Former Central Heat Plant, SWMU 045 Implementation Work Plan Kennedy Space Center, Florida

This Implementation Work Plan (IWP) presents detailed design elements for the air sparging (AS) Interim Measure (IM) design provided in the IM Work Plan (IMWP) within the High Concentration Plume (HCP) at the Former Central Heat Plan (CHP) located at Kennedy Space Center (KSC), Florida. The IMWP presented an approach to implement an AS IM to reduce chlorinated volatile organic compound concentrations to concentrations that facilitate a transition to long-term monitoring. CHP has been designated Solid Waste Management Unit 045 under KSC’s Resource Conservation and Recovery Act Corrective Action Program.

Christopher J Pike↗

Former Central Heat Plant SWMU 045 Year 2 Air Sparge System Performance Monitoring Report

This Air Sparge (AS) Performance Monitoring (PM) Report (PMR) presents Year 2 operation, maintenance, and monitoring (OM&M) activities, PM results, and monitoring well installations supporting the AS Interim Measure (IM) at the Former Central Heat Plant (CHP) at Kennedy Space Center (KSC), Florida. CHP has been designated Solid Waste Management Unit 045 under the KSC Resource Conservation and Recovery Act Corrective Action Program. An AS IM was installed at CHP between 2019 and 2021, which included the installation of an AS system to treat a chlorinated solvent groundwater plume. Contaminants of concern (COCs) identified at CHP for the AS IM include tetrachloroethene (PCE), trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), and vinyl chloride (VC). The completed AS system includes a network of 267 AS wells, which treat approximately 1.3 acres of contaminated groundwater. “Hot” compressor technology is used to treat the source zone, while a “cold” compressor is used to treat two hot spot (HS) areas (HS1 and HS2) and the high concentration plume (HCP). The AS system began operation in June-July 2021 and this document includes Year 2 of operation. The overall runtimes for the AS system for the Year 2 reporting period (October 2022 to September 2023) were approximately 69 percent for the cold trailer and 71 percent for the hot trailer. Air samples and vapor screening results collected during the reporting period showed concentrations less than applicable human health and air emissions permit criteria. Groundwater performance monitoring results show that AS treatment continues to be effective in reducing COC concentrations at CHP. At the shallow interval, COC concentrations were all non-detect, less than, or met their respective State of Florida Groundwater Cleanup Target Levels (GCTLs) at the end of Year 2 in September 2023. In the deep interval, 10 of the 15 PM wells detected COCs greater than their respective GCTLs, with two of these wells also exceeding the Natural Attenuation Default Concentration for VC. Based on Year 2 OM&M and PM results, continued operation of the AS system is required to meet the IM objective. It is therefore recommended to continue with AS IM operations at CHP with the following plan for Year 3.

Kevin Alex Murphy↗

A critical evaluation of semianalytic methods in the study of centrally heated, unresolved, infrared sources

We critically evaluate current methods of analysis in infrared (IR) astronomy and investigate the conditions under which these semianalytic methods are reliable. Specifically we examine the usual assumptions of homogeneities in dust density and temperature, and neglect of opacity effects when applied to internally heated, unresolved IR sources. To accomplish this, a series of radiation transport models for these sources have been constructed. The model results are treated as observed quantities and analyzed to derive the source parameters, using simple semianalytic methods. The discrepancies between the derived and actual model parameters can then be attributed to the limitations of the analysis methods and provide a measure of their reliability. Applying this approach to centrally heated, unresolved IR sources, we have studied in detail the following diagnostic problems: (1) determination of dust mass from monochromatic and integrated luminosities; (2) estimation of dust temperature distribution from color temperatures derived from the flux spectrum; and (3) determination of the empirical grain emissivity law (opacity function) for both continuum and spectral features.

Doty, Steven D.↗

Demonstration of the use of ADAPT to derive predictive maintenance algorithms for the KSC central heat plant

The Avco Data Analysis and Prediction Techniques (ADAPT) were employed to determine laws capable of detecting failures in a heat plant up to three days in advance of the occurrence of the failure. The projected performance of algorithms yielded a detection probability of 90% with false alarm rates of the order of 1 per year for a sample rate of 1 per day with each detection, followed by 3 hourly samplings. This performance was verified on 173 independent test cases. The program also demonstrated diagnostic algorithms and the ability to predict the time of failure to approximately plus or minus 8 hours up to three days in advance of the failure. The ADAPT programs produce simple algorithms which have a unique possibility of a relatively low cost updating procedure. The algorithms were implemented on general purpose computers at Kennedy Space Flight Center and tested against current data.

