Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compact Electrode Configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Scaling-up up-flow microbial electrolysis cells with a compact electrode configuration for continuous hydrogen production

Maintaining high current densities is a key challenge in scaling-up microbial electrolysis cell (MEC) reactors. In this study, a novel 10 L MEC reactor with a total electrode surface area > 1 m 2 was designed and evaluated to maximize the current density and H 2 recovery. Performances of the reactor suggest that the longitudinal structure with parallel vertical orientation of the electrodes encouraged high fluid mixing and the sheet metal electrode frames provided distributed electrical connection. Results also demonstrated that the electrode pairs located next to reactor walls decreased current density, as did separating the electrodes with separators. High volumetric H 2 production rate of 5.9 L/L/d was achieved at a volumetric current density of 970 A/m 3 (34 A/m 2 ). Furthermore, the observed current densities of the large reactor were accurately predicted based on the internal resistance analysis of small scale MECs (0.15 L), demonstrating the scalability of the single chamber MEC design.

08 HYDROGEN↗

Scalable membrane-less microbial electrolysis cell with multiple compact electrode assemblies for high performance hydrogen production

Bioelectrochemical hydrogen production via microbial electrolysis cells (MECs) is a promising method for sustainable energy production and decarbonization of energy systems. However, the application of MECs is limited by the electrochemical performance, scalability, and the cost associated with expensive materials. Here, in this study, a scalable MEC (500 mL) with novel compact electrode assemblies and high electrode surface area to volume ratio (160 m 2 /m 3 ) was designed and constructed. The use of membranes, precious metal catalyst, and current collectors with high costs was avoided. A high current density at the steady state of 49.5 ± 5.3 A/m 2 was achieved using acetate as the substrate with phosphate buffer under the applied voltage of 1.01 V. The corresponding volumetric current density was 3948 ± 422 A/m 3 . The compact electrode assembly design limited methane production rate to 3.9 ± 0.2 L/L/D, while achieving a hydrogen production rate of 33.7 ± 1.7 L/L/D. With the suppression of microbial hydrogen consumption, the hydrogen production rate was 39.8 ± 1.9 L/L/D, higher by almost one order of magnitude than those of MECs with scaling up attempts. The compact electrode configuration reduced internal resistance to 88.5 ± 4.4 Ω cm 2 . The energy efficiency based on input electricity was 146 ± 7 % to 189 ± 9 % within the applied voltage range of 0.71 to 1.05 V. The results in this study demonstrated successful scaling up of high performance small MECs and offered a new possible approach of scaling up MECs by stacking high-performance subunits, with no trade-offs on electrochemical performance.

08 HYDROGEN↗

Multielectrode electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

A multielectrode-based electrochemical cell allows the structural characterization of an amorphous thin-film water oxidation catalyst under various electrochemical potentials using high-energy X-ray scattering and atomic pair distribution function (PDF) techniques. A multielectrode with five electrodes provides a sufficiently low background signal to enable high-energy X-ray scattering (HEXS) measurements and amplifies the extremely low HEXS signals from samples for high-resolution PDF analysis of in situ data from thin-film catalysts. Glassy carbon (GC) creates a relatively low intensity HEXS pattern and is used as a working electrode. Instead of a three-dimensional (3D) porous electrode architecture, the flat geometry of the electrode enables various deposition techniques to be used for the preparation of a highly conductive metal oxide layer. PDF analysis demonstrates high spatial resolution for a 230 nm thick amorphous iridium oxide film deposited on two roughened 60 µm thick GC electrodes. The PDF analysis resolves the domain size and distinguishes changes in fine structure which are directly correlated with the structure and function of the catalysts. In conclusion, the results bring the opportunity to analyze the structure of nanometre-scale amorphous thin-film catalysts in an electrolyte-compatible and compact 3D-printed electrochemical cell in a three-electrode configuration.

