Search NASASearch

SEARCH · Search NASA

Results for “Charge Plate Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASCAP Surface Charging Tool Development - Nascap-2k Additional Examples

This document consists of examples of the use of Nascap-2k to analyze moderately complex interactions between spacecraft surfaces and the plasma environment. The narrative assumes familiarity with the use of Nascap-2k and the field of spacecraft-environment interactions. Specific results may be slightly different from those given here due to small differences in the geometry, material selection, and version of Nascap-2k.

Charge Plate Analyzer

ATS-6 - UCSD auroral particles experiment

The University of California at San Diego Auroral Particles Experiment aboard Applications Technology Satellite-6 (ATS-6) is discussed. The experiment is designed to investigate the time development of geomagnetic substorm particles, the confinement and loss of such particles, and the roles of plasma wave instabilities and characteristic system periodicities in substorm and general magnetospheric processes. The instrumentation includes a complement of five electrostatic charged particle detectors. Two detector assemblies are capable of rotation through 220 deg. The electrostatic curved plate energy/unit charge analyzers are ovoid, requiring particles to be bent only 55 deg to obtain azimuthal focusing. The inside of the plates is serrated to eliminate particles striking the sides. A post-analysis electrostatic lens consisting of two wire grids, one at the potential of the inner plate and one at the potential of ground, focuses particles strongly upon the center of the sensor. A spiraltron particle sensor detects the charged particles. The system has an energy range of five orders of magnitude with a lower extreme of less than 1 eV. Preliminary data are presented to illustrate phenomena which are observed as a result of the novel features described.

Mauk, B. H.

Simulation of a Miniature, Low-Power Time-of-Flight Mass Spectrometer for In Situ Analysis of Planetary Atmospheres

We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (less than 1000 cubic centimeters) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions greater than 600 at sensitivity levels on the order of 10(exp -3) cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions approximately 1000, though at the expense of sensitivity and instrument volume.

King, Todd T.

Improved charged-particle analyzer - A concept

Device utilizes concept that charged-particle analysis is achievable by applying sinusoidal voltage across two conductive deflection plates with predetermined curvature and constant spacing to define selective passageway for charged particles to be analyzed. Four advantages of improved device are cited.

Dimeff, J.

The Pioneer Venus Orbiter plasma analyzer experiment

The plasma analyzer experiment on the Pioneer Venus Orbiter was designed to determine the basic characteristics of the plasma environment of Venus and the nature of the solar wind interaction at Venus. The plasma analyzer experiment is an electrostatic energy-per-unit charge (E/Q) spectrometer which measures ions and electrons. There is a curved plate electrostatic analyzer system with multiple collectors. The experiment obtains the three dimensional plasma distribution function. Some of the scientific objectives of the instrument are briefly discussed, the general characteristics of the experiment are summarized, and some of the analyses based on the data are presented.

Intriligator, D. S.

Physical and chemical analysis of a Ni/H2 cell

A cycled aerospace nickel hydrogen (Ni/H2) cell was subjected to destructive physical analysis to determine the reason for a capacity loss after 5,967 cycles at 60 percent depth of discharge. The positive plates in the cell were analyzed in terms of chemical composition, active material utilization, charge efficiency, and thickness increase. The microstructure of a cross section of the positive plate was determined by backscattered electron image analysis. The results suggest that the capacity loss in the cell is caused by low charge acceptance and low active material utilization at the positive plate. The oxidized nickel species content of the positive plate increased due to corrosion of the nickel sintered skeleton. This appears to circumvent the orderly reaction of the active material. Microstructural analysis has indicated that a new phase of active material is formed with cycling.

H Vaidyanathan

Interstellar Pickup Hydrogen Observations from the Pioneer 10 and 11 Plasma Analyzers

The Pioneer 10 and 11 Ames plasma analyzers included off-angle integrating counters used for the first exploration of magnetospheric plasmas at Jupiter and Saturn. When summed over multi-day intervals during interplanetary cruise, at times of relatively constant solar wind speed during 1972 to 1977, the resulting count rates show a dependence on acceptance energies of the plasma analyzer deflection plates. The count rates could be produced by energetic charged particles, solar wind protons moving at a large angle to the bulk flow, and interstellar pickup ions. We interpret the more energetic of two peaks that are sometimes observed as the signature of interstellar pickup hydrogen. This peak is located at just below twice the solar wind speed (V(sub SW)), when near 3 AU heliocentric distance, decreasing to just above V(sub SW) as the heliocentric distance increases. Also, in the 8 to 12 AU range of heliocentric distances, we identify the pickup hydrogen signature as a shelf that ends at an edge located below 2V(sub SW). During these observations, the spacecraft longitude relative to the upstream interstellar flow changes roughly from 25 deg, to 155 deg at the larger heliocentric distance. The peak at the smaller heliocentric distances is most consistent with a velocity distribution that is a shell in phase space, with limited thickening as the pickup ions are assimilated into the solar wind flow.

Mihalov, J. D.