Hunter, H. E.↗

Report of results of benchmarking survey of central heating operations at NASA centers and various corporations

In recent years, Total Quality Management has swept across the country. Many companies and the Government have started looking at every aspect on how business is done and how money is spent. The idea or goal is to provide a service that is better, faster and cheaper. The first step in this process is to document or measure the process or operation as it stands now. For Lewis Research Center, this report is the first step in the analysis of heating plant operations. This report establishes the original benchmark that can be referred to in the future. The report also provides a comparison to other organization's heating plants to help in the brainstorming of new ideas. The next step is to propose and implement changes that would meet the goals as mentioned above. After the changes have been implemented the measuring process starts over again. This provides for a continuous improvement process.

Hoffman, Thomas R.↗

Analysis of Thermal and Reaction Times for Hydrogen Reduction of Lunar Regolith

System analysis of oxygen production by hydrogen reduction of lunar regolith has shown the importance of the relative time scales for regolith heating and chemical reaction to overall performance. These values determine the sizing and power requirements of the system and also impact the number and operational phasing of reaction chambers. In this paper, a Nusselt number correlation analysis is performed to determine the heat transfer rates and regolith heat up times in a fluidized bed reactor heated by a central heating element (e.g., a resistively heated rod, or a solar concentrator heat pipe). A coupled chemical and transport model has also been developed for the chemical reduction of regolith by a continuous flow of hydrogen. The regolith conversion occurs on the surfaces of and within the regolith particles. Several important quantities are identified as a result of the above analyses. Reactor scale parameters include the void fraction (i.e., the fraction of the reactor volume not occupied by the regolith particles) and the residence time of hydrogen in the reactor. Particle scale quantities include the particle Reynolds number, the Archimedes number, and the time needed for hydrogen to diffuse into the pores of the regolith particles. The analysis is used to determine the heat up and reaction times and its application to NASA s oxygen production system modeling tool is noted.

Hegde, U.↗

Analysis of Thermal and Reaction Times for Hydrogen Reduction of Lunar Regolith

System analysis of oxygen production by hydrogen reduction of lunar regolith has shown the importance of the relative time scales for regolith heating and chemical reaction to overall performance. These values determine the sizing and power requirements of the system and also impact the number and operational phasing of reaction chambers. In this paper, a Nusselt number correlation analysis is performed to determine the heat transfer rates and regolith heat up times in a fluidized bed reactor heated by a central heating element (e.g., a resistively heated rod, or a solar concentrator heat pipe). A coupled chemical and transport model has also been developed for the chemical reduction of regolith by a continuous flow of hydrogen. The regolith conversion occurs on the surfaces of and within the regolith particles. Several important quantities are identified as a result of the above analyses. Reactor scale parameters include the void fraction (i.e., the fraction of the reactor volume not occupied by the regolith particles) and the residence time of hydrogen in the reactor. Particle scale quantities include the particle Reynolds number, the Archimedes number, and the time needed for hydrogen to diffuse into the pores of the regolith particles. The analysis is used to determine the heat up and reaction times and its application to NASA s oxygen production system modeling tool is noted.

Hegde, U.↗

Solar Heating Equipment

Solar Unlimited, Inc.'s suncatcher line includes a variety of solar arrays, derived from NASA's satellite program: water heating only, partial home heating, or water and whole house central heating. Solar Unlimited developed a set of vigorous requirements to avoid problems common to solar heating technologies.

Source record↗

Study of Thermal Control Systems for orbiting power systems

Thermal control system designs were evaluated for the 25 kW power system. Factors considered include long operating life, high reliability, and meteoroid hazards to the space radiator. Based on a cost advantage, the bumpered pumped fluid radiator is recommended for the initial 25 kW power system and intermediate versions up to 50 kW. For advanced power systems with heat rejection rates above 50 kW the lower weight of the advanced heat pipe radiator offsets the higher cost and this design is recommended. The power system payloads heat rejection allocations studies show that a centralized heat rejection system is the most weight and cost effective approach. The thermal interface between the power system and the payloads was addressed and a concept for a contact heat exchanger that eliminates fluid transfer between the power system and the payloads was developed. Finally, a preliminary design of the thermal control system, with emphasis on the radiator and radiator deployment mechanism, is presented.

Howell, H. R.↗

Application of remote thermal scanning to the NASA energy conservation program

Airborne thermal scans of all NASA centers were made during 1975 and 1976. The remotely sensed data were used to identify a variety of heat losses, including those from building roofs and central heating system distribution lines. Thermal imagery from several NASA centers is presented to demonstrate the capability of detecting these heat losses remotely. Many heat loss areas located by the scan data were verified by ground surveys. At this point, at least for such energy-intensive areas, thermal scanning is an excellent means of detecting many possible energy losses.

Bowman, R. L.↗

Nonadiabatic heating of the central plasma sheet at substorm onset

Heating events in the plasma sheet boundary layer and central plasma sheet are found to occur at the onset of expansive phase activity. The main effect is a dramatic increase in plasma temperature, coincident with a partial dipolarization of the magnetic field. Fluxes of energetic particles increase without dispersion during these events which occur at all radial distances up to 23 RE, the apogee of the ISEE spacecraft. A major difference between these heating events and those observed at geosynchronous distances lies in the heating mechanism which is nonadiabatic beyond 10 RE but may be adiabatic closer to earth. The energy required to account for the increase in plasma thermal energy is comparable with that required for Joule heating of the ionosphere. The plasma sheet must be considered as a major sink in the energy balance of a substorm. Lobe magnetic pressures during these events are estimated. Change in lobe pressure are generally not correlated with onsets or intensifications of expansive phase activity.

