Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chromatography, Gas/instrumentation/methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A new method for the preparation of polymeric porous layer open tubular columns for GC application

A new method to prepare polymeric PLOT columns by using in situ polymerization technology is described. The method involves a straightforward in situ polymerization of the monomer. The polymer produced is directly coated on the metal tubing. This eliminates many of the steps needed in conventional polymeric PLOT column preparation. Our method is easy to operate and produces very reproducible columns, as shown previously (T. C. Shen. J. Chromatogr. Sci. 30, 239, 1992). The effects of solvents, tubing pretreatments, initiators and reaction temperatures in the preparation of PLOT columns are studied. Several columns have been developed to separate (1) highly polar compounds, such as water and ammonia or water and HCN, and (2) hydrocarbons and inert gases. A recent improvement has allowed us to produce bonded polymeric PLOT columns. These were studied, and the results are included also.

NASA Discipline Exobiology↗

In-situ polymerization PLOT columns I: divinylbenzene

A novel method for preparation of porous-layer open-tubular (PLOT) columns is described. The method involves a simple and reproducible, straight-forward in-situ polymerization of monomer directly on the metal tube.

NASA Center ARC↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

Development of a modulator to measure water vapor selectively in a gaseous mixture

Selective thermal modulation (STM) is a technique which produces a concentration-dependent pulse by selectively modulating a sample in a gas stream. Several types of modulation techniques, both chemical and physical, using adsorption, decomposition, and catalytic and mechanical methods have been developed for use with multiplex gas chromatography. Two of these applications involve selective modulation of the components present in the sample gas stream. The selective modulation of the concentration of specific sample molecules or classes of molecules provides additional analytical selectivity which can lead to selective detection. For some specific applications, the column may even be eliminated. Chemical modulation by absorption of a substance from the sample stream by a stationary phase will also produce a change in the signal intensity. Removal of a substance from the sample stream results in a signal containing a vacancy peak. In the work reported here, a selective thermal modulation technique has been developed as a method for determination of water vapor for possible use in Mars' atmosphere.

NASA Center ARC↗

Gas chromatographic column for the storage of sample profiles

The concept of a sample retention column that preserves the true time profile of an analyte of interest is studied. This storage system allows for the detection to be done at convenient times, as opposed to the nearly continuous monitoring that is required by other systems to preserve a sample time profile. The sample storage column is essentially a gas chromatography column, although its use is not the separation of sample components. The functions of the storage column are the selective isolation of the component of interest from the rest of the components present in the sample and the storage of this component as a function of time. Using octane as a test substance, the sample storage system was optimized with respect to such parameters as storage and readout temperature, flow rate through the storage column, column efficiency and storage time. A 3-h sample profile was collected and stored at 30 degrees C for 20 h. The profile was then retrieved, essentially intact, in 5 min at 130 degrees C.

NASA Program Exobiology↗

Gas chromatography in space

Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

Review, Tutorial↗