Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compact Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Strategy Guideline: Compact Air Distribution Systems

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft 2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Compact Air Distribution Systems

This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airborne lidar mapping of vertical ozone distributions in support of the 1990 Clean Air Act Amendments

The 1990 Clean Air Act Amendments mandated attainment of the ozone standard established by the U.S. Environmental Protection Agency. Improved photochemical models validated by experimental data are needed to develop strategies for reducing near surface ozone concentrations downwind of urban and industrial centers. For more than 10 years, lidar has been used on large aircraft to provide unique information on ozone distributions in the atmosphere. However, compact airborne lidar systems are needed for operation on small aircraft of the type typically used on regional air quality investigations to collect data with which to develop and validate air quality models. Data presented in this paper will consist of a comparison between airborne differential absorption lidar (DIAL) and airborne in-situ ozone measurements. Also discussed are future plans to improve the airborne ultraviolet-DIAL for ozone and other gas observations and addition of a Fourier Transform Infrared (FTIR) emission spectrometer to investigate the effects of other gas species on vertical ozone distribution.

Uthe, Edward E.↗

Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

air distribution↗

Building America Case Study: Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis of a Modular Small-Diamter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis of a Modular Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Photocatalytic Air Processor for Dramatic Reduction of Life Support Mass and Complexity

To dramatically reduce the cost and risk of CO2 management systems in future extended missions, we have conducted preliminary studies on the materials and device development for advanced "artificial photosynthesis" reaction systems termed the High Tortuosity PhotoElectroChemical (HTPEC) system. Our Phase I studies have demonstrated that HTPEC operates in much the same way a tree would function, namely directly contacting the cabin air with a photocatalyst in the presence of light and water (as humidity) to immediately conduct the process of CO2 reduction to O2 and useful, "tunable" carbon products. This eliminates many of the inefficiencies associated with current ISS CO2 management systems. We have laid the solid foundation for Phase II work to employ novel and efficient reactor geometries, lighting approaches, 3D manufacturing methods and in-house grown novel catalytic materials.The primary objective of the proposed work is to demonstrate the scientific and engineering foundation for light-activated, compact devices capable of converting CO2 to O2 and mission-relevant carbon compounds. The proposed HTPEC CO2 management system will demonstrate a novel pathway with high efficiency and reliability in a compact, lightweight reactor architecture. The proposed HTPEC air processing concept can be developed in multiple architectures, such as centralized processing as well as "artificial leaves" distributed throughout the cabin that utilize pre-existing cabin ventilation (wind). Additionally, HTPEC can be deployed with spectrally tunable collection channels for selectable product generation. HTPEC employs light as its only energy source to remove and convert waste CO2 using a non-toxic composite catalyst.We have demonstrated in the Phase I studies the production, tunability and robustness of the novel composite catalysts following the preliminary work in the Chen laboratory. Additionally, we have designed, fabricated and tested all components of HTPEC device with active materials, including flow modeling to optimize flow mixing and pressure drop as well as the production of ethylene and other larger hydrocarbons. To best determine how this technology could be implemented, we also performed system integration optimization and trade studies. This includes parameters such as mass, volume, power in relation to selected mission configurations, CO2 delivery methods and light source/delivery approaches.

Artificial Photosynthesis↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, Californi

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes' Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system's plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

HVAC↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low-grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling-up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compact, Inexpensive Micro-Reformer for Distributed GTL Systems (Final Scientific/Technical Report)

This award allowed MIT Plasma Science and Fusion Center, in collaboration with the Departments of Chemical and Mechanical Engineering, to demonstrate the feasibility of using an engine as the reformer for a gas-to-liquids plants. Engine reformation in cylinder has been used in the past for limited production of hydrogen rich gas. However, the performance was limited, and for syngas generation as part of a chemical plant, the output was inadequate. The focus of the ARPA-E seed project was to demonstrate, in oxygen or in air, the production of hydrogen rich gas with good conversion and selectivity. The goal was equivalence ratios ~ 3 in oxygen, or highly enriched air. The accomplishment performance was equivalence ratios ~ 2 with air.

03 NATURAL GAS↗

Electrical Capacitance Volume Tomography for the Packed Bed Reactor ISS Flight Experiment

Fixed packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a highly desirable unit operation for long duration life support systems in space. NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. To validate these models, the instantaneous distribution of the gas and liquid phases must be measured.Electrical Capacitance Volume Tomography (ECVT) is a non-invasive imaging technology recently developed for multi-phase flow applications. It is based on distributing flexible capacitance plates on the peripheral of a flow column and collecting real-time measurements of inter-electrode capacitances. Capacitance measurements here are directly related to dielectric constant distribution, a physical property that is also related to material distribution in the imaging domain. Reconstruction algorithms are employed to map volume images of dielectric distribution in the imaging domain, which is in turn related to phase distribution. ECVT is suitable for imaging interacting materials of different dielectric constants, typical in multi-phase flow systems. ECVT is being used extensively for measuring flow variables in various gas-liquid and gas-solid flow systems. Recent application of ECVT include flows in risers and exit regions of circulating fluidized beds, gas-liquid and gas-solid bubble columns, trickle beds, and slurry bubble columns. ECVT is also used to validate flow models and CFD simulations. The technology is uniquely qualified for imaging phase concentrations in packed bed reactors for the ISS flight experiments as it exhibits favorable features of compact size, low profile sensors, high imaging speed, and flexibility to fit around columns of various shapes and sizes. ECVT is also safer than other commonly used imaging modalities as it operates in the range of low frequencies (1 MHz) and does not radiate radioactive energy. In this effort, ECVT is being used to image flow parameters in a packed bed reactor for an ISS flight experiment.

Tomography↗

The Effect of the Degree of Premixedness on Self-Excited Combustion Instability

The use of lean, premixed fuel and air mixtures is a common strategy to reduce NO x emissions in gas turbine combustors. However, this strategy causes an increased susceptibility to self-excited instability, which manifests as fluctuations in heat release rate, flow velocity, and combustor acoustics that oscillate in-phase in a feedback loop. Here, this study considers the effect of the level of premixedness on the self-excited instability in a single-nozzle combustor. In this system, the fuel can be injected inside the nozzle to create a partially-premixed mixture or far upstream to create a fully-premixed mixture, varying the level of premixedness of the fuel and air entering the combustor. When global equivalence ratio is held constant, the cases with higher levels of premixing have higher instability amplitudes. High-speed CH* chemiluminescence imaging shows that the flame for these cases is more compact and the distribution of the heat release rate oscillations is more concentrated near the corner of the combustor in the outer recirculation zones. Rayleigh index images, which are a metric for the relative phase of pressure and heat release rate oscillations, suggest that vortex rollup in the corner region is primarily responsible for determining instability characteristics when premixedness is varied. This finding is further supported through analysis of local flame edge dynamics.

42 ENGINEERING↗