Search NASA⌕ Search

SEARCH · Search NASA

Results for “Complete Bouger anomaly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Utah FORGE: Milford Gravity Data Shapefile

This is a zipped GIS compatible shapefile of gravity data points used in the Milford, Utah FORGE project as of March 21st, 2016. The shapefile is native to ArcGIS, but can be used with many GIS software packages. Additionally, there is a .dbf (dBase) file that contains the dataset which can be read with Microsoft Excel. The Data was downloaded from the PACES (Pan American Center for Earth and Environmental Studies) hosted by University of Texas El Paso. A readme file is included in the archive with abbreviation explanations and units.

15 GEOTHERMAL ENERGY↗

Maui Gravity and Soil Gas Surveys

Contains a ground-based gravity survey of South Maui and a series of soil CO2 flux and temperature surveys encompassing Maui and the Big Island. The gravity survey was collected from approximately 284 km2 and consisted of 400 gravity stations with 400 m spacing. Locations were derived with full DGPS. Station and line location, Complete Bouger Anomaly, first vertical derivative and horizontal gradient maps were calculated and produced. The soil CO2 flux and temperature surveys were conducted on the islands of Hawaii and Maui in April and July 2010. Average soil temperatures were measured over 10 cm depth using a hand-held thermocouple. Soil CO2 fluxes were measured using a portable accumulation chamber instrument.

15 GEOTHERMAL ENERGY↗

Gravity Survey of the Carson Sink - Data and Maps

A detailed gravity survey was carried out for the entire Carson Sink in western Nevada (Figure 1) through a subcontract to Zonge Engineering, Inc. The Carson Sink is a large composite basin containing three known, blind high-temperature geothermal systems (Fallon Airbase, Stillwater, and Soda Lake). This area was chosen for a detailed gravity survey in order to characterize the gravity signature of the known geothermal systems and to identify other potential blind systems based on the structural setting indicated by the gravity data. Data were acquired at approximately 400, 800, and 1600 meter intervals for a total of 1,243 stations. The project location and station location points are presented in Figure 14. The station distribution for this survey was designed to complete regional gravity coverage in the Carson Sink area without duplication of available public and private gravity coverage. Gravity data were acquired using a Scintrex CG-5 gravimeter and a LaCoste and Romberg (L&R) Model-G gravimeter. The CG-5 gravity meter has a reading resolution of 0.001 milligals and a typical repeatability of less than 0.005 milligals. The L&R gravity meter has a reading resolution of 0.01 milligals and a typical repeatability of 0.02 milligals. The basic processing of gravimeter readings to calculate through to the Complete Bouguer Anomaly was made using the Gravity and Terrain Correction software version 7.1 for Oasis Montaj by Geosoft LTD. The gravity survey of the Carson Sink yielded a project location and station location map, a Complete Bouguer Anomaly @ 2.67 gm/cc reduction density, a Gravity Complete Bouguer Anomaly at 2.50 g/cc Contour Map, a Gravity Horizontal Gradient Magnitude Shaded Color Contour Map, a Gravity 1st Vertical Derivative Color Contour Map, and an Interpreted Depth to Mesozoic Basement incorporating drill-hole intercept values. A preliminary interpretation of these results suggests that the Carson Sink is a complex composite basin with several major depocenters. Major depocenters are present in the south-central, east-central, and northeastern parts of the basin. The distribution of gravity anomalies suggests a complex pattern of faulting in the subsurface of the basin, with many fault terminations, step-overs, and accommodation zones. The pattern of faulting implies that other, previously undiscovered blind geothermal systems are likely in the Carson Sink. The gravity survey was completed near the end of this project. Thus, more thorough analysis of the data and potential locations of blind geothermal systems is planned for future work.

15 GEOTHERMAL ENERGY↗

Fallon FORGE: Geophysics and Geochemistry

The data is associated to the Fallon FORGE project and includes mudlogs for all wells used to characterize the subsurface, as wells as gravity, magnetotelluric, earthquake seismicity, and temperature data from the Navy GPO and Ormat. Also included are geologic maps from the USGS and Nevada Bureau of Mines and Geology for the Fallon, NV area.

15 GEOTHERMAL ENERGY↗

Utah FORGE: TEM and Gravity Data

This submission includes a gravity data in text format and as a GIS point shapefile and transient electromagnetic (TEM) raw data. Each text file additionally contains location data (UTM Zone 12, NAD83) and elevation (meters) data for that station. The gravity data shapefile was in part downloaded from PACES, University of Texas at El Paso, http://gis.utep.edu/subpages/GMData.html, and in part collected by the Utah Geological Survey (UGS) as part of the DOE GTO supported Utah FORGE geothermal energy project near Milford, Utah. The PACES data were examined and scrubbed to eliminate any questionable data. A 2.67 g/cm^3 reduction density was used for the Bouguer correction. The attribute table column headers for the gravity data shapefile are explained below. There is also metadata attached to the GIS shapefile. name: the individual gravity station name. HAE: height above ellipsoid [meter] NGVD29: vertical datum for geoid [meter] obs: observed gravity ERRG: gravity measurement error [mGal] IZTC: inner zone terrain correction [mGal] OZTC: outer zone terrain correction [mGal] Gfa: free air gravity gSBGA: Bouguer horizontal slab sCBGA: Complete Bouguer anomaly

15 GEOTHERMAL ENERGY↗

Utah FORGE: 3D Gravity Data

These resources describe the 3D geophysical inversion modeling of gravity data at the FORGE site near Milford, Utah. FORGE is the Frontier Observatory for Research in Geothermal Energy and the site in Utah has been selected by the U.S. Dept. of Energy for a 5-year R&D program to test technologies for the development of Engineered Geothermal Systems (EGS). 3D modelling of gravity data at the FORGE site is to help characterize the subsurface geologic framework. Specifically, modelling of gravity data in 3D, used in conjunction with rock density measurements and other subsurface geologic information can provide an independent test of an existing 3D geologic model (e.g. Witter et al., 2018). Such an exercise can be useful for reducing uncertainty in 3D geologic models (Witter et al, 2019).

15 GEOTHERMAL ENERGY↗