Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clock Agreement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Clock Agreement Among Parallel Supercomputer Nodes

This dataset presents measurements that quantify the clock synchronization time-agreement characteristics among several high performance computers including the current world's most powerful machine for open science, the U.S. Department of Energy's Titan machine sited at Oak Ridge National Laboratory. These ultra-fast machines derive much of their computational capability from extreme node counts (over 18000 nodes in the case of the Titan machine). Time-agreement is commonly utilized by parallel programming applications and tools, distributed programming application and tools, and system software. Our time-agreement measurements detail the degree of time variance between nodes and how that variance changes over time. The dataset includes empirical measurements and the accompanying spreadsheets.

97 MATHEMATICS AND COMPUTING↗

High-fidelity imaging of a band insulator in a three-dimensional optical lattice clock

Here, we report on the observation of a high-density, band insulating state in a three-dimensional optical lattice clock. Filled with a nuclear-spin-polarized degenerate Fermi gas of 87 Sr, the three-dimensional (3D) lattice has one atom per site in the ground motional state, thus guarding against frequency shifts due to contact interactions. At this high density where the average distance between atoms is comparable to the probe wavelength, conventional imaging techniques at saturation intensity suffer from large systematic errors. To spatially probe frequency shifts in the clock and measure thermodynamic properties of this system, accurate imaging techniques at high optical depths are required. Using a combination of highly saturated fluorescence and absorption imaging, we confirm the density distribution in our 3D optical lattice in agreement with a single spin band insulating state. Combining our clock platform with this high filling fraction opens the door to studying new classes of long-lived, many-body states arising from dipolar interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An evaluation of the state of time synchronization on leadership class supercomputers

We present a detailed examination of time agreement characteristics for nodes within extreme-scale parallel computers. Using a software tool we introduce in this paper, we quantify attributes of clock skew among nodes in three representative high-performance computers sited at three national laboratories. Our measurements detail the statistical properties of time agreement among nodes and how time agreement drifts over typical application execution durations. We discuss the implications of our measurements, why the current state of the field is inadequate, and propose strategies to address observed shortcomings.

97 MATHEMATICS AND COMPUTING↗

Cross-platform comparison of arbitrary quantum states

As we approach the era of quantum advantage, when quantum computers (QCs) can outperform any classical computer on particular tasks, there remains the difficult challenge of how to validate their performance. While algorithmic success can be easily verified in some instances such as number factoring or oracular algorithms, these approaches only provide pass/fail information of executing specific tasks for a single QC. On the other hand, a comparison between different QCs preparing nominally the same arbitrary circuit provides an insight for generic validation: a quantum computation is only as valid as the agreement between the results produced on different QCs. Such an approach is also at the heart of evaluating metrological standards such as disparate atomic clocks. In this paper, we report a cross-platform QC comparison using randomized and correlated measurements that results in a wealth of information on the QC systems. We execute several quantum circuits on widely different physical QC platforms and analyze the cross-platform state fidelities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A scalable, fully implicit algorithm for the reduced two-field low-β extended MHD model

Here, we demonstrate a scalable fully implicit algorithm for the two-field low-β extended MHD model. This reduced model describes plasma behavior in the presence of strong guide fields, and is of significant practical impact both in nature and in laboratory plasmas. The model displays strong hyperbolic behavior, as manifested by the presence of fast dispersive waves, which make a fully implicit treatment very challenging. In this study, we employ a Jacobian-free Newton–Krylov nonlinear solver, for which we propose a physics-based preconditioner that renders the linearized set of equations suitable for inversion with multigrid methods. As a result, the algorithm is shown to scale both algorithmically (i.e., the iteration count is insensitive to grid refinement and timestep size) and in parallel in a weak-scaling sense, with the wall-clock time scaling weakly with the number of cores for up to 4096 cores. For a 4096 × 4096 mesh, we demonstrate a wall-clock-time speedup of ~6700 with respect to explicit algorithms. The model is validated linearly (against linear theory predictions) and nonlinearly (against fully kinetic simulations), demonstrating excellent agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum nonlocal modulation cancelation with distributed clocks

