Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chromatographic analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Intrinsic Kinetics of Polyethylene Terephthalate Pyrolysis via Micropyrolysis and Multivariate Chromatographic Analysis

This study provides an in-depth investigation of the primary decomposition of polyethylene terephthalate (PET) via pyrolysis, employing an experimental-analytic workflow that integrates design of experiments (DoE), micropyrolysis coupled with comprehensive two-dimensional gas chromatography (GC×GC), and multivariate data analysis to verify intrinsic kinetic conditions and elucidate evolving product distributions for mapping key reaction pathways. Peaks that could not be identified using commercial spectral libraries were assigned using Mass Frontier simulations, enabling the identification of divinyl terephthalate, ethyl vinyl terephthalate, and 2-(benzoyloxy)ethyl vinyl terephthalate. A polar×polar (non-orthogonal) column set tailored for the detection of carboxylic acids enhanced the quantification of benzoic acid, 4-vinylbenzoic acid, 4-ethylbenzoic acid, and methylbenzoic acid by up to 6-fold relative to an orthogonal column combination (non-polar×mid-polar). Moreover, pyrolysis variables were systematically evaluated using a Box- Behnken design (BBD), encompassing pyrolysis temperature (500−600 °C), sample weight (50−150 μg), and carrier gas flow rate (100−300 mL min −1 ). Among these, pyrolysis temperature was the only statistically significant factor influencing product yields, ranging from 58.78 to 84.26 wt %. In contrast, neither the sample weight nor the carrier gas flow rate had a significant effect on product yields within the evaluated experimental space. At 600 °C, the major pyrolysis products were benzoic acid (up to 20.20 ± 1.46 wt %) and CO 2 (up to 21.28 ± 1.46 wt %), which can be produced through decarboxylation reactions. These findings underscore the critical importance of selecting appropriate analytical columns for the accurate quantification of heteroatomcontaining products such as carboxylic acids, which may otherwise be underestimated or undetected due to their reactivity with the stationary phase of non-polar and mid-polar columns, as well as other GC components. They also highlight the importance of selecting pyrolysis conditions for investigating the primary decomposition of PET under an isothermal kinetically limited regime.

aromatic compounds↗

Structural modification of fentanyls for their retrospective identification by gas chromatographic analysis using chloroformate chemistry

Abstract The one-step breakdown and derivatization of a panel of nine fentanyls to yield uniquely tagged products that can be detected by Electron Ionization Gas Chromatography-Mass Spectrometry (EI-GC-MS) is presented. The method involves the treatment of the synthetic opioids with 2,2,2-trichloroethoxycarbonyl chloride (TrocCl) at 60 °C for 3 h in dichloromethane and furnishes two products from one fentanyl molecule that can be used to retrospectively identify the original opioid. Parameters that were studied and fully optimized for the method included temperature, solvent, nature of scavenging base and reaction time. One of the two resulting products from the reaction bears the trichloroethoxycarbonyl (Troc) tag attached to the norfentanyl portion of the original opioid and greatly aids in the opioid detection and identification process. The methodology has been applied to the chemical modification of a panel of nine fentanyls and in all cases the molecular ion peak for the Troc-norfentanyl product bearing the distinctive trichloroethyl isotopic signature can be clearly observed. The method’s LLOD was determined to be 10 ng/mL while its LLOQ was found to be 20 ng/mL. This methodology represents the first application of chloroformates in the chemical modification of this class of synthetic opioids that are notoriously inert to common derivatization strategies available for GC–MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interactions of Jet Fuels with Nitrile O-Rings: Petroleum-Derived versus Synthetic Fuels

A transition from petroleum-derived jet fuels to blends with Fischer-Tropsch (F-T) fuels, and ultimately fully synthetic hydro-isomerized F-T fuels has raised concern about the fate of plasticizers in nitrile-butadiene rubber o-rings that are contacted by the fuels as this transition occurs. The partitioning of plasticizers and fuel molecules between nitrile o-rings and petroleum-derived, synthetic, and additized-synthetic jet fuels has been measured. Thermal desorption of o-rings soaked in the various jet fuels followed by gas chromatographic analysis with a mass spectrometric detector showed many of the plasticizer and stabilizer compounds were removed from the o-rings regardless of the contact fuel. Fuel molecules were observed to migrate into the o-rings for the petroleum-derived fuel as did both the fuel and additive for a synthetic F-T jet fuel additized with benzyl alcohol, but less for the unadditized synthetic fuel. The specific compounds or classes of compounds involved in the partitioning were identified and a semiquantitative comparison of relative partitioning of the compounds of interest was made, The results provide another step forward in improving the confidence level of using additized, fully synthetic jet fuel in the place of petroleum-derived fuel.

