Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold Climate Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving solar panel durability through novel panel designs and advanced manufacturing equipment

Work in the project was spread across 4 main themes:1) Improved Understanding of Why Cracks Form and Cause Degradation in Solar Cells: We developed a finite element model which correlated well with experimental determined deflection vs load profiles and which predicted stress profiles vs load level and temperature. These profiles helped to guide brace designs and showed the high stress levels seen in the silicon near the interconnect wire locations as the temperature is cooled below -30C, likely forming "invisible" microcracks. Experiments showed how for polymer backsheet modules, a brief exposure to such low temperatures made modules extremely sensitive to propagation of these microcracks at relatively low load levels, and how thicker and softer encapsulant helped to reduce this crack sensitivity. We showed for some modules that most cracks that are seen under loading had their origin at short, hard to see, V-cracks from soldering damage, and how the shunting from cells with high densities of cracks reduces energy delivery more than Pmax. 2) Improved Durability Testing Methods With Respect to Cracked Cells: We lobbied the PV community throughout the project that IEC 61215 was insufficient to probe the sensitivity of module Pmax degradation due to cracks in that in did not have a test leg that included a crack creation step (static loading) followed by a crack opening step (cyclic loading and/or thermal cycling). We published extensively on how pre- existing cracks opened up with cyclic loading. The new IEC TS 63209-1 ED1 test sequence now include our recommendations, and this should lead to improved module designs and reduced risk for investors. We also published recommendations for a new "Cold Climate Test" sequence to probe the sensitivity of modules to degradation from short microcracks formed when modules see temperatures below -30C followed by front side loading. We participated in several USTAG meetings related to cracked cells, EL testing, and mechanical load testing and provided input to the group to improve new standards under consideration. We also showed how the act of performing an EL test can affect the test results due to heating from the injected current. 3) New Module Designs and Related Manufacturing Methods & Equipment: We demonstrated reduced crack sensitivity on encapsulated cell coupons the benefits of building protective compressive stress into the cells by laminating them in a bent state and then allowing the coupon to flatten out after lamination. Our attempts to scale this to the module level with a more manufacturable sequence did not demonstrate the same positive effects, but we hope that others will follow up with other variations on this bent lamination or bent cooling concept to make more durable modules. 4) New Module Mounting Designs: We explored a range of bracing concepts which pressed on the backsheet to slightly bow the glass outward and place cells in a state of protective compressive stress and to reduce the deflection under front side loads. These successfully reduced cell cracking and crack opening, but high static loads permanently deformed cost-effective braces, after which they provided little benefit. We settled on an elegant & effective solution – the RailPad, where lightweight bracing elements are placed between the mounting rail(s) and the backsheet, and the existing strength of the rails is used to prevent module deflection under load. New construction and retrofit designs were made, and test sites were implemented in FL and MA. We applied for RailPad patent protection.

14 SOLAR ENERGY↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

This research involved construction of a conditioned test hut in a cold climate (Climate Zone 5A) with multiple side-by-side instrumented roof rafter bays. This work examined seven experimental unvented roofs and one code-compliant control hybrid ccSPF-cellulose roof over three winters and following summers. Examined variables included insulation material (fiberglass and cellulose), the presence or absence of a ridge diffusion vent (vapor-open material at the roof ridge to promote drying), the effect of various interior vapor control membranes (fixed and variable permeance), the effect of interior relative humidity, and the effect of interstitial airflow (from the interior into the cavity). This experiment was run over three winters, changing variables of interior conditions, roof configurations/materials, and the addition of intentional air leakage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Launch Alaska Transportation and Energy Accelerator (LATEA)

The Launch Alaska Transportation and Energy Accelerator (LATEA), funded through the U.S. Department of Energy Office of Technology Commercialization’s Energy Program for Innovation Clusters (EPIC),advanced deployment of innovative and efficient transportation and energy technology in Alaska from October 2021 through June 2025. The project was designed to leverage Launch Alaska’s accelerator model to identify, recruit, and support transportation technology companies with novel solutions to market needs while building the stakeholder networks, demonstration opportunities, and institutional capacity necessary to accelerate commercialization in one of the most challenging operating environments in the United States.

