Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charged particle telescope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Background Measurements and Simulations of the ComPair Balloon Flight

ComPair, a prototype of the All-sky Medium Energy Gamma-ray Observatory (AMEGO), completed a short-duration high-altitude balloon campaign on 27 August 2023 from Fort Sumner, New Mexico, USA. The goal of the balloon flight was to demonstrate ComPair as both a Compton and Pair telescope in flight, reject the charged particle background, and measure the background γ-ray spectrum. This analysis compares measurements from the balloon flight with Monte Carlo simulations to benchmark the instrument. The comparison finds good agreement between the measurements and simulations and supports the conclusion that ComPair accomplished its goals for the balloon campaign. Additionally, two charged particle background rejection schemes are discussed: a soft ACD veto that records a higher charged particle event rate but with less risk of event loss, and a hard ACD veto that limits the charged particle event rate on board. There was little difference in the measured spectra from the soft and hard ACD veto schemes, indicating that the hard ACD veto could be used for future flights. The successes of ComPair’s engineering flight will inform the development of the next generation of ComPair with upgraded detector technology and larger active area.

79 ASTRONOMY AND ASTROPHYSICS↗

Developing the S 32 ( p , d ) S * 31 ( p ) ( γ ) reaction to probe the P 30 ( p , γ ) S 31 reaction rate in classical novae

Background: The 30 P(p,γ) 31 S reaction rate is one of the largest remaining sources of uncertainty in the final abundances of nuclei created in a classical nova involving a ONe white dwarf. The reaction rate directly influences silicon isotopic ratios, which are used as identifiers of presolar grains with nova origins. Additionally, the uncertainty in the 30 P(p,γ) 31 S reaction rate has been found to limit the use of nova nuclear thermometers based on observations of elemental ratios in nova ejecta. Purpose: Reduce uncertainties in the nuclear data for proton-unbound states in 31 S, which act as resonances for the 30 P(p,γ) 31 S reaction at classical nova temperatures, and develop a technique for high efficiency, high-resolution reaction-decay coincidence measurements. Methods: Here, the 32 S(p,d) 31 S reaction was used to populate the states of interest in 31 S. The experiment was performed at the Texas A&M Cyclotron Institute using the LLNL Hyperion array for the detection of charged particles and γ rays. A downstream silicon telescope was used to select reaction deuterons, and a single upstream silicon detector was used to measure protons emitted in the decay of unbound 31 S levels. Results: Several states in 31 S above the proton separation energy were observed to have been populated. Decay protons from the resonant states in 31 S were identified as events in the upstream silicon detectors that came in coincidence with deuterons in the downstream telescope. Protons emitted from these states were measured and branching ratios extracted. Conclusions: While no new reaction rate is derived, spin-parity assignments for several higher-lying proton unbound states have been confirmed. Measured p 0 branching ratios for these levels have been compared to previous measurements with good agreement, and in some cases provided a reduction in uncertainty. The previously identified T = 3/2 state may have been incorrectly assigned a large p 0 branching ratio in a previous measurement. The technique of measuring reaction-decay coincidences with a particle-gamma setup appears promising.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reaction losses of charged particles in CsI(Tl) crystals

To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei within the detector and for the scattering of incident particles out of the detector, without depositing their full energy in the active material. In this paper, we develop a method for measuring such corrections and determine the reaction and out-scattering losses for data measured with the silicon-CsI(Tl) telescopes of the newly developed HiRA10 array. Here, the extracted efficiencies are in good agreement with model predictions using the GEANT4 reaction loss algorithm for Z = 1 and Z = 2 isotopes. After correcting for the HiRA10 geometry, we obtain a general function that describes the loss of efficiency due to reaction losses in CsI(Tl) crystals as a function of range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of a Cosmic Ray Telescope for the hpDIRC Radiators at the Electron Ion Collider

Nuclear physics pertains to the understanding of the structure and dynamics of the nuclei of atoms, accounting for almost all of the visible matter in the universe. The future Electron-Ion Collider (EIC) will play a crucial role in discovering new laws of Nuclear physics. A pivotal aspect of the EIC is exceptional particle identification (PID). Identifying charged hadrons in their final state can be done with special types of Cherenkov Detectors. One type of detector utilizes the Detection of Internally Reflected Cherenkov radiation (DIRC) phenomena. Able to provide precise PID separation up to relatively high momenta, DIRC radiators, made of synthetic fused silica, produce Cherenkov radiation when hit by high energy electromagnetically charged particles. In this thesis we present details of the construction of a cosmic ray telescope (CRT) to utilize high energy muons from cosmic rays to test DIRC radiators. These types of radiators will be used for the high-performance DIRC (hpDIRC) to be used in the ePIC detector in the future EIC. We go into detail on the DIRC process and the individual pieces of hardware required to make the CRT. Lots of labor was used for certain parts of the CRT, specifically the construction of a dark box for the DIRC radiators. The CRT construction and implementation of all of its components are planned to be completed before 2025.