02 PETROLEUM↗

Quantification of biogenic volatile organic compounds with a flame ionization detector using the effective carbon number concept

Biogenic volatile organic compounds (BVOCs) are emitted into the atmosphere by plants and include isoprene, monoterpenes, sesquiterpenes, and their oxygenated derivatives. These BVOCs are among the principal factors influencing the oxidative capacity of the atmosphere in forested regions. BVOC emission rates are often measured by collecting samples onto adsorptive cartridges in the field and then transporting these samples to the laboratory for chromatographic analysis. One of the most commonly used detectors in chromatographic analysis is the flame ionization detector (FID). For quantitative analysis with an FID, relative response factors may be estimated using the effective carbon number (ECN) concept. The purpose of this study was to determine the ECN for a variety of terpenoid compounds to enable improved quantification of BVOC measurements. A dynamic dilution system was developed to make quantitative gas standards of VOCs with mixing ratios from 20–55 ppb. For each experiment using this system, one terpene standard was co-injected with an internal reference, n-octane, and analyzed via an automated cryofocusing system interfaced to a gas chromatograph flame ionization detector and mass spectrometer (GC/MS/FID). The ECNs of 16 compounds (14 BVOCs) were evaluated with this approach, with each test compound analyzed at least three times. The difference between the actual carbon number and measured ECN ranged from -24% to -2%. Furthermore, the difference between theoretical ECN and measured ECN ranged from -22% to 9%. Measured ECN values were within 10% of theoretical ECN values for most terpenoid compounds.

47 OTHER INSTRUMENTATION↗

Visible Light Photoreduction of CO{sub 2} Using CdSe/Pt/TiO{sub 2} Heterostructured Catalysts

A series of CdSe quantum dot (QD)-sensitized TiO{sub 2} heterostructures have been synthesized, characterized, and tested for the photocatalytic reduction of CO{sub 2} in the presence of H{sub 2}O. Our results show that these heterostructured materials are capable of catalyzing the photoreduction of CO{sub 2} using visible light illumination (λ > 420 nm) only. The effect of removing surfactant caps from the CdSe QDs by annealing and using a hydrazine chemical treatment have also been investigated. The photocatalytic reduction process is followed using infrared spectroscopy to probe the gas-phase reactants and gas chromatography to detect the products. Gas chromatographic analysis shows that the primary reaction product is CH{sub 4}, with CH{sub 3}OH, H{sub 2}, and CO observed as secondary products. Typical yields of the gas-phase products after visible light illumination (λ>420 nm) were 48 ppm g{sup -1} h{sup -1} of CH{sub 4}, 3.3 ppm g{sup -1} h{sup -1} of CH{sub 3}OH (vapor), and trace amounts of CO and H{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiosynthesis and Biodistribution of {sup 99m}Tc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical

Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of {sup 99m}Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that {sup 99m}Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S&GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S&GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 g/L potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent column breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated-carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 giL potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent adsorption tube breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. Linear response was checked using both non-volatile TOX species (trichlorophenol) and volatile TOX species. Average recoveries of the volatile TOX species ranged between 50% and 75%. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acrolein consumption induces systemic dyslipidemia and lipoprotein modification

Aldehydes such as acrolein are ubiquitous pollutants present in automobile exhaust, cigarette, wood, and coal smoke. Such aldehydes are also constituents of several food substances and are present in drinking water, irrigation canals, and effluents from manufacturing plants. Oral intake represents the most significant source of exposure to acrolein and related aldehydes. To study the effects of short-term oral exposure to acrolein on lipoprotein levels and metabolism, adult mice were gavage-fed 0.1 to 5 mg acrolein/kg bwt and changes in plasma lipoproteins were assessed. Changes in hepatic gene expression related to lipid metabolism and cytokines were examined by qRT-PCR analysis. Acrolein feeding did not affect body weight, blood urea nitrogen, plasma creatinine, electrolytes, cytokines or liver enzymes, but increased plasma cholesterol and triglycerides. Similar results were obtained with apoE-null mice. Plasma lipoproteins from acrolein-fed mice showed altered electrophoretic mobility on agarose gels. Chromatographic analysis revealed elevated VLDL cholesterol, phospholipids, and triglycerides levels with little change in LDL or HDL. NMR analysis indicated shifts from small to large VLDL and from large to medium-small LDL with no change in the size of HDL particles. Increased plasma VLDL was associated with a significant decrease in post-heparin plasma hepatic lipase activity and a decrease in hepatic expression of hepatic lipase. These observations suggest that oral exposure to acrolein could induce or exacerbate systemic dyslipidemia and thereby contribute to cardiovascular disease risk.