We demonstrate nonlocal modulation of entangled photons with truly distributed radio frequency (RF) clocks. Leveraging a custom radio-over-fiber (RFoF) system characterized via classical spectral interference, we validate its effectiveness for quantum networking by multiplexing the RFoF clock with one photon from a frequency-bin-entangled pair and distributing the coexisting quantum-classical signals over fiber. Phase modulation of the two photons reveals nonlocal correlations in excellent agreement with theory: in-phase modulation produces additional sidebands in the joint spectral intensity, while out-of-phase modulation is nonlocally canceled. Our simple, feedback-free design attains subpicosecond synchronization—namely, drift less than ~0.5 ps in a 5.5 km fiber over 30 min (fractionally only ~2×10 -8 of the total fiber delay)—and should facilitate frequency-encoded quantum networking protocols such as high-dimensional quantum key distribution and entanglement swapping, unlocking frequency-bin qubits for practical quantum communications in deployed metropolitan-scale networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separable into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.

07 ISOTOPE AND RADIATION SOURCES↗

c-HAND: near real-time coastal flood mapping

The Texas Gulf Coast region contains significant centers of population, infrastructure, and economy and is threatened by intensifying tropical storms. The flooding from these tropical storms often has multiple compounding drivers. This characteristic presents a complex numerical problem where a simulation must consider multiple hydrologic forcings. While several procedures exist for addressing this problem numerically, they tend to be resource-intensive and cannot be conducted in near real-time. We extend GeoFlood, a reduced physics approach for fluvial flood forecasting, to rapidly predict coastal and compound fluvial-coastal inundation. This method is validated against a numerical ocean circulation model (ADCIRC) simulation of Hurricane Ike, a major coastal flooding event that happened on the Texas Gulf Coast in 2008. We show that the inundation map generated by coastal HAND (c-HAND) has reasonable agreement with the ADCIRC simulation while taking about 1.7% of the time currently needed to run ADCIRC on a supercomputer. While our model correctly predicts 99% of ADCIRC-inundated DEM cells, it also overpredicts inundated area by a factor of approximately 27%. We combine c-HAND with the GeoFlood framework for fluvial flood forecasting to create a compound fluvial-coastal inundation mapping workflow that can be run in near real-time. c-HAND's fast wall-clock time and low CPU requirements can support decision making by first response personnel. The method provides timely and convenient access to crucial information, such as the locations of flooded roads and inundated coastal areas.

42 ENGINEERING↗

Deep learning for NLTE spectral opacities

Computer simulations of high energy density science experiments are computationally challenging, consisting of multiple physics calculations including radiation transport, hydrodynamics, atomic physics, nuclear reactions, laser–plasma interactions, and more. To simulate inertial confinement fusion (ICF) experiments at high fidelity, each of these physics calculations should be as detailed as possible. However, this quickly becomes too computationally expensive even for modern supercomputers, and thus many simplifying assumptions are made to reduce the required computational time. Much of the research has focused on acceleration techniques for the various packages in multiphysics codes. In this work, we explore a novel method for accelerating physics packages via machine learning. The non-local thermodynamic equilibrium (NLTE) package is one of the most expensive calculations in the simulations of indirect drive inertial confinement fusion, taking several tens of percent of the total wall clock time. We explore the use of machine learning to accelerate this package, by essentially replacing the physics calculation with a deep neural network that has been trained to emulate the physics code. Overall, we demonstrate the feasibility of this approach on a simple problem and perform a side-by-side comparison of the physics calculation and the neural network inline in an ICF Hohlraum simulation. We show that the neural network achieves a 10× speed up in NLTE computational time while achieving good agreement with the physics code for several quantities of interest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical clocks: using otolith geochemistry to enhance estimation of age and growth of white hake (Urophycis tenuis)

