Low energy charged-particle detection using the continuous-channel electron multiplier.
Windowless continuous-channel electron multiplier detecting low energy charged particles in space
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Windowless continuous-channel electron multiplier detecting low energy charged particles in space
Design and performance of curved photomultiplier tube - effects of structural configuration on dead time and gain stability
A film-growth process was developed for polycrystalline mercuric iodide that creates cost-effective, large-area detectors for high-energy charged-particle detection. A material, called a barrier film, is introduced onto the substrate before the normal mercuric iodide film growth process. The barrier film improves the quality of the normal film grown and enhances the adhesion between the film and the substrate. The films grown using this improved technique were found to have adequate signal-to-noise properties so that individual high-energy charged -particle interactions could be distinguished from noise, and thus, could be used to provide an anticoincidence veto function as desired.
Delta-Doped CCDs were developed at the Microdevices Laboratory at the Jet Propulsion Laboratory to address quantum efficiency and quantum efficiency hysteresis in UV CCDs.
Results of an extensive search for electron plasma oscillations associated with type III radio noise bursts are presented which were obtained by analyzing 87 type III bursts detected in plasma-wave and charged-particle measurements carried out by IMP 6, 7, and 8. Only one case is found for which plasma oscillations were associated with electrons of solar origin; at least eight events are identified in which no plasma oscillations were detected even though electrons from solar flares were clearly evident. The type III emissions are compared with similar radiation coming from upstream of earth's bow shock at the harmonic of the local electron plasma frequency, and quantitative calculations of the rate of conversion from plasma oscillatory energy to electromagnetic radiation are performed. The results show that electron plasma oscillations are seldom observed in association with solar electron events and type III radio bursts at 1.0 AU and that neither the type III emissions nor the radiation from upstream of the bow shock can be adequately explained by a current model for the coupling of electron plasma oscillations to electromagnetic radiation. Several possible explanations are considered for this discrepancy between theory and observations.
The upper limit on the quiet time solar neutron flux from 1 to 20 MeV has been measured to be less than .002 neutrons at the 95% confidence level. This result is deduced from the OGO-6 neutron detector measurements of the 'day-night' effect near the equator at low altitudes for the period from June 7 to Dec. 23, 1969. The OGO-6 detector had very low (less than 4%) counting rate contributions from locally produced neutrons in the detecting system and the spacecraft and from charged-particle interactions in the neutron sensor.
Experimental methods of mapping the equipotential surfaces near some structure of interest rely on the detection of charged particles which have traversed the regions of interest and are detected remotely. One method is the measurement of ion energies for ions created at a point of interest and expelled from the region by the fields. The ion energy at the detector in eV corresponds to the potential where the ion was created. An ionizing beam forms the ions from background neutrals. The other method is to inject charged particles into the region of interest and to locate their exit points. A set of several trajectories becomes a data base for a systematic mapping technique. An iterative solution of a boundary value problem establishes concepts and limitations pertaining to the mapping problem.
A charged-particle detector array flown on a high-altitude balloon has detected and measured some 30,000 cosmic-ray nuclei with Z of at least 12. The charge spectrum at the top of the atmosphere for nuclei with energies greater than 650 MeV/n and the energy spectrum for energies between 650 and 1800 MeV/n are reported and compared with previously published results. The charge spectrum at the 'source' of cosmic rays is deduced from these data and compared with a recent compilation of 'galactic' abundances.
The neutron counter proposed here has a long history and was commercially available in a somewhat different form. This counter would be suitable for a rover or lander since it requires a rather long measuring time for each placement. It consists of two silicon wafer charged-particle counters with a layer of Li-6F deposited on the inner surface of one. The neutron detecting reaction is Li-6(n,H-3)He-4 in which the alpha particle and the triton are emitted from the Li-6 deposit back to back. If one of the detectors sees the alpha particle, the other will see the triton. This allows one to use a coincidence technique that virtually eliminates all background. The signals from each detector can be added together so that the total energy of the reaction, Q=4.6 MeV and the kinetic energy of the neutron, can be recorded.
A joint Air Force/NASA comprehensive research and technology program on spacecraft environmental interactions to develop technology to control interactions between large spacecraft systems and the charged-particle environment of space is described. This technology will support NASA/Department of Defense operations of the shuttle/IUS, shuttle/Centaur, and the force application and surveillance and detection missions, planning for transatmospheric vehicles and the NASA space station, and the AFSC military space system technology model. The program consists of combined contractual and in-house efforts aimed at understanding spacecraft environmental interaction phenomena and relating results of ground-based tests to space conditions. A concerted effort is being made to identify project-related environmental interactions of concern. The basic properties of materials are being investigated to develop or modify the materials as needed. A group simulation investigation is evaluating basic plasma interaction phenomena to provide inputs to the analytical modeling investigation. Systems performance is being evaluated by both groundbased tests and analysis.
Plasma waves detected by the Voyager 1 and 2 spacecraft beyond about 12 AU that may be associated with the turbulence expected at the heliopause are interpreted in terms of the characteristics of the interplanetary medium at large heliocentric distances. The low-energy charged-particle environment in the outer heliosphere during the observations of the unusual plasma-wave signals is addressed. The particle data suggest that the outer heliosphere was unusually stable and free of transient shock and particle events for the roughly eight months during the wave observations.