08 HYDROGEN↗

Evolution of CO2 and H2O on Mars: A cold Early History?

The martian climate has long been thought to have evolved substantially through history from a warm and wet period to the current cold and dry conditions on the martian surface. This view has been challenged based primarily on evidence that the early Sun had a substantially reduced luminosity and that a greenhouse atmosphere would be difficult to sustain on Mars for long periods of time. In addition, the evidence for a warm, wet period of martian history is far from conclusive with many of the salient features capable of being explained by an early cold climate. An important test of the warm, wet early Mars hypothesis is the abundance of carbonates in the crust [1]. Recent high precision isotopic measurements of the martian atmosphere and discoveries of carbonates on the martian surface provide new constraints on the evolution of the martian atmosphere. This work seeks to apply these constraints to test the feasibility of the cold early scenario

Niles, P. B.↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Cold Climate Heat Pump Technology Challenge (Rheem) (CRADA NFE-22-09374 Final Report)

The purpose of this CRADA was to test a nominal 3-ton capacity heat pump system supplied by Rheem Manufacturing to determine if it met the laboratory test requirements of the United States Department of Energy Cold Climate Heat Pump (CCHP) Technology Challenge (hereafter noted as “the Challenge”). Results of the laboratory testing completed at ORNL demonstrated that the system met all requirements of the Challenge. Rheem Manufacturing has successfully completed this aspect of the Challenge. This CRADA report will briefly describe the CCHP Challenge, the test plan created to measure the success of heat pump systems provided by CCHP Challenge participants, and the results of laboratory testing of the Rheem heat pump system.

42 ENGINEERING↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NREL’s Collaboration with Alaska’s Cold Climate Housing Research Center Builds Mission Impact in Extreme Climates

A new collaboration between NREL and CCHRC represents the combination of NREL’s wealth of knowledge and experience in the building technology space with decades of experience researching building technologies in extreme climates by CCHRC. The collaboration generates potential for creative, new ideas, creates opportunities for researchers on both ends, and rapidly expands NREL’s mission impact on a global scale by granting it access to Arctic climates, test facilities at CCHRC, and new insight into the local landscape and native challenges.

Alaska↗

NREL’s Collaboration with Alaska’s Cold Climate Housing Research Center Builds Mission Impact in Extreme Climates

A new collaboration between NREL and CCHRC represents the combination of NREL’s wealth of knowledge and experience in the building technology space with decades of experience researching building technologies in extreme climates by CCHRC. The collaboration generates potential for creative, new ideas, creates opportunities for researchers on both ends, and rapidly expands NREL’s mission impact on a global scale by granting it access to Arctic climates, test facilities at CCHRC, and new insight into the local landscape and native challenges.

Alaska↗

Assessing the National Off-Cycle Benefits of 2-Layer HVAC Technology Using Dynamometer Testing and a National Simulation Framework

Some CO2-reducing technologies have real-world benefits not captured by regulatory testing methods. This paper documents a two-layer heating, ventilation, and air-conditioning (HVAC) system that facilitates faster engine warmup through strategic increased air recirculation. The performance of this technology was assessed on a 2020 Hyundai Sonata. Empirical performance of the technology was obtained through dynamometer tests at Argonne National Laboratory. Performance of the vehicle across multiple cycles and cell ambient temperatures with the two-layer technology active and inactive indicated fuel consumption reduction in nearly all cases. A thermally sensitive powertrain model, the National Renewable Energy Laboratory's FASTSim Hot, was calibrated and validated against vehicle testing data. The developed model included the engine, cabin, and HVAC system controls. Validation of component thermal models and engine efficiency ensured accurate thermal dynamics, fuel consumption, and two-layer benefit. The real-world benefit of the two-layer technology was calculated by simulating the validated powertrain model across a representative test matrix comparing performance with and without the two-layer system. Simulation across the test matrix revealed a real-world representative benefit of 0.0835%. Analysis of test matrix results at the regional level revealed the most benefit in cold climates and rural regions. Mean results across cycle length sensitivity simulations revealed a larger real-world benefit of 0.0872%. These benefit values can be considered a more accurate assessment of real-world technology performance. Future work is planned to explore the requisite number of drive cycles to ensure the full technology benefit is captured.

2-layer↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