36 MATERIALS SCIENCE↗

Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers

Distribution of relaxation time (DRT) is used to interpret electrochemical impedance spectroscopy (EIS) for proton exchange membrane (PEM) water electrolyzers, with an attempt to separate overlapped relaxation processes in Nyquist plots. By varying operating conditions and catalyst loadings, four main relaxation peaks arising from EIS can be identified and successfully separated from low to high frequencies as (P1) mass transport, (P2) oxygen evolution reaction kinetics, (P3) reaction kinetics (with faster time constant than P2), and (P4) ionic transport. Here, the shape, height, and frequency of the DRT peaks change with different membrane electrode assembly (MEA) configurations. Electron microscopy reveals distinct features from the cross-sectioned MEAs which verify critical DRT results in that increasing the iridium (Ir)-anode loading from 0.2 mgIr/cm 2 to 1.5 mgIr/cm 2 reduces kinetic losses due to higher site-access; a thick and compacted anode, however, also triggers higher ohmic resistances from membrane/catalyst layer hydration and increases transport losses due to longer ionomer pathways. DRT provides higher resolution to EIS for deconvoluting processes with different relaxation times and the quantification of DRT peaks improves the accounting of total losses from each process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of transient CHI startup using a floating biased electrode configuration

Abstract Results from the successful solenoid-free plasma startup using the method of transient coaxial helicity injection (transient CHI) in the QUEST spherical tokamak (ST) are reported. Unlike previous applications of CHI on HIT-II and on NSTX which required two toroidal insulating breaks to the vacuum vessel, QUEST uses a first of its kind, floating single biased electrode configuration, which does not use such a vacuum break. Instead, the CHI electrode is simply insulated from the outer lower divertor plate support structure. This configuration is much more suitable for implementation in a fusion reactor than the previous configurations. Transient CHI generated toroidal currents of 135 kA were obtained. The toroidal current during the formation of a closed flux configuration was over 50 kA. These results bode well for the application of transient CHI in a new generation of compact high-field STs and tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced plasma performance in C-2W advanced beam-driven field-reversed configuration experiments

TAE Technologies’ fifth-generation fusion device, C-2W (also called ‘Norman’), is the world’s largest compact-toroid device and has made significant progress in field-reversed configuration (FRC) plasma performance. C-2W produces record breaking, macroscopically stable, high-temperature advanced beam-driven FRC plasmas, dominated by injected fast particles and sustained in steady state, which is primarily limited by neutral-beam (NB) pulse duration. The NB power supply system has recently been upgraded to extend the pulse length from 30 ms to 40 ms, which allows for a longer plasma lifetime and thus better characterization and further enhancement of FRC performance. An active plasma control system is routinely used in C-2W to produce consistent FRC performance as well as for reliable machine operations using magnet coils, edge-biasing electrodes, gas injection and tunable-energy NBs. Google’s machine learning framework for experimental optimization has also been routinely used to enhance plasma performance. D

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental demonstration of transient CHI start-up using a floating biased electrode configuration

Transient coaxial helicity injection (CHI) current start-up in a spherical tokamak (ST) has been demonstrated for the first time using a reactor-relevant floating single biased (FSB) electrode configuration on QUEST. Unlike previous applications of CHI on HIT-II and on NSTX in which the entire ST vessel was split in two using two toroidal ceramic rings as vacuum breaks, in the FSB electrode configuration on QUEST, only the lower outer divertor plate is electrically insulated from the rest of the vessel. This is the CHI injector region. A CHI discharge is generated by driving current, using an external power supply, along magnetic field lines that connect the inner and outer divertor plates in the CHI injector region. The CHI plasma evolution and closed flux formation on QUEST are very similar to those on NSTX and have generated toroidal currents of 150 kA with 100 kA of current flowing on closed flux surfaces. An alternate, force-free model approach has been used to derive the CHI scaling relations. The resulting CHI scaling relations from the model are consistent with the conventional CHI scaling relations, which state that the CHI generated toroidal current is proportional to the CHI injector flux and the CHI injector current is inversely proportional to the toroidal field. These results from QUEST bode well for the application of CHI in a new generation of compact high field STs and low aspect ratio tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes

Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .

42 ENGINEERING↗