The white hake (Urophycis tenuis) is a groundfish distributed throughout the Gulf of Maine. Catch advice is based on stock assessments done with age-based population dynamics models; however, otolith aging is challenging because of unclear growth increments. To address this concern, we compared the consistency of aging with counts of visual annuli to that of aging with cycles of elemental concentrations measured by using laser ablation inductively coupled plasma mass spectrometry. We tested the hypothesis that oscillations in both environmental conditions and internal physiology through time influence uptake of elements during otolith mineralization. Concentrations of manganese, in comparison with those of the other investigated trace elements (magnesium, strontium, and barium), had the most promising correlation with visual growth increments (~100% age agreement, ±1 year), offering an additional tool to enhance increment identification. In our examination of 550 otoliths collected during 2007–2021, we found that white hake lived a maximum of 10.3 years and exhibited sexual dimorphism in maximum length and age. By using generated von Bertalanffy growth functions, L(t)=110(1–e–0.113(t+0.45)) for males and L(t)=140(1–e–0.113(t–0.30)) for females (where L(t) is length at time t), size and age at maturity were calculated for males (37.4 cm in total length (TL), 3.3 years) and females (47.4 cm TL, 4.2 years). These results demonstrate that otolith geochemistry can be used to improve the accuracy and precision of the estimation of fish age and maturity, even for challenging species.

59 BASIC BIOLOGICAL SCIENCES↗

Clocking Femtosecond Collisional Dynamics via Resonant X-Ray Spectroscopy

Electron-ion collisional dynamics is of fundamental importance in determining plasma transport properties, nonequilibrium plasma evolution, and electron damage in diffraction imaging applications using bright x-ray free-electron lasers (FELs). Here in this paper, we describe the first experimental measurements of ultrafast electron impact collisional ionization dynamics using resonant core-hole spectroscopy in a solid-density magnesium plasma, created and diagnosed with the Linac Coherent Light Source x-ray FEL. By resonantly pumping the 1s → 2p transition in highly charged ions within an optically thin plasma, we have measured how off-resonance charge states are populated via collisional processes on femtosecond time scales. We present a collisional cross section model that matches our results and demonstrates how the cross sections are enhanced by dense-plasma effects including continuum lowering. Nonlocal thermodynamic equilibrium collisional radiative simulations show excellent agreement with the experimental results and provide new insight on collisional ionization and three-body-recombination processes in the dense-plasma regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width of 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predictions of Yield Strength Evolution Due to Physical Aging of 828 DGEBA/DEA using the Simplified Potential Energy Clock Model

The capability of the Simplified Potential Energy Clock Model (SPEC) to represent the uniaxial compression yield strength evolution under isothermal aging conditions is evaluated for a widely used epoxy thermoset encapsulation material, 828 DGEBA/DEA. A baseline model calibration is used. We note that this calibration did not consider yield strength behavior close to the glass transition temperature ( T g ), but in this work, the model is exercised in this temperature range to evaluate the ability to predict changes in material response with aging as equilibrium is approached. Some model alterations were needed to remove negative Prony weights in the thermal and bulk relaxation function ( f 1 ), which is chiefly responsible for aging in this analysis, but otherwise, the model was not altered. Model predictions of yield stress evolution are quantitatively different compared with experiments, but the rate of change of yield stress with respect to aging time is in reasonable agreement with respect to experiments for the first 1000 hours of aging. After this aging time, the measured yield stress stops evolving, but the model continues to evolve for several more decades in time. Parametric studies and model alterations are considered to investigate how yield strength evolution predictions are affected by modeling choices. It is clear that the baseline calibration must be re-examined in order to represent the aging data quantitatively.

42 ENGINEERING↗

Sub-Doppler Cooling of a Trapped Ion in a Phase-Stable Polarization Gradient

Trapped ions provide a highly controlled platform for quantum sensors, clocks, simulators, and computers, all of which depend on cooling ions close to their motional ground state. Existing methods like Doppler, resolved sideband, and dark resonance cooling balance trade-offs between the final temperature and cooling rate. A traveling polarization gradient has been shown to cool multiple modes quickly and in parallel, but utilizing a stable polarization gradient can achieve lower ion energies, while also allowing tailorable light-matter interactions in the sub-wavelength regime. In this Letter, we demonstrate cooling of a trapped ion below the Doppler limit using a phase-stable polarization gradient created using trap-integrated photonic devices. At an axial frequency of 2⁢𝜋×1.45 MHz we achieve ⟨𝑛⟩=1.56±0.07 in 150 μ⁢s and cooling rates of ∼0.3 quanta/μ⁢s. Here, we examine ion dynamics under different polarization gradient phases, detunings, and intensities, showing reasonable agreement between experimental results and a multilevel model. Cooling is fast and power efficient, with lower average motional Fock state occupation when compared to simulated operation under the corresponding running wave configuration. Our results demonstrate a well-controlled test bed for studying the dynamics of multilevel atomic systems in a phase-stable polarization gradient.

