At least 19 records

Performance degradation due to anodic failure mechanisms in lithium-ion batteries

Here, we report a mechano-chemical model for anodic degradation during fast-charging of nickel-manganese-cobalt (NMC)/graphite (C) cell due to SEI growth, lithium plating/stripping, dead lithium storage, and film fracture of composite SEI and plated lithium film. Degradation of the battery is analyzed for a range of charging rates from 1 to 6 C-rates, and the influence of plating mechanisms – lithium plating and dead lithium deposition and recovery during stripping – on the film resistance of the anode are accounted for in the model. Dynamic evolution of the interfacial properties is modeled using rule-of-mixture approach. Model predictions of plating associated stress fields are used to compute critical energy release rate for film cracking. The results indicate an increased tendency of fracture for thinner SEI film with lithium plating at higher charging rates. The process of reforming the cracked film absorbs a significant portion of the electrode current thereby reducing the cell capacity and plating efficiency. The mechano-chemical model provides an extensive analytical framework for understanding the synergistic coupling of anodic degradation mechanisms, prognosticating conditions of SEI failure, and evaluating the capacity fade and efficiency of lithium-ion battery.

25 ENERGY STORAGE↗

Electronic measurement of microchannel plate pulse height distributions

Microchannel plates are a central component of the x-ray framing cameras used as analog imagers in many plasma experiment diagnostic systems. The microchannel plate serves as an amplifying element, increasing the electronic signal from incident radiation by factors of 10{sup 3}-10{sup 5}, with a broad pulse-height distribution. Seeking to optimize the photon-to-electron conversion efficiency and noise distribution of x-ray cameras, we will characterize the pulse-height distribution of the electron output from a single microchannel plate. Replacing the framing camera's phosphor-coated fiber optic screen with a charge-collection plate and coupling to a low-noise multichannel analyzer, we quantified the distribution in the total charge generated per photon event. The electronically measured pulse height distribution is used to estimate the signal-to-noise ratio of radiographic images from framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemically assembled double-dot single-electron transistor analyzed by the orthodox model considering offset charge

We present the analysis of chemically assembled double-dot single-electron transistors using orthodox model considering offset charges. First, we fabricate chemically assembled single-electron transistors (SETs) consisting of two Au nanoparticles between electroless Au-plated nanogap electrodes. Then, extraordinary stable Coulomb diamonds in the double-dot SETs are analyzed using the orthodox model, by considering offset charges on the respective quantum dots. We determine the equivalent circuit parameters from Coulomb diamonds and drain current vs. drain voltage curves of the SETs. The accuracies of the capacitances and offset charges on the quantum dots are within ±10%, and ±0.04e (where e is the elementary charge), respectively. The parameters can be explained by the geometrical structures of the SETs observed using scanning electron microscopy images. Using this approach, we are able to understand the spatial characteristics of the double quantum dots, such as the relative distance from the gate electrode and the conditions for adsorption between the nanogap electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new particle size analyzer

A new particle sizer which integrates the dispersion and detection parts is presented. Particles are dispersed based on charging between two parallel plates connected to a high voltage power source. The charged particles bounce between the two plates and escape into a measuring area where the size is determined by light scattering. The instrument is calibrated using standard powders. The data obtained from the new instrument are in good agreement with those obtained from a commercial particle size analyzer. The sizer works both for insulator and conductive powders.

36 MATERIALS SCIENCE↗

Pathways towards managing cost and degradation risk of fast charging cells with electrical and thermal controls

The charging rate of Li-ion batteries is limited by the risks of lithium plating and thermal damage, both of which negatively affect lifetime of the batteries. This work analyzes how to minimize charge time and manage the risk of degradation using both electrical and thermal controls. To accomplish this, an electrochemical-thermal model is developed to introduce a constant-risk fast charging protocol which maximizes the charging current while maintaining the cell within pre-defined design limits selected to minimize the risk of degradation. Results indicate 80%-charging of a typical NMC/graphite cell can be achieved within 10 minutes with a cell cost under $100 kW –1 h –1 (corresponding to an 80 μm thick anode) when charged at moderate allowable risks of degradation. Here, we also demonstrate how stretching the allowable risk (i.e., higher temperatures, larger C-rates, and lower anode potential limits) allows affordable design of fast charging cells.

25 ENERGY STORAGE↗

Specific Features of Interatomic Dipole–Dipole Interaction near a Perfectly Conducting Charged Surface

Specific features of dipole–dipole interaction between two motionless point atoms located near a perfectly conducting charged plate are investigated theoretically within a consistent quantum microscopic approach. These features are analyzed on the basis of the dynamics of cooperative spontaneous decay of excited states of a diatomic quasimolecule. The decay rate is investigated as a function of the interatomic distance, the orientation angle of the quasimolecule with respect to the plane of the plate, and the distance between the quasimolecule and the plate. It is shown that the conducting plate significantly modifies the character of dipole–dipole interaction even when the plate is not charged. When the plate is charged, the Stark splitting of atomic levels leads to an additional modification of the interatomic interaction. The features observed are explained on the basis of the analysis of the spectrum of collective states of diatomic molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

