Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chirped pulse amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dispersion compensation in chirped pulse amplification systems

A chirped pulse amplification system includes a laser source providing an input laser pulse along an optical path. The input laser pulse is characterized by a first temporal duration. The system also includes a multi-pass pulse stretcher disposed along the optical path. The multi-pass pulse stretcher includes a first set of mirrors operable to receive input light in a first plane and output light in a second plane parallel to the first plane and a first diffraction grating. The pulse stretcher also includes a second set of mirrors operable to receive light diffracted from the first diffraction grating and a second diffraction grating. The pulse stretcher further includes a reflective element operable to reflect light diffracted from the second diffraction grating. The system further includes an amplifier, a pulse compressor, and a passive dispersion compensator disposed along the optical path.

42 ENGINEERING↗

MTW-OPAL: a technology development platform for ultra-intense optical parametric chirped-pulse amplification systems

Optical parametric chirped-pulse amplification implemented using multikilojoule Nd:glass pump lasers is a promising approach for producing ultra-intense pulses (>10 23 W/cm 2 ). We report on the MTW-OPAL Laser System, an optical parametric amplifier line (OPAL) pumped by the Nd:doped portion of the multi-terawatt (MTW) laser. This midscale prototype was designed to produce 0.5-PW pulses with technologies scalable to tens of petawatts. Technology choices made for MTW-OPAL were guided by the longer-term goal of two full-scale OPALs pumped by the OMEGA EP to produce 2 × 25-PW beams that would be co-located with kilojoule–nanosecond ultraviolet beams. Several MTW-OPAL campaigns that have been completed since “first light” in March 2020 show that the laser design is fundamentally sound, and optimization continues as we prepare for “first-focus” campaigns later this year.

42 ENGINEERING↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

Current Status of Chirped-Pulse Amplification Technology and Its Applications

We survey current status of chirped-pulse amplification development and its applications. We start with the review of optical compressor and stretcher as well as the amplification techniques. The methods to control spatial and temporal profile of the laser pulse as well as the state-of-the-arts spatiotemporal control techniques and designs of high repetition-rate amplifiers are discussed. Examples of applications in medical and particle acceleration are introduced.

43 PARTICLE ACCELERATORS↗

Demonstration of a 2 ps, 5 TW peak power, long-wave infrared laser based on chirped-pulse amplification with mixed-isotope CO 2 amplifiers 2 amplifiers

We report generation of 5 TW peak power in a 2 ps pulse at 9.2 µm via chirped-pulse amplification (CPA) in mixed-isotope high-pressure CO 2 laser amplifiers. This represents the highest peak power in a single picosecond pulse format and the shortest pulse at terawatt peak power ever achieved in the long-wave infrared (LWIR) spectral range. Maximum demonstrated energy of the compressed pulse is 14 J and minimum period between shots is 20 s. The successful implementation of the chirped pulse amplification technique in a short-pulse gas laser opens a route to development of LWIR laser facilities with tens of terawatts of peak power, thus approaching the number of photons per optical cycle of current near-infrared laser systems based on solid-state active media.

43 PARTICLE ACCELERATORS↗

Power limitations and pulse distortions in an Yb : KGW chirped-pulse amplification laser system

We have studied self-action effects (self-focusing and self-phase modulation) and stimulated Raman scattering in an Yb : KGW chirped-pulse amplification laser system. The results demonstrate that self-focusing in combination with thermal lensing may significantly limit the chirped pulse energy in this system (down to 200 μJ) even at a relatively long pulse duration (50 ps). Nonlinear lenses in the laser crystals in combination with thermal lenses bring the regenerative amplifier cavity in the laser system to the instability zone and limit the average output power at pulse repetition rates under 50 kHz. Self-phase modulation, a manifestation of self-action, may significantly distort a recompressed femtosecond pulse at energies near the self-focusing threshold. Stimulated Raman scattering in such a laser has a weaker effect on output parameters than do self-focusing and thermal lensing, and Raman spectra are only observed in the case of pulse energy instability. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyper dispersion pulse compressor for chirped pulse amplification systems

A grating pulse compressor configuration is introduced for increasing the optical dispersion for a given footprint and to make practical the application for chirped pulse amplification (CPA) to quasi-narrow bandwidth materials, such as Nd:YAG. The grating configurations often use cascaded pairs of gratings to increase angular dispersion an order of magnitude or more. Increased angular dispersion allows for decreased grating separation and a smaller compressor footprint.

Barty, Christopher P. J.↗

Simulation of grating compressor misalignment tolerances and mitigation strategies for chirped-pulse–amplification systems of varying bandwidths and beam sizes

Here, the effects of pulse compressor grating misalignment on the pulse duration and focusability are simulated for chirped-pulse–amplification systems of varying bandwidth, beam size, groove density, and incident angle. Tilt-alignment tolerances are specified based on a √2 drop in focused intensity, illustrating how tolerances scale with bandwidth and compressor beam size, which scales with energy when transformed via known grating damage thresholds. Grating-alignment tolerance scaling with grating groove density and incident/diffracted angles is investigated and applied to compressor design. A correlation between grating tip and in-plane rotation error sensitivity is defined and used to compensate residual out-of-plane angular dispersion, even for ultra-broadband pulses. Simulation of dispersion compensation methods after grating misalignment are shown to mitigate pulse lengthening, limited by temporal contrast degradation and higher-order effects for ultrabroad bandwidths.

