SNM Movement Detection/Radiation Sensors and Advanced Materials Portfolio Review, CdMnTe (CMT) Gamma Ray Detectors

The project goals are: (1) Develop CMT radiation detectors - Demonstrate feasibility (Phase 1 is complete) and Improve material properties and device performance; (2) This project will lead to novel radiation detectors - high detection efficiency, high energy-resolution, ambient-temperature operation, and low production cost; and (3) Such detectors are needed in areas of nonproliferation and national security for detection of SNM. Research highlights are: (1) We achieved our Phase-I goal - Demonstration of CMT detector performance approaching that of CZT detectors; (2) Demonstrated that In-doped CMT is much closer to its anticipated performance as radiation detectors than other alternative materials, TlBr and HgI{sub 2} - Large crystal volumes, 10{sup 10}{Omega}{center_dot}cm, 3 x 10{sup -3}cm{sup 2}/V, and stable response; and (3) Conducted material and device characterization experiments - Detectors: I-V, {mu}{sub e}, ({mu}{tau}){sub e}, internal E fields, energy spectra, and high-resolution x-ray response mapping data and Materials - DLTS, TCT, PL, EPDs, XRD, PCD and IR transmission.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effective surface passivation of CdMnTe materials

Passivation is an important process that reduces surface leakage current and its attendant noise. We treated detector-grade large-volume CdMnTe:In samples with an (NH{sub 4})-based passivant, and compared the results with untreated samples by measuring current-voltage characteristics, surface recombination velocity, Raman spectroscopy, and charge-collection mapping. The leakage current of the passivated CdMnTe (CMT) detectors decreased five to ten times, and surface recombination declined five to six times, depending on the passivation conditions applied. We satisfactorily explained these improvements in detector performance as resulting from different passivation layers that were generated by distinct chemical reactions, as determined by the pH of the passivant.

36 MATERIALS SCIENCE↗

Improving CdMnTe Detector Performance by Adding 2% of Selenium

About 2% of selenium was added to CdMnTe (CMT) to reveal the role of selenium in CMT material used as a gamma-ray detector. The average etch-pit density (EPD) in a typical 2-in CdMnTeSe (CMTS) wafer was measured to be about 8.3×10 3 cm –2 except for the edge regions, and the radial nonuniformity of the bandgap along the wafer was about 2-meV. The typical mobility-lifetime product of electrons and holes was evaluated to be 3.06×10 –3 cm 2 /V and 3.1×10 –4 cm 2 /V, respectively. The energy resolution of the 122-keV photo-peak for a Co-57 radioactive source with a planar CMTS detector was 5.2%, demonstrating a positive effect associated with adding dilute amounts of Se to CMT. Finally, the enhanced detector performance in a planar CMTS detector is attributed to an improved value of hole mobility-lifetime product in CMTS, which mitigates the adverse hole tailing effect found in CdZnTe (CZT) and CMT detectors.

47 OTHER INSTRUMENTATION↗

Detector Performance of Ammonium-Sulfide-Passivated CdZnTe and CdMnTe Materials

Dark currents, including those in the surface and bulk, are the leading source of electronic noise in X-ray and gamma detectors, and are responsible for degrading a detector's energy resolution. The detector material itself determines the bulk leakage current; however, the surface leakage current is controllable by depositing appropriate passivation layers. In previous research, we demonstrated the effectiveness of surface passivation in CZT (CdZnTe) and CMT (CdMnTe) materials using ammonium sulfide and ammonium fluoride. In this research, we measured the effect of such passivation on the surface states of these materials, and on the performances of detectors made from them.

36 MATERIALS SCIENCE↗

IMPROVEMENT OF CdMnTe DETECTOR PERFORMANCE BY MnTe PURIFICATION

Residual impurities in manganese (Mn) are a big obstacle to obtaining high-performance CdMnTe (CMT) X-ray and gamma-ray detectors. Generally, the zone-refining method is an effective way to improve the material's purity. In this work, we purified the MnTe compounds combining the zone-refining method with molten Te, which has a very high solubility for most impurities. We confirmed the improved purity of the material by glow-discharge mass spectrometry (GDMS). We also found that CMT crystals from a multiply-refined MnTe source, grown by the vertical Bridgman method, yielded better performing detectors.

99 GENERAL AND MISCELLANEOUS↗

Effect of chemical etching on the surface roughness of CdZnTe and CdMnTe gamma radiation detectors

Generally, mechanical polishing is performed to diminish the cutting damage followed by chemical etching to remove the remaining damage on crystal surfaces. In this paper, we detail the findings from our study of the effects of various chemical treatments on the roughness of crystal surfaces. We prepared several CdZnTe (CZT) and CdMnTe (CMT) crystals by mechanical polishing with 5 {micro}m and/or lower grits of Al{sub 2}O{sub 3} abrasive papers including final polishing with 0.05-{micro}m particle size alumina powder and then etched them for different periods with a 2%, 5% Bromine-Methanol (B-M) solution, and also with an E-solution (HNO{sub 3}:H{sub 2}O:Cr{sub 2}O{sub 7}). The material removal rate (etching rate) from the crystals was found to be 10 {micro}m, 30 {micro}m, and 15 {micro}m per minute, respectively. The roughness of the resulting surfaces was determined by the Atomic Force Microscopy (AFM) to identify the most efficient surface processing method by combining mechanical and chemical polishing.

