Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cerenkov detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cerenkov detectors for cosmic ray telescopes employing the Cerenkov x total energy technique of mass identification

Considerable progress has been made regarding the evolution of the 'Cerenkov x total energy technique' for mass identification of cosmic ray nuclei since the introduction of telescopes employing this technique by Webber et al. (1973). Thus, significant improvements in mass resolution have been made. These improvements are mainly related to the resolution of the Cerenkov counter. The present investigation is, therefore, concerned with the properties of various types of Cerenkov detectors. In addition, a description is provided of the characteristics of a large area (approximately 0.5 sq m-ster) cosmic ray isotope telescope, which is being developed for use on balloons or spacecraft.

Webber, W. R.↗

SNM Detection with a Large Water Cerenkov Detector

Special Nuclear Material (SNM) can either spontaneously fission, or be induced to do so. Either case results in neutron emission. Since neutrons are highly penetrating and difficult to shield, they could, potentially, be detected escaping even a well shielded cargo container. Obviously, if the shielding is sophisticated, detecting it would require a highly efficient detector with close to 4{pi} solid angle coverage. Water Cerenkov detectors may be a cost effective way to achieve that goal if it can be shown that the neutron capture signature is large enough and if sufficient background rejection can be employed as detectors get larger. In 2008 the LLNL Advanced Detector Group reported the successful detection of neutrons with a 1/4 ton gadolinium doped water Cerenkov prototype. We have now built a 4 ton version. This detector is not only bigger, it was designed with photon detection efficiency in mind from the beginning. We are employing increased photocathode coverage and more reflective walls, coated with PTFE. The increased efficiency should allow better energy resolution. We expect that the better diffusive wall reflectivity will reduce the overall dependence of the detector response on particle direction, again producing a more consistent response. We also believe that as detectors get larger, both uncorrelated and correlated backgrounds due to gamma-rays and cosmic ray interactions near the detector will increase. To prove the effectiveness of the technology we must develop new ways to reject these backgrounds while maintaining our sensitivity to SNM neutrons. Better energy resolution will enable us to reject more of the low energy gamma-ray backgrounds on this basis. Overcoming cosmic ray induced neutrons is perhaps an even larger concern as detectors get larger. Our detector is designed so that we can test various segmentation schemes - effectively dividing the detector up into smaller ones. In this presentation, we will describe our detector in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Impact of the BLAST Magnetic Field on the Cerenkov Detectors

We report a factor of two improvement to the efficiencies of a large array of diffusely reflective aerogel Cerenkov detectors which were operated near a high magnetic field. This was accomplished by designing additional magnetic shielding. The improvement was studied by observing the ADC spectrum of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n =1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n =1.030, ~8 for n =1.020, ~10 for n =1.015, and ~5.5 for n =1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A threshold gas Cerenkov detector for the spin asymmetries of the nucleon experiment

In this study, we report on the design, construction, commissioning, and performance of a threshold gas Cerenkov counter in an open configuration, which operates in a high luminosity environment and produces a high photo-electron yield. Part of a unique open geometry detector package known as the Big Electron Telescope Array, this Cerenkov counter served to identify scattered electrons and reject produced pions in an inclusive scattering experiment known as the Spin Asymmetries of the Nucleon Experiment E07-003 at the Thomas Jefferson National Accelerator Facility (TJNAF) also known as Jefferson Lab. The experiment consisted of a measurement of double spin asymmetries A || and A ⊥ of a polarized electron beam impinging on a polarized ammonia target. The Cerenkov counter's performance is characterised by a yield of about 20 photoelectrons per electron or positron track. Thanks to this large number of photoelectrons per track, the Cerenkov counter had enough resolution to identify electron-positron pairs from the conversion of photons resulting mainly from π 0 decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for unique identification of relativistic /greater than 0.5/ magnetic monopoles with a fast film Cerenkov detector

A magnetic monopole traversing a dielectric medium at a velocity greater than the phase velocity of light in that medium, will give rise to Cerenkov radiation with the electric field tangent to the cone generated by the photon wave propagation vector, and the magnetic field normal to that surface. This is the opposite polarization to that encountered with an electric charge. It is proposed that either by inserting a linearly polarizing layer between the radiator and the photographic emulsion, or by selecting a linearly polarizing material as the radiator, one could directly observe the field polarization by examining the photographic image and thus uniquely identify a magnetic monopole. The ability of the detector is further enhanced by the index of refraction dependence of the Cerenkov output from a magnetic monopole.

Pinsky, L. S.↗

A Study of Heavy Trans-Iron Primary Cosmic Rays (Z More than or Equal to 55) with a Fast Film Cerenkov Detector

The detection and measurement of the cosmic ray charge spectrum for nuclei heavier than iron (Fe, Z = 26) are discussed. These trans-iron nuclei are of great interest for several reasons. They promise to be one of the more sensitive clocks for use in determining the age of cosmic rays. The discovery of radioactive nuclides and their decay products in the primary flux, will allow an estimation of the elapsed time since these cosmic rays were synthesized. In addition, the relatively short interaction length of the very heavy trans-iron particles makes their relative abundance a source of information regarding the amount of interstellar matter that they had to traverse to reach the earth. A study of the trans-iron cosmic rays may provide clues as to the very processes of nucleosyntheses by which the bulk of the trans-iron nuclei in the universe are produced. This in turn may shed light on the mechanics of the supernova, which is postulated to be the major source of all cosmic rays. Finally, trans-iron cosmic ray experiments may demonstrate the existence of the recently postulated super-heavy nuclei.