60 APPLIED LIFE SCIENCES↗

Paranitrophenol liquid-phase adsorption in dealuminated Y zeolite

Was studied the liquid-phase paranitrophenol (PNP) dynamic adsorption in a packed bed adsorption reactor (PBAR), filled with dealuminated Y zeolite (DAY) and granulated active carbon (GAC). In addition, was measured the equilibrium maximum amount of adsorption for the system: PNP aqueous solution DAY zeolite, at 300 K, to compare it with other adsorbents. The DAY zeolite and the GAC were characterized with adsorption methods. The DAY zeolite was, as well, characterized with: XRD, SEM and EDAX. Some of the operational parameters which characterize the performance of the PBAR were calculated. To evaluate these results, was considered the breakthrough experiment as a frontal analysis chromatographic event and were applied the DeVault and van Deemter equations. It was concluded that the reactor filled with the DAY zeolite operates more efficiently than those filled with the GAC, because of the stronger adsorbate adsorbent interaction in the case of the DAY zeolite.

adsorption, paranitrophenol, DAY↗

Vinyl monomers-induced synthesis of polyvinyl alcohol-stabilized selenium nanoparticles

A simple wet chemical method has been developed to synthesize selenium nanoparticles (size 100-200 nm), by reaction of sodium selenosulphate precursor with different vinyl monomers, such as acrylamide, N,N'-dimethylene bis acrylamide, methyl methacrylate, sodium acrylate, etc., in aqueous medium, under ambient conditions. Polyvinyl alcohol has been used to stabilize the selenium nanoparticles. Average size of the synthesized selenium nanoparticles can be controlled by adjusting concentration of both the precursors and the stabilizer. Rate of the reaction as well as size of the resultant selenium nanoparticles have been correlated with the functional groups of the different monomers. UV-vis optical absorption spectroscopy, X-ray diffraction, energy dispersive X-rays, differential scanning calorimetry, atomic force microscopy, scanning electron microscopy and transmission electron microscopy techniques have been employed to characterize the synthesized selenium nanoparticles. Gas chromatographic analysis of the reaction mixture established the non-catalytic role of the vinyl monomers, which were found to be consumed during the course of the reaction.

36 MATERIALS SCIENCE↗

Sub-micrometer sized yttrium oxide fibers prepared through hydrothermal reaction

Research highlights: {yields} Y{sub 2}O{sub 3} fibers were synthesized by hydrothermal reaction followed by calcination. {yields} Y(OH){sub x}Cl{sub 3-x}.yH{sub 2}O was received from hydrothermal reaction. {yields} Y{sub 2}O{sub 3} fibers showed outstanding high-temperature stability. -- Abstract: Yttrium oxide fibers have been synthesized via hydrothermal reaction and subsequent thermal treatment using yttrium chloride as precursor. The products before and after the thermal treatment were characterized by powder X-ray diffractions (XRD), scanning electron microscopy (SEM), ion-chromatograph analysis, and thermogravimetry and differential thermal analysis (TG-DTA). The fiber diameter ranged from 100 to 300 nm, while the length was up to tens of microns. It was found that the chemical composition and morphology of the products were closely related to the pH value of reaction solution, and fibrous products could be obtained at pH 9.5-10.25. These oxide fibers exhibited outstanding high-temperature stability, which maintained their morphology at temperature up to 1400 {sup o}C.