Shankman, Nathan↗

Gamma Rays from Fast Black-hole Winds

We study massive black holes at the centers of galaxies that can launch powerful wide-angle winds that, if sustained over time, can unbind the gas from the stellar bulges of galaxies. These winds may be responsible for the observed scaling relation between the masses of the central black holes and the velocity dispersion of stars in galactic bulges. Propagating through the galaxy, the wind should interact with the interstellar medium creating a strong shock, similar to those observed in supernovae explosions, which is able to accelerate charged particles to high energies. In this work we use data from the Fermi Large Area Telescope to search for the γ-ray emission from galaxies with an ultrafast outflow (UFO): a fast (v ~0.1 c), highly ionized outflow, detected in absorption at hard X-rays in several nearby active galactic nuclei (AGN). Adopting a sensitive stacking analysis we are able to detect the average γ-ray emission from these galaxies and exclude that it is due to processes other than UFOs. Moreover, our analysis shows that the γ-ray luminosity scales with the AGN bolometric luminosity and that these outflows transfer ~0.04% of their mechanical power to γ-rays. Interpreting the observed γ-ray emission as produced by cosmic rays (CRs) accelerated at the shock front, we find that the γ-ray emission may attest to the onset of the wind–host interaction and that these outflows can energize charged particles up to the transition region between galactic and extragalactic CRs.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Atmospheric pion, kaon, and muon fluxes for sub-orbital experiments

Cosmic rays interacting with the Earth's atmosphere generate extensive air showers, which produce Cherenkov, fluorescence and radio emissions. These emissions are key signatures for detection by ground-based, sub-orbital, and satellite-based telescopes aiming to study high energy cosmic ray and neutrino events. However, detectors operating at ground and balloon altitudes are also exposed to a background of atmospheric charged particles, primarily pions, kaons, and muons, that can mimic or obscure the signals from astrophysical sources. In this work, we use coupled cascade equations to calculate the atmospheric pion, kaon and muon fluxes reaching detectors at various altitudes. Our analysis focuses on energies above 10 GeV, where the influence of the Earth's magnetic field on particle trajectories is minimal. We provide angular and energy-resolved flux estimates and discuss their relevance as background for extensive air shower detection. Furthermore, our results are potentially relevant for interpreting data from current and future balloon-borne experiments such as EUSO-SPB2 and for refining trigger and veto strategies in Cherenkov and fluorescence telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of front-end parameters of the ARCADIA MD3 on charged particle detection

The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 $μ$m active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.

Pantouvakis, C. [Padua U.; INFN, Padua]↗

First Analysis of Earth's Stratospheric γ ‐Ray Emission in Geographical Coordinates With Fermi LAT

Abstract From low‐Earth orbit, the Earth is an extremely bright γ ‐ray source compared to distant astrophysical objects. The high‐energy γ ‐ray emission, from the Earth's upper atmosphere, is produced by the interactions between cosmic rays (CRs) and air molecules. As CRs are predominantly charged particles, the geomagnetic field acts as a spectrometer, forbidding CRs below a certain energy to arrive and interact with the atmosphere at a given geomagnetic location from a given direction. We use photon data between 0.2 and 20 GeV as observed by the Fermi Large Area Telescope (LAT) to create, for the first time, stratospheric γ ‐ray emission maps of the Earth in the geographical coordinate system, for different viewing directions from LAT altitude. These maps confirm a strong association between measured γ ‐ray fluxes and geomagnetic cutoffs for CRs. We also report the spectrum of the Earth's stratospheric γ ‐ray emission in cardinal directions and use the geomagnetic spectrometer effect to infer the atmosphere's yield function of γ rays per incoming CR proton as a function of CR rigidity at the altitude of the Fermi spacecraft. This work is relevant to the study of near‐Earth radiation exposure for astronauts and spacecraft, modeling the geomagnetic field, and CR‐air interactions.

Madlee, S.↗

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Before and After Irradiation of Pixelated 3D Silicon Sensors for the HL-LHC CMS Tracker

The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test Beam Results of Planar Pixel Sensor for the CMS Phase 2 Inner Tracker Upgrade

Results of the test beam measurements that characterise the performance of CMS Readout Chip (CROC) sensors to be used in the High Luminosity era of the Large Hadron Collider (HL-LHC) are presented. The HL-LHC peak instantaneous luminosity of $7.5 \times 10^{34} \ \text{cm}^{-2} s^{-1}$ corresponds to an average of around 200 inelastic proton-proton collisions per beam-crossing every 25 ns. In order to efficiently reconstruct and track particles in this extreme and challenging conditions, the present CMS tracking detector will be completely replaced. The new tracking detector consists of an Inner Tracker closest to the beamline and an Outer Tracker surrounding it. These are populated with modules that comprise of readout chips and silicon sensors. The test beam measurements of these modules are vital to understand the performance of the related technologies. Using a primary 120 GeV proton beam from the Main Injector at Fermilab, data was collected at the Fermilab Test Beam Facility (FTBF) using the silicon tracker telescope that provides a precision position measurement of the track impact point with less than 5 $\mu$m uncertainty. The proton beam was incident on a 1x2 planar CROC module developed by Hamamatsu. The sensor has 100x25 $\mu m^2$ standard pixels and also a smaller number of 225x25 $\mu m^2$ longer pixels at the boundary between the two ROCs. We present characterization of these modules that includes pixel efficiency, resolution, cluster size and charge distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