Huang, C. Y.↗

Infrared studies of the Herbig-Haro object 1-2 region

Far-infrared (50-100 micrometers) photometric mapping and near-infrared spectroscopic mapping of the Herbig-Haro 1-2 region are presented. Both lobes of the double-lobed far-infrared source in this region are found to be nearly coincident with recently discovered radio continuum sources. The dust temperature structure around each peak is not spherically symmetric, suggesting either that the far-infrared sources are centrally heated or that the dust column density is highly nonspherically symmetric. The results are consistent with a picture in which each far-infrared lobe contains a highly obscured young star surrounded by a highly nonspherically symmetric dust cloud. A complementary study by Strom et al. (1985) is pointed out.

Harvey, P. M.↗

Far-infrared continuum emission from the nucleus, starburst, and extended spiral arms of NGC 1068

Far-infrared slit scans across NGC 1068 are used to better define the contribution of the active nucleus, starburst disk, and extended spiral arms in the luminous output of this bright Seyfert 2 galaxy. The decomposition of the emission from the bright, inner 3 kpc of this galaxy suggests that at 50 microns, about half the emission is from star formation in a starburst disk and half from the compact, centrally heated circumnuclear cloud. The 100-micron profile of the starburst disk is asymmetric with respect to the nucleus. This appears to be the result of an extraordinary star-forming complex about a kiloparsec away from the center. With the application of maximum entropy deconvolution to the scans, evidence is found for 100-micron emission from the extended spiral arms of the galaxy. The far-infrared emission from the starburst region is distinguished from that of the extended spiral arms. In terms of both total luminosity and surface brightness, the extended spiral arms of NGC 1068 are at the bright end of the range of far-infrared emission from quiescent, noninteracting spirals.

Lester, D. F.↗

Preliminary design of the Space Station internal thermal control system

The baseline preliminary design configuration of the Internal Thermal Control system (ITCS) of the U.S. Space Station pressurized elements (i.e., the Habitation and U.S. Laboratory modules, pressurized logistics carrier, and resources nodes) is defined. The ITCS is composed of both active and passive components. The subsystems which comprise the ITCS are identified and their functional descriptions are provided. The significant trades and analyses, which were performed during Phase B (i.e., the preliminary design phase) that resulted in the design described herein, are discussed. The ITCS interfaces with the station's central Heat Rejection and Transport System (HRTS), other systems, and externally attached pressurized payloads are described. Requirements on the ITCS with regard to redundancy and experiment support are also addressed.

Herrin, Mark T.↗

Infrared radiative transfer in dense disks around young stars

A two-dimensional radiative transfer program has been used to determine the temperature distribution within cylindrically symmetric, centrally heated dust clouds. In particular, the disk-shaped structures observed around young luminous stars have been modeled. Changing the dust distribution in these disks primarily affected the observed morphology in the near-infrared and far-infrared, and at millimeter wavelengths. The overall cloud spectrum, however, was mainly determined by the characteristics of the grains themselves. Comparison with published far-infrared and molecular line data has indicated that the dust density can generally be modeled by a power-law distribution in r with index of -2 and an exponential in z with disk thickness proportional to 1/r. When observed nearly edge-on, scattered direct stellar radiation is observed in the polar regions in the form of comet-shaped lobes of emission.

Dent, William R. F.↗

Micro-Resistojet for Small Satellites

An efficient micro-resistojet has been developed with thrust in the millinewton level, with a specific impulse of approximately 250 seconds and power input of 20 watts or less that is useful for applications of up to 1,000 hours of operation or more. The essential feature of this invention is a gas-carrying tube surrounding a central heating element. The propellant is flashed into vapor and then passes through a narrow annulus between the tube and the heater where it is cracked (in the case of methanol, into CO and H2) before being discharged through a de Laval nozzle to produce thrust. A multi-layer radiation shield around the gas tube minimizes heat loss. Also, if methanol is used as the propellant, the simultaneous heating and cracking does not need an additional device. This unit would be especially useful for small satellites, with mass up to 100 kg, and for delta v up to 500 m/sec, and is suited for use with green methanol as the propellant where a specific impulse of 220 seconds is expected. Noble metal alloys are the optimal materials of construction. While the microresistojet is especially suited to methanol, many other propellants may be used such as water or, in the case of de-orbiting, many other residual liquids onboard the vehicle.

Brogan, Thomas↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices,Cloud, and Elevation satellite-2) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time-dependent chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three-year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Design↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices, cloud, and elevation satellite) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time depend chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Salem, Jon↗