - Cascade wakes including the effects of incidence and freestream turbulence

The results of a numerical investigation to predict the flow in the wake regions of compressor cascades, and wakes and mixing in rotors are presented. Attention is given to the flow in compressor cascades including the effects of change in loading (incidence) and the inlet freestream turbulence intensity. The numerical analysis shows a slight increase in the total pressure loss coefficient through the cascade with increasing turbulence levels.

Lakshminarayana, B.↗

Application of a Channel Design Method to High-Solidity Cascades and Tests of an Impulse Cascade with 90 Degrees of Turning

A technique is developed for the application of a channel design method to the design of high-solidity cascades with prescribed velocity distributions as a function of arc length along the blade-element profile. The technique is applied to both incompressible and subsonic compressible, nonviscous, irrotational fluid motion. For compressible flow, the ratio of specific heats is assumed equal to -1.0. An impulse cascade with 90 degree turning was designed for incompressible flow and was tested at the design angle of attack over a range of downstream Mach number from 0.2 to coke flow. To achieve good efficiency, the cascade was designed for prescribed velocities and maximum blade loading according to limitations imposed by considerations of boundary-layer separation.

Stanitz, John D↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

Decentralized Carrier Interleaving in Cascaded Multilevel DC-AC Converters: Preprint

Cascaded dc-ac converters with interleaved carriers are commonly used in applications where elevated voltages and low-distortion multilevel waveforms are needed. Example applications include modular multilevel converters and solid-state transformers. In such systems, carrier interleaving is generally achieved via communication among the stacked converters or a centralized controller. Due to the large number of converters in such a system, existing approaches entail significant wiring complexity and communication may limit resilience to failures. In this paper, we introduce a control strategy which achieves communication-free carrier interleaving among series-connected converters. The proposed controller is embedded within each converter control loop and only requires measurements available at each set of converter terminals. We formulate a dynamic system model and show that the system converges to the interleaved condition irrespective of the number of converters in the stack. After outlining a practical method for digital implementation, experiments are shown on a hardware-in-the-loop setup.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of electron-phonon coupling and electronic thermal conductivity in high energy molecular dynamics simulations of irradiation cascades in nickel

The two-temperature model has been applied to investigate the effects of the electronic subsystem on 150 keV Ni ion cascades in nickel using molecular dynamics simulation. We explore the effects of the magnitude of the electron-phonon coupling and the electronic thermal conductivity on defect production and cluster formation. It has been found that stronger electron-phonon coupling allows larger and more rapid energy feedback to the atomic subsystem, leading to reduction of number of point defects and suppression of the formation of larger defect clusters. It was observed that larger electronic thermal conductivity results in slightly increased number of point defects and larger size vacancy clusters. The latter takes place because of suppression of point defects recombination in faster cooling areas of initial damage.

Zarkadoula, Eva↗

Cascade Reaction of Ethanol to Butadiene over Ag-Promoted, Silica- or Zeolite-Supported Ta, Y, Pr, or La Oxide Catalysts

Ethanol converts to 1,3-butadiene in the presence of suitable multifunctional catalysts. In this work, Lewis acid cations Ta, Y, Pr, and La were dispersed on amorphous silica or beta zeolite, and after physically mixing with silica-supported Ag nanoparticles, were tested in the cascade reaction of ethanol to butadiene at 573 K. The Lewis acid catalysts were characterized by X-ray fluorescence, N 2 physisorption, scanning transmission electron microscopy (STEM), X-ray diffraction, diffuse reflectance (DR) UV-Vis and X-ray photoelectron spectroscopy. High-resolution STEM images confirmed the small oxide cluster size on the silica support. Results from DR UV-Vis spectroscopy showed zeolite-supported Ta and Pr catalysts had a smaller metal oxide cluster size, relative to their SiO 2 counterparts. X-ray photoelectron spectroscopy confirmed the oxidation state of the cations supported on the zeolite remained the same as that of their SiO 2 -supported analogues. The selectivity of the C 4 coupling products toward butadiene relative to butanol correlated with acid strength of the Lewis acid cations, as evaluated by the 2-propanol decomposition reaction to propene and acetone, with Ta being the most selective. In conclusion, the rate of C-C coupling over the zeolite-supported cations was enhanced by an order of magnitude compared to those cations supported on amorphous SiO 2 .

C-C bond formation↗

Systematic two-dimensional cascade tests. Volume 4: Cascade test data

The data pertaining to the performance characteristics of hydrofoils are presented. The hydrofoils are: (1) double circular arc, (2) multiple circular arc, and (3) slotted doubled circular arc. The experimental data are organized into a systematic presentation format and provided with scale factors and reference values for interpretation. The data include local pressure distributions upstream and downstream of the cascade test section, continuous records from flow angle and total pressure surveys, hydrofoil local pressure distributions, and cavitation data.

Murrin, T. A.↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