The Charged-Particle Lunar Environment Experiment (CPLEE), a part of the Apollo 14 ALSEP, is an ion-electron spectrometer capable of measuring ions and electrons with energies between 40 eV and 50 keV. Accordingly, the instrument, with apertures 26 cm above the surface, has detected a layer of photoelectrons, or photoelectron gas above the sunlit lunar surface with energies ranging up to 200 eV. The experimental data for periods when the moon was in the earth's magnetotail for electron energies between 40 and 200 eV follows a defined power-law spectrum. The implications of this measurement are two-fold in that the lunar surface potential can be immediately determined to be at least 200 V, and a value of the photoelectron yield of the lunar surface material for photon energies above 40 eV may be computed.
A survey is conducted for state-of-the-art techniques for detecting energetic neutral atoms (ENAs) in the 100-300 keV range, in regions from the heliospheric boundary to the auroral zones where the solar wind plays a crucial role. While ENA spectrometry allows sampling of the mass and energy distributions of a distant plasma, ENA imaging gives a global view of the structures and dynamics of an extended plasma. The ENA instrument designs discussed share many components which exhibit excellent flight performance as elements in charged-particle analyzers for space missions.
OWL [1] uses the Earth's atmosphere as a vast calorimeter to fully enable the emerging field of charged-particle astronomy with high-statistics measurements of ultra-high-energy cosmic rays (UHECR) and a search for sources of UHE neutrinos and photons. Confirmation of the Greisen-Zatsepin-Kuzmin (GZK) suppression above approx. 4 x 10(exp 19) eV suggests that most UHECR originate in astrophysical objects. Higher energy particles must come from sources within about 100 Mpc and are deflected by approx. 1 degree by predicted intergalactic/galactic magnetic fields. The Pierre Auger Array, Telescope Array and the future JEM-EUSO ISS mission will open charged-particle astronomy, but much greater exposure will be required to fully identify and measure the spectra of individual sources. OWL uses two large telescopes with 3 m optical apertures and 45 degree FOV in near-equatorial orbits. Simulations of a five-year OWL mission indicate approx. 10(exp 6) sq km/ sr/ yr of exposure with full aperture at approx. 6 x 10(exp 19) eV. Observations at different altitudes and spacecraft separations optimize sensitivity to UHECRs and neutrinos. OWL's stereo event reconstruction is nearly independent of track inclination and very tolerant of atmospheric conditions. An optional monocular mode gives increased reliability and can increase the instantaneous aperture. OWL can fully reconstruct horizontal and upward-moving showers and so has high sensitivity to UHE neutrinos. New capabilities in inflatable structures optics and silicon photomultipliers can greatly increase photon sensitivity, reducing the energy threshold for n detection or increasing viewed area using a higher orbit. Design trades between the original and optimized OWL missions and the enhanced science capabilities are described.
Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.
We have developed a general theoretical model for the interaction of ionizing radiation with chromatin. Chromatin is modeled as a 30-nm-diameter solenoidal fiber comprised of 20 turns of nucleosomes, 6 nucleosomes per turn. Charged-particle tracks are modeled by partitioning the energy deposition between primary track core, resulting from glancing collisions with 100 eV or less per event, and delta rays due to knock-on collisions involving energy transfers >100 eV. A Monte Carlo simulation incorporates damages due to the following molecular mechanisms: (1) ionization of water molecules leading to the formation of OH, H, eaq, etc.; (2) OH attack on sugar molecules leading to strand breaks: (3) OH attack on bases; (4) direct ionization of the sugar molecules leading to strand breaks; (5) direct ionization of the bases. Our calculations predict significant clustering of damage both locally, over regions up to 40 bp and over regions extending to several kilobase pairs. A characteristic feature of the regional damage predicted by our model is the production of short fragments of DNA associated with multiple nearby strand breaks. The shapes of the spectra of DNA fragment lengths depend on the symmetries or approximate symmetries of the chromatin structure. Such fragments have subsequently been detected experimentally and are reported in an accompanying paper (B. Rydberg, Radiat, Res. 145, 200-209, 1996) after exposure to both high- and low-LET radiation. The overall measured yields agree well quantitatively with the theoretical predictions. Our theoretical results predict the existence of a strong peak at about 85 bp, which represents the revolution period about the nucleosome. Other peaks at multiples of about 1,000 bp correspond to the periodicity of the particular solenoid model of chromatin used in these calculations. Theoretical results in combination with experimental data on fragmentation spectra may help determine the consensus or average structure of the chromatin fibers in mammalian DNA.
An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).
The development of the Small Deflection Energy Analyzer (SDEA) charged-particle spectrometer for energy and angle distributions responds to a longstanding need to measure the wind velocity vector in Earth s thermosphere, and to obtain the ion-drift vector in the ionosphere. The air and ions above 120 km are endowed with bulk velocities and temperatures just like air near the ground, but with separate spatial and temporal variations. It is important to understand these not only for study of the physics and chemistry of the Sun-Earth connection, but also for spacecraft orbit predictions, and communications through the ionosphere. The SDEA consists of a pair of parallel conducting plates separated by a small distance, with an entrance slit on one end, and an exit slit on the other. A voltage applied to these plates develops an electric field between the plates, and this field deflects ions passing through it. If an ion has too little energy, it will strike one of the plates. If it has too much, it will strike the back wall. An ion with the amount of energy being searched for will have its trajectory bent just enough to exit the back slit. The SDEA units are compact, rectangular, and operate with low voltages. The units can be built up into small arrays. These arrays could be used either to widen the field of view or to sharpen an existing one. This approach can also be used to obtain angular distributions in two planes simultaneously, thus cutting down the ion source power requirements in half. This geometry has enabled a new mass-spectrometer concept that can provide miniaturized mass spectrometers for use in industrial plants, air-pollution monitoring, and noxious-gas detection.