Controlling Charged Particles with Inhomogeneous Electrostatic Fields

An energy analyzer for a charged-particle spectrometer may include a top deflection plate and a bottom deflection plate. The top and bottom deflection plates may be non-symmetric and configured to generate an inhomogeneous electrostatic field when a voltage is applied to one of the top or bottom deflection plates. In some instances, the top and bottom deflection plates may be L-shaped deflection plates.

Herrero, Federico A.

Effects of variables upon pyrotechnically induced shock response spectra

Throughout the aerospace industry, large variations of 50 percent (6 dB) or more are continually noted for linear shaped charge (LSC) generated shock response spectra (SRS) from flight data (from the exact same location on different flights) and from plate tests (side by side measurements on the same test). A research program was developed to investigate causes of these large SRS variations. A series of ball drop calibration tests to verify calibration of accelerometers and a series of plate tests to investigate charge and assembly variables were performed. The resulting data were analyzed to determine if and to what degree manufacturing and assembly variables, distance from the shock source, data acquisition instrumentation, and shock energy propagation affect the SRS. LSC variables consisted of coreload, standoff, and apex angle. The assembly variable was the torque on the LSC holder. Other variables were distance from source of accelerometers, accelerometer mounting methods, and joint effects. Results indicated that LSC variables did not affect SRS as long as the plate was severed. Accelerometers mounted on mounting blocks showed significantly lower levels above 5000 Hz. Lap joints did not affect SRS levels. The test plate was mounted in an almost free-free state; therefore, distance from the source did not affect the SRS. Several varieties and brands of accelerometers were used, and all but one demonstrated very large variations in SRS.

Smith, J. L.

Interaction of Planar Brushes with End-Functionalized Carboxylic or Amine Groups: Water Structure, Hydrogen Bonds, and Electrostatic Correlations

In this work we present a detailed analysis of two parallel plates grafted with polyethylene glycol (PEG) terminated with carboxylic or amine groups, and discuss the cases of opposite and same charge in the presence of electrolytes. We analyze the screening of charged groups by electrolytes, the role of hydrogen bonds in enhancing attraction or repulsion, hydration forces, competitive binding with counterions, and the hydrogen bond network, crucial to stabilizing the system. Our simulations reveal that, for large plate separation, the system is well described as a “Stern layer”, characterized by strong counterion binding and a subsequent weak diffuse layer. For short plate separation, the system is characterized by strong correlations among end groups and counterions. We also discuss the relevance of charged carboxylic/amine groups in different problems with a particular emphasis on nanoparticle assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Ignition-and-Growth Modeling of NASA Standard Detonator and a Linear Shaped Charge

The main objective of this study is to quantitatively investigate the ignition and shock sensitivity of NASA Standard Detonator (NSD) and the shock wave propagation of a linear shaped charge (LSC) after being shocked by NSD flyer plate. This combined explosive train was modeled as a coupled Arbitrary Lagrangian-Eulerian (ALE) model with LS-DYNA hydro code. An ignition-and-growth (I&G) reactive model based on unreacted and reacted Jones-Wilkins-Lee (JWL) equations of state was used to simulate the shock initiation. Various NSD-to-LSC stand-off distances were analyzed to calculate the shock initiation (or failure to initiate) and detonation wave propagation along the shaped charge. Simulation results were verified by experimental data which included VISAR tests for NSD flyer plate velocity measurement and an aluminum target severance test for LSC performance verification. Parameters used for the analysis were obtained from various published data or by using CHEETAH thermo-chemical code.

Oguz, Sirri

Effect of Substrate Temperature on the Electrochemical and Supercapacitance Properties of Pulsed Laser-Deposited Titanium Oxynitride Thin Films

Electrocatalytically active titanium oxynitride (TiNO) thin films were fabricated on commercially available titanium metal plates using a pulsed laser deposition method for energy storage applications. The elemental composition and nature of bonding were analyzed using X-ray photoelectron spectroscopy (XPS) to reveal the reacting species and active sites responsible for the enhanced electrochemical performance of the TiNO electrodes. Symmetric supercapacitor devices were fabricated using two TiNO working electrodes separated by an ion-transporting layer to analyze their real-time performance. The galvanostatic charge–discharge studies on the symmetric cell have indicated that TiNO films deposited on the polycrystalline titanium plates at lower temperatures are superior to TiNO films deposited at higher temperatures in terms of storage characteristics. For example, TiNO films deposited at 300 °C exhibited the highest specific capacity of 69 mF/cm 2 at 0.125 mA/cm 2 with an energy density of 7.5 Wh/cm 2 . The performance of this supercapacitor (300 °C TiNO) device is also found to be ~22% better compared to that of a 500 °C TiNO supercapacitor with a capacitance retention ability of 90% after 1000 cycles. Furthermore, the difference in the electrochemical storage and capacitance properties is attributed to the reduced leaching away of oxygen from the TiNO films by the Ti plate at lower deposition temperatures, leading to higher oxygen content in the TiNO films and, consequently, a high redox activity at the electrode/electrolyte interface.

30 DIRECT ENERGY CONVERSION

Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

Deines-Jones, P.

