Search NASA⌕ Search

SEARCH · Search NASA

Results for “Co-Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Incorporating Elevation in Traffic-Vehicle CO-Simulation: Issues, Impacts, and Solutions

Traffic-vehicle co-simulation couples microscopic traffic simulation with full-body vehicle dynamics to assess system-level impacts on mobility, energy, and safety with greater realism. Incorporating elevation is critical for accurately modeling vehicle behavior and energy use, especially for gradient-sensitive vehicles such as electric and heavy-duty trucks. However, raw elevation data often contain noise, discontinuities, and inconsistencies. While such issues may be negligible in traditional traffic simulations, they significantly affect traffic-vehicle co-simulations where vehicle dynamics are sensitive to road grade variations. This paper investigates the impact of unprocessed elevation data on vehicle behavior and energy consumption using a 42-mile simulation along Interstate 81. We propose an elevation processing workflow that can mitigate the effects stem from elevation data issues, improving the realism and stability of traffic-vehicle co-simulation. Results show that the method effectively removes noise and abrupt elevation transitions while preserving roadway geometry.

Xu, Guanhao [ORNL] (ORCID:0000000214326357)↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

Co-Simulation Meets AI: MCP-Driven Power System Analysis

GridGPT, a fine-tuned Generative AI model is designed for on-premise use in grid control rooms. This presentation will demonstrate how eGridGPT can seamlessly integrate with control room solutions to offer operators, engineers, and corporate users enhanced guidance and decision support. It is to show how this innovative AI solution can improve state estimation, boost variable energy forecasting, and optimize grid operations. By leveraging eGridGPT's unique features, audience will learn to unlock new levels of automation, predictive analytics, and reliability within their power systems, ultimately leading to reduced downtime and improved operational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Entity Simulation with CoSim Toolbox

Co-simulation is an analysis technique for linking multiple software models during runtime by facilitating data exchange and simulation time synchronization. There are numerous challenges when constructing an effective co-simulation including simulation tool installation, data management, and writing new models in a manner compatible with the co-simulation framework of choice. CoSim Toolbox is an integration of multiple pieces of software designed to make assembling such a co-simulation in HELICS easier. This report summarizes the existing capabilities of CoSim Toolbox and outlines future development plans.

97 MATHEMATICS AND COMPUTING↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A methodology for domain overlapping coupling of thermal-hydraulic systems

Multi-scale coupling has increasingly drawn attention as a promising approach for modeling thermal systems. Traditional system codes provide fast and robust predictions at the plant scale, while high-fidelity computational fluid dynamics (CFD)-based tools resolve localized flow and heat transfer phenomena with greater accuracy. By combining these complementary strengths, co-simulations enable multi-scale analysis that would otherwise be computationally prohibitive for a standalone CFD code. Here, this work introduces a robust and problem-agnostic domain overlapping (DO) coupling between the system thermal-hydraulic (STH) code System Analysis Module (SAM) and the coarse-mesh CFD code Pronghorn. Both applications belong to the Comprehensive Reactor Analysis Bundle (BlueCRAB) code suite, a code suite in active development at the Idaho National Laboratory (INL), tailored for multi-physics analysis of advanced reactors. Unlike previous approaches, BlueCRAB supports an agnostic interface between codes based on different fidelity, while its coupling formulation can address arbitrary flow geometries with multiple inlets and outlets in coupled components. The implemented method leads to consistent pressure drops, enthalpies, and scalar concentrations between coupled SAM and Pronghorn simulations. The methodology is demonstrated through two verification tests, which ensure the numerical consistency and conservation across the codes, and through one validation test against experimental data. The proposed problems explore different physical aspects inherent to thermal systems, with particular attention given to nuclear reactor analysis. These include buoyancy-driven flows, complex flow patterns, and setups with multiple inlets and outlets, representing challenges in advanced reactor applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Distributed optimization and control for autonomous distributed energy resource power dispatch and frequency regulation considering communication failures

Distributed energy resources (DERs) can significantly enhance grid flexibility by supplying power and secondary frequency regulation (SFR) services. Yet, their large number and dispersed nature limit the effectiveness of traditional centralized power dispatch and frequency control schemes, and expose the system to single-point communication failures. This paper presents a unified distributed optimization and control framework for DER power dispatch and SFR provision. A transmission-loss-aware distributed direct current optimal power flow is first formulated to optimize DER power dispatch and reserve scheduling. On top of this, a fully distributed control scheme for DER autonomous SFR provision is developed to allocate automatic generation control signals cost-effectively while ensuring robustness to communication link disruptions. The framework is validated on IEEE 14-bus and 39-bus transmission systems with large-scale distribution feeders using transmission-distribution dynamic co-simulation, demonstrating reliable and autonomous DER power dispatch and SFR provision under diverse operating conditions and communication contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative On-Ramp Merging with Time-Varying Vehicle-to-Vehicle Communication Delay Compensation via a Model-Free Approach