36 MATERIALS SCIENCE↗

Defect Levels of Indium-doped CdMnTe Crystals

Using photoluminescence (PL) and current deep-level transient spectroscopy (I-DLTS), we investigated the electronic defects of indium-doped detector-grade CdMnTe:In (CMT:In) crystals grown by the vertical Bridgman method. We similarly analyzed CdZnTe:In (CZT:In) and undoped CdMnTe (CMT) crystals grown under the amount of same level of excess Te and/or indium doping level to detail the fundamental properties of the electronic defect structure more readily. Extended defects, existing in all the samples, were revealed by synchrotron white beam x-ray diffraction topography and scanning electron microscopy. The electronic structure of CMT is very similar to that of CZT, with shallow traps, A-centers, Cd vacancies, deep levels, and Te antisites. The 1.1-eV deep level, revealed by PL in earlier studies of CZT and CdTe, were attributed to dislocation-induced defects. In our I-DLTS measurements, the 1.1-eV traps showed different activation energies with applied bias voltage and an exponential dependence on the trap-filling time, which are typical characteristics of dislocation-induced defects. We propose a new defect-trap model for indium-doped CMT crystals.

36 MATERIALS SCIENCE↗

Post-Growth Annealing of Bridgman-grown CdZnTe and CdMnTe Crystals for Room-temperature Nuclear Radiation Detectors

Bridgman-grown cadmium zinc telluride (CdZnTe or CZT) and cadmium manganese telluride (CdMnTe or CMT) crystals often have Te inclusions that limit their performances as X-ray- and gamma-ray-detectors. We present here the results of post-growth thermal annealing aimed at reducing and eliminating Te inclusions in them. In a 2D analysis, we observed that the sizes of the Te inclusions declined to 92% during a 60-h annealing of CZT at 510 °C under Cd vapor. Further, tellurium inclusions were eliminated completely in CMT samples annealed at 570 °C in Cd vapor for 26 h, whilst their electrical resistivity fell by an order of 10 2 . During the temperature-gradient annealing of CMT at 730 °C and an 18 °C/cm temperature gradient for 18 h in a vacuum of 10 -5 mbar, we observed the diffusion of Te from the sample, causing a reduction in size of the Te inclusions. For CZT samples annealed at 700 °C in a 10 °C/cm temperature gradient, we observed the migration of Te inclusions from a low-temperature region to a high one at 0.022 μm/s. During the temperature-gradient annealing of CZT in a vacuum of 10 -5 mbar at 570 °C and 30 °C/cm for 18 h, some Te inclusions moved toward the high-temperature side of the wafer, while other inclusions of the same size, i.e., 10 µm in diameter, remained in the same position. These results show that the migration, diffusion, and reaction of Te with Cd in the matrix of CZT- and CMT-wafers are complex phenomena that depend on certain conditions.

36 MATERIALS SCIENCE↗

Study of Te Inclusions in CdMnTe Crystals for Nuclear Detector Applications

The concentration, size and spatial distribution of Te inclusions in the bulk of CdMnTe crystals mined from two batches of ingots were studied. An isolated planar layer decorated with Te inclusions was identified in CdMnTe crystals from the second ingot. The internal electric field of a CMT crystal was probed by infrared (IR) imaging employing Pockels electro-optic effect. The effect of an isolated plane of Te inclusions on the internal electric-field distribution within the CdMnTe crystal was studied. Space charge accumulation around the plane of Te inclusions was observed, which was found to be higher when the detector was reverse-biased. The effects of the plane of Te inclusions on the electric-field distribution within the CdMnTe crystal, and the quality of CdMnTe crystals for nuclear detector applications are discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Material and detector properties of cadmium manganese telluride (Cd 1-x Mn x Te) crystals grown by the modified floating-zone method

We demonstrated the material- and radiation-detection properties of cadmium manganese telluride (Cd 1-x Mn x Te; x=0.06), a wide-band-gap semiconductor crystal grown by the modified floating-zone method. We investigated the presence of various bulk defects, such as Te inclusions, twins, and dislocations of several as-grown indium-doped Cd 1-x Mn x Te crystals using different techniques, viz., IR transmission microscopy, and chemical etching. We then fabricated four planar detectors from selected CdMnTe crystals, characterized their electrical properties, and tested their performance as room-temperature X- and gamma-ray detectors. Thus, our experimental results show that CMT crystals grown by the modified floating zone method apparently are free from Te inclusions. However, we still need to optimize our growth parameters to attain high-resistivity, large-volume single-crystal CdMnTe.

36 MATERIALS SCIENCE↗

CdMnTe in X-ray and Gamma-ray Detection: Potential Applications

CdMnTe can be a good candidate for gamma-ray detection because of its wide band-gap, high resistivity, and good electro-transport properties. Further, the ability to grow CMT crystals at relatively low temperatures ensures a high yield for manufacturing detectors with good compositional uniformity and few impurities. Our group at Brookhaven National Laboratory is investigating several CMT crystals, selecting a few of them to make detectors. In this paper, we discuss our initial characterization of these crystals and describe our preliminary results with a gamma-ray source.