Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cf-252”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new method for using Cf-252 in SEU testing

A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.

Costantine, A.↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Californium-252 neutron capture and decay methods for elemental analysis

The feasibility of using a Cf-252 neutron source in conjunction with a capture and/or decay gamma ray method for elemental analysis on lunar or planetary missions was tested. The general problems of using a Cf-252 neutron source for both decay and capture gamma ray analysis in terrestrial environments included the determination of the capture gamma ray spectra by neutron absorption in various metals used for the space hardware, Cf-252 source encapsulation materials, shielding, geometry, and optimum source size for a space mission. Computer data reduction and data transmission techniques were also investigated.

Source record↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

Shielding Benchmark Comparison - MCNP6.2

This report documents the calculations performed for a shielding code comparison between various Department of Energy (DOE) sites. These shielding calculations were performed using an experiment drawn from the International Handbook of Evaluated Criticality Safety Benchmark Experiments, published by the Organisation for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA). The benchmark selected for comparison is ALARM-CF-AIR-LAB-001 (“Neutron Fields in the Three-Section Concrete Labyrinth from Cf-252 Source, Benchmark ALARM CF AIR LAB-001”). The Y-12 submission for this code comparison was performed with Monte Carlo N Particle (MCNP) Transport Code System, Version 6.2 and Automated Variance Reduction Generator (ADVANTG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

User’s Manual for RESRAD-RDD&IND Code Version 2: Vol. 2—User’s Guide for RESRAD-RDD&IND Code

Version 2.0 of the RESRAD-RDD&IND computer code is designed to support the implementation of protective action guides (PAGs) after a nuclear emergency incident including a radiological dispersal device (RDD) and/or an improvised nuclear device (IND) incident (EPA 2017). Eight different group types, addressing various decisions, are available for selection. The RESRAD-RDD&IND code calculates radiological doses, stay times, etc., for the selected group that the user wishes to focus on. (That is, the results for all the groups are not calculated simultaneously, and the input for those other groups do not matter, although some parameter values are shared between groups.) Version 2.0 has a user-friendly interface so that the RESRAD-RDD&IND code can be used with minimal training. For example, the user can select the major characteristics of the problem-event type, source term, and decision type from the left side of the interface and then calculate the results with the default assumptions for the exposure scenarios. More in-depth analysis would include specifying site-specific exposure scenario characteristics in the right side of the interface. The procedures for data entry and results viewing are self-explanatory. This is because common window maneuvering features and text instructions were incorporated in the interface design. General and context-specific help are available to aid users entering parameter values, as well. The RESRAD-RDD&IND computer code gives the user the option to select either an RDD or IND incident for analysis. For an RDD event analysis, 11 radionuclides (Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90) are included. These 11 radionuclides are the radionuclides most likely used for an RDD. More than 90 radionuclides can be selected for an IND event analysis. Initial default concentrations are provided for 44 radionuclides for a uranium-fueled IND event. These 44 radionuclides are those that would contribute significantly to the radiation dose associated with a uranium-fueled bomb detonation. The radionuclides generated from ingrowth of these 44 initial radionuclides are also automatically included in the analysis. Pu-239, Cs-134m, Ru-105, and Rb-89 and their progeny can be selected for analysis if they are detected and their concentrations are determined. This user’s guide, which is Volume 2 of the User’s Manual for RESRAD-RDD&IND Code Version 2, provides instructions to users on how to install the RESRAD-RDD&IND code, navigate the interface, and use the various features, including those discussed above, to set up an analysis and view/print the results in text outputs. Volume 1 of the User’s Manual for RESRAD-RDD&IND Code Version 2 (Yu et al. 2026), which contains descriptions of the methodology and theoretical basis for dose modeling and the mathematical equations implemented in the code, can be accessed and viewed through the Help menu in the code or can be downloaded from the RESRAD website (https://resrad.evs.anl.gov).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bldg. 7930 Cell G Neutron Detector New Electronics Testing

The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.

Taylor, Neil [Oak Ridge National Laboratory (ORNL)↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Evaluation of radioisotope tracer and activation analysis techniques for contamination monitoring in space environment simulation chambers

Radioisotope measurement techniques and neutron activation analysis are evaluated for use in identifying and locating contamination sources in space environment simulation chambers. The alpha range method allows the determination of total contaminant concentration in vapor state and condensate state. A Cf-252 neutron activation analysis system for detecting oils and greases tagged with stable elements is described. While neutron activation analysis of tagged contaminants offers specificity, an on-site system is extremely costly to implement and provides only marginal detection sensitivity under even the most favorable conditions.

Smathers, J. B.↗

Compositional studies of the lunar regolith at the Apollo 17 site

Major-, minor-, and trace-element abundance data are presented for twenty-two Apollo 17 samples, twelve Apollo 16 samples, and one Apollo 15 basalt. The data were obtained by INAA employing a 14 MeV neutron generator, a Cf-252 isotopic neutron source and nuclear reactor thermal neutrons. Abundance summations for the twenty-four samples analyzed for major and minor abundance elements averaged 98.8 plus or minus 0.3%. Similarities between the Apollo 17 and the Apollo 11 mare basalts are discussed. Abundances in 13 Apollo 17 soils exhibit the greatest compositional range we have observed for soils from a specific landing site. A strong inverse Fe-Al correlation in all lunar materials we have analyzed with the exception of most Apollo 16 samples is defined by the equation: %Fe = -1.36 %Al + 21.5. A strong direct Mn-Fe correlation is defined by the equation: %Fe = 75.9 %Mn + 0.08. Both regression lines appear to have the mare basalts, as one end-member and an unspecified Al-rich component at the other end. Comparisons of the data from direct O determinations and calculated O abundances based on normal stoichiometry are presented.

Miller, M. D.↗

Verification of a SEU model for advanced 1-micron CMOS structures using heavy ions

Modeling and test results are reported for 1 micron CMOS circuits. Analytical predictions are correlated with experimental data, and sensitivities to process and design variations are discussed. Unique features involved in predicting the SEU performance of these devices are described. The results show that the critical charge for upset exhibits a strong dependence on pulse width for very fast devices, and upset predictions must factor in the pulse shape. Acceptable SEU error rates can be achieved for a 1 micron bulk CMOS process. A thin retrograde well provides complete SEU immunity for N channel hits at normal incidence angle. Source interconnect resistance can be important parameter in determining upset rates, and Cf-252 testing can be a valuable tool for cost-effective SEU testing.

Cable, J. S.↗

Segmented Ge detector rejection of internal beta activity produced by neutron irradiation

Future Ge spectrometers flown in space to observe cosmic gamma-ray sources will incorporate segmented detectors to reduce the background from radioactivity produced by energetic particle reactions. To demonstrate the effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity, a laboratory experiment has been carried out in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 (36.5 percent of natural Ge) in the detector itself, Ge-75 (t sub 1/2 = 82.78 min), which decays by beta emission with a maximum electron kinetic energy of 1188 keV. By requiring that an ionizing event deposit energy in two or more of the five segments of the detector, each about 1-cm thick, the beta particles, which have a range of about 1-mm, are rejected, while most external gamma rays incident on the detector are counted. Analysis of this experiment indicates that over 85 percent of the beta events from the decay of Ge-75 are rejected, which is in good agreement with Monte Carlo calculations.

Varnell, L. S.↗