47 OTHER INSTRUMENTATION↗

Femtosecond-Terawatt Hard X-Ray Pulse Generation with Chirped Pulse Amplification on a Free Electron Laser

Advances of high intensity lasers have opened up the field of strong field physics and led to a broad range of technological applications. Recent x ray laser sources and optics development makes it possible to obtain extremely high intensity and brightness at x ray wavelengths. In this paper, we present a system design that implements chirped pulse amplification for hard x ray free electron lasers. Numerical modeling with realistic experimental parameters show that near-transform-limit single-femtosecond hard x ray laser pulses with peak power exceeding 1 TW and brightness exceeding 4×10 35 s -1 mm -2 mrad -2 0.1\%bandwdith -1 can be consistently generated. In conclusion, realization of such beam qualities is essential for establishing systematic and quantitative understanding of strong field x-ray physics and nonlinear x ray optics phenomena.

47 OTHER INSTRUMENTATION↗

Injection laser system for Advanced Radiographic Capability using chirped pulse amplification on the National Ignition Facility

We report on the design, performance, and qualification of the injection laser system designed to deliver joule-level chirped pulse beamlets arranged in dual rectangular beam formats into two main laser amplifier beamlines of the National Ignition Facility. The system is designed to meet the requirements of the Advanced Radiographic Capability upgrade with features that deliver performance, adjustability, and long-term reliability.

47 OTHER INSTRUMENTATION↗

Methodology for designing grism stretchers for idler-based optical parametric chirped-pulse-amplification systems

Powerful ultrafast lasers with wavelengths above 1 mm are in demand to create attosecond pulses and ultra-intense laser sources. A promising technology to achieve these laser sources uses the by-product from an optical parametric chirped-pulse amplifier, known as the idler. Compression of the idler to high peak powers requires a grism stretcher and a grating compressor. Grism stretchers have many more design parameters than conventional stretchers, complicating the design process. This paper presents a method for designing a grism stretcher and grating compressor that logically navigates the design process. This method was applied to design a grism stretcher for the optical parametric amplifier line that is under construction at the Laboratory for Laser Energetics to produce a 50-mJ, 115-fs pulse at 1170 nm.

47 OTHER INSTRUMENTATION↗

Burst-mode chirped pulse amplification method

A method for increasing the MeV hot electron yield and secondary radiation produced by short-pulse laser-target interactions with an appropriately high or low atomic number (Z) target. Secondary radiation, such as MeV x-rays, gamma-rays, protons, ions, neutrons, positrons and electromagnetic radiation in the microwave to sub-mm region, can be used, e.g., for the flash radiography of dense objects.

Bude, Jeffrey D.↗

Control of Brillouin short-pulse seed amplification by chirping the pump pulse

Seed amplification via Brillouin backscattering of a long pump pulse is considered. Similar to Raman amplification, several obstructive effects may occur during short-pulse Brillouin amplification. One is the spontaneous Raman backscattering of the pump before interacting with the seed. Preforming the plasma and/or chirping the pump will reduce unwanted pump backscattering. Optimized regions for low-loss pump propagation were proposed already in conjunction with Raman seed amplification. Hence, the influence of the chirp of the pump during Brillouin interaction with the seed becomes important and will be considered here. Both, the linear as well as the nonlinear evolution phases of the seed caused by Brillouin amplification under the action of a chirped pump are investigated. The amplification rate as well as the seed profiles are presented as function of the chirping rate. Also the dependence of superradiant scaling rates on the chirp parameter is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stretchers and compressors for ultra-high power laser systems

This review is concerned with pulse stretchers and compressors as key components of ultra-high power laser facilities that take advantage of chirped-pulse amplification. The potentialities, characteristics, configurations and methods for the matching and alignment of these devices are examined, with particular attention to the history of the optics of ultra-short, ultra-intense pulses before and after 1985, when the chirped-pulse amplification method was proposed, which drastically changed the view of the feasibility of creating ultra-high power laser sources. The review is intended primarily for young scientists and experts who begin to address the amplification and compression of chirped pulses, experts in laser optics and all who are interested in scientific achievements in the field of ultra-high power laser systems. (review)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radioisotope production using lasers: From basic science to applications

The discovery of chirped pulse amplification has led to great improvements in laser technology, enabling energetic laser beams to be compressed to pulse durations of tens of femtoseconds and focused to a few micrometers. Protons with energies of tens of MeV can be accelerated using, for instance, target normal sheath acceleration and focused on secondary targets. Under such conditions, nuclear reactions can occur, with the production of radioisotopes suitable for medical application. The use of high-repetition lasers to produce such isotopes is competitive with conventional methods mostly based on accelerators. In this paper, we study the production of 67Cu, 63Zn, 18F, and 11C, which are currently used in positron emission tomography and other applications. At the same time, we study the reactions 10B(p,α)7Be and 70Zn(p,4n)67Ga to put further constraints on the proton distributions at different angles, as well as the reaction 11B(p,α)8Be relevant for energy production. The experiment was performed at the 1 PW laser facility at Vega III in Salamanca, Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a high purity germanium detector. Our results are in reasonable agreement with numerical estimates obtained following the approach of Kimura and Bonasera [Nucl. Instrum. Methods Phys. Res., Sect. A 637, 164–170 (2011)].

11C↗

Degradation of temporal contrast from post-pedestal interference with a chirped pulse in an optical parametric amplifier

Pre-pedestal generation is observed in a 0.35-PW laser front end coming from a post-pedestal via instantaneous gain and pump depletion in an optical parametric amplifier during chirped-pulse amplification. Generalized simulations show how this effect arises from gain nonlinearity and applies to all optical parametric chirped-pulse–amplification systems with a post-pedestal. An experiment minimizing the effect of B -integral is used to isolate and study the newly observed conversion of a continuous post-pedestal into a continuous pre-pedestal. Matching numerical simulations confirm experimental results and additionally reveal how third-order dispersion largely controls the slope of the generated pre-pedestal.

47 OTHER INSTRUMENTATION↗