A rocket-borne mass analyzer for charged aerosol particles in the mesosphere

An electrostatic mass spectrometer for nanometer-sized charged aerosol particles in the mesosphere has been developed and tested. The analyzer is mounted on the forward end of a rocket and has a slit opening for admitting a continuous sample of air that is exhausted through ports at the sides. Within the instrument housing are two sets of four collection plates that are biased with positive and negative voltages for the collection of negative and positive aerosol particles, respectively. Each collection plate spans about an order of magnitude in mass which corresponds to a factor of 2 in radius. The number density of the charge is calculated from the current collected by the plates. The mean free path for molecular collisions in the mesosphere is comparable to the size of the instrument opening; thus, the analyzer performance is modeled by a Monte Carlo computer code that finds the aerosol particles trajectories within the instrument including both the electrostatic force and the forces from collisions of the aerosol particles with air molecules. Mass sensitivity curves obtained using the computer models are near to those obtained in the laboratory using an ion source. The first two flights of the instrument returned data showing the charge number densities of both positive and negative aerosol particles in four mass ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatics of moving plasma

The stability of charge distribution over the surface of a conducting body in moving plasma is analyzed. Using a finite-width plate streamlined by a cold neutralized electron flow as an example, it is shown that an electrically neutral body can be unstable against the development of spontaneous polarization. The plasma parameters at which such instability takes place, as well as the frequency and growth rate of the fundamental mode of instability, are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of Planar Brushes with End-Functionalized Carboxylic or Amine Groups: Water Structure, Hydrogen Bonds, and Electrostatic Correlations

In this work we present a detailed analysis of two parallel plates grafted with polyethylene glycol (PEG) terminated with carboxylic or amine groups, and discuss the cases of opposite and same charge in the presence of electrolytes. We analyze the screening of charged groups by electrolytes, the role of hydrogen bonds in enhancing attraction or repulsion, hydration forces, competitive binding with counterions, and the hydrogen bond network, crucial to stabilizing the system. Our simulations reveal that, for large plate separation, the system is well described as a “Stern layer”, characterized by strong counterion binding and a subsequent weak diffuse layer. For short plate separation, the system is characterized by strong correlations among end groups and counterions. We also discuss the relevance of charged carboxylic/amine groups in different problems with a particular emphasis on nanoparticle assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipactor saturation in parallel-plate waveguides

The saturation stage of a multipactor discharge is considered of interest, since it can guide towards a criterion to assess the multipactor onset. The electron cloud under multipactor regime within a parallel-plate waveguide is modeled by a thin continuous distribution of charge and the equations of motion are calculated taking into account the space charge effects. The saturation is identified by the interaction of the electron cloud with its image charge. The stability of the electron population growth is analyzed and two mechanisms of saturation to explain the steady-state multipactor for voltages near above the threshold onset are identified. The impact energy in the collision against the metal plates decreases during the electron population growth due to the attraction of the electron sheet on the image through the initial plate. When this growth remains stable till the impact energy reaches the first cross-over point, the electron surface density tends to a constant value. When the stability is broken before reaching the first cross-over point the surface charge density oscillates chaotically bounded within a certain range. In this case, an expression to calculate the maximum electron surface charge density is found whose predictions agree with the simulations when the voltage is not too high.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End loss analyzer system for measurements of plasma flux at the C-2U divertor electrode

An end loss analyzer system consisting of electrostatic, gridded retarding-potential analyzers and pyroelectric crystal bolometers was developed to characterize the plasma loss along open field lines to the divertors of C-2U. The system measures the current and energy distribution of escaping ions as well as the total power flux to enable calculation of the energy lost per escaping electron/ion pair. Special care was taken in the construction of the analyzer elements so that they can be directly mounted to the divertor electrode. An attenuation plate at the entrance to the gridded retarding-potential analyzer reduces plasma density by a factor of 60 to prevent space charge limitations inside the device, without sacrificing its angular acceptance of ions. In addition, all of the electronics for the measurement are isolated from ground so that they can float to the bias potential of the electrode, 2 kV below ground.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Substrate Temperature on the Electrochemical and Supercapacitance Properties of Pulsed Laser-Deposited Titanium Oxynitride Thin Films

Electrocatalytically active titanium oxynitride (TiNO) thin films were fabricated on commercially available titanium metal plates using a pulsed laser deposition method for energy storage applications. The elemental composition and nature of bonding were analyzed using X-ray photoelectron spectroscopy (XPS) to reveal the reacting species and active sites responsible for the enhanced electrochemical performance of the TiNO electrodes. Symmetric supercapacitor devices were fabricated using two TiNO working electrodes separated by an ion-transporting layer to analyze their real-time performance. The galvanostatic charge–discharge studies on the symmetric cell have indicated that TiNO films deposited on the polycrystalline titanium plates at lower temperatures are superior to TiNO films deposited at higher temperatures in terms of storage characteristics. For example, TiNO films deposited at 300 °C exhibited the highest specific capacity of 69 mF/cm 2 at 0.125 mA/cm 2 with an energy density of 7.5 Wh/cm 2 . The performance of this supercapacitor (300 °C TiNO) device is also found to be ~22% better compared to that of a 500 °C TiNO supercapacitor with a capacitance retention ability of 90% after 1000 cycles. Furthermore, the difference in the electrochemical storage and capacitance properties is attributed to the reduced leaching away of oxygen from the TiNO films by the Ti plate at lower deposition temperatures, leading to higher oxygen content in the TiNO films and, consequently, a high redox activity at the electrode/electrolyte interface.