Atom & ion cooling↗

Electronic structure, molecular orientation, charge transfer dynamics and solar cells performance in donor/acceptor copolymers and fullerene: Experimental and theoretical approaches

By combining experimental and theoretical approaches, the electronic structure, molecular orientation, charge transfer dynamics and solar cell performance in donor/acceptor copolymer poly[2,7-(9,9-bis(2-ethylhexyl)-dibenzosilole)-alt-4,7-bis(thiophen-2-yl) benzo-2,1,3-thiadiazole] (PSiF-DBT) films and blended with 6,6.-phenyl-C 61-butyric acid methyl ester (PSiF-DBT:PCBM) were investigated. Good agreement between experimental and theoretical PSiF-DBT UV-Vis absorption spectrum is observed and the main molecular orbitals contributing to the spectrum were determined using DFT single point calculations. Non-coplanar configuration was determined by geometric optimization calculation in isolated PSiF-DBT pentamer and corroborated by angular variation of the sulphur 1s near-edge X-ray absorption fine structure (NEXAFS) spectra. Edge-on and plane-on molecular orientations were obtained for thiophene and benzothiadiazole units, respectively. A power conversion efficiency up to 1.58%, open circuit voltage of 0.51 V, short circuit current of 8.71 mA/cm{sup 2} and a fill factor of 35% was obtained using blended PSiF-DBT:PCBM as active layer in a bulk heterojunction solar cell. Ultrafast electron dynamics in the low-femtosecond regime was evaluated by resonant Auger spectroscopy using the core-hole clock methodology around sulphur 1s absorption edge. Electron delocalization times for PSiF-DBT and PSiF-DBT:PCBM polymeric films were derived for selected excitation energies corresponding to the main transitions in the sulphur 1s NEXAFS spectra. The mixture of PSiF-DBT with PCBM improves the charge transfer process involving the π* molecular orbital of the thiophene units.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An OpenMP GPU-offload implementation of a non-equilibrium solidification cellular automata model for additive manufacturing

Here, in this paper, performance strategies on GPU-based HPC platforms of a cellular automata (CA) simulation code for non-equilibrium solidification, including nucleation, grain growth, solute partitioning and transport for the metal additive manufacturing (AM) process are investigated using OpenMP 4.5. To accurately report the speed-up for multicore CPUs and GPUs, a rigorous performance analysis employed optimizations appropriate for both CPU-only code (baseline) and GPU offload codes for an isothermal test problem. The performance results on Summit at the Oak Ridge Leadership Computing Facility indicate that using a precomputed list of interface cells significantly decreased the wall-clock time on GPUs. The speedup due to GPU acceleration was evaluated for a full Summit node and measured to be 1.8X when comparing a 6 MPI tasks run with 6 GPUs versus 36 MPI tasks on the CPU only. That speed-up was found to be 7.9X when comparing 6 MPI tasks with 6 GPUs versus the 6 MPI tasks running on the CPU only. Performance measurements showed that system total time is almost constant for runs with more than 96 MPI tasks (or GPUs), indicating that the GPU-accelerated code showed an excellent weak scaling performance. Finally, a rapid directional solidification problem was considered to demonstrate the CA code capability on Summit. It was found that a mesh size of at least 0.05 μm is recommended for the AM-like simulations in order to obtain accurate elongated grain microstructure and elongated subgrain features, which are in qualitative good agreement with experimental data. The results presented in this study indicate that the performance strategies on GPU-based HPC platforms for the CA code are appropriate for novel HPC exascale platforms.

36 MATERIALS SCIENCE↗

SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