Search NASA⌕ Search

SEARCH · Search NASA

Results for “Common bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz↗

Networked Microgrids for Self-healing Power Systems

This paper proposes a transformative architecture for the normal operation and self-healing of networked microgrids (MGs). MGs can support and interchange electricity with each other in the proposed infrastructure. The networked MGs are connected by a physical common bus and a designed two-layer cyber communication network. The lower layer is within each MG where the energy management system (EMS) schedules the MG operation; the upper layer links a number of EMSs for global optimization and communication. In the normal operation mode, the objective is to schedule dispatchable distributed generators (DGs), energy storage systems (ESs) and controllable loads to minimize the operation costs and maximize the supply adequacy of each MG. When a generation deficiency or fault happens in a MG, the model switches to the self-healing mode and the local generation capacities of other MGs can be used to support the on-emergency portion of the system. A consensus algorithm is used to distribute portions of the desired power support to each individual MG in a decentralized way. The allocated portion corresponds to each MG’s local power exchange target which is used by its EMS to perform the optimal schedule. The resultant aggregated power output of networked MGs will be used to provide the requested power support. Test cases demonstrate the effectiveness of the proposed methodology.

Consensus Algorithm↗

Data distribution service-based interoperability framework for smart grid testbed infrastructure

This study presents the design and implementation of a communication and control infrastructure for smart grid operation. The proposed infrastructure enhances the reliability of the measurements and control network. The advantages of utilizing the data-centric over message-centric communication approach are discussed in the context of smart grid applications. The data distribution service (DDS) is used to implement a data-centric common data bus for the smart grid. This common data bus improves the communication reliability, enabling distributed control and smart load management. These enhancements are achieved by avoiding a single point of failure while enabling peer-to-peer communication and an automatic discovery feature for dynamic participating nodes. The infrastructure and ideas presented in this paper were implemented and tested on the smart grid testbed. A toolbox and application programing interface for the testbed infrastructure are developed in order to facilitate interoperability and remote access to the testbed. This interface allows control, monitoring, and performing of experiments remotely. Furthermore, it could be used to integrate multidisciplinary testbeds to study complex cyber-physical systems (CPS).

97 MATHEMATICS AND COMPUTING↗

Fuel cells, batteries and super-capacitors stand-alone power systems management using optimal/flatness based-control

In this work, an optimal control (under constraints) based on the Pontryagin’s maximum principle is used to optimally manage energy flows in a basic PEM (Proton Exchange Membrane) fuel cells system associated to lithium-ion batteries and supercapacitors through a common DC bus having a voltage to stabilize using the differential flatness approach. The adaptation of voltage levels between different sources and load is ensured by use of three DC-DC converters, one boost connected to the PEM fuel cells, while the two others are buck/boost and connected to the lithiumion batteries and supercapacitors. The aim of this paper is to develop an energy management strategy that is able to satisfy the following objectives: Impose the power requested by a habitat (representing the load) according to a proposed daily consumption profile, Keep fuel cells working at optimal power delivery conditions, Maintain constant voltage across the common DC bus, Stabilize the batteries voltage and stored quantity of charge at desired values given by the optimal control. Results obtained under MATLAB/Simulink environment prove that the cited objectives are satisfied, validating then, effectiveness and complementarity between the optimal and flatness concepts proposed for energy management. Note that this study is currently in experimentally validation within MSE Laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SiC MOSFET Based Modular Universal Power Electronics Regulator

A modular and scalable SiC MOSFET based universal power electronics regulator (UPER) allows coordinated integration of energy resources and loads, elimination of extra power conversion stages, and allowance of more sources or loads added with a simple plug and play feature. A comprehensive investigation has been conducted in term of the typical distributed generations and loads employed in buildings, in order to outline a detailed specification for UPER. Thus, a common DC bus voltage of 500 V and power rating of 3 kW are dedicatedly selected. The UPER hardware design and implementation are completely illustrated, including the static and dynamic characterization of the employed SiC MOSFET. The dedicated universal power cell and Plug-and-Play gate driver performs reliable continuous operation even exposed to an extreme fast switching speed (> 100 V/ns). The continuous operation of buck mode verified the UPER hardware development at 50 kHz with an overall efficiency of 98.19%. A new voltage polarity reversal phenomenon was also discovered in the verification of the isolated DAB stage with planar transformers.