Pinsky, L. S.↗

A Cerenkov-delta E-Cerenkov detector for high energy cosmic ray isotopes and an accelerator study of Ar-40 and Fe-56 fragmentation

A high energy cosmic ray detector--the High Energy Isotope Spectrometer Telescope (HEIST) is described. It is a large area (0.25 m(swp 2) SR) balloon borne isotope spectrometer designed to make high resolution measurements of isotopes in the element range from neon to nickel (10 Z 28) at energies of about 2 GeV/nucleon. HEIST determines the mass of individual nuclei by measuring both the change in the Lorentz factor (delta gamma) that results from traversing the NaI stack, and the energy loss (delta E) in the stack. Since the total energy of an isotope is given by E = (gamma M), the mass M can be determined by M = delta E/delta, gamma. The instrument is designed to achieve a typical mass resolution of 0.2 amu. The isotopic composition of the fragments from the breakup of high energy An-40 and Fe-56 nuclei are measured experimentally. Isotope yields are compared with calculated yields based on semi-empirical cross-section formulae.

Lau, K. H.↗

On the interpretation of observed data from C-dE/dx detectors

The paper describes a Cerenkov detector system designed to obtain abundances and energy spectra of cosmic ray nuclei above charge 12 and above 350 MeV/nucleon. The detector system consists of three pulse ionization chambers, a Lucite Cerenkov counter and a plastic scintillation-counter hodoscope. The data analysis follows from the standard dE/dx-C technique. It is shown that by using the relativistic ionization rise, the resolution and pulse height corresponding to charged particles of Beta ? 1 in Cerenkov detectors can be determined. Least-squares-fit procedures are used to obtain area and time variations of detector response from flight data and to extract elemental abundances from data with charge resolution of roughly 0.3 charge units.

Benegas, J. C.↗

High resolution Cherenkov detectors for cosmic ray isotope experiment

Cerenkov detectors are used to measure the velocity of particles in configurations designed to study the isotopic composition of galactic cosmic rays. The geometrical properties of the detector are outlined. Monte-Carlo simulations of photon propagation in a diffusive detector were undertaken. The scattering properties of diffusively reflecting white paint and of surface treatments for the radiator material were measured. It is found that the absorption of light in the radiator is an important light loss mechanism. The simulations are used to find optimal mapping techniques and data reduction strategies. The application of these techniques are discussed with respect to the large area isotopic composition experiment (ALICE) Cerenkov detector.

Acharya, B. S.↗

The energy spectrum of 10-50 BeV/nuc cosmic rays

We have obtained measurements of the energy spectra of cosmic ray nuclei with charge Z equals 5-14 in the 10-50 BeV/nuc energy interval from a gas Cerenkov detector flown aboard a high altitude balloon at Sioux Falls, South Dakota in September, 1974. The gas Cerenkov detector consists of a pressurized light diffusion chamber viewed by two separate banks of photomultiplier tubes. An analysis of the two signals permits a very effective rejection of background events as well as an understanding of the sources of broadening to be removed in the extraction of kinetic energy spectra from the gas Cerenkov detector pulse height distributions. The ratio of secondary to primary nuclei display a decrease with increasing energy as reported by other investigators.

Lezniak, J. A.↗

The Capabilities of the upgraded MIPP experiment with respect to Hypernuclear physics

We describe the state of analysis of the MIPP experiment, its plans to upgrade the experiment and the impact such an upgraded experiment will have on hypernuclear physics. The upgraded MIPP experiment is designed to measure the properties of strong interaction spectra form beams {pi}{sup {+-}}, K{sup {+-}}, and p{sup {+-}}, for momenta ranging from 1 GeV/c to 120 GeV/c. The layout of the apparatus in the data taken so far can be seen in Figure 1. The centerpiece of the experiment is the time projection chamber, which is followed by the time of flight counter, a multi-cell Cerenkov detector and the RICH detector. The TPC can identify charged particles with momenta less than 1 GeV/c using dE/dx, the time of flight will identify particles below approximately 2 GeV/c, the multi-cell Cerenkov detector is operational from 2.5 GeV/c to 14 GeV/c and the RICH detector can identify particles up to 120 GeVc. Following this is an EM and hadronic calorimeter capable of detecting forward going neutrons and photons. The experiment has been busy analyzing its data taken on various nuclei and beam conditions. The table 2 shows the data taken by MIPP I to date. We have almost complete acceptance in the forward hemisphere in the lab using the TPC. The reconstruction capabilities of the TPC can be seen in Figure 3. The particle identification capabilities of the TPC can be seen in Figure 4. The time of flight system provides further measurement of the particles with momenta less than 2 GeV/c. Figure 5 shows the time of flight data where a kaon peak is clearly visible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