238 U PFNS Evaluation Update [Slides]

Experimental 238 U PFNS were reviewed in detail including Chi-Nu PFNS. 7/10 data sets have been accepted. We have performed a detailed UQ using LANL code ARIADNE and templates of expected PFNS measurement uncertainties. we have included Chi-Nu PFNS in experimental data base. The extended Los Alamos model in CoH was used for prior calculation. Multiple chance fission and pre-equilibrium (with exciton model) contributions were modeled.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating the 238 U PFNS Including Chi-Nu Experimental Data

This report documents an evaluation of 238 U prompt fission neutron spectra (PFNS) which is a deliverable for a FY2024 Q4 NCSP (Nuclear Criticality Safety Program) milestone. This evaluation is new; its prior input is based on extended Los Alamos and exciton models implemented in the code CoH. Experimental covariances were estimated for five experimental data sets. One of these data sets that was measured by the Chi-Nu team of LANL and LLNL. It covers the 238 U PFNS for continuous incident-neutron energies of 1–20 MeV and outgoing-neutron energies from 10 keV– 10 MeV with high precision. Contrary to Chi-Nu data, previous data sets were measured in a limited energy range. The resulting evaluated data correspond well to the experimental PFNS taken into account for the evaluation. The evaluated PFNS also produce average mean energies in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of the Flattop, Flattop-Pu and BigTen ICSBEP critical assemblies (which all have thick reflectors with high percentages of 238 U), the differences of simulated values compared to those using ENDF/B-VIII.1β3 is modest (less than 25 pcm). In addition to that, the new PFNS predict on average 238 U LLNL pulsed-sphere neutron-leakage spectra slightly better than ENDF/BVIIII.0 and ENDF/B-VIII.1β3 PFNS. The differences are, however, well within the experimental uncertainties.

238U↗

Evaluating 240 Pu Prompt Fission Neutron Spectra Including Chi-Nu Experimental Data

This report documents an evaluation of 240 Pu prompt fission neutron spectra (PFNS) including Chi-Nu experimental data. This work is a FY2025 Q4 NCSP (Nuclear Criticality Safety Program) milestone and named a “strategic priority”. This evaluation is new; it differs substantially from the most recent evaluation included in the ENDF/B library, which was for ENDF/B-VII.1 and then carried over unchanged to ENDF/B-VIII.1. The key difference between ENDF/B-VIII.1 and the new evaluation is that we have, for the first time, realistic experimental 240 Pu PFNS covering a broad incident and outgoing neutron energy range.

240Pu↗

Measurement of the 238 U( n,f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons with 1.5–20 MeV energy

With the recent emergence of fast nuclear reactors, there has been a corresponding increasing interest in 238 U-related nuclear data. However, while existing literature data span much of the energy ranges of interest for the prompt fission neutron spectrum (PFNS) for neutron-induced fission of 238U, most literature data sets are highly correlated, and thus new, independent measurements of this quantity are needed. In this work, we report the results of a new measurement of the 238 U PFNS at the Los Alamos Neutron Science Center for incident neutron energies from 1.5–20.0 MeV, and outgoing neutron energies of 0.01–10.0 MeV. With some notable exceptions, the present results generally agree with existing literature data, especially with regard to features relating to multichance fission and pre-equilibrium features in the PFNS, thus adding confidence to existing nuclear data evaluations and filling in gaps of knowledge at previously unmeasured incident neutron energies. This result is the third in a series of PFNS measurements by the Chi-Nu collaboration now spanning all three major actinides, 239 Pu, 235 U, and 238 U. Thus, for the first time, we report reliable experimental PFNS ratios and average PFNS energy comparisons for measurements of all three of these isotopes including accurate correlations between the different, but correlated experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the prompt fission neutron spectrum from 800 keV to 10 MeV for 240 Pu(sf) and for the 240 Pu($n,f$) reaction induced by neutrons of energy from 1–20 MeV

Here, the presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, (n,f), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, (sf), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu(sf) and the 240 Pu(n,f) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the (n,f) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.