Zheng, Sheng↗

PowerConverterDynamics.jl

SAND2026-22944O PowerConverterDynamics.jl is a Julia software package for differentiable DC power-conversion dynamics. It models a variable DC source, power converter, common DC bus, and battery module with current, voltage, loss, and state-of-charge dynamics. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Silicon photonic chip for 16-channel wavelength division (de-)multiplexing in the O-band

We experimentally demonstrate a silicon photonic chip-scale 16-channel wavelength division multiplexer (WDM) operating in the O-band. The silicon photonic chip consists of a common-input bus waveguide integrated with a sequence of 16 spectral add-drop filters implemented by 4-port contra-directional Bragg couplers and resonant cladding modulated perturbations. The combination of these features reduces the spectral bandwidth of the filters and improves the crosstalk. An apodization of the cladding modulated perturbations between the bus and the add/drop waveguides is used to optimize the strength of the coupling coefficient in the propagation direction to reduce the intra-channel crosstalk on adjacent channels. The fabricated chip was validated experimentally with a measured intra-channel crosstalk of ∼−18.9 dB for a channel spacing of 2.6 nm. The multiplexer/demultiplexer chip was also experimentally tested with a 10 Gbps data waveform. The resulting eye-pattern indicates that this approach is suitable for datacenter WDM-based interconnects in the O-band with large aggregate bandwidths.

Davis, Jordan A. (ORCID:0000000343483295)↗

Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants

A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

14 SOLAR ENERGY↗

Distributed Energy Resources Customer Adoption Model - Graphical User Interface, Version 2.1.8

The DER-CAM Graphical User Interface has been redesigned to consist of a dynamic tree structure on the left side of the application window to allow users to quickly navigate between different data categories and views. Views can either be tables with model parameters and input data, the optimization results, or a graphical interface to draw circuit topology and visualize investment results. The model parameters and input data consist of tables where values are assigned to specific keys. The aggregation of all model parameters and input data amounts to the data required to build a DER-CAM model, and is passed to the GAMS solver when users initiate the DER-CAM optimization process. Passing data to the GAMS solver relies on the use of a Java server that handles DER-CAM requests, queuing, and results delivery. This component of the DER-CAM GUI can be deployed either locally or remotely, and constitutes an intermediate step between the user data input and manipulation, and the execution of a DER-CAM optimization in the GAMS engine. The results view shows the results of the DER-CAM optimization and distinguishes between a single and a multi-objective process. The single optimization runs the DER-CAM optimization once and presents the results as a combination of summary charts and hourly dispatch profiles. The multi-objective optimization process consists of a sequence of runs initiated by the GUI, including: 1) CO2 minimization, 2) cost minimization, 3) a user defined number of points in-between objectives 1) and 2). The multi-objective results view includes both access to the detailed results of each point generated by the process as well as the generation of a Pareto Frontier graph to illustrate the trade-off between objectives. DER-CAM GUI 2.1.8 also introduces the ability to graphically generate circuit topologies, enabling support to DER-CAM 5.0.0. This feature consists of: 1) The drawing area, where users can manually create nodes and define their properties (e.g. point of common coupling, slack bus, load) and connect them through edges representing either power lines, transformers, or heat pipes, all with user defined characteristics (e.g., length, ampacity, inductance, or heat loss); 2) The tables, which display the user-defined topology in the final numerical form that will be passed to the DER-CAM optimization. Finally, the DER-CAM GUI is also deployed with a database schema that allows users to provide different energy load profiles, solar irradiance profiles, and tariff data, that can be stored locally and later used in any DER-CAM model. However, no real data will be delivered with this version.

Ewald, Friedrich↗

A Sparse Tableau Formulation for Node-Breaker Representations in Security-Constrained Optimal Power Flow

Realistic representations of contingencies in AC optimal power flow (ACOPF) often challenge traditional bus-branch network models. Derived from nodal analysis, such approaches represent network constraints in terms of the familiar bus admittance matrix, Ybus. A fixed Ybus is unable to represent common circuit breaker actions such as bus splitting. Work-arounds for Ybus-based analysis typically rely on topology processing, switching between different Ybus matrices depending on breaker settings. In this paper, we propose a very general node-breaker approach, employing multi-port element models and using a sparse tableau formulation (STF) for network constraints. Instead of treating breaker action as altering network topology, and hence changing the structure of Kirchhoff’s voltage law (KVL) and Kirchhoff’s current law (KCL) equations, this approach represents a breaker’s position as impacting only constraints associated with a single component, thereby maintaining fixed structure in the KVL and KCL constraints. While larger numbers of variables are required, STF proves sparser than Ybus formulations. Numerical case studies herein demonstrate that STF provides computational efficiency comparable to a Ybus-based ACOPF at the scale of several hundred buses, and lower computational cost in an example of over one thousand buses.

Park, Byungkwon (ORCID:000000033189816X)↗

Financial Analysis of Battery Electric Transit Buses

A baseline bus fleet and battery electric bus investment scenario was developed based on the average or common parameters of existing battery electric bus (BEB) fleets. A discounted cashflow analysis was done that found the baseline fleet to have a net present value of $785,000 and simple payback of 3.3 years. The 33 main parameters were then swung ±50% to determine their relative influence on NPV and were ranked accordingly. Then parameter volatility was estimated by dividing the range of observed values by the baseline value. The parameters that are most influential and volatile were highlighted as the ones fleet managers should focus on when determining if BEBs are a good investment option for them. These top parameters are 1) BEB purchase price, 2) purchase price of foregone diesel bus, 3) grant amount, 4) maintenance costs of foregone diesel bus, 5) annual vehicle miles traveled.