36 MATERIALS SCIENCE↗

Modified normal-phase ion-pair chromatographic methods for the facile separation and purification of imidazolium-based ionic compounds

lmidazolium- and oligo(imidazolium)-based ionic organic compounds are important in the design of room-temperature ionic liquid materials; however, the chromatographic analysis and separation of such compounds are often difficult. A convenient and inexpensive method for effective thin-layer chromatography (TLC) analysis and column chromatography separation of imidazolium-based ionic compounds is presented. Normal-phase ion-pair TLC is used to effectively analyze homologous mixtures of these ionic compounds. Subsequent separation of the mixtures is performed using ion-pair flash chromatography on normal-phase silica gel, yielding high levels of recovery. This method also results in a complete exchange of the counter anion on the imidazolium compounds to the anion of the ion-pair reagent. (C) 2012 Elsevier Ltd. All rights reserved.

Urban, ND↗

Structure and Ligand-Binding Mechanism of a Cysteinyl Leukotriene-Binding Protein from a Blood-Feeding Disease Vector

Blood-feeding disease vectors mitigate the negative effects of hemostasis and inflammation through the binding of small-molecule agonists of these processes by salivary proteins. In this study, a lipocalin protein family member (LTBP1) from the saliva of Rhodnius prolixus, a vector of the pathogen Trypanosoma cruzi, is shown to sequester cysteinyl leukotrienes during feeding to inhibit immediate inflammatory responses. Calorimetric binding experiments showed that LTBP1 binds leukotrienes C 4 (LTC 4 ), D 4 (LTD 4 ), and E 4 (LTE 4 ) but not biogenic amines, adenosine diphosphate, or other eicosanoid compounds. Crystal structures of ligand-free LTBP1 and its complexes with LTC 4 and LTD 4 reveal a conformational change during binding that brings Tyr114 into close contact with the ligand. LTC 4 is cleaved in the complex, leaving free glutathione and a C 20 fatty acid. As a result, chromatographic analysis of bound ligands showed only intact LTC 4 , suggesting that cleavage could be radiation-mediated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and Evaluation of Fluorophore-Doped Polymer Substrates to Screen for Plastic-Degrading Enzymes

Fast and sensitive analytical methods are the key to efficient screening of plastic-degrading enzymes. Here, we present a streamlined and affordable approach to assess the enzymatic deconstruction of insoluble synthetic polymers by blending them with a fluorescent dye, rhodamine 6G, and we evaluate this screening method using poly(ethylene terephthalate) (PET) as a model material. Our results indicate that enzymatic depolymerization of the rhodamine-doped PET can be observed in a high-throughput fashion by following release of the fluorophore. The fluorescence data obtained during the hydrolysis of rhodamine-doped PET by 14 PET hydrolases, produced with a robotic platform, correlated with the quantitative chromatographic analysis of PET degradation products. Remarkably, the use of the rhodamine-loaded PET substrate resulted in negligibly low background signals even when detecting PETase activity in crude cell lysates, suggesting suitability for screening of a wide variety of samples. Encouraged by these results, we next produced a selection of polyethylene- and nylon-based materials loaded with rhodamine 6G. While rapid leaching of fluorophore observed with nylon substrates limits the utility of the method for detecting nylonase activity, the rhodamine-loaded polyethylene showed promising performance in passive diffusion tests, indicating that this latter substrate may be used to screen for polyolefin-degrading enzymes.

09 BIOMASS FUELS↗

Examination of arsenic speciation in sulfidic solutions using x-ray absorption spectroscopy.

Both thioarsenites and thioarsenates have been demonstrated to exist in sulfidic waters, yet there is uncertainty regarding the geochemical conditions that govern the formation of these arsenic species. The purpose of this research was to use advanced spectroscopy techniques, speciation modeling, and chromatography to elucidate the chemical speciation of arsenic in sulfidic solutions initially containing arsenite and sulfide. Results of X-ray absorption spectroscopy (XAS) show that experimental solutions contained mixtures of arsenite and thioarsenites with increasing substitution of sulfur for oxygen on arsenic as the sulfide concentration increased. Experimental samples showed no evidence of polymeric arsenic species, or transformation of thioarsenites to thioarsenates. The arsenic speciation measured using XAS was similar to predictions obtained from a thermodynamic model for arsenic speciation, excluding thioarsenate species in sulfidic systems. Our data cast some doubt on the application of chromatographic methods for determining thioarsenates and thioarsenites (or mixtures) in natural waters in cases where the arsenic oxidation state cannot be independently verified. The same chromatographic peak positions proposed for thioarsenates can be explained by thioarsenite species. Furthermore, sample dilution was shown to change the species distribution and care should be taken to avoid sample dilution prior to chromatographic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