Cooperative merging strategies enabled by vehicle-to-vehicle (V2V) communication have shown promise in addressing congestion, fuel inefficiency, and collision risks. However, their performance can be severely degraded by time-varying and uncertain communication delays-an issue often overlooked in existing research, which primarily focuses on merging sequence determination and trajectory planning. Furthermore, practical considerations such as heterogeneous vehicle dynamics, varying road conditions, and real-time implementation complexities are frequently neglected. This paper presents a model-free, online planning framework for cooperative on-ramp merging of connected and automated vehicles (CAVs), explicitly accounting for time-varying V2V communication delays. Without relying on detailed vehicle dynamics, the proposed method introduces a data-driven delay compensation scheme. A co-simulation platform integrating high-fidelity vehicle dynamics, traffic simulation (SUMO), and V2V communication within MATLAB/Simulink is developed to evaluate the proposed method. Simulation results demonstrate that unaddressed V2V communication delays significantly impair merging performance. In contrast, the proposed framework enhances intervehicle distance tracking and maintains low CO2 emissions and fuel consumption, under communication delay across different communication frequencies. In conclusion, its lightweight design also facilitates real-time implementation, making it well-suited for deployment in practical CAV systems.

Accounting↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiphysics and Multiscale Simulation Methods for Electromagnetic Energy Assisted Fossil Fuel to Hydrogen Conversion (Final Scientific/Technical Report)

This report summarizes the technical accomplishments of the four-year research project “Multiphysics and Multiscale Simulation Methods for Electromagnetic Energy Assisted Fossil Fuel to Hydrogen Conversion” (Award No. DE-FE0032092), conducted at Howard University and the University of Houston (subawardee) from September 2021 to August 2025. The project successfully achieved all four major objectives: 1. 3D Structural Characterization – Developed 3D optical imaging and mechanical sectioning methods to characterize catalyst distribution and support morphology in nickel foam substrates. Successfully reconstructed 3D geometries and imported them into COMSOL Multiphysics for electromagnetic simulations. 2. EM Hotspot Simulation – Created all-frequency stable electromagnetic formulations and 3D nodal discontinuous Galerkin (NDG) methods for coupled electromagnetic-thermal-fluid problems in multiscale catalytic media. Demonstrated stable solutions from DC to microwave frequencies. 3. Multiphysics Coupling – Developed multiscale simulation methods coupling FEM electromagnetic solvers with thermal transport equations. Reactive molecular dynamics (ReaxFF MD) simulations were performed to investigate catalytic reaction mechanisms at the atomistic level. Demonstrated electromagnetic-thermal co-simulation capabilities for porous catalyst structures. 4. System Optimization – Designed and optimized EM-assisted catalytic systems using nickel foam and carbon foam structures, demonstrating significant temperature increases due to microwave heating. Observed and characterized plasma generation in carbon fiber catalysts. Investigated multiple reaction chamber geometries for improved microwave energy deposition. The project produced significant scientific contributions including 15+ peer-reviewed publications, trained multiple Ph.D. students and undergraduate researchers, and advanced the understanding of microwave-assisted hydrogen production from fossil fuels.

08 HYDROGEN↗

Systems-To-Atoms (S2A): enabling hydrogen for climate security

The project addresses a critical gap in hydrogen infrastructure by integrating system-level energy models with atomic-scale material simulations in a unified Systems-to-Atoms (S2A) framework. The motivation stems from the need to develop efficient, cost-effective, and durable hydrogen transport and utilization technologies to support decarbonization of hard-to-electrify sectors such as heavy-duty transportation. Current system models lack awareness of material performance mechanisms, while material-scale models do not account for system-level usage and variability. To bridge this divide, the team developed a co-simulation capability linking techno-economic analyses, reactor/process-flow modeling, and molecular-scale catalysis simulations. Applied to hydrogen delivery in California, the framework enabled comparative evaluations of compressed, cryogenic, and liquid organic hydrogen carrier (LOHC) pathways, highlighting how catalyst operation and unit process efficiency influence overall performance. The results demonstrate that no single material or transport mode is universally optimal; instead, heterogeneous solutions tuned to specific operational contexts deliver better performance. The project delivers a new capability for cross-scale material co-design, advancing hydrogen infrastructure readiness and informing DOE and LLNL missions in climate and energy resilience.

organic↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