25 ENERGY STORAGE↗

Autonomic Intelligent Cyber Sensor to Support Industrial Control Network Awareness

The proliferation of digital devices in a networked industrial ecosystem, along with an exponential growth in complexity and scope, has resulted in elevated security concerns and management complexity issues. This paper describes a novel architecture utilizing concepts of Autonomic computing and a SOAP based IF-MAP external communication layer to create a network security sensor. This approach simplifies integration of legacy software and supports a secure, scalable, self-managed framework. The contribution of this paper is two-fold: 1) A flexible two level communication layer based on Autonomic computing and Service Oriented Architecture is detailed and 2) Three complementary modules that dynamically reconfigure in response to a changing environment are presented. One module utilizes clustering and fuzzy logic to monitor traffic for abnormal behavior. Another module passively monitors network traffic and deploys deceptive virtual network hosts. These components of the sensor system were implemented in C++ and PERL and utilize a common internal D-Bus communication mechanism. A proof of concept prototype was deployed on a mixed-use test network showing the possible real world applicability. In testing, 45 of the 46 network attached devices were recognized and 10 of the 12 emulated devices were created with specific Operating System and port configurations. Additionally the anomaly detection algorithm achieved a 99.9% recognition rate. All output from the modules were correctly distributed using the common communication structure.

97 MATHEMATICS AND COMPUTING↗

Distributed Load Shedding Application Architecture and Bi-Level Predictive Estimator Algorithm

Increasing penetrations of distributed renewables are decreasing the effectiveness of traditional decentralized under-frequency load shedding (UFLS) schemes. As more distribution circuits begin to back-feed the transmission system, operation of traditional UFLS may exacerbate frequency instability. This paper presents the conceptual framework for a data-rich environment to coordinate UFLS across multiple distribution providers based on the laminar coordination framework in order to ensure optimal adaptive setting of UFLS relays. Communication and control are enabled through a distributed implementation of the IEC 61968-1 Common Information Model message bus structure. In addition to the proposed architecture, a novel adaptive UFLS scheme informed by a bi-level state estimator to create optimal relay setpoints is introduced. Initial simulation results are presented for the IEEE 14-bus test system on scenarios leading to mis-operation of traditional UFLS.

Anderson, Alexander A.↗

OLED panel with fuses

Embodiments may provide a first device that may comprise a substrate, a plurality of conductive bus lines disposed over the substrate, and a plurality of OLED circuit elements disposed on the substrate, where each of the OLED circuit elements comprises one and only one pixel electrically connected in series with a fuse. Each pixel may further comprise a first electrode, a second electrode, and an organic electroluminescent (EL) material disposed between the first and the second electrodes. The fuse of each of the plurality of OLED circuit elements may electrically connect each of the OLED circuit elements to at least one of the plurality of bus lines. Each of the plurality of bus lines may be electrically connected to a plurality of OLED circuit elements that are commonly addressable and at least two of the bus lines may be separately addressable.

42 ENGINEERING↗

Nested Microgrids for Increased Grid Resiliency

The article presents a control and communication architecture for interconnecting multiple microgrids by leveraging IEC 61850 data models with distributed energy resources (DER) extensions, IEC Common Information Model (CIM) and Open Field Message Bus (OpenFMB) frameworks. An example use case for planned islanding in the nested microgrid scenario is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Approach to Linear Accelerator Superconducting Magnet System

Superconducting Linear Accelerators include a superconducting magnet system for particle beam transportation that provides the beam focusing and steering. This system consists of a large number of quadrupole magnets and dipole correctors mounted inside or between cryomodules with SCRF cavities. Each magnet has current leads and powered from its own power supply. The paper proposes a novel approach to magnet powering based on using superconducting persistent current switches. A group of magnets is powered from the same power supply through the common, for the group of cryomodules, electrical bus and pair of current leads. Superconducting switches direct the current to the chosen magnet and close the circuit providing the magnet operation in a persistent current mode. Two persistent current switches were fabricated and tested. In the paper also presented the results of magnetic field simulations, decay time constants analysis, and a way of improving quadrupole magnetic center stability. Such approach substantially reduces the magnet system cost and increases the reliability.

43 PARTICLE ACCELERATORS↗

Wide area fault detection method using PMU data

The embodiments herein are directed to monitoring in real time, power system data so as to provide insights into global operation of a power grid. Such a scheme disclosed herein utilizes rules, which are created by analyzing PMU measurement data, in order to detect the fault location (bus and line) and fault type. Three common types of faults in a power grid, single-line-to-ground (SLG), line-to-line (LL), and three phase faults, can be detected using the methods herein.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