30 DIRECT ENERGY CONVERSION↗

Elucidating mechanisms of Li plating on Li anodes of lithium-based batteries

Lithium metal is known as a very promising anode material for lithium-based batteries possessing a quite high theoretical capacity. But it has been kept away from practical applications due to its extreme reactivity and potential safety hazards led by serious dendrite growth. The origins of dendrite formation may be associated with the mechanisms of Li plating and with the mode of charge transfer during Li reduction or oxidation at the anode-electrolyte interface. Here, density functional theory (DFT) calculations are conducted to analyze the electron transfer between Li (100) and Li cations located in the proximity of the surface in several simulation models. The study includes two common used solvents: ethylene carbonate and dimethoxyethane (EC and DME), and a LiPF 6 salt, that surround the Li cation over perfect, defect-containing, and Li 2 CO 3 -passivated Li (100) surfaces. Our calculations demonstrate that the Li cation is easily reduced when bonding to DME rather than EC and its preferred deposition site is the hollow site on both perfect and defective Li (100). Additionally, a compact Li 2 CO 3 layer inhibits the charge transfer from Li metal to Li cations, thus modifying Li plating. It is concluded that the extreme reactivity of the Li metal surface induces a strongly inhomogeneous electron distribution upon deposition of a cation on the surface. This strong charge inhomogeneity may promote uneven Li nucleation and growth, eventually resulting in dendritic behavior.

25 ENERGY STORAGE↗

Measuring ion velocity distribution functions through high-aspect ratio holes in inductively coupled plasmas

Several issues associated with plasma etching of high aspect ratio structures originate from the ions' bombardment of the sidewalls of the feature. The off normal angle incident ions are primarily due to their temperature at the sheath edge and possibly to charging effects. We have measured the ion velocity distribution function (IVDF) at the wafer surface in an industrial inductively coupled plasma reactor by using multigrid retarding field analyzers (RFA) in front of which we place 400 μm thick capillary plates with holes of 25, 50, and 100 μm diameters. The RFA then probes IVDF at the exit of the holes with Aspect Ratios (AR) of 16, 8, and 4, respectively. The results show that the ion flux dramatically drops with the increase in AR. By comparing the measured IVDF with an analytical model, we concluded that the ion temperature is 0.27 eV in our plasma conditions. The charging effects are also observed and are shown to significantly reduce the ion energy at the bottom of the feature but only with a “minor” effect on the ion flux and the shape of the IVDF.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low energy highly charged ion beam facility at Inter University Accelerator Centre: Measurement of the plasma potential and ion energy distributions

A deceleration lens coupled to one of the beam lines of the electron cyclotron resonance based low energy beam facility at Inter University Accelerator Centre is reported. This system is capable of delivering low energy (2.5 eV/q–1 keV/q) highly charged ion beams. The presence of plasma potential hinders the measurements of low energies (<50 eV), therefore, plasma potential measurements have been undertaken using a retarding plate analyzer in unison with the deceleration assembly. The distributions of the ion energies have been obtained and the effect of different source parameters on these distributions is studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion protection of ENIG surface finishing using electrochemical methods

Four types of thin film coating were carried out on copper for electronic materials by the electroless plating method at a pH range from 3 to 9. The coating performance was evaluated by electrochemical impedance spectroscopy and potentiodynamic polarization testing in a 3.5 wt.% NaCl solution. In addition, atomic force microscopy and X-ray diffraction were also used to analyze the coating surfaces. The electrochemical behavior of the coatings was improved using the electroless nickel plating solution of pH 5. The electroless nickel/immersion gold on the copper substrate exhibited high protective efficiency, charge transfer resistance and very low porosity, indicating an increase in corrosion resistance. Atomic force microscopy and X-ray diffraction analyses confirmed the surface uniformity and the formation of the crystalline-refined NiP {l_brace}1 2 2{r_brace} phase at pH 5.

36 MATERIALS SCIENCE↗

Inverse time-of-flight spectrometer for beam plasma research

The paper describes the design and principle of operation of an inverse time-of-flight spectrometer for research in the plasma produced by an electron beam in the forevacuum pressure range (5–20 Pa). In the spectrometer, the deflecting plates as well as the drift tube and the primary ion beam measuring system are at high potential with respect to ground. This provides the possibility to measure the mass-charge constitution of the plasma created by a continuous electron beam with a current of up to 300 mA and electron energy of up to 20 keV at forevacuum pressures in the chamber placed at ground potential. Research results on the mass-charge state of the beam plasma are presented and analyzed.