Measurement realities of current collection in dynamic space plasma environments

Theories which describe currents collected by conducting and non-conducting bodies immersed in plasmas have many of their concepts based upon the fundamentals of sheath-potential distributions and charged-particle behavior in superimposed electric and magnetic fields. Those current-collecting bodies (or electrodes) may be Langmuir probes, electric field detectors, aperture plates on ion mass spectrometers and retarding potential analyzers, or spacecraft and their rigid and tethered appendages. Often the models are incomplete in representing the conditions under which the current-voltage characteristics of the electrode and its system are to be measured. In such cases, the experimenter must carefully take into account magnetic field effects and particle anisotropies, perturbations caused by the current collection process itself and contamination on electrode surfaces, the complexities of non-Maxwellian plasma distributions, and the temporal variability of the local plasma density, temperature, composition and fields. This set of variables is by no means all-inclusive, but it represents a collection of circumstances guaranteed to accompany experiments involving energetic particle beams, plasma discharges, chemical releases, wave injection and various events of controlled and uncontrolled spacecraft charging. Here, an attempt is made to synopsize these diagnostic challenges and frame them within a perspective that focuses on the physics under investigation and the requirements on the parameters to be measured. Examples include laboratory and spaceborne applications, with specific interest in dynamic and unstable plasma environments.

Szuszczewicz, Edward P.

Frequency analysis of 4- to 6-keV electrons associated with an auroral arc

The high time resolution (HTR) experiment considered consists of four sections, including electrostatic deflection plates, electron multiplier, preamplifier-integrator, and frequency analyzer. Electrons in the energy range from 4 to 6 keV electrons are selected by the deflection system, after which they are detected, multiplied, and passed to the charge sensitive preamplifier. The charge pulses are amplified and integrated, and the resulting voltage pulse series is fed to the frequency analyzer. The experiment is essentially a flux detector, so that estimates of the input flux can be made from the mean value of the output spectrum. The results obtained with the HTR in a rocket flight on March 14, 1974, are discussed. The lack of modulation noticed in the high-frequency range indicates that there is insufficient wave energy available in the vicinity of the rocket to produce a wave-particle interaction which the HTR is able to observe. This finding is consistent with the stabilization of the plasma by the low flux of energetic electrons.

Murphree, J. S.

Charging rates of metal-dielectric structures

Metal plates partially covered by 0.01-centimeter-thick fluorinated ethylene-propylene (FEP) Teflon were charged in the Lewis Research Center's geomagnetic substorm simulation facility using 5-, 8-, 10-, and 12-kilovolt electron beams. Surface voltage as a function of time was measured for various initial conditions (Teflon discharged or precharged) with the metal plate grounded or floating. Results indicate that both the charging rates and the levels to which the samples become charged are influenced by the geometry and initial charge state of the insulating surfaces. The experiments are described and the results are presented and discussed. NASA charging analyzer program (NASCAP) models of the experiments have been generated, and the predictions obtained are described. Implications of the study results for spacecraft are discussed.

Purvis, C. K.

Space environment durability of beta cloth in LDEF thermal blankets

Beta cloth performance for use on long-term space vehicles such as Space Station Freedom (S.S. Freedom) requires resistance to the degrading effects of the space environment. The major issues are retention of thermal insulating properties through maintaining optical properties, preserving mechanical integrity, and generating minimal particulates for contamination-sensitive spacecraft surfaces and payloads. The longest in-flight test of beta cloth's durability was on the Long Duration Exposure Facility (LDEF), where it was exposed to the space environment for 68 months. The LDEF contained 57 experiments which further defined the space environment and its effects on spacecraft materials. It was deployed into low-Earth orbit (LEO) in Apr. 1984 and retrieved Jan. 1990 by the space shuttle. Among the 10,000 plus material constituents and samples onboard were thermal control blankets of multilayer insulation with a beta cloth outer cover and Velcro attachments. These blankets were exposed to hard vacuum, thermal cycling, charged particles, meteoroid/debris impacts, ultraviolet (UV) radiation, and atomic oxygen (AO). Of these space environmental exposure elements, AO appears to have had the greatest effect on the beta cloth. The beta cloth analyzed in this report came from the MSFC Experiment S1005 (Transverse Flat-Plate Heat Pipe) tray oriented approximately 22 deg from the leading edge vector of the LDEF satellite. The location of the tray on LDEF and the placement of the beta cloth thermal blankets are shown. The specific space environment exposure conditions for this material are listed.

Linton, Roger C.

Report of investigations into charge cadmium reactivity: Nickel-cadmium cell ESD 91-86

In Aug. 1990, a presentation was given at the 25th Ann. IECEC meeting on the results of Destructive Physical Analysis (DPA) on two successive sets of Ni-Cd cells. The cells were of two different separator types, Pellon 2505 and 2536. One cell of each separator type was analyzed on two occasions; the first pair were analyzed to establish baseline data on essentially new cells; the second pair were analyzed after the cells had been on charge-discharge cycling for a year in connection with a satellite simulation study. The gas composition found in the cells, the absence of charged cadmium in the analytical data, and the appearance of dried out portions on the Cd plates in the one year cell S/N 7 which used Pellon 2505 as its separator material, were questions which arose. These concerns are answered and the observational results are clarified.

Lewis, Harlan L.